MAURY USCG vessel records
← All vessels

MAPLE GROVE

MAPLE GROVE is a 1954 freight ship. The Coast Guard has recorded 17 inspections since 2016, most recently in September 2024, along with 14 deficiencies and 1 casualty investigation in 2012.

Records from 2012 to 2024. Most recent: inspection, 30 September 2024.

Built
1954
Last inspected
30 September 2024
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 30 September 2024
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDL3831
329093
Flag
UNITED STATES
Maury page id
psix-329093

Documentation record

Registered dimensions (L × B × D)61.1 ft × 20.4 ft × 3.5 ft
Registered tonnagegross 14 / net 10
ITC dimensions (L × B × D)61.1 ft × 20.4 ft × 3.5 ft
ITC tonnageNot recorded
BuilderJ. C. HIGGINS · GALVESTON, TX, UNITED STATES · built 1954
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCLAYTON, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 29 July 2026 · expires 31 August 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Regulatory (Subpart C or D), Net Ton
63 - Displacement, Gross Ton
14 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

17 inspections, each with its date, unit and type; 14 deficiencies with the resolution recorded against each; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 17

30 September 2024 Administrative Inspection
Administrative · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8012375
12 April 2024 Annual Inspection
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 7893521
27 September 2023 Internal Structural Exam
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7799447
7 August 2023 Administrative Inspection
Administrative · USCG Great Lakes District (dp) · USCG Great Lakes District (CGD-GL) · Activity 7762166
31 July 2023 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7757073
20 March 2023 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7653511
4 May 2022 Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7443033
10 May 2021 Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7193612
14 May 2020 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6955017
21 May 2019 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6689106
18 March 2019 Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6645099
5 September 2018 Administrative Inspection · Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6533607
7 August 2018 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6503480
31 May 2018 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6430479
2 April 2018 Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6383587
6 June 2017 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6173728
6 June 2016 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5899513

Deficiency record · 14

10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 April 2024 Resolved
(a)(i) Shapes shall be black and of the following sizes: A ball shall have a diameter of not less than 0.6 meter. Vessel did not have any ball day shapes onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2024
Resolved 12 April 2024
Resolution: Vessel owner texted verifying deficiency correction with pictures.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 April 2024 Resolved
46 CFR 176.25-10(b) At all inspections special attention shall be paid to insure that no fire hazards exist and that guards or protective devices are provided in all hazardous places. MI discovered lagging on vessels generator was soaked with oil.
Action required: 10 - Deficiency Rectified
Resolved 12 April 2024
Resolution: Vessel rep replaced lagging in kind
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 April 2023 Resolved
Filled water in voids 1 & 3 to test bilge pump. Bilge pump was insufficient at removing water in a timely manner. 182.25-10 Bilge pumps. (a) S and L. All vessels shall be provided with bilge pumps.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 April 2023
Resolution: Replaced bilge pump. All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 13 April 2023 Resolved
Engine room hatch gasket needs to be replaced. 179.360 Watertight integrity. (a) A hatch exposed to the weather must be watertight
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 May 2023
Resolved 18 April 2023
Resolution: Replaced gasket and chaulk tested, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 April 2023 Resolved
Port MDE exhaust elbow is leaking oil. Instructed owner/operator to clean and repair. 176.830(b): At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 April 2023
Resolution: Elbow flange was tightened and oil cleaned from surface.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 13 April 2023 Resolved
Life float was found with deterioration from the sun, cracks and holes in exterior coating. 185.700 Operational readiness. (a) Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 April 2023
Resolution: Repaired damaged areas using [name withheld] Repair Kit
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 April 2023 Resolved
Portable fire extinguishers are due for annual inspection by the end of April. 176.810 Fire protection. (a) At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following: (1) Inspection of each portable fire extinguisher, semiportable fire extinguisher, and fixed gas fire extinguishing system to check for excessive corrosion and general condition;
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 April 2023
Resolution: Northern Fire Equipment Company completed annual inspection of extinguishers, all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 April 2023 Resolved
FCC radio inspection for Great Lakes needs to be completed.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 April 2023
Resolution: Radio has been inspected and certificate received.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 April 2023 Resolved
Dead end wire found by port MDE Racor. Owner/operator needs to remove, cap, or place in junction box. 183.200(b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock;
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 April 2023
Resolution: Owner/operator removed wire from vessel.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 April 2023 Resolved
Fire axe handle was found deteriorated.
Action required: 10 - Deficiency Rectified
Resolved 13 April 2023
Resolution: Owner/operator installed new fire axe.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 April 2023 Resolved
MDE Battery connections were found to be loose. Generator battery had wing nuts instead of hex.
Action required: 10 - Deficiency Rectified
Resolved 13 April 2023
Resolution: MDE battery connections were tightened, and generator battery terminal wing nuts removed and replaced with hex nut.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 21 May 2019 Resolved
Found two 3" cracks in the cargo area deck just stbd of centerline into the #3 void. A sharp inset was also found in close proximity to the 2 cracks. Required 2 18"x18" inserts for the cracks and the inset.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 22 May 2019
Resolution: Witnessed dye-penetrant tests of two 18"x18" inserts. No leaks found.
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 21 May 2019 Resolved
Front pilot house window was found to have limited visibility due to scratches and haze guild up. Required new pilot house front window. 46 CFR 177.1030.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2019
Resolved 22 May 2019
Resolution: Owner install new pilot house front window.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 May 2019 Resolved
Portable fire extinguishers did not have the proper marine type brackets. Required all fire extinguishers to have marine type brackets.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2019
Resolved 5 June 2019
Resolution: Received text with pictures stating and showing marine type fire extinguisher brackets installed on board the vessel.

Casualty record · 1

19 June 2012Routine · role: Involved in a Marine Casualty · activity 4381561
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.