Records from 1989 to 2017. Most recent: inspection, 5 June 2017.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 7
5 June 2017
Deficiency Check
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 6170157
22 May 2017
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 6152787
20 June 2008
Ballast Water Examination · ISPS II Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 3242866
2 November 2004
ISPS II Exam · PII Safety Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2229967
19 October 1999
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 433860
30 July 1997
Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 406573
11 April 1989
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 329638
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 5 June 2017
No resolution recorded
The condition of the ship & its equipment shall be maintained to conform with thee provisions of the present regulations to ensure the ship can proceed to sea without danger to the ship or persons on board.
The vessels incinerator was not operating and is needed for sludge.
74SOLAS (97) Reg. 11(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2017 — due date passed with no resolution recorded
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 22 May 2017
Resolved
The condition of the ship & its equipment shall be maintained to confirm with the provisions of the present regulations to ensure the ship can proceed to sea without danger to the ship or persons on board.
The vessel's engine room has exessive accumilation of oil in the bilge, presenting a fire hazard. 74 SOLAS (97) CH. I Reg 11(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 May 2017
Resolved 5 June 2017
Resolution: Bilges were pumped out by Solar enviromental.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 22 May 2017
No resolution recorded
Means of escape shall be steel, insulatedwhere necessary.
Insulation in the engine room escape trunk is worn.
74SOLAS (97)CH.II-2, Reg. 45-3.1
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 May 2017 — due date passed with no resolution recorded
Fire Fighting › Structural - A Class Divisions › Control Stations
Issued 22 May 2017
No resolution recorded
The condition of the ship & its equipment shall be maintained to confirm with the provisions of the present regulations to ensure the ship can proceed to sea without danger to the ship or persons on board.
The deck in the Engine Control Room has wasted through.
74 SOLAS (97) CH. I Reg 11(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 May 2017 — due date passed with no resolution recorded
Lifesaving › Lifeboat › Hatches
Issued 20 June 2008
No resolution recorded
On both and starboard lifeboats, the sea painter hatches (fore & aft) leak. Replace gasket in each hatch.
Action required: 705 - Other - as specified
Lifesaving › Lifeboat › Markings
Issued 20 June 2008
No resolution recorded
Repalce, as necessary, retro reflective tape on outside of lifeboats.
Action required: 705 - Other - as specified
Engineering
Issued 30 July 1997
Resolved
Stbd side aft f/o vent was crushed and needed repair._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 August 1997
Resolved 6 August 1997
Unknown
Issued 30 July 1997
Resolved
Remove excess cardboard boxes from engine room.
Condition: Unknown
Due 6 August 1997
Resolved 6 August 1997
Unknown
Issued 30 July 1997
Resolved
Steering room contained excess debris, boxes and rubbish.
Condition: Unknown
Due 6 August 1997
Resolved 6 August 1997
Lifesaving
Issued 30 July 1997
Resolved
55 gal drums found on deck had no closures causing potential for pollution.Master was advised to move drums to a safer place to prevent pollution incident.
Condition: Unknown
Due 6 August 1997
Resolved 6 August 1997
Engineering
Issued 30 July 1997
Resolved
All fuel tank vent containment areas were missing a drain plugs._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 August 1997
Resolved 6 August 1997
Engineering
Issued 30 July 1997
Resolved
Port side fwd fuel vent missing 2 bolts on 6 bolt flange.
Condition: Unknown
Due 6 August 1997
Resolved 6 August 1997