EXCEL

EXCEL is a 1989 passenger vessel (inspected). The Coast Guard has recorded 33 inspections since 2016, most recently in April 2026, along with 74 deficiencies and 4 casualty investigations between 2006 and 2023.

Records from 2006 to 2026. Most recent: inspection, 7 April 2026.

Built
1989
Last inspected
7 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 April 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8654560
WDH8776
329138
Flag
UNITED STATES
Maury page id
psix-329138

Documentation record

Registered dimensions (L × B × D)109.1 ft × 31.0 ft × 6.3 ft
Registered tonnagegross 98 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF COAST MARINE · HOUMA, LA, UNITED STATES · built 1989
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 18 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 33

7 April 2026 COI Inspection · Deficiency Check · MTSA/ISPS Verification · MSP Additional Oversight - Risk Assessment
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8320377
17 February 2026 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8292073
8 October 2025 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8250006
14 April 2025 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8111740
13 February 2025 Examination of Repairs · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8079111
25 October 2024 Deficiency Check · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8027025
25 July 2024 Bulk Liquid Transfer Monitor
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7967204
16 April 2024 Administrative Inspection · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7889571
28 February 2024 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7871886
26 February 2024 Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7870212
3 September 2023 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7814718
21 April 2023 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7668654
21 April 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7674231
24 February 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7641683
6 January 2023 Appeal · Administrative Inspection · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7620340
2 November 2022 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7588683
14 April 2022 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7412062
7 March 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7407193
22 September 2021 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7318454
19 April 2021 Deficiency Check · COI Inspection · MTSA/ISPS Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7181705
1 March 2021 Drydock Exam · Examination of Repairs · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7148428
15 April 2020 MTSA/ISPS Verification · COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6939480
24 February 2020 Deficiency Check · Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6914373
19 October 2019 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6824830
15 April 2019 COI Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6662627
28 February 2019 Drydock Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6634458
25 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6548004
14 April 2018 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6391494
29 March 2018 Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6389822
11 April 2017 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6118244
24 February 2017 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6094071
11 April 2016 COI Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5844322
26 February 2016 Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5822198

Deficiency record · 74

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 April 2026 Resolved
Smoke & Fire detection system missing. Install smoke & fire detectors in bridge, passenger berthing, and accommodation passageway (3). Vessel not permitted to carry passengers until detectors are installed and verified by inspectors.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 April 2026
Resolution: MI attended vessel to condect test, all sat.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 7 April 2026 Resolved
Fuel shutoff system obstructed. Install guards to protect cables for fuel shutoff system to ensure system functions properly.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2026
Resolved 11 May 2026
Resolution: Received photo of def corrected. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 April 2026 Resolved
Bilge system. Replace flexible hose on primary bilge piping in engine room. Remove excess water from engine room bilge and provide evidence of the installation of limber holes in longitudinal frames near bilge before determining the acceptability of plastic piping in bilge system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2026
Resolved 11 May 2026
Resolution: Received photo of def corrected. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 April 2026 Resolved
Ring life buoy deteriorated beyond use. Replace ring life buoy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2026
Resolved 14 April 2026
Resolution: MI attended vessel, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 April 2026 Resolved
Fire station missing critical equipment. Supply each fire station with a functioning spanner wrench.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2026
Resolved 14 April 2026
Resolution: MI attended vessel, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 April 2026 Resolved
Electrical fixtures. Cover to electrical panel on bridge missing. Install cover.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2026
Resolved 11 May 2026
Resolution: Received photo of def corrected. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 19 May 2025 Resolved
Vessel was unable to pump the fore-peak bilge using the installed bilge system. Troubleshoot system and prove proper operation. -Prior to carrying passengers-
Action required: 705 - Other - as specified
Resolved 20 May 2025
Resolution: Vessel's crew identified and repaired a leaking union fitting.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 May 2025 Resolved
Provide all fire stations with a spanner wrench.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 May 2025
Resolution: Received photo's of new spanner wrenches.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 19 May 2025 Resolved
Provide aft stateroom escape hatch with proper labeling on both sides of the hatch.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 May 2025
Resolution: Received photo of new placards.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 May 2025 Resolved
Provide engine room CO2 pull handle with instructions.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 May 2025
Resolution: Received photo of new placard.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 May 2025 Resolved
All griddles, broilers, and deep fat fryers must be fitted with a grease extraction hood in compliance with 181.425. A grease extraction hood must meet UL 710 or other standard specified by the Commandant. A grease extraction hood must be equipped with a dry or wet chemical fire extinguishing system meeting NFPA 17 or other standard specified by the Commandant, and must be listed by an independent laboratory recognized by the Commandant. Install grease extraction hood equipped with a dry or wet chemical fire extinguishing system to the satisfaction of an attending marine inspector at next credit dock.
Action required: 705 - Other - as specified
Resolved 7 April 2026
Resolution: Vessel has installed grease hood extraction system. All SAT.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 13 February 2025 Resolved
Vessel is in dry dock and has not completed IFR / Egress modifications or drills. Vessel is prohibited from carrying overnight passengers or allowing passengers in the bunk rooms until modifications are made and an egress drill is completed.
Action required: 705 - Other - as specified
Resolved 19 May 2025
Resolution: Witnessed satisfactory egress drill and inspected approved modifications.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 13 February 2025 Resolved
Submit repair proposal for wasted stbd / aft overboard discharge side-shell and piping in the pump room.
Action required: 705 - Other - as specified
Resolved 20 May 2025
Resolution: Area was welded and repaired.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 13 February 2025 Resolved
Pump room deck plating framing was found to be wasted, renew to new steel.
Action required: 705 - Other - as specified
Resolved 20 May 2025
Resolution: Areas were welded and repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 October 2024 Resolved
Vessel's generator experienced an overheating condition and was secured by the crew. Troubleshoot and make repairs to generator.
Action required: 705 - Other - as specified
Resolved 27 October 2024
Resolution: Failure was identified as the water pump and associated drive unit. Parts replaced and operationally tested.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 April 2024 Resolved
All griddles, broilers, and deep fat fryers must be fitted with a grease extraction hood in compliance with 181.425. A grease extraction hood must meet UL 710 or other standard specified by the Commandant. A grease extraction hood must be equipped with a dry or wet chemical fire extinguishing system meeting NFPA 17 or other standard specified by the Commandant, and must be listed by an independent laboratory recognized by the Commandant. Install grease extraction hood equipped with a dry or wet chemical fire extinguishing system to the satisfaction of an attending marine inspector at next credit drydock, no later than Jan 1, 2026.
Action required: 705 - Other - as specified
Resolved 7 April 2026
Resolution: Vessel has installed grease hood extraction system. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 16 April 2024 Resolved
At each inspection all observed unsafe practices and all required guards and protective devices must be in satisfactory condition. On the two port side refers in the galley, the emergency escape latch was missing. Replace emergency escape hatch for the reefers. Until this situation is remedied, include a reefer check in each round and log it in the log book. Replace and send pictures to clear.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 May 2024
Resolution: Installed escape latch.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 16 April 2024 Resolved
At each inspection all observed unsafe practices and all required guards and protective devices must be in satisfactory condition. Fan guard in pump room was missing a guard. Replace and send pictures to clear.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 April 2024
Resolution: Installed guard
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 April 2024 Resolved
Electrical equipment must be installed and maintained to minimize accidental personnel contact with energized parts and protect passengers, crew, other persons and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment and electrical shock. 1. The junction box in the tuna tower needs to be mounted. Mount and send pictures to clear 2. Multiple exposed wires were found not properly dead ended in the wheel house. Dead end exposed wires and send pictures to clear.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 April 2024
Resolution: Mounted J-Box
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 26 February 2024 Resolved
Upon completion of bilge sandblasting, request marine inspector attendance to inspect.
Action required: 705 - Other - as specified
Resolved 11 April 2024
Resolution: The aft bulkhead of the engine room was holed while sandblasting and area was cropped and renewed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 April 2023 Resolved
Complete but simple instructions for the operation of a fixed gas fire extinguishing system must be located in a conspicuous place at or near each pull box and stop valve control and in the space where the extinguishing agent cylinders are stored. Vessel was found without instructions, provide permanent instructions at the CO2 pull box.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2023
Resolved 24 April 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 April 2023 Resolved
Fuel filters other than steel construction must be fitted with a flame impingement bowl. Vessel’s fuel piping to fuel system purifier was found with a plastic filter without a flame bowl, provide piping with an approved flame bowl or steel construction filter.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2023
Resolved 24 April 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 April 2023 Resolved
Electrical wiring must be installed to protect against electrical hazards and electrical shock. Vessel’s galley reefer was found to have an tapped electrical splice in the overhead, provide electrical connection with proper junction box.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2023
Resolved 24 April 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 April 2023 Resolved
An oceans route vessel must have an orange life ring buoy. Vessel’s forward life ring buoy was found to be faded and sun damaged, provide the forward life ring with proper replacement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2023
Resolved 24 April 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2022 Resolved
Fire pump motor electrical cable fitting loose. Repair
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 April 2022
Resolved 16 April 2022
Resolution: Corrected on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2022 Resolved
Engine room vent controller cable connector missing. Repair
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 28 April 2022
Resolved 14 April 2022
Resolution: Corrected on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2022 Resolved
Electrical panel enclosure not properly sealed. Repair.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 28 April 2022
Resolved 14 April 2022
Resolution: Corrected on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2022 Resolved
Electrical cable entering panel enclosure missing fitting. Repair.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2022
Resolved 15 April 2022
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2022 Resolved
Electrical cable entering auxilairy pump cable loose. Repair.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 April 2022
Resolved 14 April 2022
Resolution: Corrected on the spot.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 19 April 2021 Resolved
Provide metal waste receptacle in Galley.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2021
Resolved 19 May 2021
Resolution: Visually inspected rectified def on board.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 19 April 2021 Resolved
Provide Smoke detector in each state room/ accommodation room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2021
Resolved 19 May 2021
Resolution: Visually inspected rectified def on board.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 19 April 2021 Resolved
Provide "Restricted Area" Markings at both means of access to the bridge/ Wheel house.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2021
Resolved 19 May 2021
Resolution: Visually inspected rectified def on board.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 19 April 2021 Resolved
Install gasket at Engine Room emergency escape hatch.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2021
Resolved 19 May 2021
Resolution: Visually inspected rectified def on board.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 April 2020 Resolved
FIRE HOSE NOZZLES MUST BE CONSTRUCTED OF EITHER BRASS OR BRONZE. REPLACE PORT FWD FIRE NOZZLE.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2020
Resolved 20 April 2020
Resolution: replaced with brass nozzle.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 15 April 2020 Resolved
LAZERATTE BILGE ALARM DID NOT GIVE AN AUDIBLE ALARM DURING TESTING. ENSURE ALARM GIVES BOTH A VISUAL AND AUDIBLE INDICATION AT THE OPERATING STATION.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2020
Resolved 20 April 2020
Resolution: audible and visual means on bridge operational
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 April 2020 Resolved
REPLACE RETRO REFELCTIVE TAPE ON AFT LIFE RING.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2020
Resolved 20 April 2020
Resolution: replaced retro tape
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 15 April 2020 Resolved
SECURE DECK PLATE IN PUMP ROOM TO MINIMIZE HAZARDS TO PERSONNEL.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2020
Resolved 20 April 2020
Resolution: Secured plate
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 October 2019 Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
Action required: 705 - Other - as specified
Due 17 January 2020
Resolved 20 April 2020
Resolution: Verified submitted diagram.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 October 2019 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, and vessel from electrical hazards. Correct the following: 1) Extension cords used as permanent wiring in crew space and in wheelhouse. 2) Dead-end wires found at refer on top deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2019
Resolved 6 November 2019
Resolution: Def rectified to the satisfaction of the CG Marine Inspector
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 April 2019 Resolved
Submit drawings and plans for approval of fixed firefighting system to [name withheld] had been made to the system including changing of agent from Halon to clean agent and addition of nitrogen bottle. Prior to carrying passengers.
Action required: 705 - Other - as specified
Resolved 24 April 2019
Resolution: Plans submitted to MSC.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 April 2019 Resolved
Amend security plan to meet baggage screeing as trained on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2019
Resolved 31 May 2019
Resolution: Security plan updated to show proper screening.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 April 2019 Resolved
Provide closure means for bilge piping that pierces collision bulkhead.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2019
Resolved 23 April 2019
Resolution: Vessel rep discovered the a valve was installed and proved operation of it.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 15 April 2019 Resolved
Provide proper placard for new fixed fire agent.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2019
Resolved 23 April 2019
Resolution: Warning placards were properly installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 April 2019 Resolved
Provide lifering and ensure all rings have retro tape per COI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2019
Resolved 23 April 2019
Resolution: Vessel purchased and installed new lifering.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 April 2019 Resolved
Provide fire nozzle's that meet NFPA 1963 and are able to change between solid stream and spray pattern.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2019
Resolved 23 April 2019
Resolution: Vessel rep purchased and installed 03 vari-nozzles.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 April 2019 Resolved
Conduct hourly rounds of engine room and log each round. Provide log to Sector San Diego upon return to port.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 June 2019
Resolution: Vessel recieved approval for fixed fire fighting.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 April 2019 Resolved
Report status of voyage to SAC for relay to Sector San Diego once a day.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 June 2019
Resolution: Fixed firefighting approved.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 25 September 2018 Resolved
MMSI: Vsl is broadcasting MMSI from expired FCC License, CLSN: Vsl is broadcasting Call Sign from expired FCC License, IMO: Vsl is broadcasting no IMO #,
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 4 February 2019
Resolution: Verified in VIVS.
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 14 April 2018 Resolved
L/O was found to be conatminted making the L/O look like chocolate milk.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 May 2018
Resolved 19 April 2018
Engineering › Bilge Water Management System › Piping
Issued 14 April 2018 Resolved
Provide check valves to the bilge piping system.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 May 2018
Resolved 19 April 2018
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 14 April 2018 Resolved
Provide fire servicing report.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 May 2018
Resolved 19 April 2018
Electrical › Electrical Distribution System (service) › Junction Box
Issued 14 April 2018 Resolved
Close up open junction boxes.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2018
Resolved 19 April 2018
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 14 April 2018 Resolved
Close up open ended piping systems in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2018
Resolved 19 April 2018
Engineering › Fuel Oil Service System › Valve
Issued 14 April 2018 Resolved
Demonstrate proper operation of the emergency fuel stops.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2018
Resolved 19 April 2018
Electrical › Lighting (service) › Lighting Fixture
Issued 14 April 2018 Resolved
Provide proper guards for light fixtures in the engine room.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2018
Resolved 19 April 2018
Operations/Management › Drills/Instruction › Not Conducted
Issued 14 April 2018 Resolved
Conduct U/W drills.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2018
Resolved 19 April 2018
Electrical › Electric Generation Source (service) › Conductor
Issued 29 March 2018 Resolved
Install proper wire mounts in pump room.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2018
Resolved 17 April 2018
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 29 March 2018 Resolved
Renew or remove air reciever in the engine room starboard side
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2018
Resolution: Reciever in engine room was renewed.
Construction/Loadline › Hull › Bottom Plating
Issued 29 March 2018 Resolved
De-scale areas of hull plating identified by Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2018
Resolution: 02 Hull inserts installed on portside forward of the aft bulkhead and starboard side IVO workbench. Both inserts were approx 18" X 36".
Construction/Loadline › Hull › Stiffener
Issued 29 March 2018 Resolved
Crop and renew holed out vertical frames identified in aft lazzerette.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2018
Resolution: 02 Frames renewed aprox 4'
Construction/Loadline › Hull › Bottom Plating
Issued 29 March 2018 Resolved
De-scale corroded hull plating IVO portside pump room
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2018
Resolution: The areas of concern are within tolerances.
Construction/Loadline › Hull › Longitudinal Frame
Issued 29 March 2018 Resolved
Crop and renew all holed out frames in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2018
Resolution: Renewed approx 20' of framing in the Engine Room.
Construction/Loadline › Hull › Hull Plating
Issued 29 March 2018 Resolved
Crop and renew holed out plating in windlass compartment.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2018
Resolution: 02 small inserts were installed port and starboard side IVO windlass compartment.
Construction/Loadline › Hull › Longitudinal Frame
Issued 29 March 2018 Resolved
Renewe all corroded frames in windlass compartment.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 April 2018
Resolution: Approx 6' of wasted frames were renewed in the windlass compartment
Engineering › Bilge Water Management System › Piping
Issued 29 March 2018 Resolved
Renew bilge piping stbd aft and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2018
Resolution: Approx 8' of bilge piping renewed to be tested during COI.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 11 April 2017 Resolved
Provide drug testing kits.
Due 11 May 2017
Resolved 21 April 2017
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 11 April 2017 Resolved
Provide current STCW medical certification/card for [name withheld] prior to him filling Master position on international voyages.
Action required: 705 - Other - as specified
Resolved 11 April 2018
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 April 2017 Resolved
Remove dead-end wires under the bridge counsel.
Due 11 May 2017
Resolved 21 April 2017
Engineering › Sea-water System (primary cooling) › Piping
Issued 11 April 2017 Resolved
Port main engine R/W inlet pipe has a hole wrapped with syntho glass tape. Renew or repair pipe to the satisfaction of the attending CGMI prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2017
Engineering › Sea-water System (primary cooling) › Piping
Issued 11 April 2017 Resolved
Center R/W pipe, main engine; secure loose pipeprior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2017
Engineering › Sea-water System (primary cooling) › Piping
Issued 11 April 2017 Resolved
STBD generator; R/W hose, inlet to pump, is kinking is starting to deteriorate. Renew hose prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2017
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 April 2017 Resolved
Provide corrosion resistant clip for life ring water light.
Due 11 May 2017
Resolved 21 April 2017
Fire Fighting › Fire Hoses › Material
Issued 11 April 2017 Resolved
Provide one fire hose at station #2.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2017
Engineering › Fuel Oil Service System › Filter
Issued 11 April 2017 Resolved
Provide metallic fittings for all Raycor flame shield/bowls.
Due 11 May 2017
Resolved 21 April 2017

Casualty record · 4

28 May 2006Routine · role: Involved in a Marine Casualty · activity 2666251
24 October 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 3877024
15 June 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4053826
3 September 2023Routine · role: Involved in a Marine Casualty · activity 7814718
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.