← All vessels
EXCEL
Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG Southwest District (CGD-SW) · Other hulls named EXCEL
EXCEL is a 1989 passenger vessel (inspected). The Coast Guard has recorded 123 inspections since 1990, most recently in April 2026, along with 231 deficiencies and 4 casualty investigations between 2006 and 2023.
Records from 1990 to 2026. Most recent: inspection, 7 April 2026.
- Built
- 1989
- Last inspected
- 7 April 2026
- Documentation
- Case Pending · documentation file of 10 September 2026
- Inspections
- 123
- Deficiencies
- 231 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 4 investigations · 2006–2023
Identity
947538
8654560 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDH8776
329138
Flag
UNITED STATES
338102000
Maury page id
psix-329138
Inspections, by type
…with no type recorded22
Years with a record
35 calendar years (1990–2026)
The 123 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)108.3 ft × 31.0 ft × 13.5 ft
Registered tonnagegross 98 / net 66
ITC dimensions (L × B × D)108.3 ft × 31.0 ft × 13.5 ft
ITC tonnagegross 280 / net 84
BuilderGULF COAST MARINE · HOUMA, LA, UNITED STATES · built 1989
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationCase Pending · issued 18 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDH8776MMSI 338102000 · active · compulsorily equipped · granted 17 December 2024, expires 14 March 2035
WAI6503MMSI 366547000 · expired · compulsorily equipped · granted 3 December 2004, cancelled 11 April 2015
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 123
7 April 2026
COI Inspection · Deficiency Check · MTSA/ISPS Verification · MSP Additional Oversight - Risk Assessment
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8320377
17 February 2026
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8292073
8 October 2025
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8250006
14 April 2025
Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8111740
13 February 2025
Examination of Repairs · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8079111
25 October 2024
Deficiency Check · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8027025
25 July 2024
Bulk Liquid Transfer Monitor
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7967204
16 April 2024
Administrative Inspection · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7889571
28 February 2024
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7871886
26 February 2024
Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7870212
3 September 2023
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7814718
21 April 2023
COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7668654
21 April 2023
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7674231
24 February 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7641683
6 January 2023
Appeal · Administrative Inspection · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7620340
2 November 2022
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7588683
14 April 2022
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7412062
7 March 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7407193
22 September 2021
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7318454
19 April 2021
Deficiency Check · COI Inspection · MTSA/ISPS Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7181705
1 March 2021
Drydock Exam · Examination of Repairs · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7148428
15 April 2020
MTSA/ISPS Verification · COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6939480
24 February 2020
Deficiency Check · Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6914373
19 October 2019
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6824830
15 April 2019
COI Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6662627
28 February 2019
Drydock Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6634458
25 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6548004
14 April 2018
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6391494
29 March 2018
Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6389822
11 April 2017
COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6118244
24 February 2017
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6094071
11 April 2016
COI Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5844322
26 February 2016
Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5822198
13 June 2014
Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4885942
16 February 2012
Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4222141
8 August 2011
MTSA/ISPS Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4109772
17 February 2011
Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3932849
2 November 2010
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3883224
24 October 2010
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3877024
18 March 2010
DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3658980
18 February 2010
Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3658947
25 February 2009
Internal Structural Exam · Construction Oversight · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3446263
13 February 2009
COI Inspection · MTSA/ISPS Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3413623
14 July 2008
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3267812
10 June 2008
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3232651
7 January 2008
COI Inspection · Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3126346
29 March 2007
COI Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2895742
5 March 2007
Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2879268
16 January 2007
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2893030
29 May 2006
Deficiency Check · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2663763
28 May 2006
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2666251
14 March 2006
Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2599485
27 February 2006
COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2583219
3 May 2005
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2348189
2 May 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2347343
11 April 2005
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2331419
16 March 2005
Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2285552
28 February 2005
COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2300650
11 June 2004
MTSA/ISPS Verification
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2095458
27 May 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2080128
29 April 2004
In-Service Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2055452
24 March 2004
Security Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2030704
11 March 2004
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2022954
1 March 2004
Deficiency Check · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1983277
30 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1972284
1 May 2003
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1784329
1 April 2003
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1766483
20 March 2002
Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1495133
19 March 2002
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1494748
5 March 2002
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1490866
11 February 2002
Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1485672
31 July 2001
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1069370
9 May 2001
Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1064760
29 March 2001
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 206977
29 March 2001
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 763761
16 March 2001
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1382179
5 March 2001
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1401423
1 July 2000
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 15775
17 May 2000
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1049900
13 April 2000
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1432322
13 March 2000
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1415320
5 March 2000
Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1046294
16 July 1999
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 155764
2 April 1999
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1441493
26 February 1999
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1408262
14 August 1998
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 171988
26 June 1998
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1131503
6 May 1998
Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 790363
13 April 1998
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1455592
23 March 1998
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1398894
15 August 1997
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 188730
30 June 1997
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 8134
29 April 1997
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1092633
19 March 1997
Deficiency Check · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1413138
6 March 1997
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1364076
27 January 1997
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 212438
24 November 1996
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 45824
2 April 1996
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1355804
8 March 1996
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1396467
26 April 1995
COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1392251
6 October 1994
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 80652
1 April 1994
Hull Examination · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1401832
11 September 1993
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 163110
9 April 1993
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 831816
22 March 1993
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 677156
19 March 1993
Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1146019
18 March 1993
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 79984
17 March 1993
COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1385036
11 May 1992
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1263623
30 March 1992
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1387250
27 March 1992
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1319189
18 March 1992
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1262969
26 April 1991
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 932947
26 April 1991
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1000094
23 April 1991
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1236408
17 April 1991
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1223242
14 March 1991
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 912264
5 March 1991
Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 934868
19 February 1991
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 911803
15 January 1991
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 918716
30 August 1990
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1229025
20 April 1990
Initial Certification
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 921127
15 February 1990
Hull Examination · Initial Construction-Excluding Oversight · Inclining Experiment · Plan Review "T" Boat
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1242097
Deficiency record · 231
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 April 2026
Resolved
Smoke & Fire detection system missing. Install smoke & fire detectors in bridge, passenger berthing, and accommodation passageway (3). Vessel not permitted to carry passengers until detectors are installed and verified by inspectors.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 7 April 2026
Resolved
Fuel shutoff system obstructed. Install guards to protect cables for fuel shutoff system to ensure system functions properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 April 2026
Resolved
Bilge system. Replace flexible hose on primary bilge piping in engine room. Remove excess water from engine room bilge and provide evidence of the installation of limber holes in longitudinal frames near bilge before determining the acceptability of plastic piping in bilge system.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 April 2026
Resolved
Ring life buoy deteriorated beyond use. Replace ring life buoy.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 April 2026
Resolved
Fire station missing critical equipment. Supply each fire station with a functioning spanner wrench.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 April 2026
Resolved
Electrical fixtures. Cover to electrical panel on bridge missing. Install cover.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 19 May 2025
Resolved
Vessel was unable to pump the fore-peak bilge using the installed bilge system. Troubleshoot system and prove proper operation. -Prior to carrying passengers-
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 May 2025
Resolved
Provide all fire stations with a spanner wrench.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 19 May 2025
Resolved
Provide aft stateroom escape hatch with proper labeling on both sides of the hatch.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 May 2025
Resolved
Provide engine room CO2 pull handle with instructions.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 May 2025
Resolved
All griddles, broilers, and deep fat fryers must be fitted with a grease extraction hood in compliance with 181.425. A grease extraction hood must meet UL 710 or other standard specified by the Commandant. A grease
extraction hood must be equipped with a dry or wet chemical fire extinguishing system meeting NFPA 17 or other standard specified by the Commandant, and must be listed by an independent laboratory recognized by
the Commandant. Install grease extraction hood equipped with a dry or wet chemical fire extinguishing system to the satisfaction of an attending marine inspector at next credit dock.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 13 February 2025
Resolved
Vessel is in dry dock and has not completed IFR / Egress modifications or drills. Vessel is prohibited from carrying overnight passengers or allowing passengers in the bunk rooms until modifications are made and an egress drill is completed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 13 February 2025
Resolved
Submit repair proposal for wasted stbd / aft overboard discharge side-shell and piping in the pump room.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 13 February 2025
Resolved
Pump room deck plating framing was found to be wasted, renew to new steel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 October 2024
Resolved
Vessel's generator experienced an overheating condition and was secured by the crew. Troubleshoot and make repairs to generator.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 April 2024
Resolved
All griddles, broilers, and deep fat fryers must be fitted with a grease extraction hood in compliance with 181.425. A grease extraction hood must meet UL 710 or other standard specified by the Commandant. A grease
extraction hood must be equipped with a dry or wet chemical fire extinguishing system meeting NFPA 17 or other standard specified by the Commandant, and must be listed by an independent laboratory recognized by
the Commandant. Install grease extraction hood equipped with a dry or wet chemical fire extinguishing system to the satisfaction of an attending marine inspector at next credit drydock, no later than Jan 1, 2026.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 16 April 2024
Resolved
At each inspection all observed unsafe practices and all required guards and protective devices must be in satisfactory condition. On the two port side refers in the galley, the emergency escape latch was missing.
Replace emergency escape hatch for the reefers. Until this situation is remedied, include a reefer check in each round and log it in the log book. Replace and send pictures to clear.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 16 April 2024
Resolved
At each inspection all observed unsafe practices and all required guards and protective devices must be in satisfactory condition. Fan guard in pump room was missing a guard. Replace and send pictures to clear.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 April 2024
Resolved
Electrical equipment must be installed and maintained to minimize accidental personnel contact with energized parts and protect passengers, crew, other persons and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment and electrical shock.
1. The junction box in the tuna tower needs to be mounted. Mount and send pictures to clear
2. Multiple exposed wires were found not properly dead ended in the wheel house. Dead end exposed wires and send pictures to clear.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 26 February 2024
Resolved
Upon completion of bilge sandblasting, request marine inspector attendance to inspect.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 April 2023
Resolved
Complete but simple instructions for the operation of a fixed gas fire extinguishing system must be located in a conspicuous place at or near each pull box and stop valve control and in the space where the extinguishing agent cylinders are stored. Vessel was found without instructions, provide permanent instructions at the CO2 pull box.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 April 2023
Resolved
Fuel filters other than steel construction must be fitted with a flame impingement bowl. Vessel’s fuel piping to fuel system purifier was found with a plastic filter without a flame bowl, provide piping with an approved flame bowl or steel construction filter.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 April 2023
Resolved
Electrical wiring must be installed to protect against electrical hazards and electrical shock. Vessel’s galley reefer was found to have an tapped electrical splice in the overhead, provide electrical connection with proper junction box.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 April 2023
Resolved
An oceans route vessel must have an orange life ring buoy. Vessel’s forward life ring buoy was found to be faded and sun damaged, provide the forward life ring with proper replacement.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2022
Resolved
Fire pump motor electrical cable fitting loose. Repair
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2022
Resolved
Engine room vent controller cable connector missing. Repair
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2022
Resolved
Electrical panel enclosure not properly sealed. Repair.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2022
Resolved
Electrical cable entering panel enclosure missing fitting. Repair.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2022
Resolved
Electrical cable entering auxilairy pump cable loose. Repair.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 19 April 2021
Resolved
Provide metal waste receptacle in Galley.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 19 April 2021
Resolved
Provide Smoke detector in each state room/ accommodation room.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 19 April 2021
Resolved
Provide "Restricted Area" Markings at both means of access to the bridge/ Wheel house.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 19 April 2021
Resolved
Install gasket at Engine Room emergency escape hatch.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 April 2020
Resolved
FIRE HOSE NOZZLES MUST BE CONSTRUCTED OF EITHER BRASS OR BRONZE. REPLACE PORT FWD FIRE NOZZLE.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 15 April 2020
Resolved
LAZERATTE BILGE ALARM DID NOT GIVE AN AUDIBLE ALARM DURING TESTING. ENSURE ALARM GIVES BOTH A VISUAL AND AUDIBLE INDICATION AT THE OPERATING STATION.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 April 2020
Resolved
REPLACE RETRO REFELCTIVE TAPE ON AFT LIFE RING.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 15 April 2020
Resolved
SECURE DECK PLATE IN PUMP ROOM TO MINIMIZE HAZARDS TO PERSONNEL.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 October 2019
Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 October 2019
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, and vessel from electrical hazards. Correct the following: 1) Extension cords used as permanent wiring in crew space and in wheelhouse. 2) Dead-end wires found at refer on top deck.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 April 2019
Resolved
Submit drawings and plans for approval of fixed firefighting system to [name withheld] had been made to the system including changing of agent from Halon to clean agent and addition of nitrogen bottle. Prior to carrying passengers.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 April 2019
Resolved
Amend security plan to meet baggage screeing as trained on board.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 April 2019
Resolved
Provide closure means for bilge piping that pierces collision bulkhead.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 15 April 2019
Resolved
Provide proper placard for new fixed fire agent.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 April 2019
Resolved
Provide lifering and ensure all rings have retro tape per COI.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 April 2019
Resolved
Provide fire nozzle's that meet NFPA 1963 and are able to change between solid stream and spray pattern.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 April 2019
Resolved
Conduct hourly rounds of engine room and log each round. Provide log to Sector San Diego upon return to port.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 April 2019
Resolved
Report status of voyage to SAC for relay to Sector San Diego once a day.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 25 September 2018
Resolved
MMSI: Vsl is broadcasting MMSI from expired FCC License, CLSN: Vsl is broadcasting Call Sign from expired FCC License, IMO: Vsl is broadcasting no IMO #,
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 14 April 2018
Resolved
L/O was found to be conatminted making the L/O look like chocolate milk.
Engineering › Bilge Water Management System › Piping
Issued 14 April 2018
Resolved
Provide check valves to the bilge piping system.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 14 April 2018
Resolved
Provide fire servicing report.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 14 April 2018
Resolved
Close up open junction boxes.
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 14 April 2018
Resolved
Close up open ended piping systems in the engine room.
Engineering › Fuel Oil Service System › Valve
Issued 14 April 2018
Resolved
Demonstrate proper operation of the emergency fuel stops.
Electrical › Lighting (service) › Lighting Fixture
Issued 14 April 2018
Resolved
Provide proper guards for light fixtures in the engine room.
Operations/Management › Drills/Instruction › Not Conducted
Issued 14 April 2018
Resolved
Conduct U/W drills.
Electrical › Electric Generation Source (service) › Conductor
Issued 29 March 2018
Resolved
Install proper wire mounts in pump room.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 29 March 2018
Resolved
Renew or remove air reciever in the engine room starboard side
Construction/Loadline › Hull › Bottom Plating
Issued 29 March 2018
Resolved
De-scale areas of hull plating identified by Marine Inspector
Construction/Loadline › Hull › Stiffener
Issued 29 March 2018
Resolved
Crop and renew holed out vertical frames identified in aft lazzerette.
Construction/Loadline › Hull › Bottom Plating
Issued 29 March 2018
Resolved
De-scale corroded hull plating IVO portside pump room
Construction/Loadline › Hull › Longitudinal Frame
Issued 29 March 2018
Resolved
Crop and renew all holed out frames in the engine room.
Construction/Loadline › Hull › Hull Plating
Issued 29 March 2018
Resolved
Crop and renew holed out plating in windlass compartment.
Construction/Loadline › Hull › Longitudinal Frame
Issued 29 March 2018
Resolved
Renewe all corroded frames in windlass compartment.
Engineering › Bilge Water Management System › Piping
Issued 29 March 2018
Resolved
Renew bilge piping stbd aft and prove proper operation.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 11 April 2017
Resolved
Provide drug testing kits.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 11 April 2017
Resolved
Provide current STCW medical certification/card for [name withheld] prior to him filling Master position on international voyages.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 April 2017
Resolved
Remove dead-end wires under the bridge counsel.
Engineering › Sea-water System (primary cooling) › Piping
Issued 11 April 2017
Resolved
Port main engine R/W inlet pipe has a hole wrapped with syntho glass tape. Renew or repair pipe to the satisfaction of the attending CGMI prior to carrying passengers.
Engineering › Sea-water System (primary cooling) › Piping
Issued 11 April 2017
Resolved
Center R/W pipe, main engine; secure loose pipeprior to carrying passengers.
Engineering › Sea-water System (primary cooling) › Piping
Issued 11 April 2017
Resolved
STBD generator; R/W hose, inlet to pump, is kinking is starting to deteriorate. Renew hose prior to carrying passengers.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 April 2017
Resolved
Provide corrosion resistant clip for life ring water light.
Fire Fighting › Fire Hoses › Material
Issued 11 April 2017
Resolved
Provide one fire hose at station #2.
Engineering › Fuel Oil Service System › Filter
Issued 11 April 2017
Resolved
Provide metallic fittings for all Raycor flame shield/bowls.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 18 March 2010
Resolved
25 Lifejackets lights failed inspection
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 18 March 2010
Resolved
Properly secure installed halon bottle
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 18 March 2010
Resolved
Install screws to properly secure covers to halon system pressure switch.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 18 March 2010
Resolved
Properly cap time delay discharge head
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 18 March 2010
Resolved
Renew batteries in the port and starboard pilothouse life buoys.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 18 March 2010
Resolved
Remove flammables from electical room or store all flammables in an approved lockef,
Construction/Loadline › Structures › Door
Issued 18 March 2010
Resolved
Properly adjust engineroom water tight door dogs
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 18 March 2010
Resolved
Provide rules of the road.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 18 March 2010
Resolved
Provide current tables
Construction/Loadline › Structures › Door
Issued 18 March 2010
Resolved
Label watertight door on both sides "Watertight door close in emergency"
Engineering › Fuel Oil Service System › Suction Strainer
Issued 18 March 2010
Resolved
Install metal heat shields to fuel filters (Racors)
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 18 March 2010
Resolved
Properly secure MSD overboard valve
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 18 March 2010
Resolved
Provide fuel tank vent flame screens
Electrical › Electric Generation Source (service) › Switch
Issued 18 March 2010
Resolved
Provide cover for light switch in the electrical room
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 18 March 2010
Resolved
Provide double hose clamps for exhaust system
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 March 2010
Resolved
Remove dead end wire in electrical room
Documentation › Certificates/Documents › FCC SSL
Issued 13 February 2009
Resolved
Provid FCC station license and safety certificate
Communications › Radio Communications › EPIRB
Issued 13 February 2009
Resolved
Weak link was missing approval tag. Vsl restricted to 3 NM until replacement of approved ink.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 13 February 2009
Resolved
All bilge alarm monitoring signals light upon activation of any float switch. Correct to proper operation prior to carrying passengers. Vsl is to provide roving monitor upon transit of vsl until corrected.
Engineering › Lubricating Oil Service System › Gauge
Issued 13 February 2009
Resolved
Center main diesel engine Lube oil pressure gauge is OOC. Repair before operation of engine.
Engineering › Fuel Oil Service System › Piping
Issued 13 February 2009
Resolved
Remove temporary synthetic putty patch on fuel manifold and prove integrity of piping to marine inspector during next dry-dock period.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 13 February 2009
Resolved
Non-conformity forms and Audits not being used correctly.
Operations/Management › Drills/Instruction › Not Conducted
Issued 13 February 2009
Resolved
Unable to produce sufficient record of quarterly emergency drills over the past year. Vsl must demonstrate ability to adequately perform drills in the presence, and to satisfaction of a CG Marine Inspector prior to carrying passengers.
Electrical › Lighting (service) › Conductor
Issued 7 January 2008
Resolved
Remove splice wiring in fwd peak
Electrical › Lighting (service) › Lighting Feeder
Issued 7 January 2008
Resolved
Cover open wires in Mast
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 7 January 2008
Resolved
Cover all exposed opens in the main Electrical box.
Engineering › Fuel Oil Service System › Filter
Issued 7 January 2008
Resolved
Repair fuel leak on main Racor
Engineering › Fuel Oil Service System › Hose
Issued 7 January 2008
Resolved
Replace hi/low hose on fuel day tank
Engineering › Fuel Oil Service System › Valve
Issued 7 January 2008
Resolved
Repair or replace emergency fuel shut off valve.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 7 January 2008
Resolved
Repair/replace 1 1/2 line going into the exhaust for the starboard eng
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 7 January 2008
Resolved
Repair leak on exhaust for the engine muffler in pump room
Engineering › Lubricating Oil Service System › Hose
Issued 7 January 2008
Resolved
Replace all hydraulic leaks in starboard side in the engine room
Construction/Loadline › Penetrations › Bottom Plug Packing
Issued 7 January 2008
Resolved
Replace sonar tube packing
Navigation › Piloting/Steering › Coast Guard Light List
Issued 7 January 2008
Resolved
Replace light list, and chart
Communications › Radio Communications › VHF Radiotelephone
Issued 7 January 2008
Resolved
Replace survival craft radio batteries
Fire Fighting › Fire Pumps › Pressure
Issued 7 January 2008
Resolved
Replace gauge or prove PSI
Fire Fighting › Fire Pumps › Pressure
Issued 29 March 2007
Resolved
Install pressure guage on fire pump at pump outlet.
Fire Fighting › Fire Main › Condition
Issued 29 March 2007
Resolved
Repair leaking fire main piping in E/R.
Communications › Radio Communications › EPIRB
Issued 29 March 2007
Resolved
Provide a properly installed and NOAA registered 406Mhz EPIRB. Vessel restricted to no more than 3NM from shore until corrected.
Fire Fighting › Ventilation Systems › Exhaust Ducts (Galley Ranges)
Issued 29 March 2007
Resolved
Clean grease build-up in galley hood ducting.
Lifesaving › Rescue Boat Equipment › First Aid Kit
Issued 29 March 2007
Resolved
Replace expired medications in first aid kit.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 29 March 2007
Resolved
Remove water, determine path of water inside stbd lifefloat waterlight, and repair or replace waterlight.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 29 March 2007
Resolved
Conduct and log man overboard and fire drills in designated log book. Ensure two (2) new crewmembers are trained in their respective duties prior to their first voyage.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 29 March 2007
Resolved
Repair inoperative emergency lights in fwd and aft berthing. No passengers until corrected.
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 29 March 2007
Resolved
Provide CPR refresher course for vessel crew.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 5 March 2007
Resolved
Clean around kinfe edge for forward hatch.
Electrical › Lighting (service) › Lighting Fixture
Issued 5 March 2007
Resolved
Repair lighting assembly in forward bulkhead compartment.
Deck/Cargo › Ballast › Piping
Issued 5 March 2007
Resolved
Repair hole in drain pipe in lower aft compartment
Deck/Cargo › Marine Portable Tanks › Securing Device
Issued 5 March 2007
Resolved
Provide permanent tied down for welding tanks.
Construction/Loadline › Hull › Side Shell
Issued 5 March 2007
Resolved
Determine wastage extend on stbd hull's hole near gallet drain.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 29 May 2006
Resolved
Provide technician inspection report of fitness to continue service following allision.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 27 February 2006
Resolved
Provide list of employees enrolled in vsl's drug testing program. Enroll all crewmembers (deckhands) with safety duties in program.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 27 February 2006
Resolved
Service portable fire ext in pump space.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 27 February 2006
Resolved
Repair electrical/light indicator panel on bridge.
Communications › Radio Communications › Satellite Communications Capability
Issued 27 February 2006
Resolved
Repair/prove operation of NAVTEX rcvr. Vsl restricted to voyages w/in 100nm of shore and not on an international voyage.
Navigation › Piloting/Steering › Marine Charts
Issued 27 February 2006
Resolved
Provide current paper charts for areas transited.
Navigation › Piloting/Steering › US Coast Pilot
Issued 27 February 2006
Resolved
Provide current Coast Pilot [name withheld], Tide Tables, and Tidal Current Tables.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 February 2006
Resolved
Repair stern light.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 27 February 2006
Resolved
Provide additional battery (spare) for emergency liferaft radios making a total of 3 spares.
Communications › Radio Communications › EPIRB
Issued 27 February 2006
Resolved
Mark vsl name on EPIRB.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 27 February 2006
Resolved
Label emergency escape on fwd berthing escape ladder.
Documentation › Certificates/Documents › International Tonnage Certificate
Issued 28 February 2005
Resolved
Have vessel measured to determine ITC applicability during next dry-dock.
Communications › Alarms/Indicators › Bilge Alarm
Issued 28 February 2005
Resolved
Repair bilge alarms in E/R and lazarette.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 28 February 2005
Resolved
Replace retro-reflective tape on lifejackets as needed.
Lifesaving › Lifebuoys › Serviceable
Issued 28 February 2005
Resolved
Replace/repair beckets on port side lifebuoy.
Deck/Cargo › Fishing
Issued 1 March 2004
Resolved
Mount Bait pumps LEGACY COMPONENT DESC: Bait Pumps
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 1 March 2004
Resolved
Repair or renew emergency exit handle for walk in Reefer on main deck
Deck/Cargo › Fishing
Issued 1 March 2004
Resolved
Repair/Renew Bait Pump safety guard and properly mount. LEGACY COMPONENT DESC: Bait Pump
Engineering › Bilge Water Management System
Issued 1 March 2004
Resolved
Mount bilge pump in pump room. LEGACY COMPONENT DESC: Pump
Electrical › Electrical Distribution System (service)
Issued 1 March 2004
Resolved
Remove or properly terminate in junction boxes all dead ended/unused wiring on the vessel. LEGACY COMPONENT DESC: Cable
Electrical › Electrical Distribution System (emergency)
Issued 1 March 2004
Resolved
Install metallic clamps on Nav Light cables to secure them. LEGACY COMPONENT DESC: Cable
Electrical › Electrical Distribution System (service) › Switchboard
Issued 1 March 2004
Resolved
Provide a lock for port power panel in pump room.
Electrical › Electrical Distribution System (service)
Issued 1 March 2004
Resolved
Properly wire pump room fans. LEGACY COMPONENT DESC: Cable
Electrical › Lighting (service)
Issued 1 March 2004
Resolved
Repair/renew light diffuser in welding room. LEGACY COMPONENT DESC: Lighting Fixture
Electrical › Electrical Distribution System (service)
Issued 1 March 2004
Resolved
Provide insulation on inside of SWBD door. LEGACY COMPONENT DESC: Shore Connection Box
Electrical › Electrical Distribution System (service)
Issued 1 March 2004
Resolved
Provide lock on vertical door of distribution panel. LEGACY COMPONENT DESC: Switchboard
Electrical › Electrical Distribution System (service)
Issued 1 March 2004
Resolved
Install handle on main distribution panel port side. LEGACY COMPONENT DESC: Switchboard
Electrical › Electrical Distribution System (service)
Issued 1 March 2004
Resolved
Provide cover for connections to anchor winch directional valve. LEGACY COMPONENT DESC: Outlet Box
Electrical › Electrical Distribution System (service)
Issued 1 March 2004
Resolved
Install covers on receptacles that are missing covers throughout the vessel. LEGACY COMPONENT DESC: Outlet Box
Engineering
Issued 1 March 2004
Resolved
Mount fan over fuel manifold with Metallic mountings.
Electrical › Electrical Distribution System (service)
Issued 1 March 2004
Resolved
Provide proper connections for F/O XFR pump LEGACY COMPONENT DESC: Junction Box
Engineering › Fuel Oil Service System
Issued 1 March 2004
Resolved
Repair leaks in F/O purifier. LEGACY COMPONENT DESC: Filter
Electrical › Lighting (service)
Issued 1 March 2004
Resolved
Connect engine room lights in junction box and change cable to 14 AWG boat cable. LEGACY COMPONENT DESC: Lighting Fixture
Electrical › Electric Generation Source (service)
Issued 1 March 2004
Resolved
Clean generator windings. LEGACY COMPONENT DESC: Generator
Engineering
Issued 1 March 2004
Resolved
Mount fan in hold under berthing.
Engineering
Issued 1 March 2004
Resolved
Hang pipe in hold under berthing with metal hangers.
Construction/Loadline › Hull
Issued 1 March 2004
Resolved
Repair cracks in rubber coating on deck.
Lifesaving › Lifebuoys
Issued 1 March 2004
Resolved
Replace watertight lanyards and lifelines on both sides of vessel.
Communications › Radio Communications
Issued 1 March 2004
Resolved
Provide updated batteries on SARTS.
Engineering › Fuel Oil Storage/Transfer System
Issued 1 March 2004
Resolved
Provide handle for #2 fuel manifold valve. LEGACY COMPONENT DESC: Valve
Lifesaving › Rescue Boat
Issued 1 May 2003
Resolved
Provide rescue boat or proper boarding ladder. LEGACY COMPONENT DESC: Embarkation/Disembarkation Capabilities
Electrical › Electric Supply System (service)
Issued 1 May 2003
Resolved
Hard wire air relief valve and light near aircompressor in E/R. LEGACY COMPONENT DESC: Cable
Fire Fighting › Ventilation Systems
Issued 1 May 2003
Resolved
install 30X30 screen mesh on sewage ventillation duct. LEGACY COMPONENT DESC: Ducts
Engineering › Freshwater System (air cooling)
Issued 1 May 2003
Resolved
Bolt condensor pump to its' mountings. LEGACY COMPONENT DESC: Pump
Lifesaving › Lifejacket/PFD (General)
Issued 1 May 2003
Resolved
Provide physical separation of adult and child PFDs LEGACY COMPONENT DESC: Storage
Engineering › Bilge Water Management System
Issued 5 March 2002
Resolved
Display proper operation of alarm panel in pilot house. LEGACY COMPONENT DESC: Interface Detector
Electrical › Electrical Distribution System (emergency)
Issued 5 March 2002
Resolved
Repack stuffing tubes into box in lazarette. LEGACY COMPONENT DESC: Junction Box
Electrical › Electrical Distribution System (service)
Issued 5 March 2002
Resolved
Install metal cable supports for cable over ladder to the ER and reconnect the wire into a JCT box. LEGACY COMPONENT DESC: Cable
Electrical › Electrical Distribution System (service)
Issued 5 March 2002
Resolved
Install metal cable hangers in STBD aft pump room to support electrical cables. LEGACY COMPONENT DESC: Cable
Engineering › Bilge Water Management System
Issued 5 March 2002
Resolved
Bolt bilge pump to mounting in pump room. LEGACY COMPONENT DESC: Pump
Electrical › Electrical Distribution System (service)
Issued 5 March 2002
Resolved
Cover blanks in pump room power panel. LEGACY COMPONENT DESC: Panelboard
Electrical › Electrical Distribution System (service)
Issued 5 March 2002
Resolved
Cover distribution panel bus bars to make them dead front. LEGACY COMPONENT DESC: Distribution Panel Bus
Electrical › Electrical Distribution System (service)
Issued 5 March 2002
Resolved
Install chafing ring on cable entrance to the ER distribution panel. LEGACY COMPONENT DESC: Cable
Fire Fighting › Structural - B Class Divisions
Issued 5 March 2002
Resolved
Seal sll lower penetrations on the aft portion of the ER LEGACY COMPONENT DESC: Bulkheads - Machinery Spaces
Engineering › Bilge Water Management System
Issued 5 March 2002
Resolved
Bolt down bilge pump in the ER. LEGACY COMPONENT DESC: Pump
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 5 March 2002
Resolved
Install light cover in berth #2. LEGACY COMPONENT DESC: Berth
Electrical › Lighting (emergency)
Issued 5 March 2002
Resolved
demonstrate proper operation of berthing area emergency lighting. LEGACY COMPONENT DESC: Lighting Branch Circuit
Electrical › Electrical Distribution System (service)
Issued 5 March 2002
Resolved
Remove dead end cable in aft bunkroom bilge. LEGACY COMPONENT DESC: Cable
Electrical › Electrical Distribution System (service)
Issued 5 March 2002
Resolved
band cable at entrance to FWD bunkroom bilge. LEGACY COMPONENT DESC: Cable
Electrical › Electrical Distribution System (service)
Issued 5 March 2002
Resolved
Reseal cable tube STBD side FWD bunkroom bilge to prevent leaking. LEGACY COMPONENT DESC: Cable
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 5 March 2002
Resolved
Lubricate reefer door escape handles.
Lifesaving
Issued 5 March 2001
Resolved
Post PFD instruction placard.
Documentation
Issued 5 March 2001
Resolved
Post all pages of COI in galley area.
Lifesaving
Issued 5 March 2001
Resolved
Childrens PFD locker needs to be properly marked.
Lifesaving
Issued 5 March 2001
Resolved
Label upper deck for passenger capacity.
Documentation
Issued 5 March 2001
Resolved
Post stability letter in wheelhouse.
Lifesaving
Issued 5 March 2001
Resolved
escape hatches need placards.
Lifesaving
Issued 5 March 2001
Resolved
Properly lable first aid kit.
Navigation
Issued 5 March 2001
Resolved
Provide required compass light.
Documentation
Issued 5 March 2001
Resolved
Provide copy of tide table on vessel.
Lifesaving
Issued 13 April 2000
Resolved
Provide EPIRB prior to operation with passengers.
Lifesaving
Issued 13 April 2000
Resolved
Properly attach liferafts with approved weak links prior to operation with passengers.
Lifesaving
Issued 13 April 2000
Resolved
Replace life ring port side (line sun damaged) prior to operation with passengers.
Lifesaving
Issued 13 April 2000
Resolved
Replace lanyards attaching water light to ring buoys IAW 46 CFR 180.70 (d) (1)
Lifesaving
Issued 13 April 2000
Resolved
Replace waterlight for ring buoy port side (water inside) prior to_x001C_ operation with passengers.
Documentation
Issued 13 April 2000
Resolved
Provide valid load line certificate prior to 0peration with passengers.
Documentation
Issued 13 April 2000
Resolved
Provide valid FCC safety radio certificate prior to operation with passengers.
Documentation
Issued 13 April 1998
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Documentation
Issued 19 March 1997
Resolved
POST EMERGENCY BROADCAST PLACARD
Engineering
Issued 19 March 1997
Resolved
INSTALL F/O FLAME SCREEN ON #5 STDB F/O TANK VENT
Construction/Loadline
Issued 19 March 1997
Resolved
PLUG OVBD DISCHARGE LINE STBD SIDE IN AFT STATEROOM VOID
Lifesaving
Issued 19 March 1997
Resolved
STENCIL NAME OF VESSEL ON S.A.R.T.
Construction/Loadline
Issued 19 March 1997
Resolved
INSTALL BLIND FLANGES ADJACENT TO VALVES ON SUCTION SIDE OF BAIT TANK PUMPS
Construction/Loadline
Issued 19 March 1997
Resolved
REPAIR THE BILGE ALARM IN THE FORPEAK VOID
Engineering
Issued 19 March 1997
Resolved
REPAIR ENGINE ALARM PANEL. SHOW ALL ALARMS AND LIGHTS WORK CORRECTLY.
Documentation
Issued 19 March 1997
Resolved
POST WASTE PLAN PER 33 CFR 151.59
Documentation
Issued 19 March 1997
Resolved
PROVIDE LOGS FOR CREW TRAINING/DRILLS, LIFESAVING AND EPIRB INSPECTION, PERNEW IFR REQUIREMENTS
Lifesaving
Issued 19 March 1997
Resolved
POST EMERGENCY INSTRUCTIONS AND STATION BILL.
Construction/Loadline
Issued 8 March 1996
Resolved
Repair drain piping for forward head compartment._x001C_
Navigation
Issued 8 March 1996
Resolved
Ensure air compressor tanks are marked properly._x001C_
Engineering
Issued 8 March 1996
Resolved
Renew saltwater cooling hose on starboard and center main engine._x001C_
Construction/Loadline
Issued 8 March 1996
Resolved
Install safety chains on all top side hatches._x001C_
Construction/Loadline
Issued 8 March 1996
Resolved
Install gasket on windlass hatch cover._x001C_
Electrical
Issued 27 March 1992
Resolved
MAKE READY BOTH SSDG'S FOR TEST OF THE OVERSPEED TRIPS TO THE PRIME MOVER.
Engineering
Issued 27 March 1992
Resolved
MAKE READY STARBOARD MAIN ENGINE FOR OPERATIONAL TEST AFTER REPAIRS MADE.
Engineering
Issued 27 March 1992
Resolved
PROVIDE MARKING TO REMOTE FUEL SHUTDOWN ON DECK.
Fire Fighting
Issued 27 March 1992
Resolved
MAKE ALTERATION TO PROPERLY HOUSE B-II EXTINGUISHER MOUNTING BRACKET IN THEFORWARD ACCOMMODATION SPACE.
Accommodation/Occupational Safety
Issued 27 March 1992
Resolved
MARK EMERGENCY LIGHTING IN BELOW DECK ACCOMMODATION SPACES.
Accommodation/Occupational Safety
Issued 27 March 1992
Resolved
PERMANENTLY AFFIX PLACARD MARKING EMERGENCY ESCAPE IN WAY OF FORWARD ACCOMMODATION SPACE.
Accommodation/Occupational Safety
Issued 27 March 1992
Resolved
SECURE OVERBOARD DISCHARGE VALVE TO THE MSD WITH CHAIN AND LOCK.
Construction/Loadline
Issued 27 March 1992
Resolved
MAKE REPAIR TO BILGE ALARMS IN FOREPEAK SPACE AND PUMP ROOM.
Fire Fighting
Issued 20 April 1990
Resolved
PROVIDE A PRESSURE GAUGE ON THE FIRE PUMP DISCHARGE SIDE.
Lifesaving
Issued 20 April 1990
Resolved
PROPERLY CONDUCT ANNUAL SERVICING ON THE TWO LIFE RAFTS CARRIED ON BOARD.
Electrical
Issued 20 April 1990
Resolved
PROVIDE AN EMERGENCY LIGHT TO THE VICINITY OF THE ESCAPE LADDER IN WAY OF THE FORWARD BUNK ROOM.
Unknown
Issued 20 April 1990
Resolved
REMOVE OXY/ACETYLENE WELDING OUTFIT OFF THE VESSEL.
Construction/Loadline
Issued 20 April 1990
Resolved
PROVIDE PROPER SECURING DEVICE TO THE WATERTIGHT HATCH ON THE MAIN DECK LEADING TO THE ENGINE ROOM.
Construction/Loadline
Issued 20 April 1990
Resolved
REMOVE THE WATERTIGHT DOOR AT FRAME 26 AND COMPLETLY MAKE THE BULKHEAD WATERTIGHT WITHOUT ANY ACCESS OPENING USING THE SAME MATERIAL AND EQUIVALENT STRENGTH AS THE BULKHEAD. PRIOR TO ANY WELDING AND INSTALLATION THE FIT-UP SHALL BE CHECKED BY THE ATTENDING CG INSPECTOR FOR APPROVAL.
Casualty record · 4
28 May 2006Routine · role: Involved in a Marine Casualty · activity 2666251
24 October 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 3877024
15 June 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4053826
3 September 2023Routine · role: Involved in a Marine Casualty · activity 7814718
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.