04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 12 August 2026
Resolved
a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: A machinery space bilge... Bilge high level alarm in Engine Room compartment was not secured to the deck.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 August 2026
Resolved 12 August 2026
Resolution: High level alarm attached properly.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 12 August 2026
Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 pounds per square inch at the pump outlet. The pump outlet shall be fitted with a pressure gage. Fire pump did not have a gauge at the outlet.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2026
Resolved 13 August 2026
Resolution: Fire pump gauge installed.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 1 May 2025
Resolved
The following vessels must have on board a properly installed, operational Coast Guard type-approved AIS Class A device…A self-propelled vessel of 65 feet or more in length, engaged in commercial service. Vessel does not have AIS.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2025
Resolved 12 June 2025
Resolution: Installed AIS.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 1 May 2025
Resolved
Portable watertight containers for distress flares and smoke signals shall be of a bright color, and containers shall be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high: “DISTRESS SIGNALS”. Distress signals storage container is not properly labeled.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2025
Resolved 12 June 2025
Resolution: Properly labled container.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 1 May 2025
Resolved
Fuel filters fitted with bowls of other than steel construction must be approved by the Commandant and be protected from mechanical damage. Approval of bowls of other than steel construction will specify if a flame shield is required. Fuel filter on the generator was missing the flame protection bowl under the fuel filter glass.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2025
Resolved 12 June 2025
Resolution: Replaced fuel filter with metal spin on filter.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 May 2025
Resolved
All vessels shall be provided with bilge pumps in accordance with Table 182.25-10(a). L vessel (any number of passengers) over 65 feet 2 fixed power pumps, 50 gallons per minute. Vessel needs secondary pump.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2025
Resolved 12 June 2025
Resolution: Repaired bilge PTO and tested operation.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 1 May 2025
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2025
Resolved 12 June 2025
Resolution: Labeled valves with direction of operation.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 1 May 2025
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Emergency procedures need to be the most updated company version and posted in proper locations on vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2025
Resolved 12 June 2025
Resolution: Emergency procedures updated.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 May 2025
Resolved
Waste receptacles. Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Plastic trash cans need to be replaced with metal.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2025
Resolved 12 June 2025
Resolution: Plastic trash can replaced with metal.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 1 May 2025
Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16). Top side life buoy with light had wasted reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2025
Resolved 12 June 2025
Resolution: Wasted reflective tape replaced.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 1 May 2025
Resolved
The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard required by § 185.510 of this part. Corrected on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 May 2025
Resolved 1 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 1 May 2025
Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16) (incorporated by reference; see 46 CFR 175.600). Corrected on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 May 2025
Resolved 1 May 2025
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 May 2025
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: (1) Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. The bracket localed at the operating station needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2025
Resolved 12 June 2025
Resolution: Bracket replaced with new.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 1 May 2025
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. Labeling missing on the starboard side of the upper deck.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2025
Resolved 12 June 2025
Resolution: Installed label for max persons on second deck.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 1 May 2025
Resolved
The pump outlet shall be fitted with a pressure gauge. The gauge at the fire pump was not operational.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2025
Resolved 12 June 2025
Resolution: Gauge installed on fire pump.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 1 May 2025
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 3 feet in length, but not more than 6 feet, securing the waterlight around the body of the ring life buoy. Corrected on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 May 2025
Resolved 1 May 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 May 2024
Resolved
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in 176.500(b)(1) [annual inspection within 3 months before or after each anniversary date] and your Certificate of Inspection must be endorsed. Vessel is outside of three months window for Inspection and is not permitted to operate until annual inspection has been completed.
46 CFR 176.502
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2024
Resolution: Renewal COI completed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 2 October 2023
Resolved
A hatch exposed to the weather must be watertight.
The aft weather deck hatch leading to steering gear needs to be watertight. Add proper gasket material and ensure hatch can be sealed when secured.
46 CFR 179.360(a)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 October 2023
Resolved 17 May 2024
Resolution: sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 April 2023
Resolved
Exhaust piping shall be led to the point of escape with a minimum number or bends or elbows. It shall be gas tight throughout its length. MI identified exhaust leak in port side muffler. Replace with new.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2023
Resolved 28 April 2023
Resolution: Operator sent video evidence of new muffler satisfactoruly installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 May 2022
Resolved
Fuel leak on stbd and port engine. Clean and test to find fuel leak location.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 May 2022
Resolved 6 May 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 May 2022
Resolved
Oil leaks on port and stbd engines, clean excessive oil and test engines for oil leaks. Provide repair plan to the Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 May 2022
Resolved 6 May 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 May 2022
Resolved
Stbd exhuast is showing signs of water sipping through the muffler fiberglass. Space was filled with exhaust fumes while testing. Replace with new.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 May 2022
Resolved 6 May 2022
Resolution: New Exhaust was installed
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 May 2022
Resolved
There are excess of cables with loose ends under the console. Remove all cable excess from under console.
Action required: 705 - Other - as specified
Due 4 June 2022
Resolved 14 May 2024
Resolution: All sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 May 2022
Resolved
Remove all temporary extension cords and make permanent connections.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2022
Resolved 17 May 2024
Resolution: sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 May 2022
Resolved
Replace all missing and broken bilge strainers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2022
Resolved 18 May 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 May 2022
Resolved
Battery terminals were full of corrosion. Clean terminals and protect from future build up.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2022
Resolved 18 May 2022
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 4 May 2022
Resolved
Remove all corrosion from bilges and spaces. Clean and preserve all spaces.
Action required: 705 - Other - as specified
Due 4 June 2022
Resolved 17 May 2024
Resolution: Sat.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 26 March 2022
Resolved
Any vessel of at least 5 net tons engaging in coastwise trade must have a valid Certificate of Documentation. The vessel's Certificate of Documentation has expired. Renew Certificate of Documentation prior to the carriage of passengers.
46CFR176.502
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2022
Resolution: Operator sent proof of certified copy of COD.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 19 April 2021
Resolved
Found extensive deck plate corrosion on 2nd deck around concession stand. Provide repair proposal.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2021
Resolution: Vessel approved to install 1/4" aluminum doubler plate over existing deck around concessioon stand on 2nd deck. Permanent repairs to be made at next dry dock in Sept 2021.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 April 2021
Resolved
Emergency fuel shut off valve broke at the valve handle on fuel tank side. Make proper repairs to emergency fuel shut off valve.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2021
Resolution: Installed new shutoff valve.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 19 April 2021
Resolved
Provide a valid Certificate of Documentation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2021
Resolution: Provided proof of valid COD.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 April 2021
Resolved
Observed electrical wiring in engine room with missing metal support brackets. Properly install metal support brackets for electrical wiring.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 April 2021
Resolution: Installed new metal support brackets for electrical wiring.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 April 2021
Resolved
Bolts missing from main deck plate located in galley. Install bolts to ensure deck plate is secured to the deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 April 2021
Resolution: Replaced missing bolts.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 27 January 2020
Resolved
Two penetrations on watertight bulkhead connecting engine room to compartment 3 are not watertight. On port side and starboard side of the bulkhead corrosion has created additional non-watertight penetrations. Provide a repair proposal to make penetrations watertight or sealed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2020
Resolved 19 April 2021
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 27 January 2020
Resolved
Fire main piping has a non-satisfactory temporary repair. Replace piping to be in accordance with good marine practice.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2020
Resolved 12 February 2020
Resolution: All piping surronging temp repaire was properly replaced with new pipe.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 27 January 2020
Resolved
Lights list and tide tables are not up to date. Provide up to date lights lists and tide tables.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 February 2020
Resolution: Publications updated and placed onboard.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 27 January 2020
Resolved
Crew could not follow man overboard instructions of using the lifeline when recovering the man overboard. Life line is on the instructions but is not onboard.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 February 2020
Resolution: Life sling was placed on board.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 January 2020
Resolved
Dead end wiring was found in lazarette and engine compartment. Secure dead end wiring.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 February 2020
Resolution: Wiring was reconnected to the fuel sender and removed
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 2 October 2019
Resolved
Seal bulkhead penetration around A/C piping between compartments 3 and 4.
Action required: 705 - Other - as specified
Resolved 7 November 2019
Resolution: All bulkhead penetrations have been properly sealed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 2 October 2019
Resolved
Crop and renew framing around pottable water tank in compartment 4.
Action required: 705 - Other - as specified
Resolved 7 November 2019
Resolution: all identified frames have been cropped an renewed as required.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 April 2019
Resolved
A vessel of more than 65 ft must carry a minimum of three life buoys of not less than 24 inches in diameter. Provide 2 properly marked and installed life buoys. Ring life buoy to be approved IAW 160.050, and marked IAW 185.604 - 46CFR180.70(a)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2019
Resolved 30 April 2019
Resolution: Vessel replaced 2 life buoys
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 April 2019
Resolved
At all inspections special attention shall be paid to insure that no fire hazards exist. The port main engine, ship service generator, and fire insulation i the overhead were found coated with engine oil. Vessel is to maintain regular rounds of the equipment while in operation to monitor for oil buildup on operating machinery. On 29 April 2019, the vessel is not authorized any passenger operations until all oil leaks are identified and corrected. 46CFR176.25-10(b)
Action required: 705 - Other - as specified
Resolved 30 April 2019
Resolution: Seals on generator and engine were replaced.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 27 September 2017
Resolved
Crop and renew wasted plate on port side aft 2 ft fwd and aft of bit above half round.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 6 October 2017
Resolution: Cropped and Renewed wasted plate on port side aft 2 ft fwd and aft of bit half round.