01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 December 2019
Resolved
All pages of the COI must be posted under glass or suitable transparent material. Missing 1st page of the COI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2020
Resolved 24 December 2019
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 December 2019
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. STBD running light has cracked lens and port running light is installed backward.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2020
Resolved 24 December 2019
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 18 December 2019
Resolved
Vessel must have up-to-date charts and publications. VSL is missing coastal pilot. Provide up-to-date coastal pilot.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2020
Resolved 24 December 2019
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 18 December 2019
Resolved
VSL shall have emergency broadcast placard posted next to rediotelephone installation. VSL is missing placard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2020
Resolved 24 December 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 December 2019
Resolved
Life jacket donning placard shall be posted conspicuously on board. Post life jacket donning placards.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2020
Resolved 24 December 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 December 2019
Resolved
Ring life buoy shall be in satisfactory conditions. VSL ring life buoy has damaged outer layer. Replace ring life buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2020
Resolved 24 December 2019
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 18 December 2019
Resolved
Container for flares shall be watertight, bright in color and marked 'DISTRESS SIGNAL". Provide missing flares container.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2020
Resolved 24 December 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 December 2019
Resolved
Portable fire extinguishers must be serviced annually with up-to-date service tag. Provide proof of annual service performed on portable fire extinguishers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2020
Resolved 24 December 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 December 2019
Resolved
VSL must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2020
Resolved 24 December 2019
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 18 December 2019
Resolved
VSL must have a visual and audible alarm at the operating station to indicate a high water level. Repair inoperable alarms and show proper operations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2020
Resolved 24 December 2019
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 December 2019
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. Replace all identified expired items.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2020
Resolved 24 December 2019
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 March 2019
Resolved
Navigation lights must be in working conditions. Repair inoperable starboard running light.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 March 2019
Resolved
Adult and child life jackets must be separated and marked. Mark life jackets location for adult and child.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2019
Resolved 10 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 29 March 2019
Resolved
Distress flares container must be watertight, bright in color and marked with "DISTRESS SIGNALS". Provide proper container with proper mark.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2019
Resolved 10 April 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 March 2019
Resolved
Portable fire extinguishers must be Coast Guard Approved and service annually. Provide proof of service conducted on CO2. Attached service tag.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2019
Resolved 10 April 2019
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 29 March 2019
Resolved
Bilge high level alarm must be operational conditions. Repair inoperable bilge high level alarm for AFT starboard void.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2019
Resolved 10 April 2019
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 29 March 2019
Resolved
Light fixture in passenger area must be in operational condition. Repair inoperable main deck lights.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2019
Resolved 10 April 2019
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 March 2019
Resolved
Replace expire items in first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2019
Resolved 10 April 2019
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 12 December 2017
Resolved
Emergency broadcast placard must be post next to radio as required by 46 CFR 184.506. Post missing emergency broadcast placard.
Due 20 December 2017
Resolved 15 December 2017
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 12 December 2017
Resolved
Propulsion engines must have oil pressure gauge visual at the operator station as required by 46 CFR 182.410. Repair inoperable oil pressure and engine temperature indicators.
Due 20 December 2017
Resolved 15 December 2017
Engineering › Steering Gear System › Linkage
Issued 12 December 2017
Resolved
Steering gear and accessories must be design to fit for route and services intended as required by 46 CFR 176.814. Replace rusted/wasted fittings on steering linkage.
Due 20 December 2017
Resolved 15 December 2017
Electrical › Electric Generation Source (service) › Panelboard
Issued 12 December 2017
Resolved
Breaker must labeled for equipment it serves as required by 46 CFR 183.220. Properly label breaker for navigation lights.
Due 20 December 2017
Resolved 15 December 2017
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 4 December 2016
Resolved
Rail or equivalent protection must be installed near the periphery of all decks accessible to passenger & crew as required by 46 CFR 177.900. Install missing deck rails.
Due 30 May 2017
Resolved 24 May 2017
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 4 December 2016
Resolved
Fuel tank must be adequately support and braced to prevent movement as required by 46 CFR 182.440(b). Install fuel tank support & brace.
Due 30 May 2017
Resolved 24 May 2017
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 4 December 2016
Resolved
Toilet must be serviceable and sanitary conditions as required by 46 CFR 176.818. Remove all store material in toilet space.
Due 30 May 2017
Resolved 24 May 2017
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 4 December 2016
Resolved
Life line on ring life buoy must be non-kinking, 60 feet long,& dark in color as required by 46 CFR 180.70. Replace white/blue life line.
Due 30 May 2017
Resolved 24 May 2017
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 4 December 2016
Resolved
Life buoy must have float light attached to 3 foot lanyard with corrosive resistant clip as required by 46 CFR 180.70. Install float light, lanyard with clip.
Due 30 May 2017
Resolved 24 May 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 December 2016
Resolved
Remove dead end wires under control station.
Due 30 May 2017
Resolved 24 May 2017
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 4 December 2016
Resolved
Individual power pumps must controlled from central control point with light indicating operation as required by 46+ CFR 182.520. Install missing bilge pump control and light indication.
Due 30 May 2017
Resolved 24 May 2017