MAURY USCG vessel records Sign in
← All vessels

SEA EXPERIENCE II

SEA EXPERIENCE II is a 1989 passenger vessel (inspected). The Coast Guard has recorded 68 inspections since 1989, most recently in October 2025, along with 89 deficiencies and 5 casualty investigations between 2006 and 2017.

Records from 1989 to 2025. Most recent: inspection, 27 October 2025.

Built
1989
Last inspected
27 October 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE5411
330039
Flag
UNITED STATES
367366330
Maury page id
psix-330039

Inspections, by type

…with no type recorded10
Years with a record 34 calendar years (1989–2025)
The 68 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)45.0 ft × 14.0 ft × 4.3 ft
Registered tonnagegross 12 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCORINTHIAN YACHTS INC · TARPON SPRINGS, FL, UNITED STATES · built 1989
Hull materialFRP (Fiberglass)
PropulsionGasoline Engine
Hull shapeShip
Hull configurationTwin Hull
Hailing portFORT LAUDERDALE, FL
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 28 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it12 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE5411MMSI 367366330 · active · compulsorily equipped · granted 25 April 2018, expires 2 July 2028
WDB9724MMSI 366981570 · expired · compulsorily equipped · granted 5 October 2004, cancelled 6 December 2014 · licensed under a name not among this hull’s recorded names (not shown)
WCX6521MMSI not assigned · expired · compulsorily equipped · granted 4 August 1997, cancelled 6 October 2007 · licensed under a name not among this hull’s recorded names (not shown)
WCP5482MMSI not assigned · expired · compulsorily equipped · granted 3 January 1995, cancelled 5 March 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 68

27 October 2025 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8259581
29 October 2024 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8026663
16 September 2024 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8007595
25 October 2023 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7814588
13 July 2023 Administrative Inspection · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7738299
19 September 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7561743
27 October 2021 Internal Structural Exam · Drydock Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7340498
25 August 2021 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7296321
1 July 2020 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6991153
29 October 2019 Examination of Repairs · Internal Structural Exam · Administrative Inspection · Annual Inspection · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6844265
1 July 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6731769
18 July 2018 DAPI Audit · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6476418
31 October 2017 Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6298075
25 August 2017 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6251081
7 May 2017 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 6140823
7 May 2017 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6148398
1 June 2016 Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5892296
5 November 2015 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5758381
8 September 2015 DAPI Audit
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5743040
13 July 2015 Administrative Inspection · Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5182742
12 June 2014 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4892053
9 June 2014 Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4883828
18 July 2012 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 4388193
7 February 2012 Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4239476
20 September 2011 DAPI Audit · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4149644
20 September 2010 Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3851578
22 May 2008 Initial Certification · COI Inspection · Hull Examination · Plan Review "T" Boat · Deadweight Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3213351
14 August 2006 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2865558
25 July 2006 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2724298
24 August 2005 Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2472479
20 December 2004 Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2272206
13 July 2004 Administrative Inspection · Re-Inspection · Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 2132534
25 June 2003 MARPOL Annex V Examination · Administrative Inspection · Re-Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1820566
21 January 2003 Administrative Inspection · Hull Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1730973
1 October 2002 Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1683960
19 September 2002 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1676277
1 June 2001 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1393693
16 May 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1066626
1 March 2001 MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1389313
26 January 2001 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1458835
18 May 2000 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 817997
25 March 1999 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1114590
18 February 1999 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1384041
17 February 1999 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1384040
1 July 1998 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 793487
24 February 1998 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 778800
24 June 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1448931
25 February 1997 Hull Examination · Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1106730
15 February 1996 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 879436
23 January 1996 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 872521
29 November 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 883335
24 May 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 874577
8 March 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1169553
16 February 1995 COI Inspection · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1153166
25 April 1994 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1457166
18 April 1994 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1412625
27 July 1993 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 844117
21 April 1993 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1432679
24 April 1992 COI Inspection · Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1357934
28 May 1991 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 934229
21 May 1991 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 919493
7 January 1991 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1259005
20 November 1990 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 901230
1 May 1990 Deficiency Check · Re-Inspection · Drydock Extension
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 905831
20 June 1989 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1346841
24 May 1989 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1035735
10 May 1989 Hull Examination · Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 897855
10 May 1989 Initial Certification · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 898619

Deficiency record · 89

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 27 October 2025 Resolved
Neither engine displayed Oil pressure or Engine temperature. Restore function to gauges.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 November 2025
Resolved 5 November 2025
Resolution: Vessel replaced gauges at operating station.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 October 2025 Resolved
Remote fuel shutoff stations shall be marked in at least 1-inch letters indicating purpose of the valve and direction of operation. Remote shutoff valve was not labeled.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 November 2025
Resolved 5 November 2025
Resolution: Fuel valves labeled properly.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 27 October 2025 Resolved
Broken stanchion on stbd side midship not secured to deck. Secure stanchion to deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 November 2025
Resolved 5 November 2025
Resolution: Stanchion secured.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 27 October 2025 Resolved
Emergency instruction and life jacket donning instructions not posted. Post emergency instructions and lifejacket donning instructions
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 November 2025
Resolved 5 November 2025
Resolution: Donning placard replaced.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 27 October 2025 Resolved
Drill and training log not present onboard
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 November 2025
Resolved 5 November 2025
Resolution: Log books provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 August 2021 Resolved
REPLACE SOLAS APPROVED RETRO-REFLECTIVE TAPE ON 02 IDENTIFIED LIFEJACKETS AND 02 CHILD LIFEJACKETS.
Action required: 10 - Deficiency Rectified
Due 25 August 2021
Resolved 25 August 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 August 2021 Resolved
REMOVE DEAD END WIRING FROM FORWARD COMPARTMENT, PORT SIDE HULL.
Action required: 10 - Deficiency Rectified
Due 25 August 2021
Resolved 25 August 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 August 2021 Resolved
REPLACE/REPAIR BILGE PUMP IN FORWARD COMPARTMENT, PORT SIDE HULL.
Action required: 10 - Deficiency Rectified
Due 25 August 2021
Resolved 25 August 2021
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 25 August 2017 Resolved
Replace 01 Type 1 lifejacket.
Action required: 705 - Other - as specified
Due 19 September 2017
Resolved 27 September 2017
Resolution: Vessel provided pictures and receipts of PFD replacement.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 25 August 2017 Resolved
Properly cap off dead-end wires fwd port and stbd side; aft battery ground requires proper ground connection.
Action required: 705 - Other - as specified
Due 19 September 2017
Resolved 27 September 2017
Resolution: Vessel provided proof of dead end wire removal and proper terminal connections.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 August 2017 Resolved
46 CFR 160.041: Replace aspirin and burn cream.
Action required: 705 - Other - as specified
Due 5 September 2017
Resolved 5 September 2017
Resolution: Purchased aspirin and burn cream to replenish supplies on hand.
Construction/Loadline › Structures › Deck Plating
Issued 5 November 2015 Resolved
Deck core is rotted at all access points.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 November 2015
Resolved 19 November 2015
Resolution: Repair complete.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 5 November 2015 Resolved
Repair stbd railing station where holed/wasted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 November 2015
Resolved 19 November 2015
Resolution: Repair complete.
Construction/Loadline › Hull › Strut/Cross Tie
Issued 5 November 2015 Resolved
Repair cracks at transom and bow inboard of both hulls.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 November 2015
Resolved 19 November 2015
Resolution: Repair complete.
Construction/Loadline › Hull › Bottom Plating
Issued 5 November 2015 Resolved
Renew defective glass bottom hardware.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 November 2015
Resolved 19 November 2015
Resolution: Repair complete.
Stability › Unintentional Flooding › General
Issued 5 November 2015 Resolved
Seal obsolete overboard discharge glass bottom, outboard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 November 2015
Resolved 19 November 2015
Resolution: Cap placed over discharge.
Construction/Loadline › Structures › Deck Plating
Issued 5 November 2015 Resolved
Renew decking fwd port where holed/wasted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 November 2015
Resolved 10 November 2015
Resolution: Operator renewed fwd area of decking.
Construction/Loadline › Hull › Stiffener
Issued 5 November 2015 Resolved
Relaminate stiffener connecting points in port center compartment.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 November 2015
Resolved 19 November 2015
Resolution: Repair complete.
Construction/Loadline › Hull › Transverse Frame
Issued 5 November 2015 Resolved
Repair cracked/ rotted upper transom frame port and stbd.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 27 November 2015
Resolved 19 November 2015
Resolution: Repair complete.
Electrical › Electrical Distribution System (service) › Cable
Issued 13 July 2015 Resolved
Cables shall be supported by metal supports spaced not more than 24" apart. Wire run to the light in the head, port hull and wire run to high water alarm are unsupported.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2015
Resolved 9 September 2015
Resolution: Verified wire properly supported.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 13 July 2015 Resolved
COI requires 03 portable fire extinguishers. 01 extinguisher has leaked propllent through neck and 01 is severely corroded at base leaving a remainder of 01 portable extinguisher on board. Operator to provide satisfactory portable fire extinguisher prior to ops.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2015
Resolution: Fire service provider delivered two replacement portable fire extinguishers to the satisfaction of the Marine Inspector.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 13 July 2015 Resolved
As appropriate for the intended voyage, the vessel must carry up to date charts. Chart on board is an uncorrected 2013 edition. Operator must renew/correct.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 July 2015
Resolved 9 September 2015
Resolution: Verified updated chart on board.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 13 July 2015 Resolved
Vessel must carry up to date publications. Operator must provide August 2014 edition of Navigation Rules and Regulations Handbook.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 July 2015
Resolved 21 July 2015
Resolution: Verified updated Navrules book onboard.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 13 July 2015 Resolved
Float light battery is required to be renewed annually by Mfr inst. Vessel has no record of renewal and has no memory of last renewal date. Operator required to renew and document.
Action required: 705 - Other - as specified
Due 20 July 2015
Resolved 21 July 2015
Resolution: Verified battery renewed.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 13 July 2015 Resolved
Vessel is required by COI to carry 51 type I PFDs. 03 are determined to be unserviceable and are required to be destroyed. Additionally 6 require new retro-reflective tape.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 July 2015
Resolved 13 July 2015
Resolution: Operator provided new lifejackets and applied retro reflective tape.
Construction/Loadline › Structures › Deck Plating
Issued 13 July 2015 Resolved
Provide proposal to renew/repair decking at soft spot, centerline forward as original to include use of fire retardant resin. Permanent repair to be completed at next regularly scheduled dry dock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 August 2015
Resolved 18 August 2015
Resolution: Received repair proposal for upcoming dry dock period.
Construction/Loadline › Structures › Deck Plating
Issued 13 July 2015 Resolved
Provide repair proposal to seal fwd stbd compartment access IWO deck and repair as original rotten wood core material IWO unfinished cut-out for fwd stbd hull. Permanent repair to be completed at next regularly scheduled dry dock repair period.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 August 2015
Resolved 18 August 2015
Resolution: Received repair proposal to be completed at up coming dry dock period.
Construction/Loadline › Structures › Deck Plating
Issued 13 July 2015 Resolved
Provide repair proposal to repair rotted decking and transverse deck beam IWO stanchion stbd side aft of glass bottom access. Permanent repair to be completed at next regularly scheduled dry dock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 August 2015
Resolved 18 August 2015
Resolution: Received repair proposal to be completed at upcoming dry dock period.
Construction/Loadline › Structures › Deck Plating
Issued 13 July 2015 Resolved
Provide repair proposal for permanent repair of broken fiberglass decking inboard of glass bottom access.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 August 2015
Resolved 18 August 2015
Resolution: Received repair proposal to be compled at upcoming drydock period.
Stability › Incline Test › General
Issued 13 July 2015 Resolved
Operator required by stability letter to notify local OCMI when changes occur which affect the weights. Operator to provide documentation attesting to the weight change in process of repower.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 July 2015
Resolved 21 July 2015
Resolution: Verified weight of engines remain the same by manufacturers specs (608 lbs).
Fire Fighting › Remote Fuel Shutoff › General
Issued 9 June 2014 Resolved
Label fuel shutoffs indicating purpose and direction of operation. 46CFR185.610
Action required: 705 - Other - as specified
Due 16 June 2014
Resolved 12 June 2014
Fire Fighting › Fire Bucket › Stenciling
Issued 9 June 2014 Resolved
Label fire buckets. 46CFR181.610
Action required: 705 - Other - as specified
Due 16 June 2014
Resolved 12 June 2014
Communications › Alarms/Indicators › Bilge Alarm
Issued 9 June 2014 Resolved
Replace visual and audible bilge high water level alarm (port side) 46CFR182.530 (alarm worked but light did not)
Action required: 705 - Other - as specified
Due 16 June 2014
Resolved 12 June 2014
Construction/Loadline › Hull › Hull Plating
Issued 7 February 2012 Resolved
Complete repairs to portside bow FRP IAW submitted plan proposal dated 07FEB2012. Repair laminate and lay the first layer over the entire area, including overlap, then build-up the required thickness. The subsequent layers should be some what wider than necessary, then ground smooth after cured for the final layer used to seal the exposed edges.
Due 7 February 2012
Resolved 8 February 2012
Construction/Loadline › Structures › Transverse Bulkhead
Issued 20 September 2011 Resolved
Crop to good wood and renew as original #1 transverse underdeck beam in the #1 compartment. Also, crop to good wood and renew main deck overhead wasted/rotten beam.
Action required: 705 - Other - as specified
Due 30 April 2012
Resolved 8 February 2012
Construction/Loadline › Structures › Deck Plating
Issued 20 September 2011 Resolved
Make proper repairs to fiberglass stbd bow IWO hatch and at bow corner.
Action required: 705 - Other - as specified
Due 30 April 2012
Resolved 8 February 2012
Lifesaving › Hand Flares › Quantity
Issued 20 September 2011 Resolved
Provide required flares for limited coastwise routes.
Action required: 705 - Other - as specified
Due 21 September 2011
Resolved 20 September 2011
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 20 September 2011 Resolved
Provide required amount of life jackets as per COI.
Action required: 705 - Other - as specified
Due 21 September 2011
Resolved 20 September 2011
Electrical › Electrical Distribution System (service) › Cable
Issued 20 September 2011 Resolved
Properly secure electrical cable in port aft bilge.
Action required: 705 - Other - as specified
Due 25 September 2011
Resolved 22 September 2011
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 September 2011 Resolved
Replace port navigation light lens cover.
Action required: 705 - Other - as specified
Due 25 September 2011
Resolved 22 September 2011
Resolution: Lens cover replaced.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 20 September 2010 Resolved
Replace expired EPIRB hydro-static release.
Due 25 September 2010
Resolved 23 September 2010
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 20 September 2010 Resolved
Provide copy of current tables for operating area.
Due 25 September 2010
Resolved 23 September 2010
Construction/Loadline › Hull › Hull Plating
Issued 28 May 2008 Resolved
Cut back wasted area on Bow section and make available for inspection. Submit proposal for repairs.
Action required: 705 - Other - as specified
Resolved 5 June 2008
Resolution: Properly completed repairs to bow.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 22 May 2008 Resolved
Provide plans for vessel as required by 46 CFR 177.202
Action required: 705 - Other - as specified
Resolved 29 July 2008
Construction/Loadline › Hull › Side Shell
Issued 22 May 2008 Resolved
Grind out cracks on Port & Starboard bow and stern area and make available for for inspection.
Action required: 705 - Other - as specified
Resolved 5 June 2008
Resolution: Proper repairs completed.
Construction/Loadline › Structures › Deck Plating
Issued 22 May 2008 Resolved
Grind out cracks on deck in mid-ship and bow area and make available for inspection.
Action required: 705 - Other - as specified
Resolved 5 June 2008
Resolution: Proper repairs completed.
Construction/Loadline › Structures › Deck Plating
Issued 22 May 2008 Resolved
Submit plans for replacement of main deck aft with lay-up schedule.
Action required: 705 - Other - as specified
Resolved 5 June 2008
Resolution: Properly completed replacement of aft main deck.
Construction/Loadline › Hull › Bottom Plating
Issued 22 May 2008 Resolved
Submit repair proposal for cracked inboard side of port stern.
Action required: 705 - Other - as specified
Resolved 5 June 2008
Resolution: Proper repairs completed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 May 2008 Resolved
Replace expired items in first aid kit.
Action required: 705 - Other - as specified
Resolved 6 August 2008
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 22 May 2008 Resolved
Provide proof of EAP training.
Action required: 705 - Other - as specified
Resolved 6 August 2008
Lifesaving › Buoyant Apparatus › Marking
Issued 13 July 2004 Resolved
Properly mark vessel's name & capacity on both Life floats.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2004
Resolved 19 July 2004
Resolution: Cleared. Received fax from owner indicating item has been corrected.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 13 July 2004 Resolved
Install additional retro-reflective tape on 5 adult PFD's.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2004
Resolved 19 July 2004
Resolution: Cleared. Received fax from owner indicating item has been corrected.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 13 July 2004 Resolved
Renew mounting bracket for B-I fire extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2004
Resolved 19 July 2004
Resolution: Cleared. Received fax from owner indicating item has been corrected.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 13 July 2004 Resolved
Re-stencil vessel's name on ringbuoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2004
Resolved 19 July 2004
Resolution: Cleared. Received fax from owner indicating item has been corrected.
Communications › Radio Communications › EPIRB
Issued 25 June 2003 Resolved
Replace Category II EPIRB with automatically activated Category I EPIRB.
Action required: 705 - Other - as specified
Due 2 July 2003
Resolved 1 July 2003
Resolution: Corrected. Received fax copy of EPIRB Registration form indicating Category I EPIRB has been purchased.
Documentation › Certificates/Documents › Stability Letter
Issued 25 June 2003 Resolved
Provide & post Stability Letter.
Action required: 705 - Other - as specified
Due 2 July 2003
Resolved 13 July 2004
Resolution: Stability Letter issued by CORMS 28May92 cannot be located. New Stability Letter will be issued by MIAMS based on Sister vessel to LONG KEY PRINCESS, 941791.
Documentation › Certificates/Documents › FCC SSL
Issued 25 June 2003 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 2 July 2003
Resolved 13 July 2004
Resolution: Corrected.
Communications › Radio Communications › VHF Radiotelephone
Issued 25 June 2003 Resolved
Post Emergency Radio Broadcast Placard.
Due 2 July 2003
Resolved 13 July 2004
Resolution: Corrected.
Lifesaving › Hand Flares
Issued 19 September 2002 Resolved
Provide 3 additional red & 2 additional orange hand held flares. LEGACY COMPONENT DESC: Quantity
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 September 2002
Resolved 1 October 2002
Resolution: Corrected.
Lifesaving › Lifebuoys
Issued 19 September 2002 Resolved
Install retroreflective tape on ring buoy. LEGACY COMPONENT DESC: Markings (ship name/port)
Action required: 705 - Other - as specified
Due 26 September 2002
Resolved 1 October 2002
Resolution: Corrected.
Lifesaving › Lifebuoys
Issued 19 September 2002 Resolved
Install floating U/V ray resistant lines on all 3 waterlights. LEGACY COMPONENT DESC: Buoyant Lifeline
Action required: 705 - Other - as specified
Due 26 September 2002
Resolved 1 October 2002
Resolution: Corrected.
Documentation
Issued 18 February 1999 Resolved
Provide a vessel log book with all required entries._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 February 1999
Resolved 18 February 1999
Lifesaving
Issued 18 February 1999 Resolved
Provide proof of registration of the EPIRB with NOAA._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 February 1999
Resolved 18 February 1999
Navigation
Issued 18 February 1999 Resolved
Repair anchor light._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 February 1999
Resolved 18 February 1999
Documentation
Issued 18 February 1999 Resolved
Provide a copy of the latest MIS report filed with CG Headquarters for drugprogram._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 February 1999
Resolved 18 February 1999
Electrical
Issued 24 February 1998 Resolved
Provide 2 flashlights._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 February 1998
Resolved 24 February 1998
Lifesaving
Issued 24 February 1998 Resolved
Properly attach painter on B/As with a weak link._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 February 1998
Resolved 24 February 1998
Fire Fighting
Issued 24 February 1998 Resolved
Service all portable fire extinguishers._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 February 1998
Resolved 24 February 1998
Documentation
Issued 24 February 1998 Resolved
Provide a current FCC Operators Permit._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 February 1998
Resolved 24 February 1998
Lifesaving
Issued 23 January 1996 Resolved
Replace 3 deteriorated waterlight brackets on lights attached to buoyant apparatus. Vessel is restricted to daylight operation only until this is accomplished.
Condition: Unknown
Due 23 January 1996
Resolved 23 January 1996
Lifesaving
Issued 23 January 1996 Resolved
Capacity of vessel is reduced to 36 adults and 11 Children until 12 additional approved adult lifejackets are placed on board._x001C_
Condition: Unknown
Due 23 January 1996
Resolved 23 January 1996
Lifesaving
Issued 23 January 1996 Resolved
Replace "Guest model 320" (unapproved) waterlight on ring lifebuoy. Vesselis restricted to daylight operation only until this is accomplished.
Condition: Unknown
Due 23 January 1996
Resolved 23 January 1996
Lifesaving
Issued 16 February 1995 Resolved
Replace 60' line on ring lifebuoy.
Condition: Unknown
Due 16 February 1995
Resolved 16 February 1995
Lifesaving
Issued 16 February 1995 Resolved
install lifejacket placard.
Condition: Unknown
Due 16 February 1995
Resolved 16 February 1995
Lifesaving
Issued 16 February 1995 Resolved
Seperate child and adult lifejackets.
Condition: Unknown
Due 16 February 1995
Resolved 16 February 1995
Lifesaving
Issued 21 April 1993 Resolved
Replace two (2) ring life buoys.
Condition: Unknown
Due 21 April 1993
Resolved 21 April 1993
Lifesaving
Issued 21 April 1993 Resolved
Stow child sized life preservers separately and label stowage.
Condition: Unknown
Due 21 April 1993
Resolved 21 April 1993
Electrical
Issued 21 May 1991 Resolved
PERMANTLEY ATTACH BATTERY BOXES TO VESSEL TO PREVENT SHIFTING
Condition: Unknown
Due 21 May 1991
Resolved 21 May 1991
Electrical
Issued 21 May 1991 Resolved
REMOVE EXISTING WIRING TO VHF RADIO AND CELLULAR PHONE AND INSTALL PROPER SIZE WIRING AND ELECTRICAL CONNECTORS
Condition: Unknown
Due 21 May 1991
Resolved 21 May 1991
Lifesaving
Issued 21 May 1991 Resolved
INSTALL RETROREFLECTIVE TAPE TO ONE ADULT LIFE JACKET
Condition: Unknown
Due 21 May 1991
Resolved 21 May 1991
Lifesaving
Issued 21 May 1991 Resolved
ENSURE 18FT OF LINE IS ATTACHED TO EACH WATER LIGHT THAT ATTACHES TO BOUYANT APPARATUS
Condition: Unknown
Due 21 May 1991
Resolved 21 May 1991
Documentation
Issued 24 May 1989 Resolved
PROVIDE VALID FCC STATION LICENSE.
Condition: Unknown
Due 24 May 1989
Resolved 24 May 1989
Documentation
Issued 24 May 1989 Resolved
PROVIDE FCC SAFETY RADIO TELEPHONY CERTIFICATE.
Condition: Unknown
Due 24 May 1989
Resolved 24 May 1989
Documentation
Issued 10 May 1989 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 10 May 1989
Resolved 10 May 1989
Documentation
Issued 10 May 1989 Resolved
OBTAIN VESSEL DOCUMENTATION AND MAINTAIN ORIGINAL ONBOARD VESSEL.
Condition: Unknown
Due 10 May 1989
Resolved 10 May 1989
Documentation
Issued 10 May 1989 Resolved
OBTAIN FCC RADIO SAFETY CERTIFICATE AND MAINTAIN ORIGINAL ONBOARD VESSEL.
Condition: Unknown
Due 10 May 1989
Resolved 10 May 1989
Documentation
Issued 10 May 1989 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 10 May 1989
Resolved 10 May 1989
Documentation
Issued 10 May 1989 Resolved
OBTAIN VESSEL DOCUMENTATION AND MAINTAIN ORIGINAL ONBOARD VESSEL.
Condition: Unknown
Due 10 May 1989
Resolved 10 May 1989
Documentation
Issued 10 May 1989 Resolved
OBTAIN FCC RADIO SAFETY CERTIFICATE AND MAINTAIN ORIGINAL ONBOARD VESSEL.
Condition: Unknown
Due 10 May 1989
Resolved 10 May 1989

Casualty record · 5

14 August 2006Routine · role: Involved in a Marine Casualty · activity 2865558
13 March 2011Routine · role: Involved in a Marine Casualty · 1 injured · activity 3966743
21 May 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4023022
12 June 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4892053
7 May 2017Routine · role: Involved in a Marine Investigation (non-casualty) · serious marine incident, as classified · 1 injured · activity 6148398
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

REEF CAT (2006). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.