MAURY USCG vessel records Sign in
← All vessels

FETCH II

FETCH II is a 1989 passenger vessel (inspected). The Coast Guard has recorded 51 inspections since 1989, most recently in April 2026, along with 82 deficiencies.

Records from 1989 to 2026. Most recent: inspection, 15 April 2026.

Built
1989
Last inspected
15 April 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

330158
Flag
UNITED STATES
—
Maury page id
psix-330158

Inspections, by type

Years with a record 33 calendar years (1989–2026)
The 51 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 51

15 April 2026 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8350345
14 July 2025 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8185778
29 July 2024 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7969398
27 June 2024 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7942389
6 July 2023 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7734895
7 July 2022 DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7490435
23 May 2022 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7457343
25 April 2022 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7437444
3 August 2021 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7272601
6 April 2021 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7164671
9 September 2020 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7054349
15 August 2019 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6769608
18 April 2019 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6652068
17 October 2018 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6562895
16 May 2018 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6395777
19 June 2017 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6180151
21 June 2016 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5907475
12 June 2014 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4886671
11 July 2012 Administrative Inspection · DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4374273
19 July 2011 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4085942
9 November 2010 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3887735
17 November 2008 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3364513
9 September 2008 Annual Inspection · Simplified Stability Test
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3320826
30 January 2008 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3138991
28 September 2006 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2788792
28 September 2005 Deficiency Check · Periodic Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2507367
30 November 2004 Internal Structural Exam · Hull Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2249970
25 October 2004 Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2224798
15 October 2003 MARPOL Annex V Examination · Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1925803
15 November 2002 Internal Structural Exam · Hull Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1705991
6 September 2002 COI Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1673071
28 August 2001 Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1456015
5 April 2001 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1389406
15 September 2000 Deficiency Check · MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1365983
26 August 1999 MARPOL Annex V Examination · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1393222
5 May 1999 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1449169
2 November 1998 MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 799786
24 October 1997 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1113923
9 September 1997 MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 786048
11 April 1997 Deficiency Check · Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1101146
30 August 1996 COI Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 961114
1 July 1995 Hull Examination · MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1187843
18 October 1993 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 848980
28 May 1993 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1132923
11 September 1992 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 950434
24 January 1992 Hull Examination · Examination of Repairs
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 954988
18 September 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1001889
3 May 1991 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1001883
5 May 1990 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 931392
7 April 1990 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1242881
12 April 1989 Initial Certification · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 893788

Deficiency record · 82

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 July 2024 Resolved
Life ring did not have retro reflective tape. Vessel rep had some on hand and corrected prior to our departure.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 29 August 2024
Resolved 29 July 2024
Resolution: Corrected on the spot.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 3 August 2021 Resolved
The PJYC has 03 vessels and they were not completing or logging abandon ship drills.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 September 2021
Resolved 3 August 2021
Resolution: Completed drills during annual inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 August 2021 Resolved
The lifering is required to have a 60' lifeline attached. The vessel did not and only had about a 12' lifeline.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 September 2021
Resolved 2 September 2021
Resolution: New life line and waterlight line puchased and installed correctly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 August 2021 Resolved
The vessel is required to have a 3-6 foot 5/8" (min) line attached to the waterlight and around the body of the lifering with a quick release clip. The vessel had a piece of string tied to the lifering and waterlight.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 September 2021
Resolved 2 September 2021
Resolution: New life line and waterlight line puchased and installed correctly.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 September 2020 Resolved
Create individual note books IAW SLIS [name withheld] FOR VESSELS OPERATING AS LAUNCHES containing the following: 1. The Special Consideration's letter 2. The vessel's COI (Copy) 3. The vessel's state registration (Copy) 4. The Vessel's Stability Letter 5. Emergency procedures for man overboard and fire onboard 6. passenger safety orientation
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2020
Resolved 11 September 2020
Resolution: Notebooks to comform with SLIS [name withheld] FOR VESSELS OPERATING AS LAUNCHES created and checked out and placed on the vessel's while underway.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 September 2020 Resolved
Fire buckets were 5 gallon vs 2.5 gallon. Recommended vessel reps drill holes half through the buckets to reduce capacity to 2.5 gallons.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 9 September 2020
Resolved 9 September 2020
Resolution: Holes drilled as recommended prior to the completion of the inspection.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 18 April 2019 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. When repairs are made during an emergency, the owner, managing operator, or master shall notify the OCMI as soon as practicable after such repairs or alternations are made. Vessel has unapproved FRP repair made to the hull in way of shaft log. Remove shaft, bearing and other associated equipment for further inspection by the attending marine inspector. 46 CFR 176.700
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 18 April 2019
Resolved 4 June 2019
Resolution: Attended vessel to inspect damage. Awaiting repair proposal.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 18 April 2019 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. When repairs are made during an emergency, the owner, managing operator, or master shall notify the OCMI as soon as practicable after such repairs or alternations are made. Vessel has unapproved FRP repairs made to the hull in way of stern tube/shaft log. Carefully remove stern tube completely for further inspection by the attending marine inspector. 46 CFR 176.700
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 26 April 2019
Resolved 11 September 2020
Resolution: Attended vessel and verified no further damamge. Approved repair. Witnessed sat. underway sea trails.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 July 2012 Resolved
Vessel currently has a extra white mast light operating when running lights are energized. Wire system to operate as per Navigation rules. vessel IS RESTIRCTED TO DAY TIME OPERATIONS ONLY.
Due 11 August 2012
Resolved 19 November 2012
Resolution: Mast light has been corrected
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 July 2012 Resolved
Provide eyewash.
Due 11 August 2012
Resolved 20 May 2013
Electrical › Electric Supply System (service) › Battery Installation
Issued 11 July 2012 Resolved
Properly secure battery in battery box to prevent movement.
Due 11 August 2012
Resolved 20 May 2013
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 11 July 2012 Resolved
Display EAP phone number and POC.
Due 11 August 2012
Resolved 12 June 2014
Resolution: Eap phone number properly posted.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 11 July 2012 Resolved
Provide proof of most recent MIS report submitted to USCG by 15 march 2012.
Due 18 July 2012
Resolved 20 May 2013
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 11 July 2012 Resolved
Provide arrangements for post causality testing.
Due 18 July 2012
Resolved 20 May 2013
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 11 July 2012 Resolved
Supervisor must completed required EAP training and provide proof of completion to MI.
Due 1 August 2012
Resolved 12 June 2014
Resolution: Training was completed and proof provided.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 19 July 2011 Resolved
Replace worn retro as needed on Life Jackets.
Condition: Improper/Lack of Maintenance
Due 19 July 2011
Resolved 19 July 2011
Resolution: Corrected on the spot
Construction/Loadline › Hull › Stiffener
Issued 17 November 2008 Resolved
Make internal spaces of vessel as well as sea valves, steering gear, shaft, and rudder available for inspection prior to refloating vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2009
Resolved 13 April 2009
Resolution: Completed satisfactory credit drydock inspection
Communications › Alarms/Indicators › Bilge Alarm
Issued 9 September 2008 Resolved
Repair bilge high water alarm. Alarm operation is intermittent.
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 3 October 2008
Resolution: Repaired.
Engineering › Freshwater System (jacketwater cooling) › Storage Tank
Issued 9 September 2008 Resolved
Repair engine coolant water recovery / storage tank. Missing internal suction hose is causing a one way flow of coolant out of closed system to the overflow tank resulting in reduced coverage of the heat exchanger coils.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 24 September 2008
Resolution: Suction tube found in bottom of tank. reinstalled and fitted w/ a clamp to secure it to the pipe nipple.
Engineering › Freshwater System (jacketwater cooling) › Level Control
Issued 9 September 2008 Resolved
Have engine checked by a competant mechanic to determine if there are any coolant leaks.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 3 October 2008
Resolution: Found sat by yard mechanic.
Lifesaving › Lifebuoys › Approval
Issued 9 September 2008 Resolved
Replace R/B aboard w/ a USCG approval # 160.050 minimum 24" device. R/B aboard is #160.046 i.e. type IV PFD for recreational vessels.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 13 April 2009
Resolution: Replaced old ring buoy with USCG approved ring buoy.
Deck/Cargo › Mooring/Anchoring › Anchor Rope
Issued 9 September 2008 Resolved
Replace oil soaked anchor line.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 30 April 2009
Resolution: Replaced oil soaked anchor line with new line.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 September 2008 Resolved
Replace first aid kit. Found soaked w/ water due to improper storage.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 October 2008
Resolved 3 October 2008
Resolution: Sat kit provided.
Documentation › Markings/Placards › Vessel Number (state)
Issued 9 September 2008 Resolved
Replace under sized Award Numbers on bow. Current numbers are 2.5" & need to be 3".
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 2 July 2009
Engineering › Steering Gear System › Ram
Issued 9 September 2008 Resolved
Steering ram cyl renewed as original prior to inspection. Old cyl had leaking piston rod seal.
Condition: Improper/Lack of Maintenance
Due 24 September 2008
Resolved 24 September 2008
Resolution: Fixed prior to inspection. Verified sat installation and tested sat.
Stability › Incline Test › General
Issued 30 January 2008 Resolved
Conduct stability test
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 November 2008
Resolved 9 September 2008
Resolution: SST conducted.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 28 September 2006 Resolved
Tamper seal missing on BII.
Due 5 October 2006
Resolved 5 October 2006
Resolution: Seal replaced.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 28 September 2006 Resolved
Replace BI extinguisher. (pull pin missing)
Due 5 October 2006
Resolved 5 October 2006
Resolution: New B I installed.
Electrical › Lighting (service) › Lighting Fixture
Issued 28 September 2006 Resolved
Secure loose deck light at gangway.
Condition: Improper/Lack of Maintenance
Due 5 October 2006
Resolved 5 October 2006
Resolution: Missing screw replaced.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 28 September 2006 Resolved
Replace worn out 60' line on ringbuoy.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 October 2006
Resolved 5 October 2006
Resolution: Replaced.
Communications › Alarms/Indicators › Bilge Alarm
Issued 28 September 2006 Resolved
Prove proper operation of bilge high water alarm.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 October 2006
Resolved 5 October 2006
Resolution: Repaired.
Engineering › Fuel Oil Storage/Transfer System › Ventilation
Issued 28 September 2006 Resolved
Replace missing 30X30 mesh flame screen on tank vent.
Condition: Improper/Lack of Maintenance
Due 5 October 2006
Resolved 5 October 2006
Resolution: Replaced flame screeen fitting.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Marking
Issued 28 September 2006 Resolved
Remove "fire extinguisher inside" sign from aft locker.
Condition: Placed in Improper Service
Due 5 October 2006
Resolved 28 September 2006
Resolution: Removed today.
Communications › Alarms/Indicators › Bilge Alarm
Issued 28 September 2005 Resolved
Prove proper operation of bilge high water alarm prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 October 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Fire Fighting › Fire Bucket › Availability
Issued 28 September 2005 Resolved
Provide 3 fire buckets with lanyards.
Due 15 October 2005
Resolved 15 October 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 September 2005 Resolved
Update first aid kit.
Due 15 October 2005
Resolved 15 October 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 28 September 2005 Resolved
Provide 2 adult lifejackets, vessel restricted to no more than 26 total persons weighing >90 lbs. until corrected.
Action required: 705 - Other - as specified
Due 15 October 2005
Resolved 15 October 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Construction/Loadline › Hull › Side Shell
Issued 25 October 2004 Resolved
Repair aft port quarter of vessel at the rubrail at upcoming drydock.
Due 30 November 2004
Resolved 27 December 2004
Construction/Loadline › Penetrations › Gasket
Issued 25 October 2004 Resolved
Rudder shaft packing is leaking, repair at the drydock.
Due 30 November 2004
Resolved 27 December 2004
Operations/Management › Drug and Alcohol Testing
Issued 15 October 2003 Resolved
Provide proof of drug testing program. LEGACY COMPONENT DESC: Employee Coverage
Due 15 October 2003
Resolved 15 October 2003
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 15 October 2003 Resolved
Conduct fire and boat drills at begining of operating season and log in logbook.
Due 1 May 2004
Resolved 25 October 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 6 September 2002 Resolved
repair deck light aft of engine box.
Condition: Unknown
Due 30 September 2002
Resolved 16 September 2002
Construction/Loadline › Hull
Issued 6 September 2002 Resolved
Make permanent repair to port qtr at intersection of transom and side shell. Epoxy patch in place. Repairs are to be completed at next drydocking. LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Due 30 April 2003
Resolved 17 March 2003
Resolution: Permanent fiberglass repair made IAW NVIC 8-87 during drydock.
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 September 2002 Resolved
Repair bilge alarm.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2002
Resolved 16 September 2002
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 September 2002 Resolved
Renew damaged items from kit & secure out of bilge.
Condition: Improper/Lack of Maintenance
Due 30 September 2002
Resolved 16 September 2002
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 September 2002 Resolved
Provide anchor light.
Condition: Improper/Lack of Maintenance
Due 30 September 2002
Resolved 16 September 2002
Lifesaving › Lifejacket/PFD (General)
Issued 6 September 2002 Resolved
Provide instructions for both types of PFDs aboard.
Condition: Improper/Lack of Maintenance
Due 30 September 2002
Resolved 16 September 2002
Lifesaving
Issued 28 August 2001 Resolved
PROVIDE FIRST AID KIT.
Condition: Unknown
Due 14 September 2001
Resolved 14 September 2001
Navigation
Issued 28 August 2001 Resolved
PROVIDE ANCHOR LIGHT.
Condition: Unknown
Due 14 September 2001
Resolved 14 September 2001
Electrical
Issued 28 August 2001 Resolved
PROVIDE COVER FOR BATTERY.
Condition: Unknown
Due 14 September 2001
Resolved 14 September 2001
Engineering
Issued 28 August 2001 Resolved
LABEL DIRECTION OF EMERGENCY FUEL SHUT OFF.
Condition: Unknown
Due 14 September 2001
Resolved 14 September 2001
Lifesaving
Issued 28 August 2001 Resolved
PROVIDE 60' OF LINE FOR RING BUOY.
Condition: Unknown
Due 14 September 2001
Resolved 14 September 2001
Construction/Loadline
Issued 28 August 2001 Resolved
REPAIR HIGH LEVEL BILGE ALARM
Condition: Unknown
Due 14 September 2001
Resolved 14 September 2001
Documentation
Issued 28 August 2001 Resolved
POST CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 14 September 2001
Resolved 14 September 2001
Construction/Loadline
Issued 15 September 2000 Resolved
RESECURE VENT PIPING TO DECK VENT COWL.
Condition: Unknown
Due 5 October 2000
Resolved 5 October 2000
Engineering
Issued 15 September 2000 Resolved
REPLACE WORN ENGINE & CLUTCH CONTROLS.
Condition: Unknown
Due 5 October 2000
Resolved 5 October 2000
Navigation
Issued 15 September 2000 Resolved
ISOLATE ANCHOR LIGHT POWER SWITCH FROM NAVIGATION LIGHT SWITCH.
Condition: Unknown
Due 5 October 2000
Resolved 5 October 2000
Fire Fighting
Issued 15 September 2000 Resolved
SERVICE ALL FIRE EXTINGUISHING EQUIPMENT ABOARD VESSEL.
Condition: Unknown
Due 5 October 2000
Resolved 5 October 2000
Fire Fighting
Issued 15 September 2000 Resolved
RESECURE FIXED CYL TO FOUNDATION FOR FIXED FE-241 SYSTEM.
Condition: Unknown
Due 5 October 2000
Resolved 5 October 2000
Electrical
Issued 15 September 2000 Resolved
RESECURE FWD DECK LIGHT TO ENGINE BOX.
Condition: Unknown
Due 5 October 2000
Resolved 5 October 2000
Engineering
Issued 5 May 1999 Resolved
MAKE VALVE(S) AVAILABLE FOR INSPECTION. IF BALL VALVE, DROP STRAINER FOR INSPECTION.
Condition: Unknown
Due 12 May 1999
Resolved 7 May 1999
Lifesaving
Issued 2 November 1998 Resolved
PROVIDE REFLECTOR TAPE ON RING BUOY.
Condition: Unknown
Due 2 November 1998
Resolved 2 November 1998
Documentation
Issued 2 November 1998 Resolved
PROVIDE MASTER'S LICENSE.
Condition: Unknown
Due 2 November 1998
Resolved 2 November 1998
Documentation
Issued 2 November 1998 Resolved
PROVIDE ORIGINAL OF CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 2 November 1998
Resolved 2 November 1998
Electrical
Issued 9 September 1997 Resolved
PROVIDE 2 FLASHLIGHTS AS EMERGENCY LIGHTING.
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Lifesaving
Issued 9 September 1997 Resolved
PROVIDE CREW TRAINING AND CREW TRAINING RECORDS.
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Navigation
Issued 9 September 1997 Resolved
REPAIR STERN LIGHT.
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Lifesaving
Issued 9 September 1997 Resolved
PROVIDE A DOT FIRST AID KIT.
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Lifesaving
Issued 9 September 1997 Resolved
PROVIDE AN ADEQUATE DRUG TESTING PROGRAM.
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Lifesaving
Issued 9 September 1997 Resolved
PROVIDE 3 ADULT PFDS.
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Lifesaving
Issued 9 September 1997 Resolved
PROVIDE A 3' - 6' LINE WITH A SNAP CLIP TO CONNECT THE RING BUOY TO THE WATERLIGHT.
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Fire Fighting
Issued 9 September 1997 Resolved
PROVIDE A REPLACEMENT FOR THE BII FIRE EXT WITH A BRACKET.
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Electrical
Issued 9 September 1997 Resolved
REPAIR BULB SOCKETS FOR DECK LIGHTS.
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Fire Fighting
Issued 30 August 1996 Resolved
REMOVE FIXED HALON SYSTEM FROM VESSEL OR REPAIR AND PROVE SYSTEM TO BE IN PROPER OPERATING CONDITION.
Condition: Unknown
Due 30 August 1996
Resolved 30 August 1996
Fire Fighting
Issued 30 August 1996 Resolved
SERVICE PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 30 August 1996
Resolved 30 August 1996
Unknown
Issued 1 July 1995 Resolved
CHANGE NY STATE REGISTRATION TO "COMMERCIAL" SERVICE.
Condition: Unknown
Due 1 July 1995
Resolved 1 July 1995
Navigation
Issued 1 July 1995 Resolved
PROVE PROPER OPERATION OF ANCHOR LIGHT.
Condition: Unknown
Due 1 July 1995
Resolved 1 July 1995
Navigation
Issued 1 July 1995 Resolved
PROPERLY STOW LIFE PRESERVERS IN FORWARD LOCKER TO PREVENT THEM FROM FALLING INTO THE BILGES.
Condition: Unknown
Due 1 July 1995
Resolved 1 July 1995
Fire Fighting
Issued 1 July 1995 Resolved
Service fixed halon extinguishing system
Condition: Unknown
Due 1 July 1995
Resolved 1 July 1995
Engineering
Issued 28 May 1993 Resolved
RETIGHTEN LAG SCREENS HOLDING FUEL TANK BRACKET IN PLACE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 July 1993
Resolved 9 July 1993
Engineering
Issued 28 May 1993 Resolved
PROPERLY SEAT PROPELLER TO TAIL SHAFT TAPER.
Condition: Unknown
Due 9 July 1993
Resolved 9 July 1993
Construction/Loadline
Issued 28 May 1993 Resolved
REMOVE OIL FROM DRIP PAN AND CLEAN BILGE.
Condition: Unknown
Due 9 July 1993
Resolved 9 July 1993

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.