Records from 1987 to 2004. Most recent: inspection, 1 April 2004.
Documentation record
Registered dimensions (L × B × D)54.0 ft × 39.2 ft × 4.0 ft
Registered tonnagegross 71 / net 71
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSUNDANCE YACHTS · GRANT, FL, UNITED STATES · built 1986
Hull materialFRP (Fiberglass)
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portPALM BEACH GARDENS, FL
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 20 June 1989 · expires 31 August 2000
Service, as the file records itUnclassified
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it71 - Simplified, Gross Ton
71 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 20
1 April 2004
Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2035384
28 December 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1108874
8 August 1997
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1118696
10 January 1997
Drydock Extension
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1096632
28 May 1996
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1087603
8 June 1995
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 879229
10 August 1994
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 863208
6 July 1994
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1173360
9 June 1993
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 831849
18 May 1993
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 841048
18 May 1993
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1173430
29 June 1992
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 946516
6 December 1991
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1251356
14 May 1991
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1306455
7 June 1990
Hull Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1239148
23 May 1989
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1040278
27 December 1988
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 890941
21 December 1987
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1005321
20 August 1987
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1337380
12 May 1987
Initial Certification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1024825
Construction/Loadline
Issued 6 July 1994
Resolved
PROVE PROPER OPERATION OF VESSELS BILGE PUMPS AND PROVIDE OPERATION INDICATOR LIGHTS AT OPERATOR STATION.
Condition: Unknown
Due 6 August 1994
Resolved 11 August 1994
Documentation
Issued 6 July 1994
Resolved
SUBMIT WRITTEN PROOF OF A CHEMICAL TESTING PROGRAM WHICH COMPLIES WITH 46 CFR PART 16 TO MSO MIAMI.
Condition: Unknown
Due 6 August 1994
Resolved 11 August 1994
Electrical
Issued 6 July 1994
Resolved
PROPERLY SUPPORT ELECTRICAL WIRING AND PAKE PROPER PRESSURE CONNECTIONS IN WAY OF ALL WIRE NUTS.
Condition: Unknown
Due 6 August 1994
Resolved 11 August 1994
Electrical
Issued 6 July 1994
Resolved
LABLE CIRCUIT BREAKER PANEL.
Condition: Unknown
Due 6 August 1994
Resolved 11 August 1994
Electrical
Issued 6 July 1994
Resolved
PROVIDE PROPER DISCONNECT PLUG FOR ALL SHORE TIES.
Condition: Unknown
Due 6 August 1994
Resolved 11 August 1994
Deck/Cargo
Issued 6 July 1994
Resolved
PROVE PROPER OPERATION OF BOARDING RAMP WINCHES.
Condition: Unknown
Due 6 August 1994
Resolved 11 August 1994
Electrical
Issued 6 July 1994
Resolved
HARD WIRE LIGHTS AND OVERHEAD FAN TO DISTRIBUTION PANEL.
Condition: Unknown
Due 6 August 1994
Resolved 11 August 1994
Documentation
Issued 6 July 1994
Resolved
POST STABILITY LETTER.
Condition: Unknown
Due 6 August 1994
Resolved 11 August 1994
Documentation
Issued 7 June 1990
Resolved
NO ONE WITH CG LICENSE IS ASSIGNED TO THE VESSEL.
Condition: Unknown
Due 7 June 1990
Resolved 7 June 1990
Documentation
Issued 27 December 1988
Resolved
PROVIDE CERTIFICATE OF DOCUMENTATION ENDORSED FOR THE COASTWISE TRADE FOR THIS VESSEL.
Condition: Unknown
Due 27 December 1988
Resolved 27 December 1988
Construction/Loadline
Issued 12 May 1987
Resolved
VESSEL TO BE DRYDOCKED NO LATER THAN 15 AUGUST 1987.
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987