MAURY USCG vessel records Sign in
← All vessels

AGIOS EMILIANOS

AGIOS EMILIANOS is a 1989 freight ship. The Coast Guard has recorded 35 inspections since 1989, most recently in November 2010, along with 21 deficiencies and 10 operational controls, 1 with no removal date recorded.

Records from 1989 to 2010. Most recent: operational control imposed, 1 November 2010.

Built
1989
Last inspected
1 November 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

8802935 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
330289
Flag
CYPRUS
—
Maury page id
psix-330289

Inspections, by type

…with no type recorded27
Years with a record 17 calendar years (1989–2010)
The 35 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it36573 - Convention (Subpart B), Gross Ton
22893 - Convention (Subpart B), Net Ton
79097 - Displacement, Ton
69392 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

OCEAN ONE Commercial Fishing Vessel · MISLE 24828 · 22 May 2006 · activity 2655744FENGLI 8 Freight Ship · MISLE 399969 · 4 February 2000 · activity 169843

Inspection history · 35

1 November 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3882652
4 June 2007 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2951320
22 May 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2655744
10 December 2005 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2549281
8 December 2005 Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2544320
26 September 2005 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2501036
20 September 2005 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2497554
14 September 2005 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2493126
9 September 2005 ISPS II Exam · MARPOL Annex V Examination · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2483251
3 March 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2303230
26 February 2005 Ballast Water Examination · PII Safety Exam · ISPS III Exam · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2299669
25 February 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2299444
25 February 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2308151
23 February 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2298256
23 February 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2298259
17 February 2005 ISPS II Exam
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2294593
14 June 2004 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2097960
8 June 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2092690
8 February 2003 Ballast Water Examination · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1740499
5 February 2003 Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 1743059
1 July 2002 MARPOL Annex I Examination · Annual Inspection · Ballast Water Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1631961
23 February 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 95828
11 February 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 274826
4 February 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 169843
22 October 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 422338
12 March 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 401050
18 January 1996 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 120334
18 January 1996 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 386908
25 October 1994 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 371591
27 May 1993 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 358427
1 June 1992 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 350969
5 August 1991 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 345207
9 November 1990 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 340204
21 March 1990 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 475312
2 May 1989 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 330161

Deficiency record · 21

Navigation › Collision/Grounding Avoidance › Radar
Issued 1 November 2010 Resolved
Sector Houston received a Deviation request for the M/V AGIOS EMILIANOS secondary marine radar.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2010
Resolution: Received a tech report attesting secondary marine radar system is working satisfactory.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 9 September 2005 Resolved
Fireman's outfits were worn/wasted. SOLAS 74 (amend.) II-2/17.1.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 December 2005
Resolution: Fire suits have been replaced with class approval
Engineering › Diesel Engine (propulsion-direct drive) › Pump, High Pressure (fuel injection)
Issued 14 June 2004 Resolved
3 High Pressure lines on the main engine need to be replaced (Lube Oil). Prior to next U.S. Port. Resolution extended to next U.S. Port or 75 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 February 2005
Resolution: Hydraulic lines replaced and confirmed by LKCD, 14FEB05.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 June 2004 Resolved
Oxygen bottle must be replaced or recharged in Hospital space prior to next U.S. Port, ILO 147
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 June 2004
Resolution: Oxygen bottle refilled to the satisfaction of class.
Navigation › Collision/Grounding Avoidance › Radar
Issued 8 February 2003 Resolved
Vessel issued Letter of Deviation for inoperative radar.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2003
Resolution: Necessary repairs made, vessel cleared to sail.
Fire Fighting
Issued 12 March 1997 Resolved
Remove the tie backs and blocks holding the fire doors open on the house stair wells and the doors leading to the emergency fire pump space and escape tower from the machinery spaces. Complete prior to return to a U. S. port. SOLAS 74 amd II-2/47.2
Condition: Unknown
Due 20 March 1997
Resolved 24 March 1997
Lifesaving
Issued 12 March 1997 Resolved
Make permanent repairs to the local control station for lowering the stbd lifeboat. The electrical controls are inoperative and must be operated from a remote station within the ship. Complete prior to return to a U. S.port. SOLAS 74 amd III/45.3
Condition: Unknown
Due 20 March 1997
Resolved 24 March 1997
Deck/Cargo
Issued 12 March 1997 Resolved
Make permanent repairs to the leaking hydraulic seal on the port anchor windlass drive prior to return to a U. S. port. _x001C_ _x001C_ 33 CFR 151.10(b)
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Engineering
Issued 12 March 1997 Resolved
Almost all engineering (service & head) oil tanks have the automatic closing valves disabled in the open position. Remove the supplemental instruments to allow valves to remain closed. Complete prior to return to a U. S. port. SOLAS 74 amd I/11
Condition: Unknown
Due 20 March 1997
Resolved 24 March 1997
Electrical
Issued 12 March 1997 Resolved
Remove the heat lamps and associated wiring on the main engine pumps. Install class approved heat strips if heating of motor is required. Complete prior to return to a U. S. port. _x001C_ SOLAS 74 amd II-1/45
Condition: Unknown
Due 20 March 1997
Resolved 24 March 1997
Fire Fighting
Issued 12 March 1997 Resolved
Remove all paint from the focsle space to the approved paint locker prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 74 amd II-2/18.7
Condition: Unknown
Due 20 March 1997
Resolved 24 March 1997
Engineering
Issued 12 March 1997 Resolved
Make permanent repairs to the patched piping on the M/W jacket water heat exchanger (2 locations) and the port diesel generator engine cooling line (1 location). Complete prior to return to a U. S. port._x001C_ SOLAS 74 amd II-1/26.1
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Fire Fighting
Issued 12 March 1997 Resolved
Make permanent repairs to the emergency fire pump vacuum pump and prove proper operation prior to departure. _x001C_ _x001C_ SOLAS 74 amd II-2/4.3.3.2
Condition: Unknown
Due 20 March 1997
Resolved 24 March 1997
Lifesaving
Issued 18 January 1996 Resolved
Port lifeboat failed to start. Correct to the satisfaction of the class society prior to depature from Tacoma, WA. USA. SOLAS 74 III/41.6
Condition: Unknown
Due 25 January 1996
Resolved 30 January 1996
Fire Fighting
Issued 18 January 1996 Resolved
Emergency fire pump failed to take suction. Correct to the satisfaction ofthe class society prior to depature from Tacoma, Washington, United States.SOLAS74 II-2/4.3.3
Condition: Unknown
Due 25 January 1996
Resolved 30 January 1996
Lifesaving
Issued 18 January 1996 Resolved
Remove flammables and corrosives from steering gear roommmm prior to returnto United States.
Condition: Unknown
Due 14 March 1997
Resolved 14 March 1997
Fire Fighting
Issued 18 January 1996 Resolved
Paint Store Room has fixed CO2 system installed and it is not reflected on the Fire Control Plan. Update Fire Control Plan prior to return to United States. SOLAS II-2/Reg 20
Condition: Unknown
Due 14 March 1997
Resolved 14 March 1997
Construction/Loadline
Issued 25 October 1994 Resolved
SOLAS CHAPTER I REG 11
Condition: Unknown
Due 23 January 1996
Resolved 23 January 1996
Navigation
Issued 25 October 1994 Resolved
US COAST PILOT VOL 3 MISSING CORRECTIONS/BA NP 69 VOL II MISSING CORRECTIONS.
Condition: Unknown
Due 23 January 1996
Resolved 23 January 1996
Documentation
Issued 27 May 1993 Resolved
33 CFR 151.57 Vessel did not have a waste management plan. Vessel's master agreed to create a plan prior to departure._x001C_
Condition: Unknown
Due 28 May 1993
Resolved 28 May 1993
Documentation
Issued 2 May 1989 Resolved
OIL TRANSFER PROCEDURES MISSING LIST OF PRODUCTS TRANSFERRED AND PROCEDURES FOR TOPPING OFF TANKS. A REQUIREMENT OF 33CFR155.750.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989

Ownership record