Records from 2016 to 2025. Most recent: inspection, 8 October 2025.
Inspection history · 15
8 October 2025
Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8247462
19 December 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8048509
6 December 2023
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7834593
5 October 2023
Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7804550
28 September 2022
COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7559036
20 December 2021
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7363587
20 October 2021
Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7300742
11 January 2021
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7121287
10 January 2020
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6887021
30 October 2019
Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6815263
13 December 2018
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6596175
25 October 2017
Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6296456
10 October 2017
DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6280571
9 January 2017
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6067296
14 January 2016
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5797403
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 20 December 2021
Resolved
When Life floats are stowed in tiers, the separate units
must be kept apart by spacers. Life floats were not
separated by spacers. Separate life floats by spacers to
satisfaction of attending Marine Inspector.
Action required: 10 - Deficiency Rectified
Resolved 20 December 2021
Resolution: Separated life floats by spacers to satisfaction of attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 December 2021
Resolved
Each ring life buoy on a vessel must be approved in
accordance with § 160.050 in sub-chapter Q of 46 CFR, or
other standard specified by the Commandant, including,
but not limited to, approval series 160.150. 01 life
buoy grab-line was wasted. Make grab line satisfactory
and to manufacturer specifications.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 January 2022
Resolved 14 January 2022
Resolution: Satisfactory life buoy in service. Replaced life buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 December 2021
Resolved
Placards containing instructions for the donning and use
of the life jackets aboard the vessel must be posted in
conspicuous places that are regularly accessible and
visible to the crew and passengers. Missing donning
placard for a type of life jacket available on-board.
Display placard as required and to the satisfaction of
attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 January 2022
Resolved 21 December 2021
Resolution: Received objective evidence from O/O showing proper life-jacket donning placard.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 20 December 2021
Resolved
A vessel must carry either a first-aid kit approved
under approval series 160.041 or a kit with equivalent
contents and instructions. First-aid kit was missing
some components due to expiration. Make kit satisfactory
with correct/un-expired equivalent contents available
for inspection by attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 January 2022
Resolved 3 January 2022
Resolution: Received objective evidence from O/O showing proper first-aid kit items.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 January 2021
Resolved
Replace port running light lens.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2021
Resolved 14 January 2021
Resolution: Vessel replaced lens cover.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 11 January 2021
Resolved
Provide alcohol testing kits.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2021
Resolved 1 February 2021
Resolution: Vessel provided alcohol swabs.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 January 2020
Resolved
Mount fire extinguisher adjacent to operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 January 2020
Resolved 16 January 2020
Resolution: Vessel mounted bracket and extinguisher.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 16 January 2020
Resolved
Demonstrate proper operation of engine room bilge high level alarm.
Action required: 10 - Deficiency Rectified
Due 16 January 2020
Resolved 16 January 2020
Resolution: Vessel replaced bilge high level alarm,
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 January 2020
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel was not made available for inspection within 3 months of anniversary date (10 OCT). Make vessel available and complete annual reinspection prior to carriage of passengers or cargo.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 January 2020
Resolved 16 January 2020
Resolution: Vessel completed annual inspection on 16JAN2020.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 December 2018
Resolved
REPLACE WATER LIGHT LINE.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2019
Resolved 4 January 2019
Resolution: Line replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 December 2018
Resolved
REPLACE GRAB LINES ON RING BUOY OR REPLACE RING BUOY.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2019
Resolved 4 January 2019
Resolution: Lifering renewed.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 13 December 2018
Resolved
REPLACE HYDRO ON EPIRB, EXPIRES 01/19.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2019
Resolved 4 January 2019
Resolution: Hydro replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 13 December 2018
Resolved
REPLACE GASKET ON FOREPEAK HATCH.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2019
Resolved 11 January 2019
Resolution: Gasket replaced
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 13 December 2018
Resolved
PROVIDE NOAA REGISTRATION FOR EPIRB.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2019
Resolved 4 January 2019
Resolution: Registration provided.
Lifesaving › Lifefloat › Retroreflective Material
Issued 10 October 2017
Resolved
Renew retro tape on lifefloats.
Action required: 705 - Other - as specified
Due 10 November 2017
Resolved 25 October 2017
Resolution: Tape was renewed.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 10 October 2017
Resolved
Provide brackets for watertights for the lifefloats and lifering.
Action required: 705 - Other - as specified
Due 10 November 2017
Resolved 25 October 2017
Resolution: Brackets were provided.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 January 2017
Resolved
Prove proper operation of port & starboard side lights. Vessel restricted to daylight operation and unrestricted visibility.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 February 2017
Resolved 24 January 2017
Communications › Radio Communications › EPIRB
Issued 9 January 2017
Resolved
Replace EPIRB hydro release NLT 01FEB17
Action required: 705 - Other - as specified
Due 1 February 2017
Resolved 24 January 2017
Communications › Radio Communications › EPIRB
Issued 9 January 2017
Resolved
Replace EPIRB battery NLT 01APR17
Action required: 705 - Other - as specified
Due 1 April 2017
Resolved 24 January 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 January 2016
Resolved
Provide first aid kit that meets 46 CFR 160.041.
Action required: 705 - Other - as specified
Due 14 February 2016
Resolved 21 January 2016
Resolution: New first aid kit on board.
Lifesaving › Lifebuoys › Immediately Available
Issued 14 January 2016
Resolved
Properly mount lifering in accessible location.
Action required: 705 - Other - as specified
Due 14 February 2016
Resolved 14 January 2016
Resolution: Lifering properly mounted near the helm.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 14 January 2016
Resolved
Make shaft penetration of aft E/R bulkhead reasonably gas tight.
Action required: 705 - Other - as specified
Due 14 February 2016
Resolved 14 January 2016
Resolution: Wood block re-installed to make E/R bulkhead reasonably gas tight.