MAURY USCG vessel records Sign in
← All vessels

ATLANTIC

ATLANTIC is a 1978 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 2008, most recently in July 2024, along with 33 deficiencies — 1 with no resolution recorded —.

Records from 2008 to 2024. Most recent: inspection, 31 July 2024.

Built
1978
Last inspected
31 July 2024
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDK4073
330526
Flag
UNITED STATES
368051560
Maury page id
psix-330526

Inspections, by type

…past their stated due date1
Years with a record 12 calendar years (2008–2024)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)60.0 ft × 17.0 ft × 6.5 ft
Registered tonnagegross 44 / net 35
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBALDWINSVILLE BOATYARD · BALDWINSVILLE, NY, UNITED STATES · built 1978
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portCHERRYFIELD, ME
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 1 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it44 - Simplified, Gross Ton
35 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK4073MMSI 368051560 · active · compulsorily equipped · granted 24 July 2018, expires 24 July 2028
WDE3935MMSI 367346210 · expired · compulsorily equipped · granted 1 April 2008, cancelled 2 June 2018 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 19

31 July 2024 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7974711
22 July 2022 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7558574
29 April 2022 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7448202
22 July 2021 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7165407
8 April 2020 Drydock Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6937372
30 December 2019 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6880447
11 July 2019 Plan Review "T" Boat · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6755143
5 November 2018 Simplified Stability Test
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6576800
3 July 2018 Deficiency Check · Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6465232
25 September 2015 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5730588
25 September 2015 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5734164
24 June 2014 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4924904
22 May 2012 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4312732
3 January 2012 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4217563
12 October 2010 Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3868329
23 February 2009 Construction Oversight
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3427585
9 June 2008 Simplified Stability Test
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3254758
6 June 2008 Simplified Stability Test
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3249706
30 May 2008 Hull Examination · Initial Certification · COI Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3225301

Deficiency record · 33

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 July 2022 No resolution recorded
Complete inservice inspection prior to carry passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2024 — due date passed with no resolution recorded
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 August 2019 Resolved
Vessel's Sternlight was not properly attached. Deficiency was corrected on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 August 2019
Resolved 13 August 2019
Resolution: Vessel fixed light on the spot.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 August 2019 Resolved
Re-label upper deck restriction to read 20. Currently the restriction reads 36.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 September 2019
Resolved 17 September 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 August 2019 Resolved
Permanently secure lifejacket box. Box is shifting and only held by line.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 September 2019
Resolved 17 September 2019
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 July 2019 Resolved
Upper deck fire nozzle clogged with debris during testing resulting in low water flow from nozzle. Proved proper stream of water from upper deck fire station.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 August 2019
Resolved 13 August 2019
Resolution: Fire main flushed and tested sat.
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 19 November 2018 Resolved
The door leading out to the bow is not weathertight. The scuttle on the bow, leading to the forepeak is not watertight. Replace or repair as needed, prior to operation on a paritally protected route.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 July 2019
Resolution: Replaced fwd scuttle with new gasket and bolt down cover.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 19 November 2018 Resolved
Fixed seating requirements to be submitted to OCMI, and seating must be measured and weighed to comply with CFR and SST requirements.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2019
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 19 November 2018 Resolved
Vsl to secure the ballast (concrete blocks) located in Voids #2 & #3 against shifting or movement.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 July 2019
Resolution: Ballast strapped down.
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 13 August 2018 Resolved
Seal the Transducer thru hull penetration to make it watertight.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 17 July 2019
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 13 August 2018 Resolved
Provide a valid Safety Radio Telephony Cert.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2019
Resolution: Done
02 - Structural Conditions › N/A - No Subsystem › Permanent means of access
Issued 13 August 2018 Resolved
Provide improved Emergency Egress route on the forecastle to upper decking, provide steps and hand holds for passengers to use.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 July 2019
Resolution: Ladder way installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 July 2018 Resolved
Steering hoses are not SAE J-1942 rated and run from the Laz to the pilot house; hoses to be replaced utilizing approved hoses.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 17 July 2019
Resolution: Hoses replaced with J1942 rated hoses.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 September 2015 Resolved
AM01: Complete satisfactory annual inspection prior to operating with passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 October 2015
Resolution: Completed satisfactory annual inspection.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 September 2015 Resolved
Complete satisfactory annual inspection prior to operating with passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 October 2015
Resolution: Completed satisfactory annual inspection.
Engineering › Bilge Water Management System › Not Operational
Issued 25 September 2015 Resolved
AM01: Provide proper operation of bilge pump and piping; #1 comp was not able to pump out. PTCP
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 October 2015
Resolution: Vsl demonstrated proper operation of bilge pump and piping in all 5 spaces- all SAT.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 24 June 2014 Resolved
Supervisor must have EAP drug/alcohol awareness training
Action required: 705 - Other - as specified
Due 24 July 2014
Resolved 17 July 2014
Resolution: Vessel conducted training via consortium DVD
Lifesaving › Lifebuoys › Not on Board
Issued 24 June 2014 Resolved
Vessel must have 24" ring lifebouy
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 July 2014
Resolution: Vessel purchased ring buoy
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 24 June 2014 Resolved
vessel limited to 69 passengers due to available life jackets
Action required: 705 - Other - as specified
Resolved 22 November 2017
Resolution: Vessel is still in the yard and for sale; owner requested to be taken out of service.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 June 2014 Resolved
Vessel must have water light for ring buoy to operate after daylight hours
Action required: 705 - Other - as specified
Due 4 July 2014
Resolved 4 July 2014
Resolution: purchased water light
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 22 May 2012 Resolved
Provide FCC Saety Radio Certificate
Action required: 705 - Other - as specified
Due 1 June 2012
Resolved 21 June 2012
Resolution: Recieved cpoy of valid FCC Safety Radio certificate
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 30 May 2008 Resolved
Conduct underway exercises (man overboard and fire) with permanent crew prior to operating wit passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 June 2008
Resolved 10 June 2008
Electrical › Electrical Distribution System (service) › Busway
Issued 30 May 2008 Resolved
Secure loose conduit in E/R (some taped, some loose).
Due 9 July 2008
Resolved 19 July 2008
Engineering › Fuel Oil Service System › Ventilation
Issued 30 May 2008 Resolved
Provide ventilation fo F/O tank space IAW 46 CFR 182.470(i).
Due 9 July 2008
Resolved 28 July 2008
Engineering › Generator (propulsion-electric) › Battery
Issued 30 May 2008 Resolved
Cover generator battery box - leads exposed, also generator leads exposed as well.
Due 9 July 2008
Resolved 19 July 2008
Documentation › Markings/Placards › Capacity Marking
Issued 30 May 2008 Resolved
Stencil upperdeck for 38 passengers IAW 46 CFR 185.604(a).
Due 9 June 2008
Resolved 19 July 2008
Engineering › Fuel Oil Service System › Hose
Issued 30 May 2008 Resolved
Prove F/O flex hose is an approved type.
Due 9 July 2008
Resolved 20 July 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 May 2008 Resolved
Resubmit electrical plans IAW 42CFR183.340
Due 9 July 2008
Resolved 28 July 2008
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 30 May 2008 Resolved
Overcurrent protection appropriately sized not to excedd 150% of conductor load (amperage).
Due 9 July 2008
Resolved 14 June 2008
Construction/Loadline › Structures › Door
Issued 30 May 2008 Resolved
Door widths, provide one door at 32" width, or all four doors at 30".
Due 15 April 2009
Resolved 23 February 2009
Resolution: Replaced the forward door.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 30 May 2008 Resolved
Provide hand operated (10GPM) bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2008
Resolved 11 June 2008
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 30 May 2008 Resolved
Provide list of spaces next to bilge alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2008
Resolved 11 June 2008
Engineering › Diesel Engine (propulsion-direct drive) › Gear, Timing
Issued 30 May 2008 Resolved
Provide pulleyguard on port engine.
Due 9 July 2008
Resolved 28 July 2008
Construction/Loadline › Structures › Ventilators
Issued 30 May 2008 Resolved
Provide means of closing E/R vents for fixed fire fighting agent discharge.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 June 2008
Resolved 11 June 2008

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.