Records from 2018 to 2024. Most recent: inspection, 31 July 2024.
Documentation record
Registered dimensions (L × B × D)60.0 ft × 17.0 ft × 6.5 ft
Registered tonnagegross 44 / net 35
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBALDWINSVILLE BOATYARD · BALDWINSVILLE, NY, UNITED STATES · built 1978
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portCHERRYFIELD, ME
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 1 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it44 - Simplified, Gross Ton
35 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 9
31 July 2024
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7974711
22 July 2022
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7558574
29 April 2022
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7448202
22 July 2021
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7165407
8 April 2020
Drydock Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6937372
30 December 2019
Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6880447
11 July 2019
Plan Review "T" Boat · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6755143
5 November 2018
Simplified Stability Test
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6576800
3 July 2018
Deficiency Check · Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6465232
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 July 2022
No resolution recorded
Complete inservice inspection prior to carry passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2024 — due date passed with no resolution recorded
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 August 2019
Resolved
Vessel's Sternlight was not properly attached. Deficiency was corrected on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 August 2019
Resolved 13 August 2019
Resolution: Vessel fixed light on the spot.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 August 2019
Resolved
Re-label upper deck restriction to read 20. Currently the restriction reads 36.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 September 2019
Resolved 17 September 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 August 2019
Resolved
Permanently secure lifejacket box. Box is shifting and only held by line.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 September 2019
Resolved 17 September 2019
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 July 2019
Resolved
Upper deck fire nozzle clogged with debris during testing resulting in low water flow from nozzle. Proved proper stream of water from upper deck fire station.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 August 2019
Resolved 13 August 2019
Resolution: Fire main flushed and tested sat.
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 19 November 2018
Resolved
The door leading out to the bow is not weathertight. The scuttle on the bow, leading to the forepeak is not watertight. Replace or repair as needed, prior to operation on a paritally protected route.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 July 2019
Resolution: Replaced fwd scuttle with new gasket and bolt down cover.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 19 November 2018
Resolved
Fixed seating requirements to be submitted to OCMI, and seating must be measured and weighed to comply with CFR and SST requirements.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2019
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 19 November 2018
Resolved
Vsl to secure the ballast (concrete blocks) located in Voids #2 & #3 against shifting or movement.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 July 2019
Resolution: Ballast strapped down.
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 13 August 2018
Resolved
Seal the Transducer thru hull penetration to make it watertight.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 17 July 2019
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 13 August 2018
Resolved
Provide a valid Safety Radio Telephony Cert.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2019
Resolution: Done
02 - Structural Conditions › N/A - No Subsystem › Permanent means of access
Issued 13 August 2018
Resolved
Provide improved Emergency Egress route on the forecastle to upper decking, provide steps and hand holds for passengers to use.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 July 2019
Resolution: Ladder way installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 July 2018
Resolved
Steering hoses are not SAE J-1942 rated and run from the Laz to the pilot house; hoses to be replaced utilizing approved hoses.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 17 July 2019
Resolution: Hoses replaced with J1942 rated hoses.