Records from 2008 to 2024. Most recent: inspection, 31 July 2024.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 19
31 July 2024
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7974711
22 July 2022
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7558574
29 April 2022
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7448202
22 July 2021
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7165407
8 April 2020
Drydock Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6937372
30 December 2019
Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6880447
11 July 2019
Plan Review "T" Boat · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6755143
5 November 2018
Simplified Stability Test
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6576800
3 July 2018
Deficiency Check · Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6465232
25 September 2015
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5730588
25 September 2015
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5734164
24 June 2014
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4924904
22 May 2012
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4312732
3 January 2012
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4217563
12 October 2010
Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3868329
23 February 2009
Construction Oversight
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3427585
9 June 2008
Simplified Stability Test
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3254758
6 June 2008
Simplified Stability Test
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3249706
30 May 2008
Hull Examination · Initial Certification · COI Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3225301
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 July 2022
No resolution recorded
Complete inservice inspection prior to carry passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2024 — due date passed with no resolution recorded
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 August 2019
Resolved
Vessel's Sternlight was not properly attached. Deficiency was corrected on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 August 2019
Resolved 13 August 2019
Resolution: Vessel fixed light on the spot.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 August 2019
Resolved
Re-label upper deck restriction to read 20. Currently the restriction reads 36.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 September 2019
Resolved 17 September 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 August 2019
Resolved
Permanently secure lifejacket box. Box is shifting and only held by line.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 September 2019
Resolved 17 September 2019
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 July 2019
Resolved
Upper deck fire nozzle clogged with debris during testing resulting in low water flow from nozzle. Proved proper stream of water from upper deck fire station.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 August 2019
Resolved 13 August 2019
Resolution: Fire main flushed and tested sat.
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 19 November 2018
Resolved
The door leading out to the bow is not weathertight. The scuttle on the bow, leading to the forepeak is not watertight. Replace or repair as needed, prior to operation on a paritally protected route.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 July 2019
Resolution: Replaced fwd scuttle with new gasket and bolt down cover.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 19 November 2018
Resolved
Fixed seating requirements to be submitted to OCMI, and seating must be measured and weighed to comply with CFR and SST requirements.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2019
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 19 November 2018
Resolved
Vsl to secure the ballast (concrete blocks) located in Voids #2 & #3 against shifting or movement.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 July 2019
Resolution: Ballast strapped down.
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 13 August 2018
Resolved
Seal the Transducer thru hull penetration to make it watertight.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 17 July 2019
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 13 August 2018
Resolved
Provide a valid Safety Radio Telephony Cert.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2019
Resolution: Done
02 - Structural Conditions › N/A - No Subsystem › Permanent means of access
Issued 13 August 2018
Resolved
Provide improved Emergency Egress route on the forecastle to upper decking, provide steps and hand holds for passengers to use.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 July 2019
Resolution: Ladder way installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 July 2018
Resolved
Steering hoses are not SAE J-1942 rated and run from the Laz to the pilot house; hoses to be replaced utilizing approved hoses.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 17 July 2019
Resolution: Hoses replaced with J1942 rated hoses.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 September 2015
Resolved
AM01: Complete satisfactory annual inspection prior to operating with passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 October 2015
Resolution: Completed satisfactory annual inspection.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 September 2015
Resolved
Complete satisfactory annual inspection prior to operating with passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 October 2015
Resolution: Completed satisfactory annual inspection.
Engineering › Bilge Water Management System › Not Operational
Issued 25 September 2015
Resolved
AM01: Provide proper operation of bilge pump and piping; #1 comp was not able to pump out. PTCP
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 October 2015
Resolution: Vsl demonstrated proper operation of bilge pump and piping in all 5 spaces- all SAT.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 24 June 2014
Resolved
Supervisor must have EAP drug/alcohol awareness training
Action required: 705 - Other - as specified
Due 24 July 2014
Resolved 17 July 2014
Resolution: Vessel conducted training via consortium DVD
Lifesaving › Lifebuoys › Not on Board
Issued 24 June 2014
Resolved
Vessel must have 24" ring lifebouy
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 July 2014
Resolution: Vessel purchased ring buoy
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 24 June 2014
Resolved
vessel limited to 69 passengers due to available life jackets
Action required: 705 - Other - as specified
Resolved 22 November 2017
Resolution: Vessel is still in the yard and for sale; owner requested to be taken out of service.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 June 2014
Resolved
Vessel must have water light for ring buoy to operate after daylight hours
Action required: 705 - Other - as specified
Due 4 July 2014
Resolved 4 July 2014
Resolution: purchased water light
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 22 May 2012
Resolved
Provide FCC Saety Radio Certificate
Action required: 705 - Other - as specified
Due 1 June 2012
Resolved 21 June 2012
Resolution: Recieved cpoy of valid FCC Safety Radio certificate
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 30 May 2008
Resolved
Conduct underway exercises (man overboard and fire) with permanent crew prior to operating wit passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 June 2008
Resolved 10 June 2008
Electrical › Electrical Distribution System (service) › Busway
Issued 30 May 2008
Resolved
Secure loose conduit in E/R (some taped, some loose).
Due 9 July 2008
Resolved 19 July 2008
Engineering › Fuel Oil Service System › Ventilation
Issued 30 May 2008
Resolved
Provide ventilation fo F/O tank space IAW 46 CFR 182.470(i).
Due 9 July 2008
Resolved 28 July 2008
Engineering › Generator (propulsion-electric) › Battery
Issued 30 May 2008
Resolved
Cover generator battery box - leads exposed, also generator leads exposed as well.
Due 9 July 2008
Resolved 19 July 2008
Documentation › Markings/Placards › Capacity Marking
Issued 30 May 2008
Resolved
Stencil upperdeck for 38 passengers IAW 46 CFR 185.604(a).
Due 9 June 2008
Resolved 19 July 2008
Engineering › Fuel Oil Service System › Hose
Issued 30 May 2008
Resolved
Prove F/O flex hose is an approved type.
Due 9 July 2008
Resolved 20 July 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 May 2008
Resolved
Resubmit electrical plans IAW 42CFR183.340
Due 9 July 2008
Resolved 28 July 2008
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 30 May 2008
Resolved
Overcurrent protection appropriately sized not to excedd 150% of conductor load (amperage).
Due 9 July 2008
Resolved 14 June 2008
Construction/Loadline › Structures › Door
Issued 30 May 2008
Resolved
Door widths, provide one door at 32" width, or all four doors at 30".
Due 15 April 2009
Resolved 23 February 2009
Resolution: Replaced the forward door.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 30 May 2008
Resolved
Provide hand operated (10GPM) bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2008
Resolved 11 June 2008
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 30 May 2008
Resolved
Provide list of spaces next to bilge alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2008
Resolved 11 June 2008
Engineering › Diesel Engine (propulsion-direct drive) › Gear, Timing
Issued 30 May 2008
Resolved
Provide pulleyguard on port engine.
Due 9 July 2008
Resolved 28 July 2008
Construction/Loadline › Structures › Ventilators
Issued 30 May 2008
Resolved
Provide means of closing E/R vents for fixed fire fighting agent discharge.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 June 2008
Resolved 11 June 2008