ADVENTURE I

ADVENTURE I is a 1989 passenger vessel (inspected). The Coast Guard has recorded 54 inspections since 1989, most recently in June 2026, along with 84 deficiencies and 1 operational control.

Records from 1989 to 2026. Most recent: inspection, 18 June 2026.

Built
1989
Last inspected
18 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDA4956
330579
Flag
UNITED STATES
366814970
Maury page id
psix-330579

Inspections, by type

…with no type recorded1
Years with a record 33 calendar years (1989–2026)
The 54 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)40.0 ft × 12.0 ft × 3.0 ft
Registered tonnagegross 6 / net 6
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCORINTHIAN YACHTS INC · TARPON SPRINGS, FL, UNITED STATES · built 1989
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeNot recorded
Hull configurationTwin Hull
Hailing portST PETE BEACH, FL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 11 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it6 - Simplified, Gross Ton
6 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP6052MMSI 366814970 · active · compulsorily equipped · granted 22 May 2024, expires 22 May 2034 · licensed under a name not among this hull’s recorded names (not shown)
WDA4956MMSI 366814970 · cancelled · voluntarily equipped · granted 2 June 2021, cancelled 16 May 2024
WAEPMMSI 366816040 · cancelled · compulsorily equipped · granted 20 June 2001, cancelled 4 April 2011 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 54

18 June 2026 Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8381666
8 June 2025 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8152540
22 January 2025 Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8049211
21 May 2024 Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7901871
7 March 2023 COI Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7639401
17 January 2023 Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7607770
19 May 2022 Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7446584
5 May 2021 Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7190209
16 December 2020 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7112683
18 June 2020 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6938786
16 April 2019 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6658345
7 January 2019 Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6584472
19 April 2018 COI Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6394676
20 April 2017 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6121082
6 January 2017 In-Service Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6048591
15 January 2016 DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5795333
26 January 2012 Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4231967
3 February 2011 DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3937999
25 January 2011 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3932171
7 May 2009 DAPI Audit · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3466964
6 January 2009 Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3389786
15 April 2008 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3184315
19 November 2007 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3100974
13 April 2007 Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2906396
5 January 2007 Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2849930
3 March 2006 Deficiency Check · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2595476
8 September 2005 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2486868
8 March 2005 Deficiency Check · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2307347
7 January 2005 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2273191
8 March 2004 Annual Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2017140
7 July 2003 Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1841499
19 June 2003 Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1825102
10 January 2003 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1725618
11 June 2002 Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1604890
23 April 2001 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1066511
8 March 2001 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1379346
19 January 2001 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1448217
19 May 2000 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1472040
12 April 1999 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1416952
21 January 1999 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1416951
9 March 1998 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1364738
1 February 1998 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 781678
22 January 1997 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1453389
14 March 1996 Re-Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1082099
1 February 1995 COI Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 847293
14 July 1994 COI Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1327884
23 June 1994 COI Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1321733
17 June 1994 Hull Examination
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1014318
17 June 1994 Hull Examination
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1328076
9 March 1993 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 835810
4 February 1992 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 947049
1 August 1991 Administrative
Administrative · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1247116
22 May 1991 Re-Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 921974
23 May 1989 Initial Certification · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 899204

Deficiency record · 84

04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 18 June 2026 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. MI observed no instructions mounted. Rectify to the satisfaction of the attending MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2026
Resolved 22 June 2026
Resolution: O/O provided photo evidence of updated emergency instructions.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 June 2026 Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. MI observed no maintenance records for portable fire extinguishers. Rectify to the satisfaction of the attending MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2026
Resolved 22 June 2026
Resolution: O/O provided maintenance log for portable fire extinguishers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 June 2025 Resolved
USCG Type A1, A2, B1, or B2 flexible hose may be accepted. MI noted weathered and worn sections of flexible fuel hose on starboard side of fuel tank from the shutoff valve to fuel filter and to priming bulb. Replace worn sections of fuel hose with approved type. 46 CFR 182.720(e)(3)(v)(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2025
Resolved 13 June 2025
Resolution: Received satisfactory photo evidence of correction.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 12 June 2025 Resolved
The required fire extinguisher maintenance (monthly checks) shall be logged. MI observed insufficient proof that maintenance was being performed. 46 CFR 176.810(b)(1)(iv)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2025
Resolved 13 June 2025
Resolution: Received satisfactory photo evidence of correction.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 12 June 2025 Resolved
Each EPIRB must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative, and shall be logged. MI observed insufficient proof that maintenance was being performed. 46 CFR 185.728(a),(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2025
Resolved 13 June 2025
Resolution: Received satisfactory photo evidence of correction.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 June 2025 Resolved
Vessel must undergo an annual inspection as specified in paragraph (b)(1) of this section. Vessel must undergo an annual inspection within 3 months before or after the each anniversary date. Vessels anniversary date was March 7th, 2025, and vessel is past 3 months from said date. Vessel shall not operate with passengers until an annual inspection has been complete. 46CFR176.500(b)
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2025
Resolved 12 June 2025
Resolution: Vessel completed satisfactory annual inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 May 2024 Resolved
At least one ring life buoy must be fitted with a lifeline. Each lifeline on a ring life buoy must: Have a breaking strength of at least 5 kilonewtons (1,124 pounds) MI Observed the lifeline on the life ring to be deteriorated. Vessel must replace lifeline prior to carrying passengers. 46 CFR 180.70(C)(5)
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 May 2024
Resolved 22 May 2024
Resolution: Vessel replaced lifeline.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 21 May 2024 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. MI observed a cracked weld on the rescue platform. Vessel must rectify prior to carrying passengers. 46 CFR 185.70
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 May 2024
Resolved 23 May 2024
Resolution: Vessel provided proof of repaired weld on rescue ladder.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 May 2024 Resolved
Each floating waterlight installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip. Vessel restricted to daylight operations until deficiency is rectified. 46 CFR 180.70(D)(3)
Action required: 705 - Other - as specified
Due 21 May 2024
Resolved 22 May 2024
Resolution: Vessel replaced Clip.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 May 2024 Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. MI Observed the incorrect batteries in the floating waterlight. Vessel restricted to daylight operations until deficiency is rectified. 46 CFR 180.70(D)(1)
Action required: 705 - Other - as specified
Due 21 May 2024
Resolved 22 May 2024
Resolution: Vessel replaced batteries
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 May 2024 Resolved
The discharge ends of vent pipes shall be fitted with removable flame screens or flame arresters. MI observed a lack of a flame screen on the fuel vents. 46 CFR 182.15-35
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2024
Resolved 30 May 2024
Resolution: Vessel sent visual proof of flame screens.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 March 2023 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. Sluice valves are not permitted in watertight bulkheads. The submersible electric bilge pump in the port side compartment number 3 was inoperable when tested. 46 CFR 182.500
Action required: 705 - Other - as specified
Due 14 March 2023
Resolved 7 March 2023
Resolution: The operator purchased a new UL listed 2000 GPH and installed it in the port side compartment number 3. The pump was operationally tested and verified to be operational during the MI attendance.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 March 2023 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. The child life jackets and adult life jackets were found stored together in a centerline portable container without separation or identifiable markings to distinguish between the two. 46 CFR 180.78
Action required: 705 - Other - as specified
Due 14 March 2023
Resolved 9 March 2023
Resolution: The operator placed a piece of wood between the adult life jackets and child life jackets inside of the container. The front of the container has the required markings and the inside of the lid has markings to identify child or adult as well.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 March 2023 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. The FCC station authorization was found expired and is issued for the EPIRB and VHF. 46 CFR 184.502
Action required: 705 - Other - as specified
Due 14 March 2023
Resolved 9 March 2023
Resolution: The FCC technician attended the vessel and issued a new FCC station certificate.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 March 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to: Provide services necessary for safety under normal and emergency conditions; Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; Minimize accidental personnel contact with energized parts; and prevent electrical ignition of flammable vapors. The operator installed an inverter without plan approval. It was also discovered that the primary overcurrent protection for the DC circuit was never installed on this vessel. The conductor providing primary power is an 8AWG marine grade conductor. 46 CFR 183.200
Action required: 705 - Other - as specified
Due 14 March 2023
Resolved 9 March 2023
Resolution: The operator installed a UL 489 breaker as primary overcurrent protection on the 8 AWG conductor. The breaker is rated for the current carrying capacity of the conductor and is rated as a 50 amp DC breaker.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 May 2022 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. Identified fuel valves are mounted to the railing of the vessel and not closest to the fuel tank supply. The valves were originally located on the tank but were moved. 46CFR 182.455(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2022
Resolved 20 May 2022
Resolution: Both port and stbd emergency fuel shut-off valves were relocated valves back to the tank - all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 May 2022 Resolved
Beckets. Each ring buoy shall be fitted with four beckets located at equidistant points about the body of the buoy. The beckets shall be passed around the body of the buoy with the free ends to the outside, and shall be securely cemented to the buoy with a suitable waterproof adhesive which is compatible with the unicellular plastic used in the buoy body. The ends of the beckets shall be turned under at least 1 inch, one end to go around the grab line, and the other to be laid flat against the first end. The beckets shall then be stitched to the grab line with not less than five hand stitches made with two parts of thread or machined stitched with not less than three stitches per inch. The ring buoys beckets (04) were fraying apart. Replace beckets or replace entire ring buoy. 46 CFR 160.050-4(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2022
Resolved 20 May 2022
Resolution: A new ring buoy was installed - all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 May 2022 Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. The ring buoy markings for the vessel's name was missing multiple letters and the other letters were coming off making the name not legible. 46 CFR 185.604(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2022
Resolved 20 May 2022
Resolution: A new ring buoy was installed with proper labeling of vessel name - all sat
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 May 2022 Resolved
Each ring life buoy with a floating water light must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the water light around the body of the ring life buoy. The lanyard was not secured around the body of the ring buoy. Captain corrected on the spot by attaching around the body of the ring buoy. 46 CFR 180.70(d)(2)
Action required: 10 - Deficiency Rectified
Resolved 19 May 2022
Resolution: Captain corrected on the spot by attaching lanyard for water light around body of ring buoy - all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 May 2022 Resolved
Each floating water light installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip. The clip must have a strength of at least 22.7 kilograms (50 pounds), and allow the water light to be quickly disconnected from the ring life buoy. The corrosion resistant clip was seized were it was hard hard to open and close. Repair or replace corrosion resistant clip. 46 CFR 180.70(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2022
Resolved 20 May 2022
Resolution: A new corrosion clip was installed - all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 May 2022 Resolved
(e) Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 (incorporated by reference; see 46 CFR 175.600) or be specifically approved by the Commandant. (e)(3)(i)Flexible hose may only be used at a pressure not to exceed the manufacturer's rating and must have a high resistance to saltwater, petroleum oils, and vibration. Nonmetallic fuel hose supply from fuel tank to emergency shut-off valve was cracked and dry-rotted. 46 CFR 182.720(e)(3)(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2022
Resolved 20 May 2022
Resolution: New fuel hose was installed on both port/stbd fuel supply lines from tanks to racor filters and engines - all sat.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 19 May 2022 Resolved
(a) Each EPIRB, other than an EPIRB in an inflatable life raft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. (c) The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. EPIRB inspection log with required monthly tests completed was not on the vessel. Captain stated the test log was in the office. Completed functional test of EPIRB, asked the Captain to log accordingly in current test log and provide proof. 46 CFR 185.728(a)(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2022
Resolved 20 May 2022
Resolution: Received proof of EPIRB log being kept - all sat.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 19 May 2022 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. The disposable hydrostatic release unit did not have expiration date of two years after the date which the unit was installed. Captain marked the date accordingly on the hydrostatic release unit. 46 CFR 185.740(b)
Action required: 10 - Deficiency Rectified
Resolved 19 May 2022
Resolution: Captain marked the date accordingly on the hydrostatic release unit of the installation in 2021 - all sat.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 19 May 2022 Resolved
The items contained in first-aid kit shall be as listed in Table 160.041-4(b). A total of 100 aspirin tablets are required. First aid kit only had 36 aspirin tablets. 46 CFR 160.041-4(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2022
Resolved 20 May 2022
Resolution: Additional 120 count bottle of asprin was added to first aid kit - all sat.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 19 May 2022 Resolved
Except as otherwise provided in this section every vessel must be fitted with a suitable magnetic compass designed for marine use, to be mounted at the primary operating station. Magnetic compass had been removed and Captain had been using compass on cellphone. Captain is reinstalling magnetic compass. 46 CFR 184.402(a)
Action required: 10 - Deficiency Rectified
Resolved 19 May 2022
Resolution: The magnetic compass was reinstalled at the helm - all sat.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 19 May 2022 Resolved
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident as defined in § 4.03-2 of subchapter A of this chapter shall comply with the requirements of 4.06. Alcohol swabs were expired. 46 CFR 185.212
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2022
Resolved 20 May 2022
Resolution: Captain provided receipt of new alcohol swabs ordered.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 April 2019 Resolved
The vessel must be equipped with child size lifejackets equal to at least 10 percent of the maximum number of passengers permitted. All 5 child size lifejackets had unserviceable retro-reflective tape. Replace. Vessel is limited to daylight operations only. - 46CFR176.808(e)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2019
Resolved 25 April 2019
Resolution: Vessel owner replaced child size lifejackets with approved type.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 April 2019 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. The FCC licensed technician must use the latest FCC Information Bulletin, How to Conduct an Inspection of a Small Passenger Vessel. If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate. Communications Act Radiotelephony Certificates may be obtained from the Commission’s National Call Center—(888) 225–5322—or from its forms contractor. Vessel owner installed new radio installation that has not been inspected by an FCC-licensed technician. Inspect radio and provide valid Radiotelephony Certificate to USCG. - 47CFR80.903
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2019
Resolved 26 April 2019
Resolution: Vessel owner submitted valid certificate.
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 16 April 2019 Resolved
The owner or operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crewmember is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard required by § 185.510 of this part. Crew training shall be logged for review by the Coast Guard upon request. The training entry shall include the following information: Date of the training and general description of the training topics. Training and drills were not logged. Provide updated training record to USCG. - 46CFR185.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2019
Resolved 26 April 2019
Resolution: Owner submitted training/drill logs.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 April 2019 Resolved
Each EPIRB must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. The EPIRB test shall be logged or otherwise documented, as applicable. Owner had no record of monthly EPIRB testing. Provide record to USCG. - 46CFR185.728(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2019
Resolved 26 April 2019
Resolution: Owner submitted EPIRB testing logs.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 7 January 2019 Resolved
A vessel shall be inspected for compliance with the standards required by this subchapter. Two areas of rot discovered in plywood deck port side midships with a hole in the deck. One area of rot discovered in plywood deck starboard side aft. Grind back and make permanent repairs. - 46CFR176.25-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2019
Resolved 23 January 2019
Resolution: Vessel owner affected permanent repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 January 2019 Resolved
A submersible electric bilge pump may be used as a power bilge pump provided that a positive shutoff valve is installed at the hull penetration. All bilge discharge positive shutoff valves have flex hose between the hull and the valve. Remove flex hose and install valves at the hull penetrations. - 46CFR185.520(e)(7)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2019
Resolved 23 January 2019
Resolution: Vessel owner installed valves at the bulkhead penetrations, tested sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 January 2019 Resolved
Wiring joints and spices shall be mechanically secure and made in junction boxes. Junction box covers missing on port and starboard side midship junction boxes below deck. Replace. - 46CFR183.05-50(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2019
Resolved 23 January 2019
Resolution: Vessel owner provided covers for junction boxes.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 January 2019 Resolved
Light and power conductors for interior wiring shall be insulated. Multiple dead end wires discovered throughout vessel. Cap or remove. - 46CFR183.05-45(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2019
Resolved 23 January 2019
Resolution: Dead end wires were removed throughout the vessel to the satisfaction of the attending marine inspector.
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 7 January 2019 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. Vessel owner replaced embarkation "three step box" with a hinged and deck mounted aluminum embarkation ladder with railing. Update Beaching Plan dated 01/11/2017 to include changes and submit to OCMI for review. - 46CFR176.700(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2019
Resolved 23 January 2019
Resolution: Vessel owner revised beaching plan dated 01/11/2017. Revisions were uploaded into MISLE.
Engineering › Fuel Oil Service System › Valve
Issued 20 April 2017 Resolved
Re-label fuel shut-off valves in clear, legible, one inch high letters. 46CFR185.608
Due 4 May 2017
Resolved 28 April 2017
Resolution: Fuel shut off valves labeled correctly.
Navigation › Piloting/Steering › Marine Charts
Issued 20 April 2017 Resolved
Provide up-to-date navigation chart for area of operation. 46CFR184.420
Due 4 May 2017
Resolved 28 April 2017
Resolution: New and up to date chart provided.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 April 2017 Resolved
Provide ammonia inhalants for vessel's first aid kit. 46CFR160.041
Due 4 May 2017
Resolved 28 April 2017
Resolution: Ammonia inhalants provided.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 January 2016 Resolved
Properly connect exposed wires to PA system IAW 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 3 February 2016
Resolved 2 February 2016
Resolution: Owner removed wires.
Construction/Loadline › Hull › Weld
Issued 15 January 2016 Resolved
Repair cracked weld on fwd most port stanchion for canvas IAW 46 CFR 177.900.
Action required: 705 - Other - as specified
Due 3 February 2016
Resolved 2 February 2016
Resolution: Owner welded crack.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 January 2016 Resolved
Replace port navigation light IAW 46 CFR 183.420.
Action required: 705 - Other - as specified
Due 3 February 2016
Resolved 2 February 2016
Resolution: Owner replaced the nav light
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 27 February 2012 Resolved
Provide current alcohol test strips. 46 CFR 4.06-15
Due 28 March 2012
Resolved 23 May 2012
Resolution: E-mailed pictures of new alcohol test strips.
Stability › Watertight Integrity › General
Issued 27 February 2012 Resolved
Plug piping holes in head. 46 CFR 179.320
Due 28 March 2012
Resolved 23 May 2012
Resolution: E-mailed pictures of plugged holes.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 27 February 2012 Resolved
Install fuel tank vent screen. 46 CFR 182.15-35
Due 28 March 2012
Resolved 1 June 2012
Resolution: E-mailed picture of vent properly installed.
Communications › Alarms/Indicators › Bilge Alarm
Issued 27 February 2012 Resolved
Secure/mount bilge high level alarm switch. 46 CFR 182.530
Condition: Improper Installation
Due 28 March 2012
Resolved 23 May 2012
Resolution: E-mailed picture of properly mounted bilge high level alarm switch.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 3 February 2011 Resolved
Properly display EAP hotline number as per 46 CFR 16.401
Due 17 February 2011
Resolved 17 February 2011
Resolution: EAP hotline number properly displayed.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 3 February 2011 Resolved
Properly train crewmembers before assuming safety sensitive positions as per 46 CFR 16.401.
Due 17 February 2011
Resolved 17 February 2011
Resolution: Crewmembers properly trained.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 3 February 2011 Resolved
Supervisor must receive 1 hour EAP training as per 46 CFR 16.401
Due 17 February 2011
Resolved 17 February 2011
Resolution: EAP training received
Documentation › Markings/Placards › Warning Signs
Issued 7 May 2009 Resolved
Provide Emergency Broadcast Placard at the operating station.
Action required: 705 - Other - as specified
Due 7 June 2009
Resolved 15 May 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 May 2009 Resolved
Provide aspirin and eye wash for first aide kit.
Action required: 705 - Other - as specified
Due 7 June 2009
Resolved 15 May 2009
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 7 May 2009 Resolved
Provide/Renew/Replace high water level alarm and relocate to no more than 6 inch from bottom of bilge.
Action required: 705 - Other - as specified
Due 21 May 2009
Resolved 15 May 2009
Documentation › Markings/Placards › Garbage Placard
Issued 4 May 2009 Resolved
Renew/replace MARPOL/GARBAGE placard.
Action required: 705 - Other - as specified
Due 7 June 2009
Resolved 15 May 2009
Documentation › Markings/Placards › Oil Discharge Placard
Issued 4 May 2009 Resolved
Provide Oil Pollution Placard.
Action required: 705 - Other - as specified
Due 7 June 2009
Resolved 15 May 2009
Engineering › Fuel Oil Service System › Hose
Issued 13 April 2007 Resolved
REPLACE SPRING TENSION TYPE HOSE CLAMPS ON ALL FUEL CONNECTIONS & DOUBLE CLAMP AS NEEDED.
Condition: Improper Installation
Due 14 April 2007
Resolved 18 April 2007
Resolution: HOSE CLAMPS WERE REPLACE.
Navigation › Piloting/Steering › Magnetic Compass
Issued 13 April 2007 Resolved
REPAIR/REPLACE COMPASS LIGHT.
Condition: Unknown
Due 18 April 2007
Resolved 18 April 2007
Resolution: THE COMPASS LIGHT WAS REPAIRED.
Engineering › Bilge Water Management System › Interface Detector
Issued 13 April 2007 Resolved
REPLACE VISUAL HIGH BILGE ALARM INDICATOR ON CONSOLE.
Condition: Improper/Lack of Maintenance
Due 18 April 2007
Resolved 18 April 2007
Resolution: A NEW VISUAL INDICATOR WAS PURCHASED AND INSTALLED.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 April 2007 Resolved
PROVIDE A COMPLETE CG APPROVED FIRST AID KIT.
Due 18 April 2007
Resolved 18 April 2007
Resolution: THE FIRST AID KIT WAS REPLENISHED WITH UP TO DATE ITEMS.
Lifesaving › Lifebuoys › Serviceable
Issued 13 April 2007 Resolved
REPLACE RING LIFEBUOY, REMARK WITH VESSELS NAME & REATTACH LIFELINE.
Condition: Damaged By Earlier Event
Due 18 April 2007
Resolved 18 April 2007
Resolution: A NEW LIFEBUOY WAS PURCHASED, MARKED AND LINE ATTACHED.
Documentation › Certificates/Documents › FCC SSL
Issued 3 March 2006 Resolved
Provide FCC Satety Certificate and FCC Station License showing the proper call sign. CG records show a call sign of "WAF 7090", but his certificates are missing the call sign. POC will contact inspector for FCC and have new cert's issued.
Condition: Unknown
Due 17 March 2006
Resolved 6 March 2006
Resolution: RCVD FAX COPY OF FCC CERTS W/NEW CALL SIGN.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 8 March 2005 Resolved
CONDUCT ANNUAL SERVICE OF PORTABLE FIRE EXTINGUISHERS IAW NFPA 10.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2005
Resolution: FAX DOCUMENTATION.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 8 March 2005 Resolved
PROVIDE EMERGENCY INSTRUCTIONS IAW 46 CFR 185.510/512.
Due 8 April 2005
Resolved 5 April 2005
Resolution: FAX
Engineering › Fuel Oil Service System › Piping
Issued 8 March 2004 Resolved
Replace fuel oil lines as needed.
Condition: Improper/Lack of Maintenance
Due 15 March 2004
Resolved 8 March 2004
Navigation › Piloting/Steering
Issued 8 March 2004 Resolved
Provide charts and nautical publications IAW 46CFR184.420. LEGACY COMPONENT DESC: Nuatical publications
Condition: Improper/Lack of Maintenance
Due 15 March 2004
Resolved 16 March 2004
Resolution: REEDS ALMAMAC.
Accommodation/Occupational Safety › Medical/First Aid
Issued 8 March 2004 Resolved
Update first-aid kit. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Due 8 April 2004
Resolved 16 March 2004
Resolution: SAT.
Personnel › Certificates/Documents/Licenses
Issued 8 March 2004 Resolved
Provide a copy of masters licenses. LEGACY COMPONENT DESC: License, Master
Condition: Unknown
Due 15 March 2004
Resolved 8 March 2004
Lifesaving › Lifejacket/PFD (General)
Issued 8 March 2004 Resolved
Label FWD life preserver container with the amount and kind. LEGACY COMPONENT DESC: Storage
Condition: Improper/Lack of Maintenance
Due 15 March 2004
Resolved 16 March 2004
Resolution: SAT.
Lifesaving › Hand Flares
Issued 8 March 2004 Resolved
Provide a watertight container for flares. Flares are in a orange container without the rubber o-ring. LEGACY COMPONENT DESC: Storage
Condition: Improper/Lack of Maintenance
Due 15 March 2004
Resolved 16 March 2004
Resolution: REPLACED CONTAINER.
Lifesaving › Buoyant Apparatus
Issued 5 November 2002 Resolved
TO MAINTAIN AUTHORITY TO OPERATE ON A LCW NMT 3 MILE FROM SHORE ROUTE; COMPLY WITH 46 CFR 180.205(e), BY EITHER INSTALLING AN FCC TYPE ACCEPTED CATEGORY I 406 MHz EPIRB, OR PROVIDE 50% LIFE FLOAT CAPACITY FOR TOTAL PERSONS, OR PROVIDE CG MARINE SAFETY CENTER ACCEPTANCE OF CATAMARAN SUBDIVISON. LEGACY COMPONENT DESC: EPIRB, LIFEFLOAT, OR SUBDIVISION
Due 5 December 2002
Resolved 17 January 2003
Resolution: Rcv''d fax from owner for purchase and receipt of EPIRB - cleared requirement.
Operations/Management › Drills/Instruction
Issued 11 June 2002 Resolved
INITIATE CREW TRAINING LOGS.
Condition: Placed in Improper Service
Due 11 July 2002
Resolved 12 June 2002
Resolution: FAXED.
Documentation › Certificates/Documents › FCC SSL
Issued 11 June 2002 Resolved
PROVIDE FCC RADIOTELEPHONE SAFETY CERTIFICATE.
Condition: Improper Installation
Due 11 July 2002
Resolved 12 June 2002
Resolution: FAXED.
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 11 June 2002 Resolved
PROVIDE UPDATED LIFESAVING/CPR CERTIFICATES.
Due 11 July 2002
Resolved 12 July 2002
Resolution: FAXED.
Engineering › Gasoline Engine (auxiliary) › Backfire Flame Control
Issued 11 June 2002 Resolved
INSTALL FLAME SCREEN ON FUEL TANK VENT.
Condition: Improper/Lack of Maintenance
Due 12 June 2002
Resolved 12 June 2002
Resolution: FAXED RECEIPT.
Engineering › Bilge Water Management System › Pump
Issued 11 June 2002 Resolved
REPAIR STBD MIDSHIP BILGE PUMP.
Due 12 June 2002
Resolved 12 June 2002
Resolution: FOUND TO BE OPERATIONAL. ENERGIZED WRONG SWITCH.
Personnel › Certificates/Documents/Licenses
Issued 11 June 2002 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 7 July 2002
Resolved 9 July 2002
Resolution: FAXED COMPLETION CERTIFICATE #158304.
Engineering
Issued 8 March 2001 Resolved
FUEL SHUTOFF VALVE ON STARBOARD FUEL TANK MISSING.
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Documentation
Issued 8 March 2001 Resolved
FCC SAFETY CERTIFICATE EXPIRED.
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Lifesaving
Issued 8 March 2001 Resolved
LINE AROUND RING LIFEBUOY ROTTED.
Condition: Unknown
Due 8 March 2001
Resolved 20 March 2001
Lifesaving
Issued 12 April 1999 Resolved
CONDUCT MOB/FIRE DRILLS.
Condition: Unknown
Due 30 August 1999
Resolved 30 August 1999
Documentation
Issued 12 April 1999 Resolved
PROVIDE COPY OF MIS REPORT.
Condition: Unknown
Due 30 August 1999
Resolved 30 August 1999
Accommodation/Occupational Safety
Issued 9 March 1998 Resolved
REPAIR/REPLACE BOTTOM LIFELINE CLIP IN PORTSIDE GATE
Condition: Unknown
Due 21 May 1998
Resolved 21 May 1998
Documentation
Issued 9 March 1998 Resolved
PROVIDE PROOF OF CONSORTIUM ENROLLMENT
Condition: Unknown
Due 21 May 1998
Resolved 21 May 1998
Fire Fighting
Issued 9 March 1998 Resolved
ATTACH ADEQUATE LANYARDS TO FIRE BUCKETS
Condition: Unknown
Due 21 May 1998
Resolved 21 May 1998
Documentation
Issued 1 February 1995 Resolved
Provide Radiotelephony Certificate.
Condition: Unknown
Due 1 March 1995
Resolved 1 March 1995
Fire Fighting
Issued 4 February 1992 Resolved
VESSEL NOT IN COMPLIANCE WITH 46 CFR 181.10.1, NO SATISFACTORY FIRE PUMP ONBOARD VESSEL. PRIOR TO COMMERICAL OR PASSENGER OPERATION OF VESSEL PROVIDE ONE ADDITIONAL B-II FIRE EXTINGUISHER, TO THE SATISFACTION OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 4 February 1992
Resolved 4 February 1992

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.