THE FRIKI TIKI OF GLOUCESTER

THE FRIKI TIKI OF GLOUCESTER is a 1989 passenger vessel (inspected). The Coast Guard has recorded 48 inspections since 1989, most recently in May 2025, along with 32 deficiencies and 2 casualty investigations between 2007 and 2009.

Records from 1989 to 2025. Most recent: inspection, 22 May 2025.

Built
1989
Last inspected
22 May 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDM3157
330839
Flag
UNITED STATES
368194710
Maury page id
psix-330839

Inspections, by type

…with no type recorded7
Years with a record 27 calendar years (1989–2025)
The 48 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)36.0 ft × 11.4 ft × 4.1 ft
Registered tonnagegross 11 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBENTZ BOAT · LEWISTON, ID, UNITED STATES · built 1989
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portGLOUCESTER, MA
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 24 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11 - Simplified, Gross Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDM3157MMSI 368194710 · active · compulsorily equipped · granted 24 April 2021, expires 24 April 2031
WDD7044MMSI 367181190 · expired · compulsorily equipped · granted 19 April 2007, cancelled 24 June 2017
WCZ8600MMSI 366783360 · expired · compulsorily equipped · granted 5 June 2000, cancelled 7 August 2010
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 48

22 May 2025 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8137637
22 April 2024 COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7891562
2 April 2024 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7888825
28 September 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7567897
6 May 2022 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7428612
28 September 2020 Initial Certification · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7070128
24 July 2020 Simplified Stability Test · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7023247
30 April 2019 Examination of Repairs · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6673167
10 April 2018 Hull Examination · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6388971
22 July 2009 Examination of Repairs · Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3542656
20 July 2009 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3540236
18 July 2009 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3541572
28 April 2008 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3194812
21 April 2008 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3188743
24 January 2008 Deficiency Check · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3135347
3 July 2007 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3022222
18 April 2007 Re-Inspection · Inclining Experiment
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2909968
24 July 2006 Re-Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2723010
15 May 2006 Hull Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2647732
13 May 2005 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2356567
22 June 2004 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2106534
27 January 2004 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1993668
18 June 2003 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1820855
3 June 2002 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1626579
11 January 2002 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1477929
14 May 2001 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1064997
20 March 2001 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1064554
22 February 2001 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1058104
22 August 2000 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 821278
13 July 2000 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1052006
25 May 2000 COI Inspection · Hull Examination · Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1379086
1 March 2000 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1420270
20 April 1999 Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 791461
16 April 1998 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 789674
28 May 1997 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1118239
7 May 1996 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 873515
24 April 1995 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1412792
23 May 1994 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1024576
23 May 1994 Hull Examination · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1410978
13 July 1993 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1155346
27 April 1993 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1410813
11 May 1992 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 946652
2 May 1991 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1228875
15 May 1990 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 907641
10 January 1990 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1218940
30 October 1989 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 896351
1 August 1989 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1194242
6 May 1989 Hull Examination · Initial Certification · Plan Review "T" Boat
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1277816

Deficiency record · 32

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 May 2025 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required by table 1 to § 181.500(b) and other provisions of this section. Vessel had 01 fire extinguisher under charged out of their 03 required extinguishers.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 5 June 2025
Resolution: Objective evidence in the form of photograph has been provided for fire extinguisher.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 May 2025 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessel's life ring had deteriorated grab lines.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 5 June 2025
Resolution: Objective evidence in the form of photograph has been provided for the life ring bouy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 May 2025 Resolved
Each battery used in an item of lifesaving equipment, except inflatable survival craft equipment, must be replaced during the annual inspection if the expiration date of the battery has passed. The expiration date of the battery may be marked on the battery or the owner or managing operator may have a record of the expiration date from the manufacturer of a battery marked with a serial number. Vessel's battery was expired on the life ring's water light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 5 June 2025
Resolution: Objective evidence in the form of photograph has been provided for the battery.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 May 2025 Resolved
Lakes, bays, and sounds, and rivers routes. A vessel on a lakes, bays, and sounds, or rivers route must carry:(1) Three hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant; and(2) Three hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. Vessel had 04 out of the required 06 distress flares.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 5 June 2025
Resolution: Objective evidence in the form of photograph has been provided for the handflares.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 May 2025 Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Vessel's waste receptacles were plastic and not made of noncombustible material.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 5 June 2025
Resolution: Objective evidence in the form of photograph has been provided for trash can.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 May 2025 Resolved
Portable watertight containers for distress flares and smoke signals shall be of a bright color, and containers shall be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high: “DISTRESS SIGNALS”. Vessel's distress signal container was not labeled.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 5 June 2025
Resolution: Objective evidence in the form of photograph has been provided for distress signal case.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 May 2025 Resolved
The Certificate of Inspection and any SOLAS Certificates must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely. If posting is impracticable, such as in an open boat, the certificates must be kept on board in a weathertight container readily available for use by the crew and display to passengers and others on request. Vessel's current COI was not posted under glass or suitable transparent material nor weathertight container.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 5 June 2025
Resolution: Objective evidence in the form of photograph has been provided for COI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 May 2025 Resolved
Flexible hose designed for use with hose clamps may be installed with two clamps, at both ends of the hose, which:(1) Do not rely on the spring tension of the clamp for compressive force; and(2) Are installed beyond the bead or flare or over the serrations of the mating spud, pipe, or hose fitting. Vessel was missing a hose clamp on vessel's starboard engines fuel line. Ensure all fuel non metallic flex hoses have clamps on each end of the hose.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 5 June 2025
Resolution: Objective evidence in the form of photograph has been provided for hose clamps.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 April 2024 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. The vessel missed its annual inspection. Vessel must undergo an inspection for certification prior to operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2024
Resolution: Conducted COI inspection and issued new COI.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 5 October 2022 Resolved
The marine employer shall take all practicable steps to have each individual engaged or employed on board the vessel who is directly involved in the incident chemically tested for evidence of drug and alcohol. No current consortium enrollment paperwork onboard, the crew list does not reflect the current crew, missing paperwork showing proof of testing for new hires. Provide documentation showing consortium enrollment with all employees listed, proof of new hire test, proof of any random testing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 November 2022
Resolved 20 October 2022
Resolution: Documentation provided
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 5 October 2022 Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. COD expired 31MAR2022. Provide copy of current COD and place onboard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 November 2022
Resolved 28 November 2022
Resolution: Received Objective Evidence that COD was renewed. Placed copy in Documents tab under deficiency.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 5 October 2022 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date Charts of large enough scale to make safe navigation possible. Scale of sole chart onboard was too large of a scale for safe navigation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2022
Resolved 20 October 2022
Resolution: Appropriate chart provided
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 5 October 2022 Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry Three hand red flare distress signals and Three hand orange smoke distress signals. Vessel had 4 red flare distress signals. Provide proof that 2 more distress signals that meet requirements in the cite are placed onboard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2022
Resolved 20 October 2022
Resolution: Flares onboard
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 October 2022 Resolved
The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection. Vessel was missing the 2-A extinguisher listed on the COI. Place a serviceable 2-A extinguisher onboard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2022
Resolved 20 October 2022
Resolution: Extinguisher onboard
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 October 2022 Resolved
National Fire Protection Association (NFPA 17 incorporated by reference) requires maintenance on portable extinguishers be completed. Provide proof that maintenance was completed in accordance with requirements set forth in NFPA 17.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2022
Resolved 20 October 2022
Resolution: Equipment serviced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 October 2022 Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). Second bilge pump to meet requirements of table 182.520(a) was inoperable. Repair/replace inoperable bilge pump.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 October 2022
Resolved 20 October 2022
Resolution: Bilge pumps operable
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 October 2022 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. High water level alarm inoperable. Repair/replace installed equipment as needed to comply with cite.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 October 2022
Resolved 20 October 2022
Resolution: Alarm operable
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 22 July 2009 Resolved
replace siezed up starboard engine.
Due 22 July 2009
Resolved 21 July 2021
Resolution: Vessel was repowered with outboard engines. Plan was reviewed/approved by MSC and oversight done by [name withheld].
Lifesaving › Lifefloat › Serviceable
Issued 28 April 2008 Resolved
Lifefloat has hole in bouyant flotation ring, make proper repairs to float. 46 CFR 185.702
Action required: 705 - Other - as specified
Due 30 May 2008
Resolved 8 May 2008
Resolution: Float repaired
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 April 2008 Resolved
Port running light not operable. Make proper repairs to nav light. 46 CFR 183.420
Action required: 705 - Other - as specified
Due 2 May 2008
Resolved 8 May 2008
Resolution: Light repaired
Engineering › Bilge Water Management System › Interface Detector
Issued 28 April 2008 Resolved
Provide proper bilge level alarm at helm station for installed electric bilge level alarm and pump in accordance with 46 CFR 182.530 (a) and (c).
Action required: 705 - Other - as specified
Due 30 May 2008
Resolved 8 May 2008
Resolution: Alarm repaired
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 28 April 2008 Resolved
Emergency broadcast placard missing. Provide proper placard at helm station. 46 CFR 184.506
Action required: 705 - Other - as specified
Due 30 May 2008
Resolved 8 May 2008
Resolution: Placard installed
Fire Fighting › Structural - A Class Divisions › Windows
Issued 28 April 2008 Resolved
Front windscreen windows, provide documentation attesting to the window "glass" capabilities to meet the requirements of 46 CFR 177.1010 and 177.1020.
Action required: 705 - Other - as specified
Due 30 May 2008
Resolved 13 May 2008
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 24 July 2006 Resolved
Replace waterlight on BA.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 July 2006
Resolved 28 July 2006
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 July 2006 Resolved
Replace waterlight on lifering.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 July 2006
Resolved 28 July 2006
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 24 July 2006 Resolved
Replace 5 adult Type I PFD's. Vessel passenger count reduced from 51 passengers to 46 until replaced onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 July 2006
Resolved 28 July 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 24 July 2006 Resolved
Weigh and service portable fire extinguisher. Type B-II
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 July 2006
Resolved 28 July 2006
Navigation
Issued 13 July 2000 Resolved
SUBMIT OPERATIONS MANUAL TO MSO PORTLAND ME
Condition: Unknown
Due 13 July 2000
Resolved 13 July 2000
Construction/Loadline
Issued 25 May 2000 Resolved
WELD CRACKS IN FORWARD BILGE AREA OF VESSEL ON DECK SUPPORTS AND GUSSETS ASPOINTED OUT BY THE MARINE INSPECTOR.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Documentation
Issued 25 May 2000 Resolved
POST STABILITY LETTER WHEN RECEIVED FROM COAST GUARD MARINE SAFETY OFFICE.
Condition: Unknown
Due 25 May 2000
Resolved 25 May 2000
Documentation
Issued 27 April 1993 Resolved
PROVIDE PROOF OF DOCUMENTATION
Condition: Unknown
Due 27 April 1993
Resolved 27 April 1993
Construction/Loadline
Issued 6 May 1989 Resolved
PROVIDE ADDITIONAL SIDE TRANSVERSE FRAMING TO OBTAIN FRAME SPACING OF A MINIMUM OF THREE FEET BETWEEN CENTERS.
Condition: Unknown
Due 6 May 1989
Resolved 6 May 1989

Casualty record · 2

3 July 2007Routine · role: Involved in a Marine Casualty · activity 3022222
18 July 2009Routine · role: Involved in a Marine Casualty · activity 3541572
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

CULEBRA (2007–2009). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.