VIII is a 1989 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2016, most recently in October 2025, along with 12 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 28 October 2025.

Built
1989
Last inspected
28 October 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDJ 5764
331000
Flag
UNITED STATES
Maury page id
psix-331000

Inspections, by type

Years with a record 10 calendar years (2016–2025)
The 16 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)30.2 ft × 15.9 ft × 4.4 ft
Registered tonnagegross 14 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFREY W STICKLER · COSTA MESA, CA, UNITED STATES · built 1989
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 August 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Simplified, Gross Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 16

28 October 2025 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8239676
27 March 2025 Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8099861
28 October 2024 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8026194
9 November 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7818676
30 March 2023 Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7651820
14 December 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7605486
29 October 2021 Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7337020
29 April 2021 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7189789
12 August 2020 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7032207
25 October 2019 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6841822
20 August 2019 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6788519
17 April 2019 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6664169
19 July 2018 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6485319
19 July 2017 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6216181
9 May 2017 COI Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6144057
11 May 2016 COI Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5797027

Deficiency record · 12

11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 28 October 2024 Resolved
Except for a storage battery used in a rescue boat, each battery without an expiration date indicated on it or for which the owner or managing operator does not have a record of the expiration date, used in an item of lifesaving equipment, must be replaced during the annual inspection. The water light battery for the ring life buoy did not have an expiration date marked on the battery. Renew water light battery to the satisfaction of the attending marine inspector. 46 CFR 185.726(e)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 November 2024
Resolved 28 October 2024
Resolution: Vessel rep provided photograph via email showing the installation of a new battery with a marked date of install on the battery.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 November 2023 Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Shaft seal was found with considerable leak. 46CFR182.05-1(a) - 16 c.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 November 2023
Resolved 28 November 2023
Resolution: Shaft packing tightened, found with no leaks, all sat.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 9 November 2023 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Pain and antiseptic medication found expired in first aid kits onboard. Replace required medication to have equivalent contents. 46 CFR 184.710 - 16 c.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 November 2023
Resolved 28 November 2023
Resolution: Vsl replaced pain medication and topical antiseptic. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 December 2022 Resolved
Individual power pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation. Bilge pump switch did not work in Auto, Off, or Manual, but bilge system ran continuously.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 January 2023
Resolution: Verified the correct operation of the pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 December 2022 Resolved
A submersible electric bilge pump may be used as a power bilge pump on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that the pump is permanently mounted. The forepeak and laz bilge pumps were found loose out of their strainers.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 December 2022
Resolved 6 January 2023
Resolution: Verified the pumps were correctly mounted.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 29 October 2021 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date charts of large enough scale to make safe navigation possible. The charts on the vessel were last updated in 2016. Vessel to provide current charts for the areas to be navigated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2021
Resolved 17 November 2021
Resolution: Verified current charts were onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 29 October 2021 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. The vessel did not have any portable lights onboard. Vessel to provide adequate portable lights.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2021
Resolved 17 November 2021
Resolution: Verified portable lights were onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 October 2021 Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 3 feet, but not more than 6 feet, securing the waterlight around the body of the ring life buoy. The line for the waterlight was less than 3 feet. Vessel to replace line to appropriate length.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2021
Resolved 17 November 2021
Resolution: Verified adequate line was installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 October 2021 Resolved
Each floating waterlight must be attached to the lanyard with the corrosion resistant clip and allow the waterlight to be quickly disconnected from the ring lifebuoy. The clip was too small and did not allow for the quick connect/disconnect. Vessel to replace clip with one of adequate size.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2021
Resolved 17 November 2021
Resolution: Verified clip of adequate size was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 August 2019 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. There is no visual indicator at the operating station.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2019
Resolved 10 September 2019
Resolution: Visual Indicator was installed.
Communications › Radio Communications › EPIRB
Issued 11 May 2016 Resolved
Hydrostatic release unit for EPIRB had wrong expiry scratch off date (date scratched was installation date).
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 11 May 2016
Resolution: Owner provided proof of installation date to be DEC 2015. ICON will provide new hydrostatic release unit with correct expiry scratch off date.
Lifesaving › Buoyant Apparatus › Float Free
Issued 11 May 2016 Resolved
Discovered buoyant apparatus to not be installed in a float free arrangement.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 11 May 2016
Resolution: Operator properly installed buoyant apparatus' in a float free arrangement.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.