MAURY USCG vessel records Sign in
← All vessels

OPTIMUS

OPTIMUS is a 1985 tank ship. The Coast Guard has recorded 26 inspections since 1989, most recently in September 2023, along with 18 deficiencies and 5 operational controls.

Records from 1989 to 2023. Most recent: inspection, 13 September 2023.

Built
1985
Last inspected
13 September 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8030192 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
331065
Flag
MARSHALL ISLANDS
—
Maury page id
psix-331065

Inspections, by type

…with no type recorded15
Years with a record 10 calendar years (1989–2023)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it7734 - Dead Weight, Ton
4449 - Convention (Subpart B), Gross Ton
5691 - Regulatory (Subpart C or D), Gross Ton
3651 - Convention (Subpart B), Net Ton
2929 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 26

13 September 2023 Deficiency Check
Physical examination · Liquefied Gas Carrier National Center of Expertise · Activity 7790937
12 February 2008 MARPOL Annex II Examination · COC-GAS Annual · MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3146028
11 February 2008 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3145482
13 June 2007 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2961485
11 May 2007 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2927910
11 May 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2928066
10 May 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2927095
24 October 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2807194
5 March 2006 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2596191
14 December 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2554313
13 December 2005 COC-GAS Annual · ISPS II Exam · Ballast Water Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2550857
12 December 2005 Type not recorded
No type recorded · Vessel Traffic Service Houston-Galveston · USCG Heartland District (CGD-H) · Activity 2550430
17 December 2004 Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2261539
15 December 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2259690
1 September 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 382457
1 September 1995 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 872139
1 September 1995 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1187252
28 August 1992 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 491659
18 May 1992 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1254760
4 December 1990 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 459436
25 July 1990 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 338432
25 July 1990 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1243014
26 February 1990 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 335554
21 February 1990 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 490257
28 June 1989 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 331122
28 June 1989 Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1199797

Deficiency record · 18

Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 12 February 2008 Resolved
Emergency shut down, warning light not working. Received class report that this deficiency should be rectified by 14APR08.
Action required: 705 - Other - as specified
Due 14 April 2008
Resolved 5 March 2012
Resolution: Open deficiencies on this decommissioned and scrapped vessel were administratively closed based on the objective evidence provided in Bureau Veritas’ email dated August 16, 2023. The email has been uploaded into the vessel’s documents.
Deck/Cargo › Cargo Refrigeration › General
Issued 12 February 2008 Resolved
Starboard side vapor suction for condensor is leaking. Adjust and provide class report.
Action required: 705 - Other - as specified
Resolved 13 February 2008
Resolution: Received class report on 13FEB08. The vapour input valve seal gland leaking has been rectified to the satisfaction of class.
Accommodation/Occupational Safety › Ventilation › General
Issued 12 February 2008 Resolved
Ventilation system in motor room is not working properly. Fix to the satisfaction of class. Received class report that this deficiency should be rectified by 14APR08.
Action required: 705 - Other - as specified
Due 14 April 2008
Resolved 5 March 2012
Resolution: Open deficiencies on this decommissioned and scrapped vessel were administratively closed based on the objective evidence provided in Bureau Veritas’ email dated August 16, 2023. The email has been uploaded into the vessel’s documents.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder
Issued 12 February 2008 Resolved
Main diesel engine has a broken/inoperable cylinder.
Action required: 705 - Other - as specified
Resolved 13 February 2008
Resolution: Received class report of 13FEB08. The Main Engine Cylinder No. 3 has been repaired using ships spares to the satisfaction of class.
Engineering › Fuel Oil Service System › Piping
Issued 12 February 2008 Resolved
Found pin hole in F/O pipe. Replace damage section of pipe to the satisfaction of class priorto bunkering.
Action required: 703 - Prior to bunkering operations
Resolved 5 March 2012
Resolution: Open deficiencies on this decommissioned and scrapped vessel were administratively closed based on the objective evidence provided in Bureau Veritas’ email dated August 16, 2023. The email has been uploaded into the vessel’s documents.
Fire Fighting › Structural Fire Protection - General › Deckhouse Construction
Issued 17 December 2004 Resolved
MAIN DECK PORT LIGHTS STEEL COVERS NOT PROPERLY FITTED.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2004
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 17 December 2004 Resolved
FIRE CONTROL PLAN IS NOT UPDATED. B-CLASS SUBDIVISION OFFICER AND CREW MESS WAS CONVERTED TO A KITCHENETTE. OFFICE COMPARTMNET ENTERING CREW GALLEY WAS CONVERTED TO A REGULAR CLASS B DIVISION BULKHEAD. ADDRESS THE AREAS WHERE NEW WOODEN BULKHEAD/COMPARTMENT WAS INSTALLED AT EMERGENCY FIREPUMP AND REMOVE WOODEN LIOCKER FROM PAINT LOCKER.
Action required: 705 - Other - as specified
Due 16 January 2005
Resolved 5 March 2006
Resolution: Received documentation from classification society attesting to the updated and approved Fire Control Plan for the vessel Optimus. Deficiency was cleared and removed.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 17 December 2004 Resolved
ICE MAKER IN PASSAGEWAY TO CREW MESS SHOULD BE MOVED
Condition: Improper Installation
Due 16 January 2005
Resolved 13 December 2005
Fire Fighting › Ventilation Systems › Ducts
Issued 17 December 2004 Resolved
VENTILATION PIPE LATCH TO EMERGENCY FIRE PUMP ROOM ENTRANCE NEEDS TO BE REPLACED.
Due 16 January 2005
Resolved 13 December 2005
Fire Fighting › Fire Hydrants › Material
Issued 17 December 2004 Resolved
SEAL ON FORWARD MOST FIRE HYDRANT NEEDS TO BE REPLACED.
Due 16 January 2005
Resolved 13 December 2005
Lifesaving › Lifeboat Equipment › Radar Transponder
Issued 17 December 2004 Resolved
SART TRANSPONDER WAS BY OPENED BY CREW DURING INSPECTION, NEEDS TO BE REPLACED.
Due 16 January 2005
Resolved 13 December 2005
Fire Fighting › Structural - A Class Divisions › Doors
Issued 17 December 2004 Resolved
FIRE SCREEN DOORS NOT PROPERLY LATCHING. REPAIR AND PROVE PROPER OPERATION.
Condition: Improper/Lack of Maintenance
Due 16 January 2005
Resolved 13 December 2005
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 17 December 2004 Resolved
PORT AND STBD LIFEBOAT RUDDERS NOT PROPERLY FITTED. REPAIR AND PROVE PROPER OPERATION.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 18 December 2004
Resolved 18 December 2004
Lifesaving › Lifeboat › Canopy
Issued 17 December 2004 Resolved
PORT AND STBD LIFEBOAT COVERS ARE NOT HIGHLY VISIBLE COLOR AS PER SOLAS. PROVIDE PROPER LIFEBOAT COVER.
Due 16 January 2005
Resolved 13 December 2005
Lifesaving › Launching Appliances › Winch Brake
Issued 17 December 2004 Resolved
PORT AND STBD LIFEBOAT WINCH BRAKES ARE IMPROPERLY ADJUSTED. PROPERLY ADJUST AND PROVE PROPER OPERATION.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 18 December 2004
Resolved 17 December 2004
Deck/Cargo
Issued 1 September 1995 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 5 September 1995
Resolved 8 September 1995
Deck/Cargo
Issued 1 September 1995 Resolved
REPAIR HOLED DRAIN LINE ON INERT GAS/DRY AIR SYSTEM CONDENSER UNIT. MAKE TEMPORARY REPAIRS PRIOR TO USING SYSTEM.
Condition: Unknown
Due 1 September 1995
Resolved 8 September 1995
Deck/Cargo
Issued 1 September 1995 Resolved
PROVIDE SPAN GAS OF KNOWN CONCENTRATION FORE CALIBRATING INERT GAS SYSTEM, REPAIR & DEMONSTRATE OPERATION OF PHOTO EYE SENSOR FOR FLAME OUT ON GENERATOR. CALIBRATE & DEMONSTRATE PROPERT OPERATION OF SYSTEM, ALARMS, & SHUTDOWN TO SATISFACTION OF CLASS. PROVIDE COAST GUARD WITH CLASS REPORT.
Condition: Unknown
Due 5 September 1995
Resolved 8 September 1995

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.