← All vessels
OPTIMUS
OPTIMUS is a 1985 tank ship. The Coast Guard has recorded 26 inspections since 1989, most recently in September 2023, along with 18 deficiencies and 5 operational controls.
Records from 1989 to 2023. Most recent: inspection, 13 September 2023.
- Built
- 1985
- Last inspected
- 13 September 2023
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 18 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8030192 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7G03
331065
Flag
MARSHALL ISLANDS
—
Maury page id
psix-331065
Inspections, by type
…with no type recorded15
Years with a record
10 calendar years (1989–2023)
The 26 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it7734 - Dead Weight, Ton
4449 - Convention (Subpart B), Gross Ton
5691 - Regulatory (Subpart C or D), Gross Ton
3651 - Convention (Subpart B), Net Ton
2929 - Regulatory (Subpart C or D), Net Ton
4449 - Convention (Subpart B), Gross Ton
5691 - Regulatory (Subpart C or D), Gross Ton
3651 - Convention (Subpart B), Net Ton
2929 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 26
13 September 2023
Deficiency Check
Physical examination · Liquefied Gas Carrier National Center of Expertise · Activity 7790937
12 February 2008
MARPOL Annex II Examination · COC-GAS Annual · MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3146028
11 February 2008
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3145482
13 June 2007
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2961485
11 May 2007
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2927910
11 May 2007
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2928066
10 May 2007
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2927095
24 October 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2807194
5 March 2006
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2596191
14 December 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2554313
13 December 2005
COC-GAS Annual · ISPS II Exam · Ballast Water Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2550857
12 December 2005
Type not recorded
No type recorded · Vessel Traffic Service Houston-Galveston · USCG Heartland District (CGD-H) · Activity 2550430
17 December 2004
Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2261539
15 December 2004
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2259690
1 September 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 382457
1 September 1995
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 872139
1 September 1995
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1187252
28 August 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 491659
18 May 1992
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1254760
4 December 1990
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 459436
25 July 1990
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 338432
25 July 1990
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1243014
26 February 1990
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 335554
21 February 1990
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 490257
28 June 1989
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 331122
28 June 1989
Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1199797
Deficiency record · 18
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 12 February 2008
Resolved
Emergency shut down, warning light not working. Received class report that this deficiency should be rectified by 14APR08.
Deck/Cargo › Cargo Refrigeration › General
Issued 12 February 2008
Resolved
Starboard side vapor suction for condensor is leaking. Adjust and provide class report.
Accommodation/Occupational Safety › Ventilation › General
Issued 12 February 2008
Resolved
Ventilation system in motor room is not working properly. Fix to the satisfaction of class. Received class report that this deficiency should be rectified by 14APR08.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder
Issued 12 February 2008
Resolved
Main diesel engine has a broken/inoperable cylinder.
Engineering › Fuel Oil Service System › Piping
Issued 12 February 2008
Resolved
Found pin hole in F/O pipe. Replace damage section of pipe to the satisfaction of class priorto bunkering.
Fire Fighting › Structural Fire Protection - General › Deckhouse Construction
Issued 17 December 2004
Resolved
MAIN DECK PORT LIGHTS STEEL COVERS NOT PROPERLY FITTED.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 17 December 2004
Resolved
FIRE CONTROL PLAN IS NOT UPDATED. B-CLASS SUBDIVISION OFFICER AND CREW MESS WAS CONVERTED TO A KITCHENETTE. OFFICE COMPARTMNET ENTERING CREW GALLEY WAS CONVERTED TO A REGULAR CLASS B DIVISION BULKHEAD. ADDRESS THE AREAS WHERE NEW WOODEN BULKHEAD/COMPARTMENT WAS INSTALLED AT EMERGENCY FIREPUMP AND REMOVE WOODEN LIOCKER FROM PAINT LOCKER.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 17 December 2004
Resolved
ICE MAKER IN PASSAGEWAY TO CREW MESS SHOULD BE MOVED
Fire Fighting › Ventilation Systems › Ducts
Issued 17 December 2004
Resolved
VENTILATION PIPE LATCH TO EMERGENCY FIRE PUMP ROOM ENTRANCE NEEDS TO BE REPLACED.
Fire Fighting › Fire Hydrants › Material
Issued 17 December 2004
Resolved
SEAL ON FORWARD MOST FIRE HYDRANT NEEDS TO BE REPLACED.
Lifesaving › Lifeboat Equipment › Radar Transponder
Issued 17 December 2004
Resolved
SART TRANSPONDER WAS BY OPENED BY CREW DURING INSPECTION, NEEDS TO BE REPLACED.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 17 December 2004
Resolved
FIRE SCREEN DOORS NOT PROPERLY LATCHING. REPAIR AND PROVE PROPER OPERATION.
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 17 December 2004
Resolved
PORT AND STBD LIFEBOAT RUDDERS NOT PROPERLY FITTED. REPAIR AND PROVE PROPER OPERATION.
Lifesaving › Lifeboat › Canopy
Issued 17 December 2004
Resolved
PORT AND STBD LIFEBOAT COVERS ARE NOT HIGHLY VISIBLE COLOR AS PER SOLAS. PROVIDE PROPER LIFEBOAT COVER.
Lifesaving › Launching Appliances › Winch Brake
Issued 17 December 2004
Resolved
PORT AND STBD LIFEBOAT WINCH BRAKES ARE IMPROPERLY ADJUSTED. PROPERLY ADJUST AND PROVE PROPER OPERATION.
Deck/Cargo
Issued 1 September 1995
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Deck/Cargo
Issued 1 September 1995
Resolved
REPAIR HOLED DRAIN LINE ON INERT GAS/DRY AIR SYSTEM CONDENSER UNIT. MAKE TEMPORARY REPAIRS PRIOR TO USING SYSTEM.
Deck/Cargo
Issued 1 September 1995
Resolved
PROVIDE SPAN GAS OF KNOWN CONCENTRATION FORE CALIBRATING INERT GAS SYSTEM, REPAIR & DEMONSTRATE OPERATION OF PHOTO EYE SENSOR FOR FLAME OUT ON GENERATOR. CALIBRATE & DEMONSTRATE PROPERT OPERATION OF SYSTEM, ALARMS, & SHUTDOWN TO SATISFACTION OF CLASS. PROVIDE COAST GUARD WITH CLASS REPORT.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.