Records from 2016 to 2019. Most recent: inspection, 6 November 2019.
Inspection history · 11
6 November 2019
Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6851047
7 June 2019
Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6706308
15 April 2019
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6663154
5 September 2018
Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6532359
5 April 2018
Damage Survey
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6385513
14 March 2018
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6371510
22 April 2017
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6130101
7 February 2017
Damage Survey
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6083730
8 December 2016
DAPI Audit
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6055022
8 December 2016
DAPI Audit · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6055727
7 November 2016
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6037227
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 7 June 2019
Resolved
Fire hose on lower level has a leak and upstairs hose needs bronze nozzle. Replace lower level hose and purchase a bronze nozzle for the upstairs hose.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 June 2019
Resolved 7 June 2019
Resolution: Replaced hose and noozle
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 June 2019
Resolved
Fuel Shutoff valve for port engine linkage cable is wasted and was held in place with zip ties and wires. Replace linkage cable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 June 2019
Resolved 7 June 2019
Resolution: replaced cable
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 June 2019
Resolved
Vessel is required to have FCC Station License and FCC Safety Safety Radio Cert. Provide Proof of these documents.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2019
Resolved 31 October 2019
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 7 June 2019
Resolved
Provide updated copy of light list for local area.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2019
Resolved 26 June 2019
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 7 June 2019
Resolved
Provide emergency broadcast placard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2019
Resolved 7 June 2019
Resolution: Provided placard
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 7 June 2019
Resolved
Provide Flares for the intended route. 3 red flares and 3 orange flares.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2019
Resolved 26 June 2019
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 7 June 2019
Resolved
Replace 03 lighting fixtures on lower level. Lighting did not have covers.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2019
Resolved 7 June 2019
Resolution: replaced lighting fixtures
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 June 2019
Resolved
Chemical Testing for the crew must be completed. Vessel has no proof of being in a consortium.
Vessel will use crew from another boat until this is complete
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2019
Resolved 26 June 2019
Engineering › Diesel Engine (propulsion-reduction gear) › Piston
Issued 5 April 2018
Resolved
STBD propulsion engine #1 Piston seized. Conduct repairs IAW engine manufacture instructions. No passenger carry until repairs are complete and attest by the attending CG marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2018
Resolution: STBD engine was replaced with in-kind cummings engine. Witnessed satisfactory sea trail.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 March 2018
Resolved
Navigation light must be in serviceable condition and operation as required by 46 CFR 183.420.Repair inoperable stern light.
Due 28 March 2018
Resolved 28 March 2018
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 March 2018
Resolved
deck rail must be in satisfactory condition as originally approved as required by 46 CFR 176.25-5. Repair damaged forward deck rail. No passenger allowed pass the forward main cabin.
Due 28 March 2018
Resolved 31 October 2019
Lifesaving › Lifebuoys › Serviceable
Issued 14 March 2018
Resolved
Ring buoy must be in good and serviceable condition as required by 46 CFR 180.30-1. Replace damaged ring buoy.
Due 28 March 2018
Resolved 28 March 2018
Fire Fighting › Nozzles › Type
Issued 14 March 2018
Resolved
Garden hose nozzle must be of good grade bronze or equivalent materials as required by 46 CFR 181.15-10. Replace wasted hose nozzle.
Due 28 March 2018
Resolved 28 March 2018
Communications › Radio Communications › VHF Radiotelephone
Issued 14 March 2018
Resolved
VHF must have DSC capability programed as required by 47 CFR 80. Install VHF with DSC programed into it.
Due 28 March 2018
Resolved 28 March 2018
Construction/Loadline › Hull › Bottom Plating
Issued 14 March 2018
Resolved
Hull structure and its appurtenance must be in satisfactory condition as required by 46 CFR 176.25-5. Found major steel wastage on bottom plates in all spaces. Provide hull gauging report to MSD Saipan office.
Action required: 705 - Other - as specified
Resolved 31 October 2019
Fire Fighting › Emergency Fire Pumps › Capacity
Issued 14 March 2018
Resolved
All vessel must have hand operated portable fire pump with at least 5 Gallons per minute as required by 46 CFR 181.10-5. Provide hand portable fire pump.
Due 28 March 2018
Resolved 28 March 2018
Documentation › Certificates/Documents › FCC SSL
Issued 14 March 2018
Resolved
VSL must have valid FCC Station license and safety certificates as required by 47CFR80. Provide proof of valid FCC Station license and safety certificate.
Due 28 March 2018
Resolved 28 March 2018
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 14 March 2018
Resolved
Machinery must be in proper operating conditions as required by 46 CFR 176.25-10. Repair water leaks on STBD engine exhaust pipe.
Due 28 March 2018
Resolved 28 March 2018
Engineering › Fuel Oil Service System › Hose
Issued 14 March 2018
Resolved
Fuel hoses must be in good and serviceable conditions as required by 46 CFR 182.40. Replace damaged (cracked outer layer) fuel hose on STBD engine.
Due 28 March 2018
Resolved 28 March 2018
Construction/Loadline › Structures › Superstructure
Issued 14 March 2018
Resolved
Superstructure must be ins good and serviceable conditions. Replace rot wood in wall lining aft STBD interior wall.
Due 28 March 2018
Resolved 28 March 2018
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 14 March 2018
Resolved
Vessel shall be equipped with suitable portable batter lights as required by 46 CFR 184.30-1. Provide portable battery operate lights.
Due 28 March 2018
Resolved 28 March 2018
Engineering › Reduction Gearing/Clutches › Pinion
Issued 7 February 2017
Resolved
VSL starboard reduction gear failed. Pinion gear sustained damaged to its gear teeth. Conduct repairs in accordance with manufacture instruction using in-kind parts. Inspection and testing to the satisfaction of the attending CG Marine Inspector as required by 46 CFR 176.700
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 February 2017
Communications › Audible Communications › Horn/Whistle
Issued 9 December 2016
Resolved
Vessel must have whistle/horn produces an efficient sound signal as required by COLREGS 72. Repair inoperable ships whistle.
Due 16 December 2016
Resolved 31 October 2019
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 9 December 2016
Resolved
Vessel must have up-to-date charts and Pubs as required by 46 CFR 184.420. Provide missing pubs.
Due 16 December 2016
Resolved 31 October 2019
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 7 November 2016
Resolved
Installed in-kind engine must be tested and inspected by the attending Coast Guard Marine Inspector as required by 46 CFR 176.700. No passenger carry until engine installation is attest by the attending CG MI.
Due 15 November 2016
Resolved 8 November 2016