Records from 1989 to 2025. Most recent: inspection, 4 June 2025.
Inspection history · 62
4 June 2025
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8152328
2 June 2025
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8149661
28 March 2024
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7886588
14 August 2023
Annual Inspection · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7768446
22 June 2022
COI Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7482734
17 August 2021
Examination of Repairs · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7289049
4 August 2021
Hull Examination · Internal Structural Exam · In-Service Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7277108
15 October 2020
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7078018
23 June 2020
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6987784
17 July 2019
Administrative Inspection · Drydock Exam · Annual Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6751657
1 April 2019
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6653983
11 September 2018
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6538309
13 July 2017
Internal Structural Exam · Hull Examination · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6207728
29 November 2016
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6049432
10 September 2015
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5737621
22 October 2014
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5010229
13 September 2011
Drydock Exam · Hull Examination · Internal Structural Exam · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4144161
26 October 2010
Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3877368
12 January 2010
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3672998
27 August 2008
Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3322523
16 July 2007
Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2996832
25 February 2007
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2877395
23 February 2007
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2877371
23 October 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2806555
8 September 2006
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2775380
23 June 2006
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2694743
15 November 2005
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2534586
22 August 2005
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2467274
9 August 2005
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2456588
14 January 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2275159
25 August 2004
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2192309
28 August 2003
Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1889633
20 August 2002
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1664407
27 August 2001
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1408806
25 August 2000
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1444398
23 August 1999
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1375883
4 February 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 792104
19 November 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1463418
30 June 1998
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 792808
8 December 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 778255
26 February 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 163539
26 February 1997
Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1396659
29 January 1997
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1363937
24 October 1996
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1419684
26 June 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 770743
21 June 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 205935
27 October 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1451013
14 February 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 161361
25 January 1995
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1454147
6 December 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1398171
22 March 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 855810
10 December 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1459065
9 February 1993
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1415791
9 June 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1441962
20 March 1992
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1009911
15 March 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 187795
24 May 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1242087
6 March 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 928421
9 November 1990
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1237969
5 June 1990
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1235471
19 July 1989
Deficiency Check · Examination of Repairs · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1036148
8 June 1989
Initial Certification · Plan Review "T" Boat · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1044494
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 2 June 2025
Resolved
All inlets and discharges led through the vessel's side must be fitted with efficient and accessible valves, located as close to the hull penetrations as is practicable. Butterfly valve for sea chest on port side inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 June 2025
Resolved 6 June 2025
Resolution: Witnessed sat actuation of valve.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 15 October 2020
Resolved
Vessel must provide a means of escape. Vessels forward escape hatch was in the closed position and not easily opened. Vessel must make hatch operational by 1 person.
Vessels engine room escape hatch is exposed on the deck and is not weather tight. Vessel must make hatch watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2020
Resolved 26 October 2020
Resolution: Vessel made hatches watertight and easily operable
08 - Alarms › N/A - No Subsystem › General alarm
Issued 15 October 2020
Resolved
Where the general alarm signal cannot be heard a vessel must provide a flashing or rotating red light. Vessels general alarm light did not flash or rotate. Vessel must provide a red light that flashes or rotates.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2020
Resolved 6 November 2020
Resolution: Vessel installed and tested new red light.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 October 2020
Resolved
Vessels rub rail was damaged as identified with vessel rep during inspection. Vessels rub rail must be repaired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2020
Resolved 26 October 2020
Resolution: Vessel provided proof identifed area has been replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 15 October 2020
Resolved
Vessels storage refrigerator did not have an operational emergency escape device. As configured a crew member could become locked inside the refrigerator. Vessel must provide an emergency escape device.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2020
Resolved 26 October 2020
Resolution: Vessels storage refrigerator did not have an operational emergency escape device. As configured a crew member could become locked inside the refrigerator. Vessel must provide an emergency escape device.
05 - Radio Communications › N/A - No Subsystem › Reserve source of energy
Issued 11 September 2018
Resolved
VHF with DSC capability was not on emergency power as required per 47 CFR 80.905(a)(3).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2018
Resolved 19 September 2018
Resolution: Corrected.
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 11 September 2018
Resolved
The forward watertight door indicator light in the pilothouse was inoperable and needs to be fixed per 46 CFR 170.255(e).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 September 2018
Resolved 11 September 2018
Resolution: Indicator light was properly connected/installed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 September 2018
Resolved
The bilge alarm for the crew quarters area did not alert at the operating station as required by 46 CFR 182.530.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 September 2018
Resolved 11 September 2018
Resolution: Bilge alarm was fixed, tested and worked properly.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 11 September 2018
Resolved
Survival craft maintenance and inspections (no records or logs provided) were not being conducted as required by 46 CFR 185.720 & .722
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2018
Resolved 11 September 2018
Resolution: Corrected same day.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 29 November 2016
Resolved
Starboard outboard main diesel engine cooling water piping (approx. 2.5' section) needs to be replaced due to excessive corrossion.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2016
Resolved 30 November 2016
Resolution: Replaced corroded section with non-metallic piping and hose clamps. All sat.
Communications › Alarms/Indicators › Bilge Alarm
Issued 29 November 2016
Resolved
Bilge alarm indicator lights were poorly illuminating and not clearly visible.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2016
Resolved 30 November 2016
Resolution: Replaced indicator lights with well lit indicator lights. All sat.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 29 November 2016
Resolved
Guards need to be placed over the shaft/shaft tube areas.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 December 2016
Resolved 30 November 2016
Resolution: Deck plate installed over the area. All sat.
Stability › Unintentional Flooding › General
Issued 27 August 2008
Resolved
Provide means for closure on ballast vents along port side of house.
Due 27 September 2008
Resolved 10 September 2009
Resolution: Vents on the port side were removed and plugged.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 27 August 2008
Resolved
Provide lagging for entire length of exhaust piping on all engines.
Due 27 September 2008
Resolved 10 September 2009
Resolution: Lagging was installed on all machinery in engine room. The lagging on the port outboard engine was corrected on spot for the worklist created during the annual inspection on 10 Sept 09.
Electrical › Electrical Distribution System (service)
Issued 3 September 2003
Resolved
PROVIDE SAFETY MAT IN FROMT OFSWITCHBOARD. LEGACY COMPONENT DESC: Non-conducting Deck Covering
Action required: 705 - Other - as specified
Due 3 October 2003
Resolved 16 September 2003
Engineering › Fuel Oil Service System
Issued 3 September 2003
Resolved
INSTALL CHAFFING GEAR ON ALL ENGINES AS DISCUSSED. LEGACY COMPONENT DESC: Hose
Action required: 705 - Other - as specified
Due 3 October 2003
Resolved 16 September 2003
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 3 September 2003
Resolved
PROVIDE AND INSTALL LIGHT COVERS IN BUNK ROOMS. LEGACY COMPONENT DESC: Berth
Action required: 705 - Other - as specified
Due 3 October 2003
Resolved 16 September 2003
Electrical › Electrical Distribution System (emergency)
Issued 28 August 2003
Resolved
DEMONSTRATE PROPER OPERATION OF EMERGANCY SHUTDOWNS ON BOTH OUTBOARD MAIN ENGINES. LEGACY COMPONENT DESC: Switch, Emergancy Shutdown Main Engine
Action required: 17 - Rectify deficiencies prior to departure
Due 3 October 2003
Resolved 16 September 2003
Lifesaving › Buoyant Apparatus
Issued 28 August 2003
Resolved
RENEW FLOAT LIGHT LINES ON STARBOARD LIFE FLOATS. LEGACY COMPONENT DESC: LIFE FLOAT LIGHT
Action required: 17 - Rectify deficiencies prior to departure
Due 3 October 2003
Resolved 16 September 2003
Lifesaving
Issued 25 August 2000
Resolved
Place battery in waterlight for port bouyant apparatus.
Condition: Unknown
Due 29 August 2000
Resolved 29 August 2000
Construction/Loadline
Issued 25 August 2000
Resolved
Crop and renew stress fractures eminating around the starboard exhaust pipe
Condition: Unknown
Due 29 August 2000
Resolved 29 August 2000
Construction/Loadline
Issued 25 August 2000
Resolved
Repair/weld two stress fractures in forepeak tank, top of bow centerline forward longitudinal.
Condition: Unknown
Due 29 August 2000
Resolved 29 August 2000
Lifesaving
Issued 25 August 2000
Resolved
Connect waterlight to starboard bouyant apparatus.
Condition: Unknown
Due 29 August 2000
Resolved 29 August 2000
Engineering
Issued 25 August 2000
Resolved
Place machinery guard on prime mover for fire monitor.
Condition: Unknown
Due 29 August 2000
Resolved 29 August 2000
Navigation
Issued 25 August 2000
Resolved
Post Emergency Broadcast Placard
Condition: Unknown
Due 29 August 2000
Resolved 29 August 2000
Engineering
Issued 25 August 2000
Resolved
Replace broken gauge to the stbd air receiver (pressure vessel).
Condition: Unknown
Due 29 August 2000
Resolved 29 August 2000
Engineering
Issued 25 August 2000
Resolved
Tighten starboard shaft packing gland.
Condition: Unknown
Due 29 August 2000
Resolved 29 August 2000
Navigation
Issued 25 August 2000
Resolved
Repair/weld stress fractures to port rudder post.
Condition: Unknown
Due 29 August 2000
Resolved 29 August 2000
Unknown
Issued 19 July 1989
Resolved
MAKE PERMANENT REPAIR TO STBD SIDE IN WAY OF FOREPEAK, CREWS QTRS AND GALLEY. DAMAGE AREA LOWEST POINT IS APPROX. 5' ABOVE THE WATERLINE.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989