MAURY USCG vessel records
← All vessels

WASHINGTON

WASHINGTON is a 1989 passenger vessel (inspected). The Coast Guard has recorded 17 inspections since 2016, most recently in June 2026, along with 16 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 2 June 2026.

Built
1989
Last inspected
2 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 2 June 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WAC7605
331672
Flag
UNITED STATES
Maury page id
psix-331672

Documentation record

Registered dimensions (L × B × D)95.8 ft × 37.0 ft × 6.5 ft
Registered tonnagegross 97 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPETERSON BUILDERS · STURGEON BAY, WI, UNITED STATES · built 1989
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portWASHINGTON ISLAND, WI
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 16 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it66 - Regulatory (Subpart C or D), Net Ton
97 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 17

2 June 2026 Administrative Inspection · Annual Inspection · Vessel Attendance
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8405542
20 May 2025 Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8140227
6 June 2024 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7930232
6 June 2023 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7705047
9 August 2022 Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7528796
17 May 2022 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7453206
21 April 2022 Drydock Exam · Administrative Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7453136
25 May 2021 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7206874
2 September 2020 Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7048507
10 December 2019 Deficiency Check
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6871482
5 June 2019 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6704954
3 December 2018 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6591268
29 November 2018 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6589045
11 June 2018 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6442114
5 June 2017 Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6165989
3 April 2017 Examination of Repairs · Internal Structural Exam · Drydock Exam · Plan Review "T" Boat
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6165947
24 May 2016 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 5886740

Deficiency record · 16

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 June 2024 Resolved
The plugs on three ring buoys are cracked wich will lead to water intrusion. Renew life rings.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2024
Resolved 2 July 2024
Resolution: Verified 3 life rings have been renewed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 19 May 2022 Resolved
Observed several items in the first aid kit were expired. Replace expired items iaw 46 CFR 184.710. To be resolved in 30 days.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2022
Resolved 15 June 2022
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 19 May 2022 Resolved
Three Life Jacket donning placards were recently removed. Replace missing placards iaw 46 CFR 185.516. To be resolved before passengers are carried.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2022
Resolved 15 June 2022
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 19 May 2022 Resolved
Crew not present during CG MI attendance. Unable to witness crew drills; Fire, Man Overboard and Abandon Ship drills. Crew drills to be witnessed by CG MI iaw 46CFR185.520 &.524. To be resolved in 30 days.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2022
Resolved 15 June 2022
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 19 May 2022 Resolved
Unable to witness operation of the vehicle decks sprinkler system. Demo operation in the presence of an attending CG [name withheld] 46 CFR 181.300. To be resolved in 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2022
Resolved 15 June 2022
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 19 May 2022 Resolved
Vessel recently made changes in way of the vehicle decks centerline passageway and head configurations. USCG MSC stability review is pending. Vessel is imposed a 10% reduction in load. Restriction imposed until stability review complete as required by 46 CFR 176.306. To be resolved within 14 days.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2022
Resolved 6 June 2022
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 May 2021 Resolved
Each hatch used as a means of escape must be capable of being opened by one person from wither side. Emergency escape hatch from the LAZ/ER cannot be opened from inside the space; rectify with handle or new scuttle cover. 46 CFR 177.500(h)
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2021
Resolved 11 June 2021
Resolution: fitted with prybar that is permanently attached at the scuttle exit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 September 2020 Resolved
Each vessel must carry one floating light that is approved IAW 46CFR160.110. The tether attaching the floating light to the ring buoy was dry rotted. 46CFR180.70(d)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 September 2020
Resolution: Vessel rep sent pictures of new tether.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 September 2020 Resolved
Fire hoses must be conform to UL19. Fire hose onboard had a hole in it. 46CFR181.320(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 September 2020
Resolution: Replaced fire hose with new one.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 2 September 2020 Resolved
Shutoff valves are to be fitted in the fuel supply line as close to the tank as possible. The shut off valve was siezed and could not be operated. 46CFR182.455(b)(4)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 2 September 2020
Resolution: crew performed maintenance and was able to actuate the valve.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 June 2019 Resolved
Observed reflective retro worn on several life jackets. Condition of all life jackets reflective retro shall be checked. All worn reflective retro tape is to be renewed. Company rep to provide attending CG Marine Inspector a statement when all checked and verified.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2019
Resolved 10 December 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 June 2019 Resolved
Observed several items within the first aid kit were expired. Renew all expired items.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2019
Resolved 10 June 2019
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 6 June 2017 Resolved
Name of vessel is faded and barley readable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 June 2017
Resolved 8 June 2017
Resolution: Vsl name has been renewed on all lifebuoys.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 5 June 2017 Resolved
Retroreflective material is worn on several PFD's: renew as needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 June 2017
Resolved 19 June 2017
Resolution: Company replaced reflective SOLAS tape on 43 Adult jackets and 7 Child Jackets
Engineering › Fuel Oil Service System › Valve, Control
Issued 24 May 2016 Resolved
The remote fuel valve shut down assembly did not consistently function and was hanging up. Repair or replace remote fuel valve shut down assembly. Prove proper and consistent operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 13 June 2016
Resolution: [name withheld] attended vessel and verified new remote pull cable installation. Tested remote pull and fuel shut off valve. All sat.
Fire Fighting › Nozzles › Approval
Issued 24 May 2016 Resolved
Fire hose nozzles were plastic and not an approved type. Current nozzles are servicable but require replacement with approve type. Replace all unapproved installations with ASTM F 1546, 162.027 approved nozzles.-
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 26 May 2016
Resolution: Four new brass fire hose nozzles were purchased and installed.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.