MAURY USCG vessel records Sign in
← All vessels

NEPTUNE

NEPTUNE is a 1989 passenger vessel (inspected). The Coast Guard has recorded 44 inspections since 1989, most recently in May 2026, along with 28 deficiencies.

Records from 1989 to 2026. Most recent: inspection, 14 May 2026.

Built
1989
Last inspected
14 May 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

331673
Flag
UNITED STATES
—
Maury page id
psix-331673

Inspections, by type

…with no type recorded1
Years with a record 33 calendar years (1989–2026)
The 44 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Simplified, Gross Ton
3 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 44

14 May 2026 COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8372171
11 February 2026 Examination of Repairs · Vessel Attendance
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8309317
10 June 2025 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8168597
1 April 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8093162
4 June 2024 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7912286
8 May 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7662404
4 April 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7654545
16 June 2022 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7466407
21 May 2021 COI Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7150125
6 April 2021 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7150130
23 June 2020 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6979231
30 July 2019 DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6758209
15 April 2019 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6653501
17 May 2018 Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6393179
10 July 2017 Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6188644
13 April 2017 Internal Structural Exam · Hull Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6112816
17 May 2016 DAPI Audit · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5868272
1 December 2011 Plan Review "T" Boat
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4199626
7 December 2010 Plan Review "T" Boat · Administrative Inspection · MARPOL Annex VI Survey · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3906121
28 July 2009 Re-Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3537229
20 April 2009 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3441458
6 May 2008 Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3185554
9 May 2007 Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2920798
4 April 2007 Hull Examination · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2901427
6 June 2006 COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2628134
15 June 2005 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2374577
1 April 2005 Examination of Repairs
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2324515
27 October 2004 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2228709
14 June 2004 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2098214
17 July 2003 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1847921
24 July 2002 Hull Examination · Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1650584
15 June 2001 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1405217
14 August 2000 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 821622
27 April 1999 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1126423
23 June 1998 Hull Examination · COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1423099
30 April 1997 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1091981
10 May 1996 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1083168
12 April 1995 Hull Examination · COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1156957
28 April 1994 Hull Examination · Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1358471
18 May 1993 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1429764
28 April 1992 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1266070
28 April 1992 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1266071
25 April 1991 Hull Examination · Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1213242
24 May 1989 Initial Construction-Excluding Oversight · Initial Certification · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 968097

Deficiency record · 28

08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 8 May 2023 Resolved
On a vessel at least 26ft in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. Light does not work.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2023
Resolved 10 May 2023
Resolution: Witnessed light properly working by facetime.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 May 2023 Resolved
A vessel not required to have a power driven fire pump must have at least three 2.5 gallon buckets with an attached lanyard and the words "FIRE BUCKET" stenciled in a contrasting color. Fire buckets are larger than 2.5 gallons.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2023
Resolved 10 May 2023
Resolution: Obtained proper fire buckets and placed them onboard.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 8 May 2023 Resolved
A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First aid kit items are expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2023
Resolved 10 May 2023
Resolution: Obtained new medicine for the first aid kit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 May 2023 Resolved
A vessel must carry one floating waterlight unless it is limited to daytime operations. Floating waterlight does not have a battery in it.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2023
Resolved 10 May 2023
Resolution: Battery has been replaced and waterlight is working properly.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 21 May 2021 Resolved
Before getting underway or as soon as practical thereafter, the master of a vessel shall ensure that a suitable public announcement is made. No safety orientation is provided by the master.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 May 2021
Resolution: New passenger safety orientation drafted to be used.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 21 May 2021 Resolved
The magnetic compass must be illuminated except on a vessel limited to daytime operations. Magnetic compass does not illuminate.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 May 2021
Resolution: Vessel sent photos of illuminated magnetic compass.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 June 2020 Resolved
Prove proper operation of the bilge system. Bilge pump is not operational.
Action required: 60 - Rectify deficiencies prior to movement
Due 23 June 2020
Resolved 24 June 2020
Documentation › Markings/Placards › Lifejacket Placard
Issued 28 July 2009 Resolved
Vessel did not have lifejacket donning placard on board. Properly post lifejacket donning placard IAW 46 CFR 185.516.
Action required: 705 - Other - as specified
Due 4 August 2009
Resolved 18 August 2009
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 28 July 2009 Resolved
Battery in ring buoy waterlight did not have an expiration date. Replace battery in the ring buoy waterlight and place a sticker on the battery with the expiration date.
Action required: 705 - Other - as specified
Due 4 August 2009
Resolved 18 August 2009
Engineering › Steering Gear System › Rudder Stock
Issued 28 July 2009 Resolved
Packing in rudder post had a slight leak. Properly tighten rudder post packing.
Action required: 705 - Other - as specified
Due 4 August 2009
Resolved 18 August 2009
Communications › Radio Communications › VHF Radiotelephone
Issued 28 July 2009 Resolved
Vessel operator did not possess a FCC radio operator permit. Provide FCC radio operator permit.
Action required: 705 - Other - as specified
Due 25 September 2009
Resolved 18 September 2009
Operations/Management › Drills/Instruction › Not Conducted
Issued 28 July 2009 Resolved
Vessel had no record of required training and drills. Vessel must perform and log required training and drills IAW 46 CFR 185.420, 185.520, and 185.524.
Action required: 705 - Other - as specified
Due 4 August 2009
Resolved 18 August 2009
Fire Fighting › Ventilation Systems › Ducts
Issued 20 April 2009 Resolved
Replace forepeak air intake duct with rigid material
Action required: 705 - Other - as specified
Due 10 May 2009
Resolved 15 May 2009
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 20 April 2009 Resolved
Provide closure device for vent in lazarette.
Action required: 705 - Other - as specified
Due 10 May 2009
Resolved 15 May 2009
Engineering › Bilge Water Management System › Valve
Issued 6 May 2008 Resolved
Inline check valve aft of automatic bilge pump leaking. Repair/replace.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2008
Resolved 13 May 2008
Resolution: Valve gasket fitting tightened to eliminate leak.
Communications › Alarms/Indicators › High Water Alarm
Issued 6 May 2008 Resolved
No audible indicator for High Water Alarm.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 May 2008
Resolved 27 May 2008
Resolution: Audible/visual indicator replaced at operating station.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 6 May 2008 Resolved
1 Child PFD rejected due to worn retroreflective material.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2008
Resolved 13 May 2008
Resolution: PFD replaced.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 6 May 2008 Resolved
Provide for all launch operators, proof of enrollment in a approved company drug and alcohol testing program. 46CFR16.230
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 May 2008
Resolved 9 May 2008
Resolution: Proof of enrollment verified by Newport Alliance.
Engineering › Bilge Water Management System › Hose
Issued 9 May 2007 Resolved
Provide portable bilge pump with long enough hose to get section from deepest bilge and discharge overboard.
Condition: Improper Installation
Due 16 May 2007
Resolved 8 June 2007
Resolution: Observed new bilge hose.
Electrical › Electric Supply System (service) › Battery Installation
Issued 9 May 2007 Resolved
Replace wingnuts on battery with permanent connections.
Condition: Placed in Improper Service
Due 16 May 2007
Resolved 10 May 2007
Resolution: Received digital picture of proper connections.
Construction/Loadline › Hull › Hull Plating
Issued 9 May 2007 Resolved
Make proper repairs to soft spot in hull aft of drain plug. Remove vessel from service for repair upon completion of sister vessel's drydock. Notify this office with repair proposal.
Condition: Unknown
Due 30 May 2007
Resolved 8 June 2007
Resolution: Vessel owner removed boat from water and repaired area. Area with water ingress was not structural, and did not constitute part of vessel watertight integrity.
Engineering › Bilge Water Management System › Pump
Issued 6 June 2006 Resolved
Provide additional hose for hand bilge pump to enable suction and discharge from all watertight compartments
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 June 2006
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 June 2006 Resolved
Provide bilge high level alarm I.A.W 46 CFR 182.530 (a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 June 2006
Operations/Management › Passenger Operations › Safety Orientation
Issued 6 June 2006 Resolved
Ensure passenger safety orientation is performed I.A.W 46 CFR 185.506
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 June 2006
Construction/Loadline › Hull › Bottom Plating
Issued 27 October 2004 Resolved
make permanent repairs to hull IWO shaft penetration.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2004
Resolved 7 April 2005
Resolution: Repairs made sat.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 14 June 2004 Resolved
Replace the wasted reflective tape on the 26 adult life jackets and 3 child life jackets
Due 1 July 2004
Resolved 1 July 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 June 2004 Resolved
Replace the expired meds in the first-aid kit.
Due 1 July 2004
Resolved 1 July 2004
Documentation
Issued 12 April 1995 Resolved
PROVIDE PROOF OF COMPLIANCE WITH FCC REGULATIONS FOR RADIO STATION LICENSE FOR VESSEL.
Condition: Unknown
Due 11 December 1995
Resolved 13 December 1995

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.