MAURY USCG vessel records Sign in
← All vessels

GRAND ISLAND

GRAND ISLAND is a 1989 passenger vessel (inspected). The Coast Guard has recorded 60 inspections since 1989, most recently in June 2026, along with 47 deficiencies and 2 casualty investigations between 2012 and 2023.

Records from 1989 to 2026. Most recent: inspection, 15 June 2026.

Built
1989
Last inspected
15 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI7680
331804
Flag
UNITED STATES
367731110
Maury page id
psix-331804

Inspections, by type

…with no type recorded5
Years with a record 34 calendar years (1989–2026)
The 60 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)68.0 ft × 16.1 ft × 7.1 ft
Registered tonnagegross 52 / net 41
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSCHWARZ MARINE CO INC · TWO RIVERS, WI, UNITED STATES · built 1989
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMUNISING, MI
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 29 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it41 - Simplified, Net Ton
52 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI7680MMSI 367731110 · active · compulsorily equipped · granted 4 May 2026, expires 29 April 2036
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

GRAND PORTAL Passenger (Inspected) · MISLE 680888 · 21 May 2012 · activity 4327039

Inspection history · 60

15 June 2026 COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8385630
2 June 2025 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8178369
4 June 2024 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7965128
23 June 2023 Construction Oversight · Examination of Repairs · Plan Review "T" Boat · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7721878
23 June 2023 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7726550
13 June 2023 Annual Inspection · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7752023
30 May 2023 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7700269
21 September 2022 Examination of Repairs
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7563699
14 September 2022 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7572607
24 May 2022 Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7458430
23 June 2021 COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7212477
3 May 2021 Examination of Repairs
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7188337
15 September 2020 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7062723
4 November 2019 Examination of Repairs · Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6861834
3 September 2019 DAPI Audit · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6810825
26 May 2019 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6696145
13 May 2019 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6683586
5 June 2018 DAPI Audit · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6441120
5 June 2017 Deficiency Check · COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6166729
27 September 2016 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6018296
19 September 2016 Deficiency Check · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6007698
9 December 2015 Liferaft Servicing
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 5778329
16 October 2014 Drydock Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5006779
25 August 2014 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4965225
24 June 2014 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4900747
12 July 2012 DAPI Audit · COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4374049
27 June 2012 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4345510
21 May 2012 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4327039
18 May 2012 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4314588
12 November 2010 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3894901
14 September 2010 Annual Inspection · DAPI Audit
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3850336
15 September 2008 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3334686
12 September 2006 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2781361
13 September 2005 Re-Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2491043
14 October 2004 Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2220656
10 September 2004 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2192353
11 July 2004 Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2128777
20 October 2003 Administrative Inspection
Administrative · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1932315
12 September 2003 Periodic Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1906039
26 August 2002 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1668133
27 September 2001 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1370384
22 May 2001 Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1066021
14 September 2000 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1417119
13 October 1999 Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1401102
1 September 1999 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1388899
2 April 1999 Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1459495
10 September 1998 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1449101
18 September 1997 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1114377
21 November 1996 Plan Review "T" Boat
Administrative · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1179046
5 September 1996 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1257336
7 September 1995 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 872372
13 October 1994 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1173184
30 June 1994 Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1177645
17 May 1994 COI Inspection · Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1171820
25 May 1993 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1149247
21 May 1992 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 944588
22 May 1991 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1228264
24 May 1990 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 902032
28 June 1989 Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 896196
16 June 1989 Hull Examination
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 896575

Deficiency record · 47

07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 4 June 2024 Resolved
Emergency fuel shut-off pull cable needs to be re-routed due to being hard to pull.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2024
Resolved 22 September 2024
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 14 September 2022 Resolved
This vessel has never been outfitted with guards for the MDE shafts. I discussed with the reps and they stated during an emergency a crew member may be ordered to the engineroom so I'm requiring shaft guards be installed to protect personnel from injury.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2022
Resolved 13 June 2023
Resolution: guards installed, all sat.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 14 September 2022 Resolved
Electronic charts (GPS) is out of date, must be updated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2022
Resolved 13 June 2023
Resolution: completed.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 23 June 2021 Resolved
Exhaust lagging around turbo has deteriorated and needs to be replaced on both port and stbd engine.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2021
Resolved 7 July 2021
Resolution: Corrected.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 September 2019 Resolved
Install anchor light IAW Inland Navigation Rules. 46CFR183.420
Action required: 705 - Other - as specified
Due 31 May 2020
Resolved 18 May 2020
Resolution: installed & witnessed proper operation.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 3 September 2019 Resolved
Vessel is required to have permanent draft marks at each end of the vessel. 46CFR185.602
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2020
Resolved 18 May 2020
Resolution: corrected.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 September 2019 Resolved
Lazarette audible alarm must be replaced, inaudible with MDE's running. 46CFR182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2019
Resolved 16 September 2019
Resolution: corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 September 2019 Resolved
Stbd side aft most bench seat must be properly marked for pfd stowage (& amount). 46CFR180.78
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2019
Resolved 16 September 2019
Resolution: corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 13 May 2019 Resolved
Total persons allowed is limited to 75 due to 1 of the 2 50 person IBAs temporarily not installed on board the vessel.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2019
Resolved 26 May 2019
Resolution: received photos of installed IBA.
Documentation › Markings/Placards › Lifejacket Placard
Issued 5 June 2018 Resolved
Upper deck child pfd storage area not marked with # of pfd's.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 12 June 2018
Resolved 5 June 2018
Resolution: corrected on the spot.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 June 2018 Resolved
Masthead light inop.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 5 June 2018
Resolved 5 June 2018
Resolution: Corrected prior to my departure.
Electrical › Electric Supply System (service) › Battery Installation
Issued 5 June 2018 Resolved
install battery chocks to prevent shifting.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 19 June 2018
Resolved 5 June 2018
Resolution: chocks installed.
Engineering › Bilge Water Management System › Manifold
Issued 13 June 2017 Resolved
Properly label bilge manifold.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2017
Resolved 22 June 2017
Resolution: Received picture of properly labeled manifold.
Fire Fighting › Fire Hoses › Connections
Issued 13 June 2017 Resolved
Install spanner wrenches at fire stations.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 July 2017
Resolved 28 June 2017
Resolution: Received proof from company rep that wrenches are installed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 June 2017 Resolved
Install machinery guard on stbd MDE exposed rotating machinery.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 19 June 2017
Resolution: Received picture of guard from company rep.
Documentation › Certificates/Documents › Stability Letter
Issued 19 September 2016 Resolved
Post stability letter at operation station.
Condition: Improper Installation
Due 27 September 2016
Resolved 27 September 2016
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 19 September 2016 Resolved
Post emergency instructions at operating station.
Condition: Improper Installation
Due 27 September 2016
Resolved 27 September 2016
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 19 September 2016 Resolved
Demonstrate satisfactory emergency drills (man-overboard and firefighting).
Condition: Invalid
Due 27 September 2016
Resolved 27 September 2016
Construction/Loadline › Hull › Strut/Cross Tie
Issued 16 October 2014 Resolved
Port skeg angle iron has partial hairline fracture at fore connection to hull. Corrected during inspection.
Due 16 October 2014
Resolved 3 November 2014
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 16 October 2014 Resolved
Inlet piping for p/s engine raw water cooling has no external hull strainer, corrected during inspection.
Condition: Improper Installation
Due 16 October 2014
Resolved 3 November 2014
Construction/Loadline › Penetrations › Pipe Flange
Issued 16 October 2014 Resolved
Small diameter sched 40 iron piping inlets for p/s toilet water in tank void excessively wasted, to be cropped and renewed with at least schedule 80 piping. Corrected during inspection.
Due 16 October 2014
Resolved 3 November 2014
Engineering › Steering Gear System › Rudder Bearing
Issued 16 October 2014 Resolved
Rudder shoe bolts not secured against loss during normal operation from vibration, corrected during inspection.
Condition: Improper Installation
Due 16 October 2014
Resolved 3 November 2014
Electrical › Electrical Distribution System (service) › Switch
Issued 24 June 2014 Resolved
Provide means of disconnection in positive wire on main engine cranking batteries.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 July 2014
Resolved 10 July 2014
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 24 June 2014 Resolved
Provide overcurrent protection for small guage wiring at main engine starter positive terminal.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 July 2014
Resolved 10 July 2014
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 June 2014 Resolved
Provide machinery guards on drive belts and pulleys on main engines.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 July 2014
Resolved 10 July 2014
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 June 2014 Resolved
Provide metallic supports on electrical wiring throughout vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 July 2014
Resolved 10 July 2014
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 June 2014 Resolved
Provide a complete first aid kit with current valid contents.
Condition: Improper/Lack of Maintenance
Due 24 July 2014
Resolved 10 July 2014
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 September 2010 Resolved
deleted
Action required: 705 - Other - as specified
Due 1 April 2011
Resolved 14 September 2010
Resolution: deleted
Engineering › Steering Gear System › Rudder Stock
Issued 14 September 2010 Resolved
Repair/replace port rudder stop to proper operating condition as required by 46 CFR 176.25-35 prior to 14OCT10.
Action required: 705 - Other - as specified
Due 14 October 2010
Resolved 12 November 2010
Resolution: Repair/replace port rudder stop to proper operating condition. Deficiency cleared.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 14 September 2010 Resolved
Post emergency instructions at operating station as required by 46 CFR 185.25-1 by 14SEP10.
Action required: 705 - Other - as specified
Due 20 September 2010
Resolved 12 November 2010
Resolution: Post emergency instructions at operating station. Deficiency cleared.
Stability › Weathertight Integrity › General
Issued 14 September 2010 Resolved
Replace cracked port forward bridge window as required by 46 CFR 176.25-50 prior to next operating season.
Action required: 705 - Other - as specified
Due 1 April 2011
Resolved 12 November 2010
Resolution: Replace cracked port forward bridge window. Deficiency cleared.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 14 September 2010 Resolved
Replace 8 worn adult lifejackets as required by 46 CFR 180.25 prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 September 2010
Resolution: Operator replaced 8 worn lifejackets on the spot from sister vessel which is not operating for the rest of the season.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 12 September 2006 Resolved
Repair one inch crack in exhaust manifold prior to 01 oct 2006
Due 1 October 2006
Resolved 14 September 2006
Fire Fighting › Fire Main › Valves
Issued 13 September 2005 Resolved
Prior to carrying passengers replace and test STBD eng Fire main valve
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 October 2005
Resolved 15 September 2005
Fire Fighting › Fire Hoses › Material
Issued 13 September 2005 Resolved
Replace Fire pump belt.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 October 2005
Resolved 15 September 2005
Engineering
Issued 27 September 2001 Resolved
COMPLETE REPAIRS TO PORT MAIN DIESEL ENGINE AND DEMONSTRATE PROPER OPERATION PRIOR TO OPERATING IN YEAR 2002, AND BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 1 June 2002
Resolved 26 August 2002
Resolution: WITNESSED SAT OPERATION OF PORT MAIN DIESEL ENGINE. ALL REPAIRS SAT.
Navigation
Issued 27 September 2001 Resolved
REPAIR STEERING SYSTEM CHAIN DRIVE SPROCKET IN WAY OF 2ND VOID, BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 27 October 2001
Resolved 23 October 2001
Fire Fighting
Issued 27 September 2001 Resolved
REPLACE FIRE NOZZLE ON UPPER PASSENGER DECK, PRIOR TO CARRYING PASSENGERS AND BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 27 October 2001
Resolved 23 October 2001
Lifesaving
Issued 27 September 2001 Resolved
REPLACE DETERIORATED LINES ON RING LIFE BUOY PRIOR TO CARRYING PASSENGERS AND BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 27 October 2001
Resolved 23 October 2001
Lifesaving
Issued 14 September 2000 Resolved
ONE ADULT SIZE AND ONE CHILD SIZE PFD REJECTED DUE TO SPLIT SEWN SEAMS. CORRECTED ON SPOT.
Condition: Unknown
Due 18 September 2000
Resolved 18 September 2000
Lifesaving
Issued 1 September 1999 Resolved
POST LIFEJACKET DONNING PLARARDS PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 15 September 1999
Resolved 22 September 1999
Navigation
Issued 10 September 1998 Resolved
PROVIDE CURRENT COPIES OF 46 CFR SUBCHAPTER T AND NAVIGATION RULES BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 28 September 1998
Resolved 28 September 1998
Engineering
Issued 10 September 1998 Resolved
PERMANENTLY REPAIR COOLING WATER LEAK ON PORT ENGINE EXHAUST PIPING BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 28 September 1998
Resolved 28 September 1998
Engineering
Issued 10 September 1998 Resolved
LABEL FUEL OIL REMOTE SHUT OFF VALVES IN DIRECTION OF CLOSURE BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 28 September 1998
Resolved 28 September 1998
Electrical
Issued 10 September 1998 Resolved
LOOSE CONNECTIONS ON MAIN BATTERIES AND 12VDC CONVERTER TIGHTENED DURING INSPECTION.
Condition: Unknown
Due 28 September 1998
Resolved 28 September 1998
Fire Fighting
Issued 5 September 1996 Resolved
Carry no passengers until leak in pipe-nipple on stbd fire pump has been repaired to satisfaction of attending marine inspector.
Condition: Unknown
Due 6 September 1996
Resolved 6 September 1996
Accommodation/Occupational Safety
Issued 17 May 1994 Resolved
Mark upper deck with maximum persons allowed as indicated on vessel's stability letter.
Condition: Unknown
Due 17 May 1994
Resolved 17 May 1994

Casualty record · 2

21 May 2012Routine · role: Involved in a Marine Casualty · activity 4327039
23 June 2023Routine · role: Involved in a Marine Casualty · activity 7726550
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record