Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)68.0 ft × 16.1 ft × 7.1 ft
Registered tonnagegross 52 / net 41
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSCHWARZ MARINE CO INC · TWO RIVERS, WI, UNITED STATES · built 1989
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMUNISING, MI
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 29 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it41 - Simplified, Net Ton 52 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 21 inspections, each with its date, unit and type; 18 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 21
15 June 2026COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8385630
2 June 2025Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8178369
4 June 2024Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7965128
23 June 2023Construction Oversight · Examination of Repairs · Plan Review "T" Boat · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7721878
23 June 2023Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7726550
13 June 2023Annual Inspection · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7752023
30 May 2023In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7700269
21 September 2022Examination of Repairs
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7563699
14 September 2022Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7572607
24 May 2022Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7458430
23 June 2021COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7212477
3 May 2021Examination of Repairs
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7188337
15 September 2020Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7062723
4 November 2019Examination of Repairs · Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6861834
3 September 2019DAPI Audit · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6810825
26 May 2019Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6696145
13 May 2019Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6683586
5 June 2018DAPI Audit · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6441120
5 June 2017Deficiency Check · COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6166729
27 September 2016Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6018296
19 September 2016Deficiency Check · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6007698
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 4 June 2024Resolved
Emergency fuel shut-off pull cable needs to be re-routed due to being hard to pull.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2024
Resolved 22 September 2024
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 14 September 2022Resolved
This vessel has never been outfitted with guards for the MDE shafts. I discussed with the reps and they stated during an emergency a crew member may be ordered to the engineroom so I'm requiring shaft guards be installed to protect personnel from injury.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2022
Resolved 13 June 2023
Resolution: guards installed, all sat.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 14 September 2022Resolved
Electronic charts (GPS) is out of date, must be updated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2022
Resolved 13 June 2023
Resolution: completed.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 23 June 2021Resolved
Exhaust lagging around turbo has deteriorated and needs to be replaced on both port and stbd engine.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2021
Resolved 7 July 2021
Resolution: Corrected.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Action required: 705 - Other - as specified
Due 31 May 2020
Resolved 18 May 2020
Resolution: installed & witnessed proper operation.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 3 September 2019Resolved
Vessel is required to have permanent draft marks at each end of the vessel.
46CFR185.602
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2020
Resolved 18 May 2020
Resolution: corrected.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 September 2019Resolved
Lazarette audible alarm must be replaced, inaudible with MDE's running.
46CFR182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2019
Resolved 16 September 2019
Resolution: corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 September 2019Resolved
Stbd side aft most bench seat must be properly marked for pfd stowage (& amount).
46CFR180.78
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2019
Resolved 16 September 2019
Resolution: corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 13 May 2019Resolved
Total persons allowed is limited to 75 due to 1 of the 2 50 person IBAs temporarily not installed on board the vessel.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2019
Resolved 26 May 2019
Resolution: received photos of installed IBA.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 5 June 2018
Resolved 5 June 2018
Resolution: Corrected prior to my departure.
Electrical › Electric Supply System (service) › Battery Installation
Issued 5 June 2018Resolved
install battery chocks to prevent shifting.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 19 June 2018
Resolved 5 June 2018
Resolution: chocks installed.
Engineering › Bilge Water Management System › Manifold
Issued 13 June 2017Resolved
Properly label bilge manifold.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2017
Resolved 22 June 2017
Resolution: Received picture of properly labeled manifold.
Fire Fighting › Fire Hoses › Connections
Issued 13 June 2017Resolved
Install spanner wrenches at fire stations.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 July 2017
Resolved 28 June 2017
Resolution: Received proof from company rep that wrenches are installed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 June 2017Resolved
Install machinery guard on stbd MDE exposed rotating machinery.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 19 June 2017
Resolution: Received picture of guard from company rep.
Documentation › Certificates/Documents › Stability Letter
Issued 19 September 2016Resolved
Post stability letter at operation station.
Condition: Improper Installation
Due 27 September 2016
Resolved 27 September 2016
Condition: Improper Installation
Due 27 September 2016
Resolved 27 September 2016
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 19 September 2016Resolved
Demonstrate satisfactory emergency drills (man-overboard and firefighting).
Condition: Invalid
Due 27 September 2016
Resolved 27 September 2016
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.