Inspection history · 16
21 November 2025
Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8262294
4 February 2025
Hull Examination · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8060508
5 November 2024
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8020435
1 November 2023
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7799888
8 March 2023
Simplified Stability Test
Physical examination · Marine Safety Center (MSC) · Activity 7654582
16 February 2023
Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7637833
27 January 2023
Hull Examination · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7619866
25 October 2022
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7562637
19 October 2021
Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7312018
15 March 2021
Annual Inspection · Deficiency Check · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7154936
6 January 2021
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7120312
6 April 2020
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6933185
9 July 2019
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6742944
22 January 2019
COI Inspection · DAPI Audit · Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6613120
4 December 2017
Administrative Inspection · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6314906
31 October 2016
Hull Examination · Deficiency Check · Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6030600
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 February 2023
Resolved
The OCMI may require an inspection and testing whenever a repair or alteration is undertaken.
Vessel completed an engine re-power which requires a PSST. Passenger count reduced from 24 to 17, total persons count reduced from 26 to 19.
46CFR176.700(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2023
Resolved 24 March 2023
Resolution: MSC issued stability letter.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 January 2023
Resolved
The owner or managing operator shall notify the cognizant OCMI of repairs or alterations affecting the safety of the vessel. MI found engines replaced without authorization from the C.G. Notify MSC and comply with their requirements regarding the stability letter. Approval from MSC will be required prior to closing deficiency.
46 CFR 177.665(a)
Action required: 705 - Other - as specified
Resolved 9 March 2023
Resolution: MSC completed PSST. Refer to Actvivity #7637833
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 25 October 2022
Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must have the vessel ready for inspection its fire protection equipment, including each portable fire extinguisher.
MI found the 40-B-C portable fire extinguisher corroded and not sufficiency charged.
46 CFR 176.810(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 October 2022
Resolved 25 October 2022
Resolution: Owner purchased and replaced failed equipment.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 October 2022
Resolved
A vessel must carry one floating waterlight approved in accordance with 46 CFR 161.010 in subchapter Q of this chapter.
MI found the floating waterlight extinguished and battery expired.
46 CFR 180.70(d)(1)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 October 2022
Resolved 25 October 2022
Resolution: Owner replaced battery and tested.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 October 2021
Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry: three hand red flare distress signals and three hand orange smoke distress signals.
MI observe vessel missing 02 distress signals.
46 CFR 180.68(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2021
Resolved 10 November 2021
Resolution: O/O replaced all distress signals
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 19 October 2021
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions.
MI observed vessel did not have an approved first aid kit onboard.
46 CFR 184.710
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2021
Resolved 10 November 2021
Resolution: O/O replaced all first aid kit items IAW with 46 CFR 160.041.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 October 2021
Resolved
An adult life jacket must be provided for each person carried on board a vessel.
MI observed 12 serviceable adult life jackets. Vessel restricted to 12 adult persons until unserviceable life jackets are replaced.
46 CFR 180.71(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2021
Resolved 10 November 2021
Resolution: O/O bought and placed 12 adult lifejackets onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 October 2021
Resolved
Each ring life buoy on a vessel must:
(1) Be approved in accordance with §160.050 in subchapter Q.
MI observed the plug on the ring life buoy is missing, exposing the inner core of the ring buoy.
46 CFR 180.70(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2021
Resolved 10 November 2021
Resolution: O/O replaced life ring buoy. All markings and retro applied.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 October 2021
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required by Table 181.500(b).
MI observed the fire extinguisher at the operation station is a 5-B:C and the fire extinguisher near the engines is a 20-B:C.
46 CFR 181.500 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2021
Resolved 10 November 2021
Resolution: O/O obtained 10 B:C and 2-A portable extinguishers to meet standard. Placed in corresponding locations onboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 October 2021
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket.
Vessel did not have fire buckets onboard.
46 CFR 181.610
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2021
Resolved 10 November 2021
Resolution: All fire buckets were onboard and labeled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 October 2021
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation.
MI observed the fuel shutoff not labeled.
46 CFR 185.608
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2021
Resolved 10 November 2021
Resolution: Fuel shutoff valves were properly labeled and indicated direction of operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 October 2021
Resolved
In systems and applications where flexible hoses are permitted to be clamped:
(1) Double hose clamping is required where practicable;
(2) The clamps must be of a corrosion resistant metallic material;
(3) The clamps must not depend on spring tension for their holding power; and
(4) Two clamps must be used on each end of the hose, or one hose clamp can be used if the pipe ends are expanded or beaded to provide a positive stop against hose slippage.
MI observed fuel hoses to the engines do not have double hose clamps.
46 CFR 182.410
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2021
Resolved 10 November 2021
Resolution: All fuel lines were double clamped.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 19 October 2021
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space.
Master did not have portable lights onboard.
46 CFR 183.430.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2021
Resolved 10 November 2021
Resolution: Verified 02 portable lights onboard.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 March 2021
Resolved
Provide 01 additional fire bucket. Vessel currently has 02 onboard.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 March 2021
Resolved 13 April 2021
Resolution: Vessel owner provided photographic evidence of 01 newly purchased fire bucket.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 March 2021
Resolved
Provide 02 additional flares. Vessel currently maintains 04 for their Lakes, Bays, and Sounds route.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 March 2021
Resolved 13 April 2021
Resolution: Vessel owner provided photographic proof of 02 newly purchased flares.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 March 2021
Resolved
Provide proof of fire extinguisher servicing report. Fire extinguishers show high levels of corrosion and are expired.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2021
Resolved 13 April 2021
Resolution: Vessel owner provided proof of newly purchased and serviced portable fire extinguisher.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 15 March 2021
Resolved
Vessel must install a flame screen of a single screen of corrosion resistant wire of at least 30x30 mesh. Vessel currently has none installed.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2021
Resolved 13 April 2021
Resolution: Vessel owner provided photographic proof of newly installed flame screen.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 4 December 2017
Resolved
Service the A1 FFE near operating station.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2017
Resolved 2 January 2018
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 4 December 2017
Resolved
Provide 2 Life Jackets
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 2 January 2018
Engineering › Bilge Water Management System › Not Operational
Issued 4 December 2017
Resolved
Renew the portable bildge pump.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2017
Resolved 2 January 2018
Construction/Loadline › Penetrations › Bottom Plug
Issued 31 October 2016
Resolved
Replace pontoon plugs with new gasket materail.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 7 November 2016
Resolution: Pontoon plugs were renewed.
Construction/Loadline › Hull › Collision Chock
Issued 31 October 2016
Resolved
Weld fenderign system up forward due to cracked weld.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 7 November 2016
Resolution: Fendering system was renewed.
Fire Fighting › Portable CO2 Fire Extinguisher › Approval
Issued 31 October 2016
Resolved
Fire extinguisher bracket needs approved bracket and not PVC pipe.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 7 November 2016
Resolution: Bracket was replaced.
Fire Fighting › Fire Bucket › Stenciling
Issued 31 October 2016
Resolved
Fire buckets need to be replaced.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 7 November 2016
Resolution: Fire buckets were replaced.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 31 October 2016
Resolved
Life ring line needs replacing.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 7 November 2016
Resolution: Life ring line was replaced.
Engineering › Fuel Oil Service System › Tank
Issued 31 October 2016
Resolved
Fuel tank needs bonding wire renewed.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 7 November 2016
Resolution: Bonding wire was replaced.
Engineering › Fuel Oil Service System › Tank
Issued 31 October 2016
Resolved
Fuel lines need to be organized and too long resulting in chafing.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 7 November 2016
Resolution: Fuel lines were tied off to prevent chafing.