The 6 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Share this recordDownload vessel cardDownload QRMaury, US Coast Guard vessel record for ANNA K, retrieved 18 September 2026. mauryrecords.com/v/psix-332523.html
Documentation record
Tonnage as PSIX records it1167 - Regulatory (Subpart C or D), Gross Ton 356 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 6
20 April 2007Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2911472
9 August 2004PII Safety Exam · ISPS II Exam
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2160496
CLASS TO ADDRESS SOFT PATCHES ON PORT AND STBD BALLAST PIPES ON EFFLUENT SIDE OF BALLAST PUMPS. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 July 2002
Resolved 3 March 2002
Resolution: CLASS ATTESTED TO TEMP REPAIRS WITH PERMANENT NLT 06-02.
Engineering › Steering Gear System
Issued 1 March 2002Resolved
STEERING GEAR DOES NOT HAVE RUDDER ANGLE INDICATOR IN STEERING GEAR ROOM. LEGACY COMPONENT DESC: Rudder Angle Indicator
Condition: Improper Installation
Due 1 July 2002
Resolved 4 March 2002
Resolution: CLASS ATTESTED TO TEMP. REPAIR WITH PERMANENT NLT 06/02
Engineering › Freshwater Generation System
Issued 1 March 2002Resolved
REPAIR SOFT PATCH ON EFFLUENT SIDE OF FRESH WATER GENERATOR. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Due 1 April 2002
Resolved 29 June 2002
Resolution: Permanent repairs completed
REPAIR SOFT PATCH ON SEWAGE LINE LOCATED IN DRY STORES. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Condition: Improper/Lack of Maintenance
Due 1 April 2002
Resolved 29 June 2002
Resolution: Permanent repairs completed
Documentation
Issued 15 June 1989Resolved
33CFRR155.720 A VESSEL WITH A CAPACITY OF 250 OR MORE BARRELS OF OIL WHILE OPERATING IN THE WATERS OF THE U.S. MUST HAVE OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.