Records from 1989 to 2025. Most recent: inspection, 16 September 2025.
Inspection history · 61
16 September 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8235221
14 November 2024
COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8029762
17 September 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8004706
7 February 2024
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7861304
4 October 2022
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7571522
19 July 2022
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7511147
5 January 2022
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7375939
1 February 2021
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7134563
30 September 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7069274
15 November 2019
COI Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6851964
17 January 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6611543
24 October 2018
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6566474
1 February 2018
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6346062
8 February 2017
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6084917
19 October 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6024560
24 November 2015
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5769288
12 November 2015
DAPI Audit
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5765817
27 October 2014
Deficiency Check · In-Service Inspection · COI Inspection · Plan Review "T" Boat · Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5017724
20 October 2014
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5013778
28 December 2011
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4214855
1 December 2011
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4199401
4 August 2011
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4104232
2 November 2010
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3883085
15 December 2009
Hull Examination · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3650011
29 September 2008
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3332264
22 January 2008
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3134372
5 September 2007
Deficiency Check · Annual Inspection · Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3042086
1 August 2006
Hull Examination · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2733819
8 June 2006
Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2674141
3 August 2004
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2149292
26 July 2004
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2145177
27 June 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1881139
25 June 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1826199
5 August 2002
Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1655766
12 July 2002
Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1645107
7 June 2002
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1627440
23 May 2002
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1619978
23 March 2002
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 1631976
4 June 2001
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1410574
29 June 2000
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1467683
18 May 2000
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1467216
16 June 1999
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1450299
9 June 1998
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1392939
22 May 1998
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1394976
19 June 1997
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1390543
1 July 1996
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1086435
24 May 1996
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1084837
5 June 1995
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 877963
27 June 1994
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1337535
11 May 1994
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1169107
4 June 1993
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 827427
5 June 1992
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1262528
21 May 1992
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 952105
24 June 1991
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1200837
10 October 1990
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 907997
19 June 1990
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1234885
26 March 1990
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 909580
28 December 1989
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 911364
16 November 1989
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1224646
5 June 1989
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 932898
5 June 1989
Initial Certification · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1205974
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 September 2025
Resolved
It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury.
MI observed the fuel filter and flame shield was filled with sediment and must be cleaned out or replaced.
46 CFR 182.01-5(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2025
Resolved 22 September 2025
Resolution: Received photo evidence of new fuel filter replacement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 September 2025
Resolved
Flexible hose may be used provided it is fitted with suitable connection fittings and has a high resistance to saltwater, petroleum oils and vibration.
MI observed the exhaust hose is deteriorated and cracked and must be replaced.
46 CFR 182.20-40(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2025
Resolved 17 September 2025
Resolution: Received video evidence of exhaust hose replacement.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 16 September 2025
Resolved
The intent of this part is to insure that the scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection.
MI observed cracks in the starboard aft and starboard forward overhead railings and must be repaired to restore structural integrity.
46 CFR 177.01-5(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2025
Resolved 22 September 2025
Resolution: Received video evidence of restored welding on the starboard aft and starboard forward overhead railings.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 16 September 2025
Resolved
The master and crew of a vessel will be familiar with
the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions.
Emergency instructions were not posted.
46 CFR 185.510(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2025
Resolved 22 September 2025
Resolution: Received photo evidence of emergency instructions posted on vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 September 2024
Resolved
The owner or managing operator shall make a vessel available for drydock examinations, internal structural examinations, and underwater surveys (UWILD) required by this section.
46 CFR 176.600(a)
Vessel must have Dry Dock and Internal Structural Exam prior to operating.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 September 2024
Resolved 18 September 2024
Resolution: Completed Dry Dock and Internal Structural Exam.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 1 February 2021
Resolved
Observed cracked deck in front of the forward engine hatch cover near the starboard foward hatch hinge. Make proper repairs to frp deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 February 2021
Resolution: Crack in deck repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 February 2021
Resolved
Observed deteriorated lines on ring buoy and water float light. Replace/repair lines.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 February 2021
Resolution: Replaced line on water float light.
Fire Fighting › Fire Bucket › Quantity
Issued 9 February 2017
Resolved
Have a minimum of 3 fire buckets onboard (vessel ony had one) 46CFR181.610
Action required: 705 - Other - as specified
Due 16 February 2017
Resolved 2 March 2017
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 9 February 2017
Resolved
Lsbel the number of lifejackets kept onboard. 46CFR180.78
Action required: 705 - Other - as specified
Due 16 February 2017
Resolved 2 March 2017
Construction/Loadline › Penetrations › Gasket
Issued 19 October 2016
Resolved
More than 75% wear on the cutlass bearing. Replace cutlass bearing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 October 2016
Resolved 27 October 2016
Resolution: Cutlass properly replaced with new piece. Deficiency rectified.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 19 October 2016
Resolved
Crack located on starboard longitudinal in way of transum guard. Grind back to good material Utilizing adequate scarf and renew to original lay-up schedule.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 October 2016
Resolved 27 October 2016
Resolution: Adequate repairs made on the starboard longitudinal. Deficiency rectified.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 24 November 2015
Resolved
Replace worn life jacket retro.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 December 2015
Resolved 7 December 2015
Resolution: Lifejacket retro was replaced.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 24 November 2015
Resolved
Renew fire protection tape and insulation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 December 2015
Resolved 7 December 2015
Resolution: Fire protection tape and insulation renewed.
Documentation › Markings/Placards › Lifejacket Placard
Issued 24 November 2015
Resolved
Provide life jacket placard
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 December 2015
Resolved 7 December 2015
Resolution: Life jacket placard provided.
Navigation › Piloting/Steering › Marine Charts
Issued 24 November 2015
Resolved
Provide charts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 December 2015
Resolved 7 December 2015
Resolution: Charts provided.
Engineering › Sea-water System (primary cooling) › Piping
Issued 28 December 2011
Resolved
Heat exchanger has been removed from MDE for service. Replace as original and prove proper operation of main engine.
Action required: 705 - Other - as specified
Resolved 17 January 2012
Stability › Watertight Integrity › General
Issued 28 December 2011
Resolved
Replace chaffed and holed deck drain flex hose in aft compartment.
Action required: 705 - Other - as specified
Resolved 17 January 2012
Stability › Watertight Integrity › General
Issued 28 December 2011
Resolved
Replace missing anchor line deck fitting cover.
Action required: 705 - Other - as specified
Resolved 17 January 2012
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 17 September 2007
Resolved
Replace STBD fuel vent through-hull fitting.
Action required: 705 - Other - as specified
Resolved 18 December 2007
Engineering › Sea-water System (primary cooling) › Valve
Issued 17 September 2007
Resolved
Make sea valve available for USCG inspection.
Action required: 705 - Other - as specified
Resolved 18 December 2007
Construction/Loadline › Hull › Side Shell
Issued 17 September 2007
Resolved
Make proper repairs to fiberglass as identified by USCG marine inspector.
Action required: 705 - Other - as specified
Resolved 13 November 2007
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 5 September 2007
Resolved
Replace retro tape on life jackets.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2007
Resolved 18 December 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 September 2007
Resolved
Replace/repair waterlight and prove operation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2007
Resolved 18 December 2007
Construction/Loadline › Hull › Hull Plating
Issued 5 September 2007
Resolved
Make repairs to hole in lower port rub rail.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2007
Resolved 18 December 2007
Fire Fighting › Structural Fire Protection - General › Hull Construction
Issued 5 September 2007
Resolved
Properly seal fwd bulkhead separating engine room and anchor compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2007
Resolved 18 December 2007
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 5 September 2007
Resolved
Provide servicing report for fixed system and portable extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2007
Resolved 18 December 2007
Fire Fighting › Structural Fire Protection - General › Hull Construction
Issued 5 September 2007
Resolved
Properly seal engine room hatch covers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2007
Resolved 18 December 2007
Construction/Loadline › Structures › Deck Plating
Issued 5 September 2007
Resolved
Provide repair proposal and make proper repairs to deck in anchor space.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2007
Resolved 18 December 2007
Engineering › Fuel Oil Service System › Tank
Issued 5 September 2007
Resolved
Remove fuel oil from stbd bilge and pressure test fuel oil tank.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2007
Resolved 18 December 2007
Engineering › Fuel Oil Service System › Tank
Issued 5 September 2007
Resolved
Properly ground fuel oil fill hose.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2007
Resolved 18 December 2007
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 5 September 2007
Resolved
Provide valid certificate of documentation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2007
Resolved 18 December 2007
Resolution: Vessel is 4 net tons not 5 net tons, not required COD.
Communications › Radio Communications › VHF Radiotelephone
Issued 5 September 2007
Resolved
Provide valid radio license and safety certificate or remove radio.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2007
Resolved 18 December 2007
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 5 September 2007
Resolved
Provide proof of back ground checks, pre-employment testing and EAP training for all employees.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2007
Resolved 18 December 2007
Stability › Severe Wind/Roll › General
Issued 5 September 2007
Resolved
Remove sign from upper deck or prove vessel stability to meet wind heel criteria.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2007
Resolved 18 December 2007
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 5 September 2007
Resolved
Provide alternate means to control engine speed at emergency tiller and prove operation or provide deck hand on vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2007
Resolved 18 December 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 September 2007
Resolved
Prove operation of anchor light.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2007
Resolved 18 December 2007
Lifesaving › Hand Flares › Not on Board
Issued 5 September 2007
Resolved
Provide three day and night hand flares.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2007
Resolved 18 December 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 September 2007
Resolved
Provide 7/16 line on water light.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2007
Resolved 18 December 2007
Personnel › Training › Fire Fighting Basic
Issued 5 September 2007
Resolved
Crew was not available for inspection to conduct drills.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 September 2007
Resolved 18 December 2007
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 5 September 2007
Resolved
Provide 36" high rails fwd of operating station or block off area so that passengers can not access.
Action required: 705 - Other - as specified
Resolved 4 January 2008
Engineering › Bilge Water Management System › Pump
Issued 1 August 2006
Resolved
Replace aft electric sub pump with UL approved pump (Rule 2000, Rule 3000, Etc.)
Action required: 705 - Other - as specified
Resolved 10 August 2006
Construction/Loadline › Hull › Side Shell
Issued 1 August 2006
Resolved
Provide written repair proposal for area of starboard bow.
Action required: 705 - Other - as specified
Resolved 10 August 2006
Engineering › Bilge Water Management System › Valve
Issued 1 August 2006
Resolved
Provide positive control valves at hull for both electric sub pumps.
Action required: 705 - Other - as specified
Resolved 10 August 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 June 2006
Resolved
Provide proper connections on wires IAW 46CFR183.340(h)
Due 22 June 2006
Resolved 14 June 2006
Engineering › Feedwater/Condensate Water System › Piping
Issued 8 June 2006
Resolved
Properly seal hose connection to cooling water on exhaust.
Due 22 June 2006
Resolved 14 June 2006
Documentation › Certificates/Documents › Stability Letter
Issued 8 June 2006
Resolved
Provide proof of vessel's stability test and provide vessel's stability letter onboard. Must be rectified to receive credit drydock scheduled in JUL2006.
Due 31 July 2006
Resolved 1 August 2006
Electrical › Electric Supply System (service) › Cable
Issued 8 June 2006
Resolved
Replace/Renew as original starter cable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 June 2006
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 8 June 2006
Resolved
Implement Drug Program. Provide proof of crewmember enrollment in company's consortium. Provide pre-employment drug testing for crew.
Due 22 June 2006
Resolved 14 June 2006
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 8 June 2006
Resolved
Provide applicable and current chart onboard.
Due 22 June 2006
Resolved 14 June 2006
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 8 June 2006
Resolved
Provide proof the Halon system is of sufficient size and capacity for machinery space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2006
Documentation › Certificates/Documents › Stability Letter
Issued 3 August 2004
Resolved
Post a stability letter, or conduct a simplified stability test for issuance of a new letter. Owner rep stated that the previous owner had lost the original letter. No copy was immediately available.
Condition: Improper/Lack of Maintenance
Due 5 September 2004
Resolved 1 August 2006
Operations/Management › Passenger Operations › Safety Orientation
Issued 3 August 2004
Resolved
Provide a means to maintain passenger count ashore.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2004
Resolved 6 August 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 August 2004
Resolved
Provide a first aid kit (complete IAW subchapter Q).
Condition: Improper/Lack of Maintenance
Due 5 August 2004
Resolved 6 August 2004
Operations/Management › Drills/Instruction › Not Conducted
Issued 3 August 2004
Resolved
Maintain a training log to ensure adequate training of personnel.
Condition: Improper/Lack of Maintenance
Due 5 September 2004
Resolved 10 September 2004
Resolution: Fax received.
Engineering › Bilge Water Management System › Not Operational
Issued 3 August 2004
Resolved
Wire aft submersible pump to provide visual indication of operation. Repair high water alarm to indicate visual and audible alarm.
Condition: Improper Installation
Due 5 September 2004
Resolved 10 September 2004
Resolution: Recieved faxed invoice of work.
Documentation › Certificates/Documents › Stability Letter
Issued 26 July 2004
Resolved
Provide and post a copy of the vessels Stability Letter. COI lists stability letter date of 11JUL89, however owner and unit file does not have hard copy copy or original. CSPV was briefed and the vessel must provide a letter or conduct a new stability test for issuance of new letter. A COI will be issued upon completion of ICOI exam, no operation pending resolution.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 July 2004
Resolved 3 August 2004
Resolution: Cleared and reissued under Act# 2149292
Fire Fighting
Issued 10 October 1990
Resolved
TOTAL NUMBER OF PORTABLE EXTINGUISHERS MUST BE DETERMINED. VESSEL APPEARS TO BE A SPECIAL CASE. OWNER SENDING LETTER REQUEST IN FOR REDUCTION IN NUMBER OF EXTINGUISHERS REQUIRED.
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990