Records from 2016 to 2025. Most recent: inspection, 9 June 2025.
Documentation record
Registered dimensions (L × B × D)55.2 ft × 30.0 ft × 5.4 ft
Registered tonnagegross 14 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSIERRA CLOUD INC · PORT TOWNSEND, WA, UNITED STATES · built 1989
Hull materialFRP (Fiberglass)
PropulsionAuxiliary Sail
Hull shapeSail (Distinct Keel)
Hull configurationTwin Hull
Hailing portINCLINE VILLAGE, NV
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Simplified, Gross Ton
13 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 18
9 June 2025
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8118769
10 July 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7958750
14 May 2024
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7920960
27 June 2023
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7721923
19 May 2023
Deficiency Check · Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7695241
1 July 2022
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7487225
20 June 2021
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7271079
16 July 2020
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7309560
10 June 2020
COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6949159
26 June 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6719018
7 August 2018
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6501237
7 May 2018
Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6405197
11 May 2017
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6131899
8 November 2016
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6043282
23 August 2016
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6114686
23 August 2016
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6115143
21 August 2016
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6109804
21 August 2016
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6110573
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 July 2024
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each normally unmanned space. The vessel's 02 audible alarms were inoperable and did not have a visual alarm installed.
46CFR182.530(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2024
Resolved 16 October 2024
Resolution: MI received evidence of operational bilge alarm.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 10 July 2024
Resolved
A vessel must have stability details on the vessel's COI, a stability letter issued by the OCMI... or an approved stability booklet. The vessel did not have their stability letter on board.
46CFR178.210(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2024
Resolved 7 August 2024
Resolution: Received photo of stability letter on board.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 20 June 2021
Resolved
All passenger accommodations must be arranged and equipped to provide for the safety of the passengers in consideration of the route, modes of operation, and speed of the vessel. Starboard forward hatch hanger is cracked on the aft side. Repair hatch prior to next annual inspection.
46CFR177.800(a)
Action required: 705 - Other - as specified
Due 10 September 2022
Resolved 22 September 2025
Resolution: Clearing old outstanding deficinecy per subsequent inspection results.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 June 2020
Resolved
Each floating waterlight on a vessel carrying only one ring buoy must be attached to the lanyard with a corrosion resistant clip. The waterlight was missing the corrosion resistant clip which was installed in the presence of the Marine Inspector.
46CFR180.10(d)(3)
Action required: 10 - Deficiency Rectified
Due 12 June 2020
Resolved 12 June 2020
Resolution: Corrosion resistant clip was installed in the presence of the Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 June 2019
Resolved
A submersible electric bilge pump may be used as a power bilge pump provided that the pump is listed by an independent laboratory as meeting the requirements in UL 1113. Vessels bilge pumps in port and starboard compartments were non-UL approved. Install UL approved bilge pumps.
46 CFR 182.520(e)(1)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 July 2019
Resolved 28 June 2019
Resolution: Vessel installed UL approved bilge pumps with correlating visual and audible alarms.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 June 2019
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following unmanned spaces: A space with a non-watertight closure, such as a space with a non-watertight hatch on the main deck. Vessels bilge pumps did non provide visual or audible alarm at the operation station. Repair bilge systems visual and audible alarms at the operating station.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 July 2019
Resolved 28 June 2019
Resolution: Vessel installed UL listed bilge pumps with correlating visual and audible alarms.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 June 2019
Resolved
A vessel of more than 26ft in length, but not more than 65ft, must carry a minimum of one life buoy of not less than 24 inches in diameter. Vessels life buoy was to small. Install 24 in life buoy.
46 CFR 180.70 (a)(2)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2019
Resolved 1 July 2019
Resolution: Vessel operator submitted email showing the purchase of the approved sized life buoy. Deficiency cleared.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 7 August 2018
Resolved
Vessel crew must prove proper operation for the bilge high water level alarms. Crew shall conduct 15 minute rounds of the spaces protected by the alarms until the def is resolved.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 August 2018
Resolved 17 August 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 August 2018
Resolved
12 volt batteries in starboard hull must be fitted with a suitable cover to protect terminal connections.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 August 2018
Sail Rigging › Chainplates › Materials
Issued 7 May 2018
Resolved
Replace chainplates in kind prior to next operating season (2019). NVIC 02-16
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2019
Resolved 12 June 2020
Resolution: Verified replacement of chainplates during 2020 COI.
Sail Rigging › Mast Step › Base
Issued 7 May 2018
Resolved
Provide sailboat maintenance plan per NVIC 02-16.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2018
Resolved 5 July 2018
Resolution: Plan provided and added to the vessel electronic file.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 11 May 2017
Resolved
Provide valid Certificate of Documentation 46CFR67.7
Condition: Invalid
Due 11 May 2017
Resolved 11 May 2017
Resolution: Produced valid COD.
Operations/Management › Drills/Instruction › Not Conducted
Issued 11 May 2017
Resolved
Conduct man overboard drill with complete crew and full sail plan rigged. 46CFR176.404
Condition: Improper Installation
Due 11 June 2017
Resolved 5 June 2017
Resolution: Completed man overboard drill under sail.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 11 May 2017
Resolved
Limited to carry 4 children. Provide 2 additional children PFDs. 46CFR180.71
Condition: Invalid
Due 11 May 2017
Resolved 11 May 2017
Resolution: Provided a total of 6 children PFDs.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 May 2017
Resolved
Provide functioning float light for ring buoy. 46CFR180.70
Condition: Improper/Lack of Maintenance
Due 11 June 2017
Resolved 5 June 2017
Resolution: Observed proper operation of ring buoy float light.
Engineering › Bilge Water Management System › Pump
Issued 11 May 2017
Resolved
Prove proper operation of starboard bilge pump at rate of 25GPM. 46CFR182.520
Condition: Improper/Lack of Maintenance
Due 11 May 2017
Resolved 19 May 2017
Resolution: Observed satisfactory bilge suction.
Documentation › Markings/Placards › Lifejacket Placard
Issued 11 May 2017
Resolved
Post life jacket placard appropriate for PFDs onboard. 46CFR185.516
Condition: Improper Installation
Due 11 June 2017
Resolved 5 June 2017
Resolution: Observed appropriate life jacket donning procedures posted.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 9 November 2016
Resolved
Missed annual inspection and continued to operate with passengers. Conduct satisfactory annual inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2017
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 9 November 2016
Resolved
Invalid - Case Pending
Action required: 705 - Other - as specified
Resolved 11 May 2017
Resolution: Observed valid COD.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 9 November 2016
Resolved
Operation without having on board a valid U.S. Coast Guard Certificate of Inspection
Action required: 705 - Other - as specified
Resolved 11 May 2017