MAURY USCG vessel records
← All vessels

JOLLIET TLWP

Built
1989
Last inspected
21 December 2023
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 December 2023
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

KYU643
332658
Flag
UNITED STATES
Maury page id
psix-332658

Documentation record

Tonnage as PSIX records itNot recorded
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 13 inspections, each with its date, unit and type; 19 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 13

21 December 2023 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7841332
21 March 2023 Deficiency Check · Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7655107
1 July 2022 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7503674
26 August 2021 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7326228
10 August 2020 MTSA Verification · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7038976
27 August 2019 COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6789228
22 August 2018 Administrative Inspection · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6519669
10 July 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6474176
16 August 2017 COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6242574
10 March 2017 In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6102658
27 July 2016 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5954602
20 June 2016 COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5913129
13 March 2016 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5839276

Deficiency record · 19

09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 21 March 2023 Resolved
EACH CRANE AND CRANE FOUNDATION ON A UNIT MUST BE DESIGNED IN ACCORDANCE WITH THE AMERICAN PRETOLEUM INSTITUTE SPECIFICATION FOR OFFSHORE CRANES; APR SPEC 2C. DURING INSPECTION, OBSERVED MULTIPLE CHAFED HIGH PRESSURE HYDRAULIC HOSES, INCLUDING ONE LOSE AND LEAKING NEAR THE FITTING, ON THE WEST CRANE. THIS OBSERVED HAZARD HAS POTENTIAL TO LEAD TO CRANE FAILURE, AND IN TURN, POTENTIALLY LEADING TO EITHER SERIOUS INJURY OR DEATH. REQUIRE A THIRD PARTY SURVEY OF BOTH WEST AND EAST CRANES, REPLACING/REPAIRING ANY HIGH PRESSURE HYDRAULIC HOSES AS NECESARY, AND PROVIDE THE USCG A THIRD PARTY REPORT, ATTESTING TO THE PROPER OPERATION OF BOTH EAST AND WEST CRANES IAW OEM STANDARDS; TO THE SATISFACTION OF THE MARINE INSPECTOR.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2023
Resolved 30 March 2023
Resolution: Recieved third party servicing report/tech report of satisfactory condition with repairs done.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 21 March 2023 Resolved
THE EMERGENCY EQUIPMENT PROVIDED, REGARDLESS OF WHETHER OR NOT REQUIRED BY THIS SUBCHAPTER, SHALL BE MAINTAINED IN GOOD CONDITION AT ALL TIMES. INSPECTOR NOTED THE HYDRAULIC PRESSURE GUAGE ON THE STARTING SYSTEM OF LIFEBOAT #2 WAS BROKEN.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2023
Resolved 30 March 2023
Resolution: Recieved purchase order of the guages being on order and shipped to the facility for install.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 21 March 2023 Resolved
Each nonmetallic transfer hose must have no gouges, cuts or slashes that penetrate the first layer of hose reinforcement. Additionally, each hose assembly must have either fully threaded connections, ANSI B16.5 or ANSI B16.24 flanges, or ASTM F1122 quick disconnect couplings. Inspector noted diesel fuel hose below western crane with multiple cuts through outer jacket exposing wire reinforcing. Additionally hose was connected to automatic shutoff nozzle utilizing double hose clamps instead of threaded connection.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2023
Resolved 31 March 2023
Resolution: Received paperwork from facility of new hoses and installation equipment on order and shipped to facility.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 27 August 2019 Resolved
02 Liferaft davits and 04 lifeboats wire ropes for launching lifesaving appliances shall be maintained in good working condition at all times. Wire ropes for launching liferafts and lifeboats were found with no grease. Provide documentation attesting to the serviceability of launching appliance.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2019
Resolved 10 September 2019
Resolution: Received an e-mail from company stating that the manufacture recommended a light coat of spray grease in very harsh environments. Required grease was ordered and will be applied as per manufacture's recommendations.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 27 August 2019 Resolved
Liferafts were improperly stored. Pelican hooks are not installed to properly secure the liferafts to the facility. Provide documentation attesting to the proper stowage of liferafts on the facility.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2019
Resolved 4 November 2019
Resolution: Received an e-mail from company stating that straps and pelicans ordered were properly and installed for the stowage of 03 liferafts.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 22 August 2018 Resolved
There was no approval letter for the EEP onboard. 50 c. 33CFR146.140 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2018
Resolved 5 November 2018
Resolution: Received email proving that the EEP was approved and onboard.
01 - Certificates & Documentation › 013 - Documents › P&A manual
Issued 22 August 2018 Resolved
The 1989 MOM is still in use. There have been significant changes including removal of engines in the turbine plant as well as the diesel generation plant. No record of changes to annotate changes and numbers are erroneous throughout. Resubmit revised MOM for approval. 50 c. 33CFR109.121
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2018
Resolved 27 August 2019
Resolution: Recently approved MOM was onboard.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 August 2018 Resolved
Exterior “A” class doors were modified voiding approval. 50 c. 46CFR108.143
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2018
Resolved 16 November 2018
Resolution: "A" class fire doors were observed operational.
Lifesaving › Lifeboat Equipment › Pump (manual)
Issued 13 March 2016 Resolved
hydrolic hose line on l/b #2 leaks
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 March 2016
Resolved 26 April 2016
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 13 March 2016 Resolved
sea chest is leaking
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 April 2016
Resolved 26 April 2016
Construction/Loadline › Structures › Machinery Space Opening
Issued 13 March 2016 Resolved
Column #3 ladder has a large gap without a backing in case someone slips.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 13 April 2016
Resolved 19 April 2016
Lifesaving › Lifebuoys › Serviceable
Issued 13 March 2016 Resolved
need new retroreflective tape
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2016
Resolved 26 April 2016
Lifesaving › Launching Appliances › Winch
Issued 13 March 2016 Resolved
Placard was missing on mount winch lifeboat #1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 April 2016
Resolved 26 April 2016
Lifesaving › Lifeboat Equipment › Seasickness Bag
Issued 13 March 2016 Resolved
seasick pills and aspirin were expired
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 March 2016
Resolved 26 April 2016
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 13 March 2016 Resolved
lifejackets need to be stenciled with the facility's name
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2016
Resolved 26 April 2016
Lifesaving › Lifeboat Equipment › Painter
Issued 13 March 2016 Resolved
Lifeboat #1 needs a new heaving line along with Lifeboat #2. Quoits are missing and worn.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 April 2016
Resolved 26 April 2016
Lifesaving › Launching Appliances › Winch
Issued 13 March 2016 Resolved
Ladder to lifeboat #2 winch does not have a rail or guard in case someone were to trip or slip.distance between lifeboat and water is around 100ft.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 13 April 2016
Resolved 26 April 2016
Deck/Cargo › Ballast › Pumps
Issued 13 March 2016 Resolved
ensure guard/cover is installed on the ballast pump rotatinf machinery
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 27 March 2016
Resolved 26 April 2016
Deck/Cargo › Ballast › Pumps
Issued 13 March 2016 Resolved
COlunm #3 service water utility pump is severely rusted and weaping repair to original condition
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2016
Resolved 26 April 2016