MAURY USCG vessel records Sign in
← All vessels

JOLLIET TLWP

JOLLIET TLWP is a 1989 industrial vessel. The Coast Guard has recorded 101 inspections since 1989, most recently in December 2023, along with 185 deficiencies — 3 with no resolution recorded —, 1 operational control and 1 casualty investigation in 2012.

Records from 1989 to 2023. Most recent: inspection, 21 December 2023.

Built
1989
Last inspected
21 December 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

KYU643
332658
Flag
UNITED STATES
—
Maury page id
psix-332658

Inspections, by type

…with no type recorded8
…past their stated due date1
Years with a record 34 calendar years (1989–2023)
The 101 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records itNot recorded
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 101

21 December 2023 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7841332
21 March 2023 Deficiency Check · Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7655107
1 July 2022 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7503674
26 August 2021 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7326228
10 August 2020 MTSA Verification · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7038976
27 August 2019 COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6789228
22 August 2018 Administrative Inspection · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6519669
10 July 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6474176
16 August 2017 COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6242574
10 March 2017 In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6102658
27 July 2016 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5954602
20 June 2016 COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5913129
13 March 2016 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5839276
24 July 2015 Annual Inspection
Physical examination · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 5194782
15 October 2014 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4840759
27 July 2012 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4405879
9 May 2012 Deadweight Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4312444
21 December 2011 Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4335166
6 September 2011 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4137475
29 August 2011 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4126071
21 July 2011 In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4208274
23 February 2011 Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3964622
6 December 2010 Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3964550
20 October 2010 Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3924335
2 December 2009 Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3692450
27 January 2009 Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3439183
10 November 2008 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3360570
10 November 2008 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3360666
1 August 2008 Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3437220
30 July 2008 In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3400138
16 January 2008 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3131393
7 December 2007 Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3111092
7 May 2007 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2924386
8 September 2006 COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2778119
6 January 2006 In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2562114
7 December 2005 Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2547495
19 April 2005 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2337486
4 October 2004 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2212846
3 December 2003 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1958237
11 November 2003 In-Service Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1949066
14 October 2003 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1927742
16 September 2003 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1911214
19 August 2003 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1881031
4 August 2003 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1866503
25 October 2002 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1699392
12 April 2002 In-Service Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1652549
22 October 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 772988
5 September 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1436622
16 July 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 92898
17 October 2000 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1384581
18 January 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 814503
20 October 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 790359
22 September 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1464880
21 June 1999 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1421687
7 May 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 6074
3 December 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 805742
23 October 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1404628
14 January 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 773433
16 October 1997 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1394844
1 July 1997 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1113066
28 October 1996 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1402340
15 July 1996 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1089651
6 January 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 883450
19 December 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1079296
24 October 1995 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414531
13 July 1995 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 872112
20 January 1995 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1180712
18 November 1994 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1355038
9 September 1994 Examination of Repairs · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 865439
2 June 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1171198
25 April 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1170483
11 April 1994 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 857931
3 March 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 854242
8 February 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 852735
25 January 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1162618
30 November 1993 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1159617
2 November 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1446032
31 October 1993 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1436792
14 January 1993 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1138669
11 December 1992 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1138223
20 November 1992 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1354223
3 August 1992 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 953220
14 January 1992 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1254537
31 December 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1256626
19 December 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1264921
7 November 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1252560
31 October 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 932588
31 October 1991 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1249496
7 May 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1225110
17 January 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1210853
12 December 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 920884
28 November 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1222674
31 October 1990 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 910899
31 October 1990 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1221462
26 October 1990 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1217956
20 July 1990 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 905409
9 November 1989 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 914851
2 November 1989 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1222844
2 August 1989 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1340208
1 August 1989 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1339309
17 April 1989 Initial Certification · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1210542

Deficiency record · 185

09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 21 March 2023 Resolved
EACH CRANE AND CRANE FOUNDATION ON A UNIT MUST BE DESIGNED IN ACCORDANCE WITH THE AMERICAN PRETOLEUM INSTITUTE SPECIFICATION FOR OFFSHORE CRANES; APR SPEC 2C. DURING INSPECTION, OBSERVED MULTIPLE CHAFED HIGH PRESSURE HYDRAULIC HOSES, INCLUDING ONE LOSE AND LEAKING NEAR THE FITTING, ON THE WEST CRANE. THIS OBSERVED HAZARD HAS POTENTIAL TO LEAD TO CRANE FAILURE, AND IN TURN, POTENTIALLY LEADING TO EITHER SERIOUS INJURY OR DEATH. REQUIRE A THIRD PARTY SURVEY OF BOTH WEST AND EAST CRANES, REPLACING/REPAIRING ANY HIGH PRESSURE HYDRAULIC HOSES AS NECESARY, AND PROVIDE THE USCG A THIRD PARTY REPORT, ATTESTING TO THE PROPER OPERATION OF BOTH EAST AND WEST CRANES IAW OEM STANDARDS; TO THE SATISFACTION OF THE MARINE INSPECTOR.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2023
Resolved 30 March 2023
Resolution: Recieved third party servicing report/tech report of satisfactory condition with repairs done.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 21 March 2023 Resolved
THE EMERGENCY EQUIPMENT PROVIDED, REGARDLESS OF WHETHER OR NOT REQUIRED BY THIS SUBCHAPTER, SHALL BE MAINTAINED IN GOOD CONDITION AT ALL TIMES. INSPECTOR NOTED THE HYDRAULIC PRESSURE GUAGE ON THE STARTING SYSTEM OF LIFEBOAT #2 WAS BROKEN.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2023
Resolved 30 March 2023
Resolution: Recieved purchase order of the guages being on order and shipped to the facility for install.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 21 March 2023 Resolved
Each nonmetallic transfer hose must have no gouges, cuts or slashes that penetrate the first layer of hose reinforcement. Additionally, each hose assembly must have either fully threaded connections, ANSI B16.5 or ANSI B16.24 flanges, or ASTM F1122 quick disconnect couplings. Inspector noted diesel fuel hose below western crane with multiple cuts through outer jacket exposing wire reinforcing. Additionally hose was connected to automatic shutoff nozzle utilizing double hose clamps instead of threaded connection.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2023
Resolved 31 March 2023
Resolution: Received paperwork from facility of new hoses and installation equipment on order and shipped to facility.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 27 August 2019 Resolved
02 Liferaft davits and 04 lifeboats wire ropes for launching lifesaving appliances shall be maintained in good working condition at all times. Wire ropes for launching liferafts and lifeboats were found with no grease. Provide documentation attesting to the serviceability of launching appliance.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2019
Resolved 10 September 2019
Resolution: Received an e-mail from company stating that the manufacture recommended a light coat of spray grease in very harsh environments. Required grease was ordered and will be applied as per manufacture's recommendations.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 27 August 2019 Resolved
Liferafts were improperly stored. Pelican hooks are not installed to properly secure the liferafts to the facility. Provide documentation attesting to the proper stowage of liferafts on the facility.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2019
Resolved 4 November 2019
Resolution: Received an e-mail from company stating that straps and pelicans ordered were properly and installed for the stowage of 03 liferafts.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 22 August 2018 Resolved
There was no approval letter for the EEP onboard. 50 c. 33CFR146.140 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2018
Resolved 5 November 2018
Resolution: Received email proving that the EEP was approved and onboard.
01 - Certificates & Documentation › 013 - Documents › P&A manual
Issued 22 August 2018 Resolved
The 1989 MOM is still in use. There have been significant changes including removal of engines in the turbine plant as well as the diesel generation plant. No record of changes to annotate changes and numbers are erroneous throughout. Resubmit revised MOM for approval. 50 c. 33CFR109.121
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2018
Resolved 27 August 2019
Resolution: Recently approved MOM was onboard.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 August 2018 Resolved
Exterior “A” class doors were modified voiding approval. 50 c. 46CFR108.143
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2018
Resolved 16 November 2018
Resolution: "A" class fire doors were observed operational.
Lifesaving › Lifeboat Equipment › Pump (manual)
Issued 13 March 2016 Resolved
hydrolic hose line on l/b #2 leaks
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 March 2016
Resolved 26 April 2016
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 13 March 2016 Resolved
sea chest is leaking
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 April 2016
Resolved 26 April 2016
Construction/Loadline › Structures › Machinery Space Opening
Issued 13 March 2016 Resolved
Column #3 ladder has a large gap without a backing in case someone slips.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 13 April 2016
Resolved 19 April 2016
Lifesaving › Lifebuoys › Serviceable
Issued 13 March 2016 Resolved
need new retroreflective tape
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2016
Resolved 26 April 2016
Lifesaving › Launching Appliances › Winch
Issued 13 March 2016 Resolved
Placard was missing on mount winch lifeboat #1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 April 2016
Resolved 26 April 2016
Lifesaving › Lifeboat Equipment › Seasickness Bag
Issued 13 March 2016 Resolved
seasick pills and aspirin were expired
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 March 2016
Resolved 26 April 2016
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 13 March 2016 Resolved
lifejackets need to be stenciled with the facility's name
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2016
Resolved 26 April 2016
Lifesaving › Lifeboat Equipment › Painter
Issued 13 March 2016 Resolved
Lifeboat #1 needs a new heaving line along with Lifeboat #2. Quoits are missing and worn.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 April 2016
Resolved 26 April 2016
Lifesaving › Launching Appliances › Winch
Issued 13 March 2016 Resolved
Ladder to lifeboat #2 winch does not have a rail or guard in case someone were to trip or slip.distance between lifeboat and water is around 100ft.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 13 April 2016
Resolved 26 April 2016
Deck/Cargo › Ballast › Pumps
Issued 13 March 2016 Resolved
ensure guard/cover is installed on the ballast pump rotatinf machinery
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 27 March 2016
Resolved 26 April 2016
Deck/Cargo › Ballast › Pumps
Issued 13 March 2016 Resolved
COlunm #3 service water utility pump is severely rusted and weaping repair to original condition
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2016
Resolved 26 April 2016
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 27 July 2015 Resolved
OIM could not produce U1-As for air receivers in columns 1 and 4. OIM is to produce U1A's for continued use of the air receivers.
Action required: 705 - Other - as specified
Due 27 August 2015
Resolved 27 August 2015
Resolution: Pressure vessel U1-As were provided on board vessel.
Lifesaving › Launching Appliances › Davit
Issued 27 July 2015 Resolved
Facility does not have a rescue boat. Facility is allowed to use life boat as rescue boat if davit meets the rescue boat retrieval speed. life boat davit did not meet 59 ft /min requirement. Repair davit to meet the requirement or install a rescue boat.
Action required: 705 - Other - as specified
Due 27 August 2015
Resolved 27 August 2015
Resolution: Vessel not required rescue boat due to delivery date and subchapter.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 27 July 2015 Resolved
Facility's overspeed device does not work as required to by regulation. Repair as required.
Action required: 705 - Other - as specified
Due 27 August 2015
Resolved 27 August 2015
Resolution: Overspeed device was repaired.
Personnel › Training › Stability/Ballast Control
Issued 27 July 2015 Resolved
Facilities Ballast Control Officer and OIM could not perform manual stability calculations as prescribed in Marine Operations Manual. Operations Manual is currently under review. Facility to conduct training to ensure all BCOs are able to perform manual stabilty calculations as detailed in the Operations Manual.
Action required: 705 - Other - as specified
Due 27 August 2015
Resolved 27 August 2015
Resolution: New instruction was inserted in Marine operations manual. BCO's studying new instruction manual.
Electrical › Electric Generation Source (emergency) › Generator
Issued 15 October 2014 Resolved
Repair/replace emergency generator tachometer with functioning emergency generator tachometer. Prove proper operation of overspeed test. Provide statement by OIM showing proof of functional tachometer for RPM's.
Due 15 November 2014
Resolved 21 October 2014
Engineering › Pressure Vessel › Marking and Stamping
Issued 15 October 2014 Resolved
Ensure all pressure vessel's listed on the COI have name plates w/ the required data in accordance with 46 CFR 54.10-20 (a).
Due 15 November 2014
Resolved 15 November 2014
Resolution: completed marking and stamping
Accommodation/Occupational Safety › Washroom/Toilet › Location
Issued 15 October 2014 Resolved
Legibly mark marine sanitation device with the following information in accordance with cite 46 CFR 159.055 (a).
Due 15 November 2014
Resolved 6 November 2014
Engineering › Gas Turbine (propulsion-electric) › Gas Generator Turbine
Issued 15 October 2014 Resolved
Prove proper testing of turbine overspeed test according to manufacter's specifications.
Due 15 November 2014
Resolved 6 November 2014
Deck/Cargo › Mooring/Anchoring › Mooring Line/Hawser
Issued 6 September 2011 Resolved
Tension Monitoring System is inoperable.
Action required: 705 - Other - as specified
Due 1 November 2011
Resolved 27 July 2015
Resolution: Tendon Tension Monitoring System appeared to be working as required.
Stability › Incline Test › General
Issued 6 September 2011 No resolution recorded
MC Offshore is to conduct a Deadweight Survey on Jolliet TLWP.
Action required: 705 - Other - as specified
Due 1 November 2011 — due date passed with no resolution recorded
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 29 August 2011 Resolved
Make repaiers to exhaust manifold leak, diesel fire pump "B".
Action required: 705 - Other - as specified
Resolved 5 February 2012
Resolution: Rcvd email supporting completion of deficiency
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 29 August 2011 Resolved
Make repairs to coolant leak, diesel fire pump "A".
Action required: 705 - Other - as specified
Resolved 1 October 2011
Fire Fighting › Fire Main › Condition
Issued 29 August 2011 Resolved
Provide UT report for corrosion in 10" discharge piping at fire pump "B".
Action required: 705 - Other - as specified
Resolved 30 August 2011
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 29 August 2011 Resolved
Make corrections for general corrosion, both diesel fire pumps.
Action required: 705 - Other - as specified
Resolved 6 February 2012
Resolution: Rcvd email supporting completion of deficiency
Construction/Loadline › Structures › Door
Issued 29 August 2011 Resolved
Repair/Replace paint locker door due to corrosion and dogs.
Action required: 705 - Other - as specified
Resolved 22 September 2011
Engineering › Sea-water System (primary cooling) › Valve
Issued 29 August 2011 Resolved
Make repairs fo rpinhole hydraulic leak in control line, Col 4 lower seachest valve.
Action required: 705 - Other - as specified
Resolved 31 August 2011
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 29 August 2011 Resolved
Provide UT reports with U1A sheets for both fire pump start air receivers and seperator start air receiver.
Action required: 705 - Other - as specified
Resolved 30 August 2011
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 29 August 2011 Resolved
Both life boats - lower with assigned crew, unhook and operate in the water.
Action required: 705 - Other - as specified
Resolved 15 January 2012
Resolution: Rcvd email supporting completion of deficiency
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 20 October 2010 Resolved
Replace hatch cover for access at top of column 3.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 November 2010
Resolution: Work item cleared as per email with pictures dated the same.
Electrical › Electric Generation Source (service) › Generator
Issued 27 January 2009 No resolution recorded
Make repairs to Turbines A & B to provide sufficient electrical power for Jolliet’s normal service.
Action required: 705 - Other - as specified
Resolution: Witnessed proper operation during 2010 annual inspection
Electrical › Electric Generation Source (service) › Generator
Issued 27 January 2009 No resolution recorded
Make repairs to all diesel generator prime movers.
Action required: 705 - Other - as specified
Resolution: Witnessed proper operations during 2010 annual inspection
Documentation › Manuals/Policy Documentation › Stability Instructions
Issued 27 January 2009 Resolved
Submit to USCG MSC plans to verify deadweight of Jolliet TWLP. Last stability letter dated 1990, Drill Package removed approx 2001.
Action required: 705 - Other - as specified
Resolved 18 April 2013
Resolution: A preliminary plan was submitted to the CG and scanned into the system by Ray Carrera on 5/23/12.
Engineering › Pressure Vessel › Maximum Allowable Working Pressure
Issued 7 December 2005 Resolved
Provide proof of completion of 5 yr pressure vessel exam NLT 1 Jan 06.
Due 1 January 2006
Resolved 15 December 2005
Resolution: Recieved UT reports, and U1A sheets indicating that all pressure vessels were within their minimum thickness requirements.
Lifesaving › Launching Appliances
Issued 11 November 2003 Resolved
Life raft davit main deck - repair / replace wasted, de-laminated plate by cable drum. LEGACY COMPONENT DESC: Davit
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 February 2004
Resolved 17 February 2004
Resolution: new davit installed
Engineering › Bilge Water Management System
Issued 11 November 2003 Resolved
Column 4 pump rooms - repair / replace bilge pump support structure, wasted LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 January 2004
Resolved 17 February 2004
Engineering › Bilge Water Management System
Issued 11 November 2003 Resolved
Column 2 pump room - bilge pump discharge piping soft patched at "T" just above pump. Crop and renew area LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 December 2003
Resolved 17 February 2004
Deck/Cargo › Ballast
Issued 11 November 2003 Resolved
Tank C2-2 sounding tube wasted / holed, approximately 5 ft above deck, lower elevator landing. Crop and renew effected area LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 December 2003
Resolved 17 February 2004
Engineering › Bilge Water Management System › Pump
Issued 16 September 2003 Resolved
Repair / replace bilge pump and support structure in Column #2, packing bad and structure wasted. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 November 2003
Resolved 19 April 2005
Lifesaving › Lifeboat Equipment
Issued 16 September 2003 Resolved
Hydro test air bottles in # 2 lifeboat due April 2003.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 October 2003
Resolved 14 October 2003
Lifesaving › Launching Appliances
Issued 16 September 2003 Resolved
Conduct five-year load test on releasing gear for both life raft davits or provide documentation it had been completed within the last 5 years LEGACY COMPONENT DESC: Release Mechanism
Action required: 705 - Other - as specified
Due 16 October 2003
Resolved 14 October 2003
Accommodation/Occupational Safety
Issued 16 September 2003 Resolved
Replace bracket for ESD Station #12, severe wastage,
Action required: 705 - Other - as specified
Due 16 October 2003
Resolved 14 October 2003
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 25 October 2002 Resolved
- Prior to operating Generator "C", replace discharged Halon bottle for fixed fire suppression system. LEGACY COMPONENT DESC: Tanks
Condition: Improper/Lack of Maintenance
Due 25 November 2002
Resolved 16 September 2003
Construction/Loadline › Structures
Issued 25 October 2002 Resolved
Repair/Replace double exterior door in Quarters Level 2 Mechanical Room (air handler space). Bottom ¼ of doors wasted/holed. LEGACY COMPONENT DESC: Door
Condition: Unknown
Due 25 December 2002
Resolved 16 September 2003
Electrical
Issued 25 October 2002 Resolved
Repair and prove operation of Bilge Hi-level and bilge pump auto start function in Column II.
Due 8 November 2002
Resolved 16 September 2003
Documentation
Issued 5 September 2001 Resolved
Provide approved copy of Construction Portfolio.
Condition: Unknown
Due 5 September 2001
Resolved 5 September 2001
Electrical
Issued 5 September 2001 Resolved
Provide loss of purge alarms and prove proper operation for all P/P enclosures on drilling package.
Condition: Unknown
Due 30 September 2001
Resolved 4 October 2001
Deck/Cargo
Issued 5 September 2001 Resolved
Remove isolation valve between each safety relief valves on all air receivers (11) and dry bulk tanks (3).
Condition: Unknown
Due 5 September 2001
Resolved 5 September 2001
Fire Fighting
Issued 17 October 2000 Resolved
Crop and renew wasted 2" air purge service water supply line to fire pumps.
Condition: Unknown
Due 17 October 2000
Resolved 17 October 2000
Lifesaving
Issued 17 October 2000 Resolved
Conduct 1.1 operational test of release gear for both lifeboats.
Condition: Unknown
Due 17 October 2000
Resolved 17 October 2000
Fire Fighting
Issued 17 October 2000 Resolved
Renew wasted cabinets for fixed fire extinguishing systems for gas turbine powered generators and renew all wasted fire extinguisher brackets.
Condition: Unknown
Due 17 October 2000
Resolved 17 October 2000
Accommodation/Occupational Safety
Issued 17 October 2000 Resolved
Provide/install 100 psi or less safety relief valves for both domestic water heaters.
Condition: Unknown
Due 17 October 2000
Resolved 17 October 2000
Fire Fighting
Issued 17 October 2000 Resolved
Renew wasted brackets and flex loop for fixed fire extinguishing system at operating gas turbine compressor unit.
Condition: Unknown
Due 17 October 2000
Resolved 17 October 2000
Electrical
Issued 17 October 2000 Resolved
Conduct and log semi-annual load test on emergency batteries.
Condition: Unknown
Due 17 October 2000
Resolved 17 October 2000
Accommodation/Occupational Safety
Issued 17 October 2000 Resolved
Crop and renew wasted and holed handrails throughout rig as necessary.
Condition: Unknown
Due 17 October 2000
Resolved 17 October 2000
Unknown
Issued 17 October 2000 Resolved
Crop and renew wasted 90 deg. elbow on fuel service piping below the #2 crane.
Condition: Unknown
Due 17 October 2000
Resolved 17 October 2000
Lifesaving
Issued 17 October 2000 Resolved
Renew the hatch gaskets on the port life boat.
Condition: Unknown
Due 17 October 2000
Resolved 17 October 2000
Unknown
Issued 22 September 1999 Resolved
PROVE PROPER OPERATION OF TURBINE GENERATORS REVERSE POWER RELAY, PROVIDE 3RD PARTY DOCUMENTATION, ALSO PROVIDE TEST REPORT FOR LOW LUBE OIL PRESSURE, REVERSE POWER, AND OVERSPEED.
Condition: Unknown
Due 25 October 1999
Resolved 25 October 1999
Construction/Loadline
Issued 21 June 1999 Resolved
COMPLETE EXTERNAL TENDON INSPECTION, PROVIDE COPY OF HULL EXAM REPORT TO THE [name withheld].
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Fire Fighting
Issued 23 October 1998 Resolved
RENEW AS ORIGINAL, ISOLATION VALVES AT FIRE HOSE REELS THROUGHOUT AS NECESSARY.
Condition: Unknown
Due 23 November 1998
Resolved 22 December 1998
Lifesaving
Issued 23 October 1998 Resolved
RENEW WINDOWS TO LIFEBOAT NUMBER ONE; AND SERVICE WIRE FALLS TO LIFERAFT DAVITS #1 AND 2. CONDUCT WEIGHT TEST VIA CERTIFIED THIRD PARTY OR IN PRESENCE OF MARINE INSPECTOR.
Condition: Unknown
Due 23 November 1998
Resolved 22 December 1998
Fire Fighting
Issued 23 October 1998 Resolved
CROP AND RENEW AS ORIGINAL, WASTED PIPE RISER TO FIRE MONITOR IN WELL BAY AREA.
Condition: Unknown
Due 23 December 1998
Resolved 22 December 1998
Construction/Loadline
Issued 23 October 1998 Resolved
PROVE PROPER OPERATION OF DRAINAGE SYSTEM TO ALLOW SUFFICIENT DRAINAGE OF FIRE PUMP COOLING WATER.
Condition: Unknown
Due 23 November 1998
Resolved 22 December 1998
Fire Fighting
Issued 23 October 1998 Resolved
REPLACE WASTED HALON BOTTLES TO GAS TURBINE ENGINES._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 October 1998
Resolved 23 October 1998
Deck/Cargo
Issued 23 October 1998 Resolved
PROVE PROPER OPERATION OF ELEVATOR IN COLUMN #1.
Condition: Unknown
Due 23 November 1998
Resolved 22 December 1998
Documentation
Issued 23 October 1998 Resolved
SUBMIT AMMENDED SHIPBOARD OIL POLLUTION EMERGENCY PLAN TO G-MOR FOR REVIEW AND APPROVAL. SEND COPY OF APPROVAL LETTER TO [name withheld].
Condition: Unknown
Due 23 January 1999
Resolved 19 January 1999
Fire Fighting
Issued 23 October 1998 Resolved
REMOVE REMOTE PULL RELEASE MECHANISM AT MESS ROOM BULKHEAD PENETRATION AND PROPERLY SEAL TO MAINTAIN A-60 BOUNDARY.
Condition: Unknown
Due 23 November 1998
Resolved 22 December 1998
Fire Fighting
Issued 23 October 1998 Resolved
CONDUCT HYDROSTATIC TESTING OF ALL PORTABLE HALON EXTINGUISHERS AS NECESSARY.
Condition: Unknown
Due 23 December 1998
Resolved 22 December 1998
Deck/Cargo
Issued 23 October 1998 Resolved
REPAIR BROKEN AIRCRAFT WARNING LIGHT ON EAST CRANE'S GANTRY.
Condition: Unknown
Due 23 October 1998
Resolved 23 October 1998
Lifesaving
Issued 16 October 1997 Resolved
IMPLEMENT POLICY TO LOWER LIFE BOATS AND OPERATE LIFE RAFT DAVITS AT EACH DRILL IN ACCORDANCE WITH 46CFR109.213.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Fire Fighting
Issued 16 October 1997 Resolved
REFILL SCBA AIR CYLINDER.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Electrical
Issued 16 October 1997 Resolved
RENEW WIRE CABLE FITTINGS TO JUNCTION BOX IN WELL BAY UNDER FIRE MONITOR #6; RENEW E-STOP FOR HULL C-1 VENT SUPPLY FAN MOTOR AND CRACKED CONTROLLER BOX; AND RENEW BROKEN STUFFING TUBE FOR CABLE RUN.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Construction/Loadline
Issued 16 October 1997 Resolved
REPLACE MISSING DOGS AND MAKE ALL DOGS OPERABLE ON VENTILATION CLOSURES THROUGHOUT RIG AS NECESSARY.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Lifesaving
Issued 16 October 1997 Resolved
PLACE RETROREFLECTIVE MATERIAL ON ALL LIFESAVING EQUIPMENT (LIFE BOATS AND LIFE RINGS) PER NVIC 01-87.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Lifesaving
Issued 16 October 1997 Resolved
REPAIR GENERAL ALARM IN TEMPORARY QUARTERS.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Fire Fighting
Issued 16 October 1997 Resolved
RENEW BUTTERFLY VALVES ON FOAM STATIONS #7 AND #8; FIRE MONITORS #2, #4, #7AND NORTHSIDE MONITOR.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Lifesaving
Issued 16 October 1997 Resolved
CONDUCT AND LOG MONTHLY SAFETY EQUIPMENT INSPECTIONS IN ACCORDANCE WITH 46CFR109.301.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Fire Fighting
Issued 16 October 1997 Resolved
MAKE REPAIRS TO ALL FIREFIGHTING EQUIPMENT IN ACCORDANCE WITH SOTEC REPORT DATED 13OCT97. REPLACE FLEX LINE AND MISSING DEFFUSER HEAD ON PAINT LOCKER FIXED CO2 SYSTEM. SUBMIT AFFF LABORATORY RESULTS TO [name withheld].
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Lifesaving
Issued 16 October 1997 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Electrical
Issued 16 October 1997 Resolved
REPAIR TEMPERATURE SENSING HARNESS AND FREQUENCY METER FOR C GENERATOR.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Lifesaving
Issued 16 October 1997 Resolved
IMPLEMENT POLICY TO TRAIN CREW AND INDUSTRIAL PERSONNEL AND MAINTAIN RECORDS IN ACCORDANCE WITH 46CFR109.213 (g)(h).
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Lifesaving
Issued 16 October 1997 Resolved
IMPLEMENT POLICY TO CONDUCT TRAINING IN USE OF DAVIT LAUCHED LIFE RAFTS AT INTERVAL NOT TO EXCEED 4 MONTHS (ref. 46CFR109.213(g)(5)).
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Lifesaving
Issued 16 October 1997 Resolved
PLACE TRAINING MATERIALS ON BOARD IN ACCORDANCE WITH 46CFR109.213.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Lifesaving
Issued 16 October 1997 Resolved
REPLACE "BEWARE OF TAIL ROTOR" SIGN AND WIND SOCK ON HELIDECK.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Lifesaving
Issued 16 October 1997 Resolved
SERVICE TWO LIFT RAFTS. PROPERLY STENCIL EACH LIFE RAFT WITH NUMBER. TOTAL NUMBER OF PERSONS ON BOARD RESTRICTED TO 48 UNTIL ALL PRIMARY LIFE SAVING EQUIPMENT HAS BEEN SERVICED AND PLACED ON BOARD.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Fire Fighting
Issued 16 October 1997 Resolved
MAKE GALLEY DOOR SELF CLOSING AND LATCH.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Engineering
Issued 16 October 1997 Resolved
HYDROSTATICALLY TEST FUEL TRANSFER HOSE AND LABEL IN ACCORDANCE WITH 33CFR.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Electrical
Issued 16 October 1997 Resolved
REPAIR FUEL PRESSURE SWITCH FOR #2 GENERATOR.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Unknown
Issued 16 October 1997 Resolved
CROP AND RENEW AS ORIGINAL SPOOL PIECE AND VALVE TO SOUNDING TUBE (B.W.T.) C-4-1 IN COLUMN #4.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Construction/Loadline
Issued 1 July 1997 Resolved
SUMIT FINAL REPORT FOR SEA CHEST, SEA VALVE, TENDON, AND TEMPLATE INSPECTIONS TO [name withheld], LA.
Condition: Unknown
Due 1 July 1997
Resolved 1 July 1997
Lifesaving
Issued 28 October 1996 Resolved
REPLACE SMOKE CANNISTER ON RING BUOY.
Condition: Unknown
Due 28 October 1996
Resolved 28 October 1996
Documentation
Issued 28 October 1996 Resolved
PROVIDE APPROVED FIRE CONTROL PLAN.
Condition: Unknown
Due 28 October 1996
Resolved 28 October 1996
Fire Fighting
Issued 28 October 1996 Resolved
PROVIDE SERVICING CERTIFICATES FOR ALL FIREFIGHTING SYSTEMS TO OCMI.
Condition: Unknown
Due 28 October 1996
Resolved 28 October 1996
Construction/Loadline
Issued 15 July 1996 Resolved
SUBMIT FINAL REPORT FOR TYPE I IN PLACE HULL INSPECTION TO [name withheld].
Condition: Unknown
Due 15 July 1996
Resolved 15 July 1996
Fire Fighting
Issued 24 October 1995 Resolved
Properly label all general alarm bells and contact-makers.
Condition: Unknown
Due 22 November 1995
Resolved 22 November 1995
Fire Fighting
Issued 24 October 1995 Resolved
Provide copy of annual foam sample report to [name withheld].
Condition: Unknown
Due 22 November 1995
Resolved 22 November 1995
Lifesaving
Issued 24 October 1995 Resolved
Prove proper purge to BOP remote panel on drill floor.
Condition: Unknown
Due 22 November 1995
Resolved 22 November 1995
Lifesaving
Issued 24 October 1995 Resolved
Remove excess wires on rig floor stbd side.
Condition: Unknown
Due 22 November 1995
Resolved 22 November 1995
Lifesaving
Issued 24 October 1995 Resolved
Prove proper purge to electrical boxes under rig floor.
Condition: Unknown
Due 22 November 1995
Resolved 22 November 1995
Electrical
Issued 24 October 1995 Resolved
Prove proper operation of #1 rig generator overspeed trip and low lube oil pressure alarm.
Condition: Unknown
Due 22 November 1995
Resolved 22 November 1995
Lifesaving
Issued 24 October 1995 Resolved
Recharge breathing air bottle in lifeboat #1.
Condition: Unknown
Due 22 November 1995
Resolved 22 November 1995
Fire Fighting
Issued 24 October 1995 Resolved
Repair/renew as needed all class "A" door frames in way of well bay.
Condition: Unknown
Due 24 October 1995
Resolved 24 October 1995
Lifesaving
Issued 18 November 1994 Resolved
CONDUCT WEIGHT TESTS TO 110% RATED CAPACITY ON BOTH LIFEBOATS.
Condition: Unknown
Due 18 November 1994
Resolved 18 November 1994
Lifesaving
Issued 18 November 1994 Resolved
HYDROSTATICALLY TEST BREATHING AIR BOTTLE LIFEBOAT NO. 2.
Condition: Unknown
Due 14 December 1994
Resolved 14 December 1994
Electrical
Issued 18 November 1994 Resolved
PROVE PROPER OPERATION OF MUD PUMP BOX PURGE SYSTEM.
Condition: Unknown
Due 14 December 1994
Resolved 14 December 1994
Fire Fighting
Issued 18 November 1994 Resolved
PROVIDE ANNUAL FOAM ANALYSIS ON FIREFIGHTING FOAM FOR ALL STATIONS.
Condition: Unknown
Due 18 November 1994
Resolved 18 November 1994
Electrical
Issued 18 November 1994 Resolved
PROVE PROPER OPERATION OF SCR ROOM PURGE INDICATOR ON DRILLERS CONSOLE AND CONSOLE PURGE LOSS INDICATOR.
Condition: Unknown
Due 14 December 1994
Resolved 14 December 1994
Electrical
Issued 18 November 1994 Resolved
PROPERLY INSTALL CONDUCTORS ON DERRICK.
Condition: Unknown
Due 14 December 1994
Resolved 14 December 1994
Electrical
Issued 18 November 1994 Resolved
REMOVE IMPROPER J-BOX ON DRILL FLOOR ADJACENT TO GAS DETECTOR UNIT.
Condition: Unknown
Due 14 December 1994
Resolved 14 December 1994
Electrical
Issued 18 November 1994 Resolved
PROVIDE PURGE FAILURE INDICATOR ON GAS DETECTION UNITS.
Condition: Unknown
Due 14 December 1994
Resolved 14 December 1994
Construction/Loadline
Issued 11 April 1994 Resolved
SUBMIT REPAIR PROPOSAL REGARDING DAMAGE TO TANK C2-7 TO [name withheld], LA.
Condition: Unknown
Due 11 April 1994
Resolved 11 April 1994
Lifesaving
Issued 30 November 1993 Resolved
MAKE LIFEBOAT/RAFT EMBARKATION LIGHTS ADJUSTABLE WITHOUT THE USE OF TOOLS AS PER 46CFR111.75-16.
Condition: Unknown
Due 30 November 1993
Resolved 30 November 1993
Electrical
Issued 2 November 1993 Resolved
INSTALL ARMORED WIRE TO PIT LEVEL INDICATORS.
Condition: Unknown
Due 2 November 1993
Resolved 2 November 1993
Electrical
Issued 2 November 1993 Resolved
REPAIR MUD SYSTEM CONTROL PANEL PURGE INDICATOR.
Condition: Unknown
Due 2 November 1993
Resolved 2 November 1993
Lifesaving
Issued 2 November 1993 Resolved
FILL BREATHING AIR CYLINDER SURVIVAL CAPSULE NO. 2.
Condition: Unknown
Due 2 November 1993
Resolved 2 November 1993
Lifesaving
Issued 2 November 1993 Resolved
REPAIR AND TEST LIMIT SWITCHES SURVIVAL CAPSULE NO. 2.
Condition: Unknown
Due 2 November 1993
Resolved 2 November 1993
Lifesaving
Issued 2 November 1993 Resolved
REPLACE STBD. AND AFT WINDOWS IN SURVIVAL CAPSULE NO. 2 STEERING STATION.
Condition: Unknown
Due 2 November 1993
Resolved 2 November 1993
Lifesaving
Issued 2 November 1993 Resolved
MAKE LIFEBOAT/RAFT EMBARKATION LIGHTS ADJUSTABLE WITHOUT USE OF TOOLS IAW 46CFR111.75-16.
Condition: Unknown
Due 2 November 1993
Resolved 2 November 1993
Lifesaving
Issued 2 November 1993 Resolved
REPAIR AND WEIGHT TEST NO. 1 LIFERAFT DAVIT ASSEMBLY.
Condition: Unknown
Due 2 November 1993
Resolved 2 November 1993
Lifesaving
Issued 2 November 1993 Resolved
CONDUCT WEIGHT TEST OF BOTH SURVIVAL CAPSULES.
Condition: Unknown
Due 2 November 1993
Resolved 2 November 1993
Accommodation/Occupational Safety
Issued 20 November 1992 Resolved
POST WASTE MANAGEMENT PLAN._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 December 1992
Resolved 23 December 1992
Accommodation/Occupational Safety
Issued 20 November 1992 Resolved
PROVIDE AND POST MARPOL V PLACARDS (GARBAGE).
Condition: Unknown
Due 20 December 1992
Resolved 23 December 1992
Electrical
Issued 20 November 1992 Resolved
REPLACE MISSING LATCH AND MAKE ALARM AUDIBLE OR VISUAL FROM NORMALLY MANNEDSPACE ON JUNCTION BOXES (MAIN) SERVING DRILL FLOOR (PURGED) PRIOR TO CONDUCTING DRILLING OPERATIONS.
Condition: Unknown
Due 7 November 1993
Resolved 23 December 1992
Engineering
Issued 20 November 1992 Resolved
TEST OPERATION AND AUTOMATION SYSTEMS ON #3 RIG GENERATOR PRIOR TO DRILLINGOPERATION.
Condition: Unknown
Due 7 November 1993
Resolved 23 December 1992
Engineering
Issued 20 November 1992 Resolved
REPAIR LOW OIL PRESSURE SHUTDOWN SWITCH ON #1 RIG GENERATOR PRIOR TO DRILLING OPERATIONS.
Condition: Unknown
Due 7 November 1993
Resolved 23 December 1992
Electrical
Issued 20 November 1992 Resolved
REPAIR EMERGENCY LIGHT ON DRILL FLOOR.
Condition: Unknown
Due 20 December 1992
Resolved 23 December 1992
Electrical
Issued 20 November 1992 Resolved
THROUGHOUT VESSEL AND RIG PROPERLY SUPPORT CABLES IAW IEEE 45 STANDARDS.
Condition: Unknown
Due 7 November 1993
Resolved 23 December 1992
Documentation
Issued 20 November 1992 Resolved
REVISE OIL TRANSFER OPERATIONS TO INDICATE BUNKERING OF FUEL.
Condition: Unknown
Due 28 February 1993
Resolved 23 December 1992
Electrical
Issued 20 November 1992 Resolved
REPAIR VISUAL AND AUDIBLE PURGE ALARM FOR RIG FLOOR BOP PANEL PRIOR TO CONDUCTING DRILLING OPERATIONS.
Condition: Unknown
Due 7 November 1993
Resolved 23 December 1992
Electrical
Issued 20 November 1992 Resolved
REPAIR D C LIGHTING CONTACT TO TEMPORARY EMERGENCY LIGHTING SYSTEM IN CONTROL ROOM.
Condition: Unknown
Due 20 December 1992
Resolved 23 December 1992
Accommodation/Occupational Safety
Issued 20 November 1992 Resolved
PROVIDE PROPOSAL TO PROVIDE ADEQUATE LOCKER SPACE IN "TEMPORARY" QUARTERS BUILDINGS (2 - 4 MAN ROOMS). QUARTERS RESTRICTED TO 2 PERSONS PENDING SATISFACTORY RESOLUTION.
Condition: Unknown
Due 14 January 1993
Resolved 14 January 1993
Electrical
Issued 20 November 1992 Resolved
REPAIR EMERGENCY LIGHT IN BOTTOM OF COLUMN #2._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 December 1992
Resolved 23 December 1992
Lifesaving
Issued 20 November 1992 Resolved
REPLACE MISSING JACKNIFE AND REPAIR STROBE ON LIFEBOAT #1._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 December 1992
Resolved 23 December 1992
Deck/Cargo
Issued 20 November 1992 Resolved
REPAIR CRANE 87470 (WEST) AS INDICATED IN GULF CRANE SERVICE INC. REPORT DATED 13OCT92. REPAIR CRANE 87471 (EAST) AS INDICATED IN GULF CRANE SERVICE INC. REPORT DATED 12OCT92.
Condition: Unknown
Due 20 December 1992
Resolved 23 December 1992
Fire Fighting
Issued 20 November 1992 Resolved
CONDUCT FOAM ANALYSIS - AFFF.
Condition: Unknown
Due 20 December 1992
Resolved 23 December 1992
Deck/Cargo
Issued 7 November 1991 Resolved
REPAIR LOWER WIPER ON WEST CRANE.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Electrical
Issued 7 November 1991 Resolved
PROPERLY MOUNT ALL WIRING IN SHAKER AREA OVERHEAD, MUD PIT AREA, AND OTHER GENERAL RIG LOCATIONS WITH 5/8" METAL TIE WRAPS AS PER IEEE-45.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Electrical
Issued 7 November 1991 Resolved
PROPERLY HANG WIRING RUNNING TO SUBSTRUCTURE SPOTLIGHTS.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Electrical
Issued 7 November 1991 Resolved
RENEW BROKEN PLASTIC GAUGE COVERS ON OUTSIDE OF "C" GENERATOR BY REMOTE GENERATOR STOP.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Accommodation/Occupational Safety
Issued 7 November 1991 Resolved
PROVIDE APPROPRIATE NON-SKID ON HELOPORT DECKING.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Electrical
Issued 7 November 1991 Resolved
REPAIR GENERAL ALARM BELLS AT FOLOWING LOCVATIONS: AT MAIN GAS COMPRESSOR NEAR RADIATOR FANS, IN FRONT OF LIVING QUARTERS, LOWER DECK INBOARD OF #2 LIFEBOAT, LOWER DECK AT SOUTHWEST CORNER BY #2 COLUMN, MUD PITS AND DRILL FLOOR.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Deck/Cargo
Issued 7 November 1991 Resolved
REPAIR LOAD CELL ON WEST CRANE.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Electrical
Issued 7 November 1991 Resolved
PROVIDE GENERAL ALARM BELL OR ROTATING RED LIGHT IN SHALE SHAKER AREA.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Deck/Cargo
Issued 7 November 1991 Resolved
REPLACE WIRE ROPE FOR BOOM ON EAST CRANE.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Accommodation/Occupational Safety
Issued 7 November 1991 Resolved
PROVIDE PERSONNEL GUARD FOR OMNIPURE UNIT PUMPS - BOTH UNITS.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Accommodation/Occupational Safety
Issued 7 November 1991 Resolved
DETERMINE AND REPAIR ELECTRICAL PROBLEM IN OUTBOARD OMNIPURE UNIT. BOLTS ONFILTER CELL HELD CURRENT.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Deck/Cargo
Issued 7 November 1991 Resolved
RENEW SAFETY LATCH ON CHAIN FOR EAST CRANE CAB AND BOOM PLATFORMS.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Deck/Cargo
Issued 7 November 1991 Resolved
PROVIDE HYDROSTATIC TEST ON FUEL TRANSFER HOSES TO 1.5 TIMES MAWP OF 250 PSI, OR PROVE MAWP OF HOSES IS ONLY 150 PSI.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Accommodation/Occupational Safety
Issued 7 November 1991 Resolved
CONDUCT INTERNAL INSPECTION OF INSTRUMENT AIR RECEIVER AND UTILITY AIR RECEIVER.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Accommodation/Occupational Safety
Issued 7 November 1991 Resolved
REPLACE MISSING SECTION OF PERIPHERAL NETTING AROUND HELOPORT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Documentation
Issued 7 November 1991 Resolved
PROVIDE A COAST GUARD APPROVED CLASSIFIED LOCATION PLAN WHICH INCLUDES DRILL FLOOR AND SHALE SHAKER AREAS AS WELL AS THOSE AREAS SHOWN ON NON- APPROVED DRAWINGS.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Unknown
Issued 28 November 1990 Resolved
ADJUST INBOARD SLEWING STOP ON CRANE LOCATED ON COLUMN #4 SERIAL #068806-C_x001C_TO PREVENT DAMAGE TO PLATFORM STRUCTURE.
Condition: Unknown
Due 28 November 1990
Resolved 28 November 1990
Unknown
Issued 28 November 1990 Resolved
ADJUST OUTBOARD SLEWING STOP ON CRANE LOCATED ON COLUMN #1 TO PREVENT CONTACT WITH PLATFORM UPPER DECK RAILS.
Condition: Unknown
Due 28 November 1990
Resolved 28 November 1990
Unknown
Issued 28 November 1990 Resolved
FULL WEIGHT TEST AND ANNUAL TO BE PERFORMED ON OM900 WEST CRANE SERIAL _x001C_ #87470 WORKING LOAD TO BE LIMITED TO 46800 UNTIL WEIGHT TEST IS COMPLETED.
Condition: Unknown
Due 28 November 1990
Resolved 28 November 1990
Electrical
Issued 31 October 1990 Resolved
PROVIDE CLASS I DIVISION I PHONEBOX WITH PROPER WIRING AND SEALED FITTING (I.E. FOR CLASS I DIVISION I INSTALLATION) FOR EXPLOSION PROOF SPEAKER HORN LOCATED ABOVE DEGASSER.
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Electrical
Issued 31 October 1990 Resolved
PROVIDE LIGHT, WIRING , AND SEALED FITTINGS SUITABLE FOR CLASS I DIVISION I AREA, LOCATED NEXT TO SHALE SHAKER FOR "MOON POOL LIGHTING."
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Electrical
Issued 31 October 1990 Resolved
PROPERLY MOUNT EXPLOSION PROOF JUNCTION BOX LAYING IN CABLE TRAY AFT OF RIGFLOOR.*
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Electrical
Issued 31 October 1990 Resolved
PROVIDE LOSS OF PURGE ALARM TO "OILFIELD INSTRUMENTS" PIT VOLUME TOTALIZERIN ACCORDANCE WITH NFPA - 496 STARBOARD SIDE AFT RIG FLOOR.*
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Electrical
Issued 31 October 1990 Resolved
REPAIR LOSS OF PURGE ALARM TO GEOLOGRAPH UNIT STARBOARD SIDE AFT RIG FLOOR.
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Electrical
Issued 31 October 1990 Resolved
PROPERLY INSTALL FOR CLASS I DIVISION I AREA OR MOVE TO CLASS I DIVISION IIAREA SHALE SHAKER CONTROL PANEL (WIRING MUST BE "ARMORED" OR "MI" WITH CLASS I DIVISION I SEALED FITTINGS.)
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Lifesaving
Issued 31 October 1990 Resolved
PROVIDE 1500 FEET OF AUXILLARY LINE FOR LINE THROWING GUN IN ACCORDANCE WITH 46 CFR 108.517.
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Electrical
Issued 31 October 1990 Resolved
PROVIDE PROPER WIRING AND PROPER SEALED FITTING (I.S. FOR CLASS I DIVISION I INSTALLATION ) FOR EXPLOSION PROOF SPEAKER HORN LOCATED ABOVE DEGASSER.
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Deck/Cargo
Issued 31 October 1990 Resolved
COMPLETE REPAIRS ANDE LOAD TEST "WEST" CRANE IN THE PRESENCE OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Fire Fighting
Issued 31 October 1990 Resolved
RE-CHARGE HALON CYLINDERS FOR MAIN AND EXTENDED SYSTEMS OF TURBINE ENCLOSURES "B".
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Lifesaving
Issued 31 October 1990 Resolved
REPLACE ALL WASTED LINE ON RINGBOUYS.
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Electrical
Issued 31 October 1990 Resolved
CONDUCT TESTING OF EMERGENCY LIGHTING AND POWER SYSTEMS IN ACCORDANCE WITH 46 CFR 109.211.
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Electrical
Issued 31 October 1990 Resolved
CONDUCT TEST OF ALL REVERSE POWER RELAYS IN THE PRESENCE OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Electrical
Issued 31 October 1990 Resolved
PROVIDE SEALED FITTINGS FOR VENTILATION SHUT DOWN EXPLOSION PROOF SWITCH BOXES, FOR HALON SYSTEM ON TURBINE ENCLOSURES.
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Unknown
Issued 31 October 1990 Resolved
PROVIDE SEALED FITTING FOR EXPLOSION PROOF GENERAL ALARM CONTACT MAKER BET-WEEN TURBINE SKIDS ON MAIN DECK.
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Navigation
Issued 31 October 1990 Resolved
REPLACE RELIEF VALVES ON THREE AIR RECIEVERS LOCATED ABOVE DIESEL GENER- ATORS NOT TO EXCEED MAWP OF PVS. ADDITIONALLY HAND RELIEVING DEVICE RE- QUIRED ON ALL RELIEF VALVES (CURRENT MAWP=125, RELIEF SET ON 150).
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Electrical
Issued 31 October 1990 Resolved
PROPERLY INSTALL LOSS OF PURGE ALARM TO "DRILLING" SCR ROOM IN ACCORDANCE WITH NFPA - 496.
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Electrical
Issued 31 October 1990 Resolved
PROVIDE LOSS OF PURGE ALARM TO "ROYAL SERVICE" DERRICK TV MONITOR IN ACC- ORDANCE WITH NFPA - 496 AS CURRENTLY INSTALLED PRESSURE SWITCH DOES NOT DETECT LOSS OF ENCLOSURE PURGE.
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Electrical
Issued 31 October 1990 Resolved
REPAIR LOSS OF PURGE ALARM TO BOP CONTROL PANEL.
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Electrical
Issued 31 October 1990 Resolved
PROVIDE AUDIBLE OR LOSS OF PURGE ALARMS TO SOUTHLAND GAS DETECTOR PANELS THAT CAN BE "READILY" SEEN OR HEARD IN ACCORDANCE WITH NFPA - 496. (VISUALINDICATOR CANNOT BE "READILY" SEEN IN PRESENT LOCATION).
Condition: Unknown
Due 31 October 1990
Resolved 31 October 1990
Unknown
Issued 9 November 1989 Resolved
ENSURE APPROPRIATE INSTALLATION FOR ELECTRICAL SYSTEMS ON DERRICK AND IN _x001C_ BOTH MUD PITS AS PER 46 CFR 171-173.
Condition: Unknown
Due 9 November 1989
Resolved 9 November 1989
Unknown
Issued 9 November 1989 Resolved
PROVE OPERATION OF REVERSE POWER RELAYS FOR GAS TURBINE GENERATORS PRIOR_x001C_ TO USE.
Condition: Unknown
Due 9 November 1989
Resolved 9 November 1989
Unknown
Issued 9 November 1989 Resolved
ENSURE PROPER OPERATION OF HALON SYSTEM AND GAS DETECTION SYSTEMS IN GAS_x001C_ TURBINES PRIOR TO USE WITH WELL GAS.
Condition: Unknown
Due 9 November 1989
Resolved 9 November 1989

Casualty record · 1

27 July 2012Routine · role: Involved in a Marine Casualty · activity 4405879
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.