Records from 1989 to 2022. Most recent: inspection, 1 April 2022.
Inspection history · 29
1 April 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7422567
19 January 2011
Deficiency Check
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 3929203
22 December 2009
PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 3656599
29 October 2007
Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 3099914
19 October 2007
Deficiency Check
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 3085100
29 September 2005
ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2504575
27 September 2005
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2502214
22 September 2005
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2498770
22 February 2005
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2296905
13 February 2005
PII Safety Exam · ISPS II Exam
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2289753
13 February 2005
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2292978
25 February 2004
Deficiency Check · Administrative Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2013040
30 December 2003
Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1971721
22 March 2002
Ballast Water Examination · Passenger/Freight Vessel Examination · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 1493542
24 March 2001
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 288372
14 March 2000
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 275622
12 October 1998
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 729050
12 September 1998
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 420048
14 August 1997
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 406516
1 October 1996
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 187243
9 September 1996
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 394652
1 September 1995
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 382333
30 August 1995
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 382266
9 June 1993
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 358797
15 July 1992
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 653193
15 July 1992
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 653194
7 July 1992
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 351958
14 July 1991
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 344671
9 June 1989
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 330875
Engineering › Bilge Water Management System › Pump
Issued 22 December 2009
Resolved
1420 BILGES CONTAINED 3FT OF OILY WATER AND AUDIBLE ALARM HAS BEEN SILENCED . VESSEL MUST PUMP OFF PRIOR TO DEPARTURE. SOLAS 74 1/11 17C
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 December 2009
Resolution: VESSEL WILL MAINTAIN A WATCH IN THE ENGINE ROOM AND RUN OWS SEPERATOR UNTILL BILGES ARE CLEAN
Fire Fighting › Means of Escape › Blocked
Issued 22 December 2009
Resolved
0960 FOUND EMERGENCY EXIT IN STEERING GEAR ROOM LOCKED FROM OUTSIDE CAN ONLY BE LOCKED FROM INSIDE TO ALLOW CREW TO ESCAPE. 74 SOLAS II-2/53G 10C
Due 22 December 2009
Resolved 22 December 2009
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 13 February 2005
Resolved
Main door leading to engine room and steering grear room do not close automatically and are fitted with hold back devices. Remove hold back devices and repair all doors leading to engine room.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 16 February 2005
Resolved 22 February 2005
Fire Fighting › Means of Escape › Blocked
Issued 13 February 2005
Resolved
Remove mooring line in steering gear room. The mooring line is blocking the emergency escape.
Condition: Placed in Improper Service
Action required: 15 - Rectify deficiencies by next port
Due 16 February 2005
Resolved 22 February 2005
Fire Fighting › Means of Escape › Blocked
Issued 13 February 2005
Resolved
Remove of modify metal grate covering the emergency escape from the funnel. The grate is bolted in place and is not able to serve as an emergency escape.
Condition: Placed in Improper Service
Action required: 15 - Rectify deficiencies by next port
Due 16 February 2005
Resolved 22 February 2005
Operations/Management › Mandatory Ship Reporting Systems
Issued 30 December 2003
Resolved
The vessel does not have a Ballast water Management plan. The Master is keeping a logbook of ballast operations but does not have a written plan for Ballast Water Management. Provide a written Ballast Water Management plan upon arrival to next U.S. port. LEGACY COMPONENT DESC: Ballast Water Management Plan
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 4 January 2004
Resolved 25 February 2004
Resolution: Received proper documentation showing vessel compliance.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 22 March 2002
Resolved
Prove proper operation of the oily water separator to the satisfaction of Class.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 March 2002
Resolved 24 March 2002
Resolution: Class attended and verified the system was properly operating.
Fire Fighting › Structural - A Class Divisions › Service Spaces
Issued 22 March 2002
Resolved
Provide A0 fire screen doors for the service hatches installed in the galley bulkheads leading to the officer and crew mess rooms to the satisfaction of class.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 22 March 2002
Resolved 24 March 2002
Resolution: Class attended and accepted temporary repairs and possibly permanent pending the vessel submitting plans and materials used to manufacture doors to class for review/approval.
Fire Fighting
Issued 12 September 1998
Resolved
FIRE DOORS TIED OPEN OR HAVE HOLD BACK HOOKS. SOLAS 1974, UNAMENDED, CHAPTER II-2, REGULATION 23.
Condition: Unknown
Due 15 September 1998
Resolved 16 September 1998
Construction/Loadline
Issued 12 September 1998
Resolved
LOADLINE NOT PAINTED CONTRASTING COLOR. ILLC 1966, ANNEX I, REGULATION 8.
Condition: Unknown
Due 15 September 1998
Resolved 16 September 1998
Fire Fighting
Issued 12 September 1998
Resolved
FIRE DRILL UNSATISFACTORILY PERFORMED. SOLAS 1974, AMENDED, CHAPTER III, REGULATION 18.
Condition: Unknown
Due 15 September 1998
Resolved 16 September 1998
Lifesaving
Issued 12 September 1998
Resolved
LIFEBOAT DRILL UNSATISFACTORILY CONDUCTED. SOLAS 1974, AMENDED, CHAPTER III, REGULATION 18.
Condition: Unknown
Due 15 September 1998
Resolved 16 September 1998
Lifesaving
Issued 30 August 1995
Resolved
Self activating smokes required by SOLAS 74, III/7.1.3 not rigged for quickrelease.
Condition: Unknown
Due 31 August 1995
Resolved 31 August 1995
Fire Fighting
Issued 30 August 1995
Resolved
Stairway and engineroom fire screen doors held back/not self closing; remove hold back hooks and adjust doors prior to departure from Dutch Harbor (SOLAS 74, II-2/47).
Condition: Unknown
Due 1 September 1995
Resolved 1 September 1995
Navigation
Issued 9 June 1993
Resolved
NOAA CHART #16518 NOT UP-DATED AS REQUIRED BY 33 C.F.R. 164.33(a)(1)
Condition: Unknown
Due 31 August 1995
Resolved 31 August 1995
Engineering
Issued 7 July 1992
Resolved
no table of speed at which bow thruster is effective was available on the vessel for inspection.
Condition: Unknown
Due 31 August 1995
Resolved 31 August 1995