PRIDE OF OREGON

PRIDE OF OREGON is a 1989 passenger vessel (inspected). The Coast Guard has recorded 74 inspections since 1989, most recently in May 2026, along with 103 deficiencies.

Records from 1989 to 2026. Most recent: inspection, 1 May 2026.

Built
1989
Last inspected
1 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

332803
Flag
UNITED STATES
—
Maury page id
psix-332803

Inspections, by type

…with no type recorded2
Years with a record 35 calendar years (1989–2026)
The 74 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.8 ft × 32.0 ft × 5.0 ft
Registered tonnagegross 66 / net 52
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPALATKA SHIPBUILDING · PALATKA, FL, UNITED STATES · built 1989
Hull materialSteel
PropulsionDiesel
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portOREGON, IL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 2 January 2026 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it66 - Regulatory (Subpart C or D), Gross Ton
52 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 74

1 May 2026 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8358799
3 June 2025 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8151155
15 May 2025 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8136454
11 February 2025 Hull Examination
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8088165
14 May 2024 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7912425
5 October 2023 DAPI Audit · In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7804158
9 May 2023 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7684722
25 April 2023 Annual Inspection · In-Service Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7671486
21 February 2023 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7639548
4 April 2022 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7425272
28 March 2022 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7419719
24 May 2021 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7205607
15 April 2021 DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7175522
30 November 2020 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7103459
1 June 2020 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6967167
31 January 2020 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6900549
5 September 2019 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6804386
20 May 2019 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6689704
29 October 2018 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6570361
30 May 2018 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6428772
21 May 2018 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6420468
18 May 2018 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6417655
8 March 2018 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6368449
15 May 2017 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6147155
6 January 2017 Underwater Inspection in lieu of Drydock · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6067010
11 May 2016 DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5879507
27 August 2014 Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4967195
28 May 2014 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4872937
6 May 2014 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4851595
25 May 2012 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4328281
1 February 2012 Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 4241996
13 September 2011 DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4144451
6 December 2010 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3905277
25 October 2010 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3879182
27 October 2008 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3350666
14 April 2008 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3184143
28 November 2007 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3106140
5 November 2007 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3077116
29 July 2007 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3010796
7 June 2007 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2954116
27 March 2007 Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2893487
21 August 2006 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2752330
5 April 2006 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2617557
9 November 2005 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2532305
20 April 2005 Deficiency Check · Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2338600
8 November 2004 Periodic Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2232291
27 September 2004 Administrative Inspection
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2206209
23 October 2003 Deficiency Check · Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1925582
19 August 2002 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1656769
28 March 2002 Internal Structural Exam · Underwater Inspection in lieu of Drydock
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1599124
20 August 2001 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1439248
18 October 2000 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1429432
13 April 2000 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1047581
27 August 1999 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1460339
4 June 1999 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 810933
24 August 1998 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1442739
28 August 1997 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1392816
7 April 1997 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 777922
7 April 1997 Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1364050
26 November 1996 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 872223
6 September 1996 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1427254
20 October 1995 Drydock Extension · Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 877999
29 August 1995 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1402120
12 September 1994 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1429942
27 May 1994 Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1459100
20 September 1993 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1415899
17 September 1993 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1158643
31 August 1992 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 957118
16 September 1991 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1247381
16 September 1991 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1247385
1 October 1990 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 928452
7 September 1989 Plan Review "T" Boat · Initial Certification · Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1222694
27 June 1989 Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 873976
27 June 1989 Plan Review "T" Boat · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 894974

Deficiency record · 103

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 May 2026 Resolved
Electrical equipment on a vessel must be installed and maintained to: (a) Provide services necessary for safety under normal and emergency conditions. Port and starboard running light wires are deteriorated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2026
Resolved 6 May 2026
Resolution: photos provided show lights were rewired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 May 2026 Resolved
Materials used in piping systems must meet the requirements of this subpart and be otherwise acceptable to the cognizant [name withheld] fluid piping for propulsion is missing support brackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2026
Resolved 6 May 2026
Resolution: photo of support provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 15 May 2025 Resolved
Each hatch cover must be attached to the hatch frame or coaming by captive chains, hinges, or other devices to prevent its loss. Install the same on the two bow hatches.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2025
Resolved 3 June 2025
Resolution: Chains installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 May 2025 Resolved
The bilge suctions shall be fitted with suitable strainers. The bilge strainer in the stern space is worn/corroded. Replace the same.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2025
Resolved 3 June 2025
Resolution: New Strainer installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 May 2024 Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: (ii) Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Monthly inspections are not being completed and logged.
Action required: 10 - Deficiency Rectified
Due 14 May 2024
Resolved 14 May 2024
Resolution: Discussed maintenance and logging requirements with crew. Crew completed maintenance in presence of inspector.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 14 May 2024 Resolved
Except as allowed by paragraphs (b) and (c) of this section, before getting underway on a voyage or as soon as practicable thereafter, the master of a vessel shall ensure that suitable public announcements are made informing all passengers of the following: (1) The location of emergency exits, survival craft embarkation areas, and ring life buoys; (2) The stowage location(s) of life jackets; (3) Either: (i) The proper method of donning and adjusting life jackets of the type(s) carried on the vessel including a demonstration of the proper donning of a lifejacket, or (ii) That passengers may contact a crew member for a demonstration as appropriate, prior to beginning an oceans or coastwise voyage; (4) The location of the instruction placards for life jackets and other lifesaving devices; (5) That all passengers will be required to don life jackets when possible hazardous conditions exist, as directed by the master; and (6) If the vessel is operating with reduced manning or equipment requirements in § 176.114 of this chapter. Passenger safety orientation was not being done at the beginning of each voyage.
Action required: 10 - Deficiency Rectified
Due 14 May 2024
Resolved 14 May 2024
Resolution: Master informed of requirement and will play safety orientation tape at the beginning of each voyage.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 14 May 2024 Resolved
A vessel with more than one passenger deck and a vessel with overnight accommodations must have the public address system operable from the operating station. Public address system inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 18 June 2024
Resolution: 18JUN2024: Received videos from [name withheld] showing the public address system is now operable.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 May 2024 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. First aid kit contents were expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 18 June 2024
Resolution: 18JUN2024: Received videos from [name withheld] showing a new first aid kit in onboard vessel.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 May 2024 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: (1) A space with a through-hull fitting below the deepest load waterline, such as a lazarette; (2) A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space. No audible alarm at operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2024
Resolved 18 June 2024
Resolution: 18JUN2024: Received videos from [name withheld] showing the bilge alarm at operating station has audible and visual indication of high water level.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 May 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to: (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Light near female head is missing guard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2024
Resolved 18 June 2024
Resolution: 18JUN2024: Received videos from [name withheld] showing the light fixture near female head has new guard in place.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 10 October 2023 Resolved
Master has informed USCG that there are watertight integrity issues in isolated area of upper deck above aft bar overhead lights. Master has also informed that temp repairs have been made. Vessel shall make permanent repairs to affected area by the end of next Alternate Hull Examination.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 May 2024
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 10 October 2023 Resolved
Vessel has growth in water tank. Perform tank cleaning and flush prior to serving potable water via tank to passengers.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2023
Resolved 15 May 2024
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 10 October 2023 Resolved
03-Develop a written drug and alcohol testing program.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2023
Resolved 14 May 2024
Resolution: Vessel management has developed and implemented a written drug and alcohol testing program.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 10 October 2023 Resolved
-Develop a Employee assistance program which includes the training and education required in 46 CFR 16.401
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2023
Resolved 14 May 2024
Resolution: Vessel management has developed and implemented an employee assistance program which includes the training and education required in 46 CFR 16.401.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 5 October 2023 Resolved
Provide positive test result for [name withheld] as discussed.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2023
Resolved 14 May 2024
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 April 2023 Resolved
Engine room fire station hose is too short at 23'. Replace with proper length.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2023
Resolution: Proper length hose installed on vessel.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 25 April 2023 Resolved
Items in First aid kit expired, replace with new.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 May 2023
Resolution: Expired items replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 25 April 2023 Resolved
Life ring needs to be labeled with vessel name.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2023
Resolution: Life ring is labeled properly
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 25 April 2023 Resolved
Vessel needs to be identified from outside of vessel. Name of vessel on Bow/Stern. Homport of vessel on Stern.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2023
Resolution: Vessel added name plates.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 April 2023 Resolved
Conduct monthly inspection of vessel Fire extinguishers
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 9 May 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 April 2023 Resolved
Remove any combustible materials from from engine room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2023
Resolution: Engine room cleared of materials
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 4 April 2022 Resolved
Missing Belt guard on genset, re-install properly.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 April 2022 Resolved
Missing hardware on 110v panel near main switchboard. install proper screws.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 April 2022
Resolution: Hardware installed properly
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 April 2022 Resolved
Remove excess water from batteries and inside boxes. Batteries appear to be overfilled.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 April 2022 Resolved
Replace hoses on Steering Ram.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 April 2022
Resolution: Hoses were replaced with new.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 April 2022 Resolved
Provide proper DAPI program elements, training, random testing, records, pre-elployment and members enrolled.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 April 2022 Resolved
Upper deck life ring needs new line. Replace line or entire ring.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 April 2022
Resolution: Life rings were replaced with new
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 4 April 2022 Resolved
No. 1 fire station piping has leak where piping meets main deck. Conduct proper repair. This fire station needs proper labeling.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2022
Resolution: Video Provided.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 4 April 2022 Resolved
Remove all plastic waste recepticales from vessel and replace with non-combustible material.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 4 April 2022 Resolved
Provide proof the vessels PA system functions on all deck
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 April 2022
Resolution: Video sent by master showing proper operation of PA.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 May 2021 Resolved
The sanitary pump that delivers river water to toilets for flushing is inoperable. Repair/replace sanitary pump located in lazarette and test. Supply local OCMI with pump replacement nomenclature/details and test repair prior to using sanitary system/toilets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2021
Resolved 24 May 2021
Resolution: Sanitary pump replaced by Ehmen Industries Inc.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 3 May 2021 Resolved
Vessel is required to have 3 red flares and 3 orange smoke or 6 red flare day/night for river route service. Vessel only has 4 for inspection. Meet above requirement to satisfaction of Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2021
Resolved 24 May 2021
Resolution: Vessel purchased additional flares to meet route and condition.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 May 2021 Resolved
Ensure that hull gauging for annual condition assessment are completed to fulfill inspection conducted and reported on 15APR2021 to the satisfaction of Marine Inspector.
Action required: 705 - Other - as specified
Due 30 June 2021
Resolved 30 June 2021
Resolution: Hull gauging complete, reviewed, and filed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 May 2021 Resolved
One (1) child life jacket not servicable. Restricted to 14 children until extra life jacket restored. COI requires 15 child life jacket (10%) of total passengers allowed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2021
Resolved 24 May 2021
Resolution: Vessel purchased Tpye 1 USCG approved child life jacket to meet 10% of total passengers allowed.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 3 May 2021 Resolved
Vessel hydraulic hoses for steering and propulsion on the exterior are deteriorated/rotted. Both rudder exterior hoses shall be replaced. Port and starboard propulsion sides have three (3) hoses each that shall be replaced. Hoses must meet SAE J-1942 and hose end fittings must meet SAE J-1945. Complete for next annual inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 June 2021
Resolution: Hoses were replaced with 8M3K and 12M3K GATES and are present on SAE International J1942 listing.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 June 2020 Resolved
Provide evidence that MIS data collection form is submitted to Commandant by either mail or internet as per 46 CFR 16.500(b) to satisfaction of Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2020
Resolved 3 May 2021
Resolution: Vessel proved through mail receipt that annual MIS report was sent to DOT address as per CFR regulation site 46CFR16.500.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 June 2020 Resolved
Replace broken paddle board on starboard paddle wheel to satisfaction of Marine Inspector. Believed damage from ice season, vessel not pulled out during. 46 CFR M176.25-5 "Old T"
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 3 July 2020
Resolution: Broken paddle was replaced to the satisfaction of attending Marine Inspector.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 June 2020 Resolved
Ensure vessel air receiver system is ready to operate vessel whistle. Prove whistle can operate to satisfaction of Marine Inspector and prior to carriage of passengers. 46 CFR 176.30-1 "Old T"
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 3 July 2020
Resolution: Vessel whistle has been proven to the satisfaction of attending Marine Inspector.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 20 May 2019 Resolved
Provide list of employees in the drug and alcohal program
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2019
Resolved 5 September 2019
Resolution: Provide crew list for DAOI program
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 20 May 2019 Resolved
Provide up to date MIS report
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2019
Resolved 5 September 2019
Resolution: Received updated MIS report
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 May 2019 Resolved
Replace Ring Buoy with approved type
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2019
Resolved 5 September 2019
Resolution: New ring bouy was installed
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 20 May 2019 Resolved
Provide Local Notice to Mariners, Rules of the Road, Coast Pilot
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2019
Resolved 5 September 2019
Resolution: All publications on board vessel
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 20 May 2019 Resolved
Replace fire hose with non kinking type
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2019
Resolved 5 September 2019
Resolution: replace firehose with non-kinking hose
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 May 2019 Resolved
Provide up to date first aid kit
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2019
Resolved 5 September 2019
Resolution: first aid kit equipment has been renewed
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 20 May 2019 Resolved
Updated Chart for area of operation
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2019
Resolved 5 September 2019
Resolution: new chart was purchased
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 20 May 2019 Resolved
repair or replace broken doors in bar area
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2019
Resolved 5 September 2019
Resolution: door was removed and not replace due to no carpenter skills
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 21 May 2018 Resolved
Provide DAPI Info with MIS Report
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2019
Resolved 5 September 2019
Resolution: cleared prior to 2019 operating season
Lifesaving › Hand Flares › Quantity
Issued 21 May 2018 Resolved
Provide correct amount of Flares (6) Had 4 on board.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2018
Resolved 29 October 2018
Resolution: Received photo of flares
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 21 May 2018 Resolved
vessel had 150 adult lifejackets on board, vessels COI has 162 persons listed. vessel is 12 typeone lifejackets short. Reduced Passanger count to 138 pass.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 May 2018
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 21 May 2018 Resolved
Update emergency procedures. Procedures list lifefloats, no safety harness for crew during MOB.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2018
Resolved 29 October 2018
Resolution: Received updated procedures
Lifesaving › Lifebuoys › Serviceable
Issued 21 May 2018 Resolved
Replace lifebuoys. grab line disintegrated when twisted, multiple tears in ring.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2018
Resolved 29 October 2018
Resolution: New Ring Buoy has been installed
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 28 May 2014 Resolved
Renew ring buoy line with 5/16" diameter, floating line 60 feet in length per 46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2014
Resolved 9 July 2014
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 28 May 2014 Resolved
Correct ground fault in the refer circuit. 46 CFR 176.806
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2014
Resolved 9 July 2014
Personnel › Training › First Aid/CPR
Issued 28 May 2014 Resolved
Provide First Aid training for crew.
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 June 2014
Resolved 9 July 2014
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 28 May 2014 Resolved
Properly post EAP information per 46 CFR 16.240
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 June 2014
Resolved 28 May 2014
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 28 May 2014 Resolved
Provide written Drug and Alcohol program as required by 46 CFR 16.113
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 August 2014
Resolved 27 August 2014
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 28 May 2014 Resolved
Provide onboard current Certificate of Documentation per 46 CFR 67
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 June 2014
Resolved 9 July 2014
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 13 September 2011 Resolved
Provide proof of pre employment testing for deckhand [name withheld]
Action required: 705 - Other - as specified
Due 13 October 2011
Resolved 17 October 2011
Resolution: Recieved MRO negative
Personnel › Training › First Aid/CPR
Issued 13 September 2011 Resolved
Provide proof of First Aid Training for crew per 46 CFR 185.420
Action required: 705 - Other - as specified
Due 13 October 2011
Resolved 17 October 2011
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 25 October 2010 Resolved
120v receptacle in engine room mounted near generator has a cracked face and needs to be replaced. CG-835 issued.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 25 November 2010
Resolved 6 December 2010
Resolution: Recepticle cover replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 October 2010 Resolved
Water heaters in both the FWD storage hold and the Lazarette need to be hard-wired for permanent service. Currently both heaters are powered by temporary power cable.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 November 2010
Resolved 6 December 2010
Resolution: Water heaters hard wired.
Lifesaving › Lifebuoys › Serviceable
Issued 25 October 2010 Resolved
Shell of the vessel's life ring was worn & cracked, foam interior was water-logged. Informed owner of discrepancy. CG-835 issued.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 November 2010
Resolved 6 December 2010
Resolution: Life ring replaced.
Deck/Cargo › Mooring/Anchoring › Anchor Rope
Issued 5 November 2007 Resolved
Demonstrate ability of vessel anchoring system to secure vsl in case of emergency, to include making (1) anchor ready for releasing, for an average max water depth of 16 ft, 0 in. Using current anchors, vsl is required to have (2) anchors o/b ready to deploy. 46 cfr 184.300
Action required: 705 - Other - as specified
Due 5 December 2007
Resolved 28 November 2007
Resolution: witnessed successful testing of quick release anchoring equip.
Engineering › Steering Gear System › Hydraulic Hose
Issued 21 August 2006 Resolved
Replace hydraulic steering supply line from starboard hydraulic pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 September 2006
Resolved 18 September 2006
Resolution: 25 ft of hose replaced.
Personnel › Training › First Aid/CPR
Issued 21 August 2006 Resolved
Provide proof that 50 percent of assigned crewmembers have completed first aid/cpr training.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 September 2006
Resolved 18 September 2006
Resolution: Trng recd and certificates on hand.
Construction/Loadline › Hull › Hull Plating
Issued 21 August 2006 Resolved
Complete required annual hull assessment as required to remain in the AHE program.
Action required: 705 - Other - as specified
Due 21 September 2006
Resolved 18 September 2006
Resolution: Recd written report from Marine Safety Experts
Engineering › Pressure Vessel › Relief Valve
Issued 21 August 2006 Resolved
Make pressure vessel ready for inspection.
Action required: 705 - Other - as specified
Due 21 September 2006
Resolved 18 September 2006
Resolution: Pressure vsl opened and inspected sat. Recommended blasting and coating this winter.
Lifesaving › Hand Flares › Storage
Issued 21 August 2006 Resolved
Provide proper distress signal container and label as required.
Action required: 705 - Other - as specified
Due 21 September 2006
Resolved 18 September 2006
Resolution: Current cannister colored red and labeled.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 9 November 2005 Resolved
Post EAP information on vessel or near time clock.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 5 April 2006
Resolution: Sighted this date. [name withheld]
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 November 2005 Resolved
Renew all expired items in the vessels First Aid kit.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 5 April 2006
Resolution: Owner renewed kit. [name withheld]
Personnel › Training › Familiarization Training
Issued 9 November 2005 Resolved
Prior to Spring operations conduct MOB, and Fire drills.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 5 April 2006
Resolution: Witnessed sat drills. [name withheld]
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 8 November 2004 Resolved
Replace missing receptacle cover in galley
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 April 2005
Resolved 19 April 2005
Resolution: put cover on receptacle
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 8 November 2004 Resolved
Separate adult and children's life jackets 46 CFR 180.78
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 April 2005
Resolved 19 April 2005
Resolution: added wood barrier between adult and child jackets
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 8 November 2004 Resolved
Place proper donning placards for k-poc life jackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 April 2005
Resolved 19 April 2005
Resolution: Removed K-Poc Jackets
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 8 November 2004 Resolved
Replace waste receptacles with proper type. 46 CFR 177.405f
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 April 2005
Resolved 19 April 2005
Resolution: vessel purchased all steel trash cans
Electrical › Lighting (service) › Lighting Fixture
Issued 8 November 2004 Resolved
Replace missing light covers in storage compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 April 2005
Resolved 19 April 2005
Resolution: light covers were replaced with original covers.
Fire Fighting › Combustible Materials › Insulation
Issued 8 November 2004 Resolved
Remove polusturene insulation from hatch covers to engine room. High fire safety hazard.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 April 2005
Resolved 19 April 2005
Resolution: insulation was removed from cover
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 8 November 2004 Resolved
Adjust Gen Freq to 60 HZ.
Action required: 705 - Other - as specified
Due 5 April 2005
Resolved 19 April 2005
Resolution: Electrician adjusted speed.
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 8 November 2004 Resolved
Fix 2-3 amp ground when on shore-tie connection
Action required: 705 - Other - as specified
Due 5 April 2005
Resolved 19 April 2005
Resolution: Electrician found ground in shoretie connection, overhead light in the mens head, and a loose wire in the kitchen area. Re-checked ground faults and found non.
Engineering › Compressed Air System (control)
Issued 23 October 2003 Resolved
replace pressure relief valve on air receiver. LEGACY COMPONENT DESC: Valve
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 November 2003
Resolved 28 October 2003
Resolution: Witnesssed satisfactory test of relief valve. Valve lifted at 140 psi.
Accommodation/Occupational Safety
Issued 28 August 1997 Resolved
Prove proper operation of vessel's air compressor and air-powered whistle.
Condition: Unknown
Due 15 September 1997
Resolved 8 December 1997
Lifesaving
Issued 6 September 1996 Resolved
Install retroreflective tape on 1 ring life buoy.
Condition: Unknown
Due 25 September 1996
Resolved 25 September 1996
Lifesaving
Issued 6 September 1996 Resolved
Remove all flamable/combustible liquids (paints, oils, thinners, etc.) fromgalley storage area.
Condition: Unknown
Due 25 September 1996
Resolved 25 September 1996
Accommodation/Occupational Safety
Issued 6 September 1996 Resolved
Perform relief test on pressure vessel 150# relief valve in the presence ofa coast guard marine inspector.
Condition: Unknown
Due 6 September 1996
Resolved 6 September 1996
Documentation
Issued 6 September 1996 Resolved
Prove compliance with chemical testing requirements listed in 46 CFR 16 by not later than 04 NOV 96. Failure to prove compliance by this date will result in suspension of your vessel's Certificate of Inspection.
Condition: Unknown
Due 6 September 1996
Resolved 6 September 1996
Engineering
Issued 6 September 1996 Resolved
Prove proper operation of the vessel's remote fuel shutoff valve, in the presence of a marine inspector, not later than 31 OCT 96.
Condition: Unknown
Due 6 September 1996
Resolved 6 September 1996
Documentation
Issued 6 September 1996 Resolved
Complete documented vessel name change to "Pride of Oregon", as stated by master [name withheld], Jr., during 06SEP96 inspection for certification, or properly remark port bow, starboard bow and stern with currently documented name of "Rose of Rock River".
Condition: Unknown
Due 6 September 1996
Resolved 6 September 1996
Engineering
Issued 6 September 1996 Resolved
Repair exhaust lagging where deteriorated on both main engines.
Condition: Unknown
Due 6 September 1996
Resolved 6 September 1996
Electrical
Issued 6 September 1996 Resolved
Remove or properly install residential type lighting fixture in center maincabin (dining area) overhead.
Condition: Unknown
Due 25 September 1996
Resolved 25 September 1996
Lifesaving
Issued 6 September 1996 Resolved
Provide 3 approved handheld red flare distress signals and 3 handheld orange smoke distress signals.
Condition: Unknown
Due 25 September 1996
Resolved 25 September 1996
Engineering
Issued 6 September 1996 Resolved
Replace belt covers (guards) on both main engines.
Condition: Unknown
Due 25 September 1996
Resolved 25 September 1996
Navigation
Issued 29 August 1995 Resolved
Replace fractured bearing unit for STBD rudder post during drydock haulout but not later than 15NOV95.
Condition: Unknown
Due 21 September 1995
Resolved 21 September 1995
Documentation
Issued 29 August 1995 Resolved
Provide one copy of 46 CFR 166-199 (SubChapter T).
Condition: Unknown
Due 20 October 1995
Resolved 27 October 1995
Navigation
Issued 29 August 1995 Resolved
Replace all non-locking connections on steering system with locking type connections.
Condition: Unknown
Due 20 October 1995
Resolved 27 October 1995
Fire Fighting
Issued 20 September 1993 Resolved
Provide a serviceable B-I fire extinguisher for the pilot house.
Condition: Unknown
Due 20 September 1993
Resolved 20 September 1993
Lifesaving
Issued 20 September 1993 Resolved
Provide a serviceable ring buoy.
Condition: Unknown
Due 20 September 1993
Resolved 20 September 1993
Fire Fighting
Issued 31 August 1992 Resolved
PROVE PROPER OPERATION OF ELECTRIC FIRE PUMP.
Condition: Unknown
Due 31 August 1992
Resolved 31 August 1992
Lifesaving
Issued 16 September 1991 Resolved
MARK PFD STOWAGE SPACE, STBD SIDE, IN THE DINING ROOM, TO REFLECT THE NUMBER OF PFD'S ACTUALLY STOWED (51 VICE 52).
Condition: Unknown
Due 16 September 1991
Resolved 16 September 1991
Documentation
Issued 16 September 1991 Resolved
POST CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 16 September 1991
Resolved 16 September 1991
Documentation
Issued 1 October 1990 Resolved
POST STABILITY LETTER IN PILOTHOUSE.
Condition: Unknown
Due 1 October 1990
Resolved 1 October 1990
Unknown
Issued 1 October 1990 Resolved
PROVIDE 15 ADDITIONAL ADULT PFD'S AND 3 ADDITIONAL CHILD PFD'S TO COMPLY WITH REQUIRED NUMBER OF PFD'S ON THE CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 1 October 1990
Resolved 1 October 1990
Documentation
Issued 1 October 1990 Resolved
POST EMERGENCY CHECK OFF LIST.
Condition: Unknown
Due 1 October 1990
Resolved 1 October 1990
Lifesaving
Issued 1 October 1990 Resolved
MARK PFD STOWAGE BOX ON STARBOARD BOW TO SHOW TYPE AND QUANITY OF PFD'S STOWED WITHIN.
Condition: Unknown
Due 1 October 1990
Resolved 1 October 1990

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.