MAURY USCG vessel records
← All vessels

PRIDE OF OREGON

PRIDE OF OREGON is a 1989 passenger vessel (inspected). The Coast Guard has recorded 26 inspections since 2016, most recently in May 2026, along with 51 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 1 May 2026.

Built
1989
Last inspected
1 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 1 May 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

332803
Flag
UNITED STATES
Maury page id
psix-332803

Documentation record

Registered dimensions (L × B × D)64.8 ft × 32.0 ft × 5.0 ft
Registered tonnagegross 66 / net 52
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPALATKA SHIPBUILDING · PALATKA, FL, UNITED STATES · built 1989
Hull materialSteel
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portOREGON, IL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 2 January 2026 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it66 - Regulatory (Subpart C or D), Gross Ton
52 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 26

1 May 2026 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8358799
3 June 2025 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8151155
15 May 2025 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8136454
11 February 2025 Hull Examination
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8088165
14 May 2024 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7912425
5 October 2023 DAPI Audit · In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7804158
9 May 2023 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7684722
25 April 2023 Annual Inspection · In-Service Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7671486
21 February 2023 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7639548
4 April 2022 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7425272
28 March 2022 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7419719
24 May 2021 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7205607
15 April 2021 DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7175522
30 November 2020 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7103459
1 June 2020 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6967167
31 January 2020 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6900549
5 September 2019 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6804386
20 May 2019 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6689704
29 October 2018 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6570361
30 May 2018 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6428772
21 May 2018 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6420468
18 May 2018 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6417655
8 March 2018 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6368449
15 May 2017 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6147155
6 January 2017 Underwater Inspection in lieu of Drydock · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6067010
11 May 2016 DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5879507

Deficiency record · 51

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 May 2026 Resolved
Electrical equipment on a vessel must be installed and maintained to: (a) Provide services necessary for safety under normal and emergency conditions. Port and starboard running light wires are deteriorated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2026
Resolved 6 May 2026
Resolution: photos provided show lights were rewired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 May 2026 Resolved
Materials used in piping systems must meet the requirements of this subpart and be otherwise acceptable to the cognizant [name withheld] fluid piping for propulsion is missing support brackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2026
Resolved 6 May 2026
Resolution: photo of support provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 15 May 2025 Resolved
Each hatch cover must be attached to the hatch frame or coaming by captive chains, hinges, or other devices to prevent its loss. Install the same on the two bow hatches.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2025
Resolved 3 June 2025
Resolution: Chains installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 May 2025 Resolved
The bilge suctions shall be fitted with suitable strainers. The bilge strainer in the stern space is worn/corroded. Replace the same.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2025
Resolved 3 June 2025
Resolution: New Strainer installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 May 2024 Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: (ii) Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Monthly inspections are not being completed and logged.
Action required: 10 - Deficiency Rectified
Due 14 May 2024
Resolved 14 May 2024
Resolution: Discussed maintenance and logging requirements with crew. Crew completed maintenance in presence of inspector.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 14 May 2024 Resolved
Except as allowed by paragraphs (b) and (c) of this section, before getting underway on a voyage or as soon as practicable thereafter, the master of a vessel shall ensure that suitable public announcements are made informing all passengers of the following: (1) The location of emergency exits, survival craft embarkation areas, and ring life buoys; (2) The stowage location(s) of life jackets; (3) Either: (i) The proper method of donning and adjusting life jackets of the type(s) carried on the vessel including a demonstration of the proper donning of a lifejacket, or (ii) That passengers may contact a crew member for a demonstration as appropriate, prior to beginning an oceans or coastwise voyage; (4) The location of the instruction placards for life jackets and other lifesaving devices; (5) That all passengers will be required to don life jackets when possible hazardous conditions exist, as directed by the master; and (6) If the vessel is operating with reduced manning or equipment requirements in § 176.114 of this chapter. Passenger safety orientation was not being done at the beginning of each voyage.
Action required: 10 - Deficiency Rectified
Due 14 May 2024
Resolved 14 May 2024
Resolution: Master informed of requirement and will play safety orientation tape at the beginning of each voyage.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 14 May 2024 Resolved
A vessel with more than one passenger deck and a vessel with overnight accommodations must have the public address system operable from the operating station. Public address system inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 18 June 2024
Resolution: 18JUN2024: Received videos from [name withheld] showing the public address system is now operable.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 May 2024 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. First aid kit contents were expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 18 June 2024
Resolution: 18JUN2024: Received videos from [name withheld] showing a new first aid kit in onboard vessel.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 May 2024 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: (1) A space with a through-hull fitting below the deepest load waterline, such as a lazarette; (2) A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space. No audible alarm at operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2024
Resolved 18 June 2024
Resolution: 18JUN2024: Received videos from [name withheld] showing the bilge alarm at operating station has audible and visual indication of high water level.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 May 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to: (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Light near female head is missing guard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2024
Resolved 18 June 2024
Resolution: 18JUN2024: Received videos from [name withheld] showing the light fixture near female head has new guard in place.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 10 October 2023 Resolved
Master has informed USCG that there are watertight integrity issues in isolated area of upper deck above aft bar overhead lights. Master has also informed that temp repairs have been made. Vessel shall make permanent repairs to affected area by the end of next Alternate Hull Examination.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 May 2024
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 10 October 2023 Resolved
Vessel has growth in water tank. Perform tank cleaning and flush prior to serving potable water via tank to passengers.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2023
Resolved 15 May 2024
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 10 October 2023 Resolved
03-Develop a written drug and alcohol testing program.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2023
Resolved 14 May 2024
Resolution: Vessel management has developed and implemented a written drug and alcohol testing program.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 10 October 2023 Resolved
-Develop a Employee assistance program which includes the training and education required in 46 CFR 16.401
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2023
Resolved 14 May 2024
Resolution: Vessel management has developed and implemented an employee assistance program which includes the training and education required in 46 CFR 16.401.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 5 October 2023 Resolved
Provide positive test result for [name withheld] as discussed.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2023
Resolved 14 May 2024
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 April 2023 Resolved
Engine room fire station hose is too short at 23'. Replace with proper length.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2023
Resolution: Proper length hose installed on vessel.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 25 April 2023 Resolved
Items in First aid kit expired, replace with new.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 May 2023
Resolution: Expired items replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 25 April 2023 Resolved
Life ring needs to be labeled with vessel name.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2023
Resolution: Life ring is labeled properly
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 25 April 2023 Resolved
Vessel needs to be identified from outside of vessel. Name of vessel on Bow/Stern. Homport of vessel on Stern.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2023
Resolution: Vessel added name plates.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 April 2023 Resolved
Conduct monthly inspection of vessel Fire extinguishers
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 9 May 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 April 2023 Resolved
Remove any combustible materials from from engine room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2023
Resolution: Engine room cleared of materials
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 4 April 2022 Resolved
Missing Belt guard on genset, re-install properly.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 April 2022 Resolved
Missing hardware on 110v panel near main switchboard. install proper screws.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 April 2022
Resolution: Hardware installed properly
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 April 2022 Resolved
Remove excess water from batteries and inside boxes. Batteries appear to be overfilled.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 April 2022 Resolved
Replace hoses on Steering Ram.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 April 2022
Resolution: Hoses were replaced with new.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 April 2022 Resolved
Provide proper DAPI program elements, training, random testing, records, pre-elployment and members enrolled.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 April 2022 Resolved
Upper deck life ring needs new line. Replace line or entire ring.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 April 2022
Resolution: Life rings were replaced with new
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 4 April 2022 Resolved
No. 1 fire station piping has leak where piping meets main deck. Conduct proper repair. This fire station needs proper labeling.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2022
Resolution: Video Provided.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 4 April 2022 Resolved
Remove all plastic waste recepticales from vessel and replace with non-combustible material.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2023
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 4 April 2022 Resolved
Provide proof the vessels PA system functions on all deck
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 April 2022
Resolution: Video sent by master showing proper operation of PA.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 May 2021 Resolved
The sanitary pump that delivers river water to toilets for flushing is inoperable. Repair/replace sanitary pump located in lazarette and test. Supply local OCMI with pump replacement nomenclature/details and test repair prior to using sanitary system/toilets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2021
Resolved 24 May 2021
Resolution: Sanitary pump replaced by Ehmen Industries Inc.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 3 May 2021 Resolved
Vessel is required to have 3 red flares and 3 orange smoke or 6 red flare day/night for river route service. Vessel only has 4 for inspection. Meet above requirement to satisfaction of Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2021
Resolved 24 May 2021
Resolution: Vessel purchased additional flares to meet route and condition.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 May 2021 Resolved
Ensure that hull gauging for annual condition assessment are completed to fulfill inspection conducted and reported on 15APR2021 to the satisfaction of Marine Inspector.
Action required: 705 - Other - as specified
Due 30 June 2021
Resolved 30 June 2021
Resolution: Hull gauging complete, reviewed, and filed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 May 2021 Resolved
One (1) child life jacket not servicable. Restricted to 14 children until extra life jacket restored. COI requires 15 child life jacket (10%) of total passengers allowed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2021
Resolved 24 May 2021
Resolution: Vessel purchased Tpye 1 USCG approved child life jacket to meet 10% of total passengers allowed.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 3 May 2021 Resolved
Vessel hydraulic hoses for steering and propulsion on the exterior are deteriorated/rotted. Both rudder exterior hoses shall be replaced. Port and starboard propulsion sides have three (3) hoses each that shall be replaced. Hoses must meet SAE J-1942 and hose end fittings must meet SAE J-1945. Complete for next annual inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 June 2021
Resolution: Hoses were replaced with 8M3K and 12M3K GATES and are present on SAE International J1942 listing.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 June 2020 Resolved
Provide evidence that MIS data collection form is submitted to Commandant by either mail or internet as per 46 CFR 16.500(b) to satisfaction of Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2020
Resolved 3 May 2021
Resolution: Vessel proved through mail receipt that annual MIS report was sent to DOT address as per CFR regulation site 46CFR16.500.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 June 2020 Resolved
Replace broken paddle board on starboard paddle wheel to satisfaction of Marine Inspector. Believed damage from ice season, vessel not pulled out during. 46 CFR M176.25-5 "Old T"
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 3 July 2020
Resolution: Broken paddle was replaced to the satisfaction of attending Marine Inspector.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 June 2020 Resolved
Ensure vessel air receiver system is ready to operate vessel whistle. Prove whistle can operate to satisfaction of Marine Inspector and prior to carriage of passengers. 46 CFR 176.30-1 "Old T"
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 3 July 2020
Resolution: Vessel whistle has been proven to the satisfaction of attending Marine Inspector.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 20 May 2019 Resolved
Provide list of employees in the drug and alcohal program
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2019
Resolved 5 September 2019
Resolution: Provide crew list for DAOI program
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 20 May 2019 Resolved
Provide up to date MIS report
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2019
Resolved 5 September 2019
Resolution: Received updated MIS report
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 May 2019 Resolved
Replace Ring Buoy with approved type
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2019
Resolved 5 September 2019
Resolution: New ring bouy was installed
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 20 May 2019 Resolved
Provide Local Notice to Mariners, Rules of the Road, Coast Pilot
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2019
Resolved 5 September 2019
Resolution: All publications on board vessel
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 20 May 2019 Resolved
Replace fire hose with non kinking type
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2019
Resolved 5 September 2019
Resolution: replace firehose with non-kinking hose
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 May 2019 Resolved
Provide up to date first aid kit
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2019
Resolved 5 September 2019
Resolution: first aid kit equipment has been renewed
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 20 May 2019 Resolved
Updated Chart for area of operation
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2019
Resolved 5 September 2019
Resolution: new chart was purchased
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 20 May 2019 Resolved
repair or replace broken doors in bar area
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2019
Resolved 5 September 2019
Resolution: door was removed and not replace due to no carpenter skills
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 21 May 2018 Resolved
Provide DAPI Info with MIS Report
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2019
Resolved 5 September 2019
Resolution: cleared prior to 2019 operating season
Lifesaving › Hand Flares › Quantity
Issued 21 May 2018 Resolved
Provide correct amount of Flares (6) Had 4 on board.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2018
Resolved 29 October 2018
Resolution: Received photo of flares
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 21 May 2018 Resolved
vessel had 150 adult lifejackets on board, vessels COI has 162 persons listed. vessel is 12 typeone lifejackets short. Reduced Passanger count to 138 pass.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 May 2018
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 21 May 2018 Resolved
Update emergency procedures. Procedures list lifefloats, no safety harness for crew during MOB.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2018
Resolved 29 October 2018
Resolution: Received updated procedures
Lifesaving › Lifebuoys › Serviceable
Issued 21 May 2018 Resolved
Replace lifebuoys. grab line disintegrated when twisted, multiple tears in ring.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2018
Resolved 29 October 2018
Resolution: New Ring Buoy has been installed

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.