Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
259 - Simplified, Gross Ton
259 - Simplified, Net Ton
Maury page id
psix-3329
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 34
18 May 2026Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8375385
11 March 2026Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8324505
27 January 2026Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8302218
29 July 2025Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8197755
2 April 2025Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8104389
28 June 2024Drydock Exam · Internal Structural Exam · Deficiency Check · Cargo Tank Internal · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7931799
28 April 2020Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6945085
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 4 September 2024Resolved
Except as provided in paragraph (d) of this section, no person may use any equipment listed in paragraph (c) of this section for transfer operations unless the vessel operator, tests and inspects the equipment in accordance with paragraphs (b), (c) and (f) of this section and the equipment is in the condition specified in paragraph (c) of this section. Each nonmetallic transfer hose must: Not burst, bulge, leak, or abnormally distort under static liquid pressure at least 1.5 times the maximum allowable working pressure. Vessel must conduct a hydrostatic test of the nonmetallic transfer hose.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2024
Resolution: Pipeline hydrostatically tested, all sat. New cargo system pressure gauged installed.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 4 September 2024Resolved
Except as provided in paragraph (d) of this section, no person may use any equipment listed in paragraph (c) of this section for transfer operations unless the vessel operator, tests and inspects the equipment in accordance with paragraphs (b), (c) and (f) of this section and the equipment is in the condition specified in paragraph (c) of this section. Each loading arm and each transfer pipe system, including each metallic hose, must not leak under static liquid pressure at least 1.5 times the maximum allowable working pressure. Vessel must conduct a hydrostatic test of the cargo piping.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2024
Resolution: Barge transfer hose hydrostatically tested. all sat.