Built
1989
Last inspected
17 September 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 17 September 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WAE8029
332934
Flag
UNITED STATES
Maury page id
psix-332934

Documentation record

Registered dimensions (L × B × D)40.0 ft × 12.0 ft × 4.5 ft
Registered tonnagegross 18 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderB & M METAL PRODUCTS · CLARKSTON, WA, UNITED STATES · built 1989
Hull materialAluminum
PropulsionJet Drive
Hull shapeBox
Hull configurationMonohull
Hailing portVALDEZ, AK
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 12 August 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it18 - Simplified, Gross Ton
14 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 23

17 September 2025 Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 8235698
19 February 2025 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 8081637
9 September 2024 Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7999619
8 July 2024 Drydock Exam
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7953538
8 June 2023 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7710107
24 April 2023 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7676458
18 July 2022 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7510190
19 April 2022 Drydock Exam
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7434300
10 November 2021 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7351528
26 October 2021 Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7341486
13 November 2020 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7099249
16 October 2020 Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7081754
26 May 2020 Drydock Exam
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6962985
13 September 2019 Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6815055
22 May 2019 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6697127
31 July 2018 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6498419
29 May 2018 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6430494
26 April 2018 Drydock Exam
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6399888
9 June 2017 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6175775
16 May 2017 COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6154396
28 July 2016 Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 5956146
1 June 2016 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 5899574
19 April 2016 Drydock Exam
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 5857766

Deficiency record · 30

01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 9 September 2024 Resolved
Licensees of radio stations are required to have current station documents. Vessels Safe Radiotelephony Cert is expired. 47 CFR 80.401
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2024
Resolved 19 February 2025
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 9 September 2024 Resolved
Vessel is required to have a med kit in accordance with 46 CFR 160.041. Vessel's med kit was found to contain expired items. 46 CFR 160.041
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2024
Resolved 15 October 2024
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 September 2024 Resolved
All vessel's must have navigation lights that are in compliance with applicable section of the International and Inland Navigation Rules. Vessel's anchor light is non operational.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2024
Resolved 15 October 2024
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 September 2024 Resolved
Vessels less that 20 meters in length, shall have a sound producing device with a audible range of .5 miles. The vessels horn is non operational. 33 CFR 86.01(c)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2024
Resolved 15 October 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 September 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew and hte vessel from electrical hazards. Main conning position was missing 02 switch/ fuse cover plates. 46 CFR 183.200
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2024
Resolved 15 October 2024
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 8 June 2023 Resolved
Found cracks on hull stiffeners. Repair marked welds.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2023
Resolved 11 July 2023
Resolution: Wields were repaired.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 27 July 2022 Resolved
Submit repair proposal to permanently repair crack in gunwale in way of port house corner. Permanent repair to be completed by 27 Sep 22 or prior to carrying passengers or cargo after this date.
Action required: 705 - Other - as specified
Due 27 September 2022
Resolved 24 April 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 July 2022 Resolved
Port engine control cable damaged. Demonstrate proper control of port engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 July 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 October 2021 Resolved
Repair leak in forward bilge pump hose. 46 CFR 182.25-10(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2021
Resolved 10 November 2021
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 26 October 2021 Resolved
Steering gear ram moves due to crack on ram mount. Repair cracked weld.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2021
Resolved 10 November 2021
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 26 October 2021 Resolved
Repair marked cracked welds in forward section.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2021
Resolved 10 November 2021
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 16 October 2020 Resolved
Repair crack on rail in way of forward port house.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2020
Resolved 26 October 2021
Resolution: Owner repaired crack without notifying CG.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 16 October 2020 Resolved
Make openings in the engine room watertight bulkhead have means to make them water tight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2020
Resolved 13 November 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 October 2020 Resolved
Provide hand bilge pump for engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2020
Resolved 13 November 2020
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 13 September 2019 Resolved
Provide required charts and nautical publications.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2019
Resolved 30 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 September 2019 Resolved
Prove proper operation port engine room and throttle cable.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 September 2019
Resolved 30 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 September 2019 Resolved
Provide hand bilge pump for engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2019
Resolved 30 September 2019
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 31 July 2018 Resolved
Replace port raw water intake hose IWO stern. 46 CFR 182.720
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2018
Resolved 31 August 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 July 2018 Resolved
Prove operation of engine room bilge pump. 46 CFR 176.804 (h)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2018
Resolved 31 August 2018
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 31 July 2018 Resolved
Repair cracked welds in forward section. 46 CFR 176.802
Action required: 705 - Other - as specified
Due 30 October 2018
Resolved 22 May 2019
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 31 July 2018 Resolved
Verify all wires are properly terminated. 46 CFR 183.310
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2018
Resolved 31 August 2018
Construction/Loadline › Structures › Deck Plating
Issued 29 May 2018 Resolved
Submit repair proposal to permanently repair welded over crack in way of stb aft house corner. Permanent repair to be completed by 01 Oct 18 or prior to carrying passengers or cargo after this date.
Action required: 705 - Other - as specified
Due 1 October 2018
Resolved 22 May 2019
Construction/Loadline › Hull › Weld
Issued 26 April 2018 Resolved
Repair two welds in the aft corners, port and stbd, in the engine room.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 June 2018
Resolved 29 May 2018
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 16 May 2017 Resolved
Install flame screen on fuel vent. 46 CRF 182.450(e)
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 9 June 2017
Communications › Alarms/Indicators › Bilge Alarm
Issued 16 May 2017 Resolved
Make bilge high level alarm work. 46 CFR 182.530
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 9 June 2017
Engineering › Bilge Water Management System › Not Operational
Issued 16 May 2017 Resolved
Provide hand bilge pump capable of reaching the bilge of each watertight compartment and discharging overboard. 46 CFR 182.520(b)(2)
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 9 June 2017
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 16 May 2017 Resolved
Reinstall conducting wire on fuel fill. 46 CFR 182.445(g)
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 9 June 2017
Engineering › Bilge Water Management System › Pump
Issued 29 July 2016 Resolved
Secure both bilge pumps
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 17 August 2016
Construction/Loadline › Hull › Stringer
Issued 19 April 2016 Resolved
Repair crack on 3 port stringer 5 feet from bow. 46 CRF 176.700
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 23 June 2016
Construction/Loadline › Structures › Machinery Space Opening
Issued 19 April 2016 Resolved
Seal forward top corner of engine room. 46 CFR 179.320
Action required: 705 - Other - as specified
Due 3 May 2016
Resolved 1 June 2016

Ownership record