Records from 1989 to 2026. Most recent: inspection, 31 March 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 56
31 March 2026
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8311695
24 March 2026
Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8311663
8 May 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8129682
9 April 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7892470
26 March 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7885320
3 April 2023
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7661733
4 April 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7422025
15 March 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7392605
26 May 2021
Type not recorded
No type recorded · Station Manasquan Inlet · USCG East District (CGD-E) · Activity 7208878
1 April 2021
COI Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7160927
13 April 2020
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6938592
27 March 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6932155
14 May 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6684248
19 March 2018
Administrative Inspection · Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6372377
3 May 2017
Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6134752
2 May 2016
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5883205
25 March 2016
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5840730
15 May 2014
Administrative Inspection · DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4859737
8 August 2011
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4109077
20 April 2009
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3456641
14 May 2008
Annual Inspection · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3213350
11 April 2007
COI Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2924980
11 April 2006
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2627084
12 May 2005
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2352864
22 March 2005
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2317039
4 October 2004
Type not recorded
No type recorded · Station St Inigoes · USCG East District (CGD-E) · Activity 2213940
15 June 2004
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2097829
9 June 2003
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1812885
28 March 2003
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1768367
17 April 2002
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1604974
19 April 2001
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1452795
9 March 2001
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1376510
18 April 2000
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1418747
25 May 1999
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 799226
21 April 1999
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1124448
26 March 1999
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 782747
27 July 1998
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 795022
20 May 1998
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1126044
17 September 1997
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 777166
29 August 1997
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1123452
22 April 1997
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1378024
1 May 1996
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1402246
1 February 1996
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 884188
19 April 1995
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 861637
10 August 1994
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 863155
22 April 1994
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1170913
4 February 1993
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1401673
16 January 1993
Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1132888
10 May 1992
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 942450
22 April 1992
Deficiency Check · Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 942449
23 April 1991
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1246846
18 January 1991
Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1238993
25 May 1990
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 934926
2 March 1990
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 901314
22 February 1990
Initial Certification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1229081
30 August 1989
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 931628
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 8 May 2025
Resolved
Vessels operating on a cold water Limited Coastwise route must have Life Floats provided for 100% of persons onboard. 22 person Life Float hand grab and basket webbing was wasted in several locations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 May 2025
Resolution: 22 Person Life float installed with all required equipment and accessories for route and service.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 9 April 2024
Resolved
After loading and prior to departure and at all other times necessary to assure the safety of the vessel, the master shall determine that the vessel complies with all applicable stability requirements in the vessel's stability letter and Certificate of Inspection. The vessel may not depart until it is in compliance with these requirements. Vessel's freeing ports have installed closure devices preventing rapid clearing of water from the deck. Remove closure devices to the satisfaction of Marine Inspector (MI) prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2024
Resolution: Verified closure devices were removed from freeing ports/scuppers.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 9 April 2024
Resolved
Each hatch exposed to the weather must be watertight; except that, the following hatches may be weathertight:
(1) Each hatch on a watertight trunk that extends at least 12 inches (30.5 centimeters) above the weather deck. Portions of the coamings around engine trunk have been removed for engine maintenance. Repair/replace coamings to satisfaction of MI prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2024
Resolution: Verified engine trunk cutouts were reinstalled.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 9 April 2024
Resolved
Each hatch exposed to the weather must be watertight. Port side watertight hatch for the line locker on the bow has a hole drilled through. Repair/replace hatch to satisfaction of MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2024
Resolved 18 April 2024
Resolution: Verified new watertight hatch installed.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 9 April 2024
Resolved
A pre-engineered fixed gas fire extinguishing system must: Be capable of manual actuation from outside the space in addition to automatic actuation by a heat detector. Vessel's fireboy system had safety pin installed preventing remote activation. Crew removed safety pin and left system fully operational.
Action required: 10 - Deficiency Rectified
Resolved 9 April 2024
Resolution: Crew removed safety pin and left system fully operational.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 April 2024
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Vessel had unsecured, portable fuel can in bilge forward of engine room. Crew removed portable fuel can.
Action required: 10 - Deficiency Rectified
Resolved 9 April 2024
Resolution: Crew removed portable fuel can.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 April 2023
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers...The lower bilge pump in the engine compartment was inoperable. Send a video of the identified bilge pump operating.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2023
Resolved 4 April 2023
Resolution: Vsl POC sent a video of the bilge pump operating. All satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 3 April 2023
Resolved
Each life float must be fitted with...two paddles...The life float onboard did not have paddles. Send a picture of two properly marked and secured paddles to the vessel's life float.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2023
Resolved 4 April 2023
Resolution: Vsl POC sent a picture of the 02 lifefloat paddles with the vessel's name. All satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 April 2023
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required by Table 181.500(b) and other provisions of this section. Space: Machinery Space, Minimum required rating: 40-B:C, Quantity and location: 1 in the vicinity of the exit. There was not a portable fire extinguisher designated for the engine room onboard at the time of inspection. Send a picture of the portable fire extinguisher for the engine room properly stowed on the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2023
Resolved 11 May 2023
Resolution: Vessel purchased and installed a 4A:80B:C for engine room.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 4 April 2022
Resolved
When operating a vessel on a body of water where the discharge of untreated sewage is prohibited, the operator must secure the MSD, which prevents discharge of sewage by acceptable methods. Noticed the overboard discharge valve for the MSD was not secured properly. Properly secure overboard sewage value to the satisfactory of the attending marine inspector. 33 CFR 159.7
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2022
Resolved 12 April 2022
Resolution: Operator provided photo of sewage handle locked with chain and padlock.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 4 April 2022
Resolved
Each life float and buoyant apparatus must be stowed with a float free link required by 180.130(a)(1) of proper strength for the size of the life float or buoyant apparatus as indicated on its identification tag. Life float weak link did not have a tag stating information required by 46 CFR 160.073-20. Replace weak link tag to the satisfaction of the attending marine inspector. 46 CFR 180.137(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2022
Resolved 12 April 2022
Resolution: O/O provided photo of proper weak link, sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 4 April 2022
Resolved
A vessel must carry one floating water light, unless it is limited to daytime operation, which case no floating water light is required. The required floating water light attached to the ring buoy was not working. Repair or replace water light on the ring buoy to the satisfaction of the attending marine inspector. 46 CFR 180.70(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2022
Resolved 12 April 2022
Resolution: Operator provided video of floating light operating properly.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 1 April 2021
Resolved
EMERGENCY FUEL SHUTOFF VALVE FOR GENERATOR IS INOPERABLE. REPAIR OR REPLACE TO SATISFACTION OF MARINE INSPECTOR. DUE APRIL 15, 2021. 46 CFR "OLD T" 180.20-40(b)(3)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2021
Resolved 8 April 2021
Resolution: O/O replaced valve. [name withheld] and [name withheld] witnessed proper operation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 April 2021
Resolved
RETRO REFLECTIVE TAPE ON LIFE JACKETS IS FADED. REPLACE RETRO REFLECTIVE TAPE TO THE SATISFACTION OF MARINE INSPECTOR. DUE APRIL 15, 2021 46 CFR 180.72
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2021
Resolved 8 April 2021
Resolution: [name withheld] and Klimo attended vessel and saw that new retro reflective tape had been put on all the lifejackets.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 May 2019
Resolved
Prove proper operation of all visual bilge alarms for each space independently.
46 CFR 182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 May 2019
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 15 May 2019
Resolved
Seal holes near tops of bulkheads between laz and engine room and between engine room and space containing fuel shut off valves.
46 CFR 179.320
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 May 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 May 2019
Resolved
Provide third 2 1/2 gallon fire bucket.
46 CFR 181.610
Action required: 10 - Deficiency Rectified
Resolved 15 May 2019
Navigation › Piloting/Steering › Marine Charts
Issued 3 May 2017
Resolved
Vessel owner/operator must get current/corrected and up to date charts. (2014)
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 17 May 2017
Resolution: Vessel submitted pictures of new charts.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 May 2016
Resolved
EKO01 Provide first aid kit meeting the requirements of 46CFR160.041
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 15 May 2016
Resolution: Received photo via email of new first aid kit. Deficiency cleared.
Navigation › Piloting/Steering › US Coast Pilot
Issued 2 May 2016
Resolved
EKO02 Provide current Light List and Coast Pilot
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 15 May 2016
Resolution: Received photo via email of new Light List and Coast Pilot. Deficiency cleared.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 2 May 2016
Resolved
EKO03 Provide most recent management information system (MIS) report from drug consortium.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 15 May 2016
Resolution: Received photo via email of current MIS submission report from Maritime Consortium. Deficiency cleared.
Fire Fighting › Ventilation Systems › Ducts
Issued 15 May 2014
Resolved
There is no way to secure the exterior ventillation to the engine room. Provide ventillation port covers.
Condition: Improper/Lack of Maintenance
Due 2 June 2014
Resolved 23 May 2014
Resolution: Ventillation plugs were fabricated by the crew.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 15 May 2014
Resolved
Donning placard for the life jackets onboard was not the correct type.
Condition: Improper Installation
Due 2 June 2014
Resolved 23 May 2014
Resolution: A proper placard for donning life jackets was posted.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 15 May 2014
Resolved
Master of vessel did not have his license onboard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2014
Resolution: Mater had his license onboard for MOB drills and Fire drill with underway check ride.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 15 May 2014
Resolved
EAP policy was not onboard the vessel.
Condition: Improper/Lack of Maintenance
Due 2 June 2014
Resolved 23 May 2014
Resolution: EAP letter was onboard the vessel.
Operations/Management › Drills/Instruction › Not Conducted
Issued 15 May 2014
Resolved
Due to a lack of mariners license onboard, MOB and Fire Drill must be conducted in the presence of a CG Marine Inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2014
Resolution: MOB and Fire drill conducted with CG Marine Inspector.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 15 May 2014
Resolved
A 60 ft, 5/16inch line must be attached to the life ring.
Condition: Improper/Lack of Maintenance
Due 2 June 2014
Resolved 23 May 2014
Resolution: Line properly attached to life ring.
Lifesaving › Lifefloat › Retroreflective Material
Issued 15 May 2014
Resolved
Retro-reflective tape was missing on the underside of the life floats.
Condition: Improper/Lack of Maintenance
Due 2 June 2014
Resolved 23 May 2014
Resolution: Retro tape properly applied to the bottom of the life float.
Electrical › Electrical Distribution System (service) › Cable
Issued 15 May 2014
Resolved
Replace solid core wire with CG approved marine grade wire in galley.
Condition: Improper Installation
Due 2 June 2014
Resolved 23 May 2014
Resolution: Galley wire was replaced with CG approved marine grade wire.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 April 2009
Resolved
Nav Lights on the vessel were significantly worn and crazzed. Stbd, Masthead, and Anchor Light all need to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2009
Resolution: Owner provided reciepts for the purchase of new nav lights.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 20 April 2009
Resolved
Lifefloat had wasted reflective tape. O/Op must replace reflective tape for proper operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2009
Resolution: Owner provided reciepts for purchase of new reflective tape from West Marine.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 11 April 2006
Resolved
Provide auto shut down of generator upon activation of fixed fire extinguishing system in engine room.
Due 11 May 2006
Resolved 13 April 2006
Resolution: generator wired to shut down upon system activation.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 22 March 2005
Resolved
Complete DDX prior to carrying passengers
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2005
Resolved 12 May 2005
Resolution: Completed DDX.
Construction/Loadline › Hull › Bottom Plating
Issued 22 March 2005
Resolved
Complete DDX prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2005
Resolved 12 May 2005
Resolution: Completed DDX.
Communications › Alarms/Indicators
Issued 9 June 2003
Resolved
LABEL BILGE HIGH WATER ALARMS AT OPERATING STATION. LEGACY COMPONENT DESC: High Water Alarm
Action required: 705 - Other - as specified
Due 9 July 2003
Resolved 10 June 2003
Navigation › Piloting/Steering › Marine Charts
Issued 17 April 2002
Resolved
PROVIDE UP TO DATE CHARTS OF OPERATING AREA.
Due 16 May 2002
Resolved 26 April 2002
Engineering
Issued 19 April 2001
Resolved
REPAIR GENERATOR RACOR FUEL FILTER.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Engineering
Issued 19 April 2001
Resolved
PROVIDE DOUBLE CLAMPS ON FUEL HOSES.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Engineering
Issued 9 March 2001
Resolved
RENEW CUTLESS BEARINGS.
Condition: Unknown
Due 9 March 2001
Resolved 9 March 2001
Electrical
Issued 21 April 1999
Resolved
Prove operation of generator.
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Lifesaving
Issued 21 April 1999
Resolved
Replace oudated aspirin, eye wash & Chlo-amine from first aid kit.
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Navigation
Issued 21 April 1999
Resolved
Provide charts for op area.
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Lifesaving
Issued 21 April 1999
Resolved
Prove operation of life ring light prior to carrying passengers.
Condition: Unknown
Due 15 May 1999
Resolved 24 April 1999
Construction/Loadline
Issued 21 April 1999
Resolved
Prove operation of bilge alarm system.
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Lifesaving
Issued 21 April 1999
Resolved
Prove drug testing program prior to carrying passengers.
Condition: Unknown
Due 15 May 1999
Resolved 24 April 1999
Fire Fighting
Issued 21 April 1999
Resolved
Provide means to close off engine compartment ventilation.
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Accommodation/Occupational Safety
Issued 26 March 1999
Resolved
REPAIR MSD PRIOR TO SAILING.
Condition: Unknown
Due 26 March 1999
Resolved 26 March 1999
Electrical
Issued 26 March 1999
Resolved
REPAIR GENERATOR EXHAUST PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 26 March 1999
Resolved 26 March 1999
Engineering
Issued 20 May 1998
Resolved
Install fuel hose that meets SAE J1942 standard.
Condition: Unknown
Due 20 May 1998
Resolved 20 May 1998
Fire Fighting
Issued 20 May 1998
Resolved
Prove ops of fixed CO2 system eng shutdown.
Condition: Unknown
Due 20 May 1998
Resolved 20 May 1998
Construction/Loadline
Issued 17 September 1997
Resolved
Install a thru hull fitting that meets or exceeds hul strength.
Condition: Unknown
Due 17 September 1997
Resolved 17 September 1997
Construction/Loadline
Issued 17 September 1997
Resolved
Install ovbd disch valve for hatch drains.
Condition: Unknown
Due 17 September 1997
Resolved 17 September 1997
Fire Fighting
Issued 22 April 1997
Resolved
COMPLETE INSTALLATION OF FIXED FIRE SYSTEM IN ENGINE COMPARTMENT. MUST KEEP AN ADDITIONAL B-II ON BOARD NEAR ENGINE COMP. UNTIL SYSTEM COMPLETELY INSTALLED.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Documentation
Issued 1 May 1996
Resolved
POST EMERGENCY BROADCAST PLACARD NEAR RADIO.
Condition: Unknown
Due 14 May 1996
Resolved 30 July 1996
Lifesaving
Issued 1 May 1996
Resolved
REPLACE PAINTER LINE ON RING BUOY.
Condition: Unknown
Due 14 May 1996
Resolved 30 July 1996
Lifesaving
Issued 1 May 1996
Resolved
ATTACH RETROREFLECTIVE TAPE ON BOTH SIDES OF RING BUOY.
Condition: Unknown
Due 14 May 1996
Resolved 30 July 1996
Lifesaving
Issued 1 May 1996
Resolved
MARK FLARE BOX WITH "DISTRESS SIGNALS" IN 1/2" LETTERS.
Condition: Unknown
Due 14 May 1996
Resolved 30 July 1996
Lifesaving
Issued 1 May 1996
Resolved
POST OR MAKE AVAILABLE LIFE JACKET DONNING PLACARDS FOR BOTH JACKET AND "HORSE COLLAR" TYPE PFD'S.
Condition: Unknown
Due 14 May 1996
Resolved 30 July 1996
Electrical
Issued 23 April 1991
Resolved
DEMONSTRATE OPERATION OF AMMETER.
Condition: Unknown
Due 23 April 1991
Resolved 23 April 1991
Electrical
Issued 23 April 1991
Resolved
SHORE BATTERY TO MINIMIZE MOVEMENT.
Condition: Unknown
Due 23 April 1991
Resolved 23 April 1991
Electrical
Issued 23 April 1991
Resolved
PROVIDE METALIC HANGERS FOR ELECTRICAL WIRING TO PROVIDE RUNS OF NOT MORE THAN 24".
Condition: Unknown
Due 23 April 1991
Resolved 23 April 1991
Construction/Loadline
Issued 25 May 1990
Resolved
COMPLETE INSTALLATION OF THE BULKHEAD, DOOR AND CURTAINS TO REDUCE YOUR DECK LENGTH TO LESS THAN 50% OF THE VESSELS OVERALL LENGTH
Condition: Unknown
Due 25 May 1990
Resolved 25 May 1990