MAURY USCG vessel records Sign in
← All vessels

ERAWAN

ERAWAN is a 1982 freight ship. The Coast Guard has recorded 15 inspections since 1989, most recently in July 1999, along with 15 deficiencies — 3 with no resolution recorded —.

Records from 1989 to 1999. Most recent: inspection, 12 July 1999.

Built
1982
Last inspected
12 July 1999
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8100997 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
333658
Flag
UNITED KINGDOM
—
Maury page id
psix-333658

Inspections, by type

…with no type recorded15
…past their stated due date3
Years with a record 11 calendar years (1989–1999)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 27 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it35716 - Regulatory (Subpart C or D), Gross Ton
20830 - Regulatory (Subpart C or D), Net Ton
64643 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 15

12 July 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 430578
22 June 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 416952
17 June 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 417239
9 December 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 410425
10 December 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 398125
1 April 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 389676
20 October 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 383758
3 March 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 364891
22 July 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 472880
7 December 1992 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 669221
6 December 1992 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 354926
3 May 1991 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 343551
4 December 1990 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 340698
19 April 1990 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 336515
29 June 1989 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 331346

Deficiency record · 15

Electrical
Issued 12 July 1999 No resolution recorded
MAKE PERMANENT REPAIR TO SOFT PATCH ON OUTLET PIPE FOR AUX F/W COOLER FOR DIESEL GEN. TO STA OF CLASS
Condition: Unknown
Due 12 July 1999 — due date passed with no resolution recorded
Engineering
Issued 12 July 1999 No resolution recorded
MAKE PERM. REPAIRS TO F/O LEAK ON # 5 MAIN ENGINE_x001C_ CYL AND REPLACE MISSING SPRAY SHEILD ON # 6, 7 CYLS.
Condition: Unknown
Due 12 July 1999 — due date passed with no resolution recorded
Construction/Loadline
Issued 12 July 1999 No resolution recorded
REPAIR OR REPLACE WATER TIGHT DOOR TO EMERGENCY BATTERY ROOM TO SAT OF CLASS
Condition: Unknown
Due 12 July 1999 — due date passed with no resolution recorded
Electrical
Issued 17 June 1998 Resolved
RENEW AS ORIGINAL SEA WATER OUTLET PIPING FROM GENERATOR L.O. COOLER. SOLAS 74(AMENDED) I/11 (a).
Condition: Unknown
Due 12 July 1999
Resolved 12 July 1999
Fire Fighting
Issued 17 June 1998 Resolved
RENEW AS ORIGINAL DETERIORATED FIREMAIN PIPING BETWEEN CARGO HOLDS 2 AND 3,3 AND 4, AND 6 AND 7. SOLAS 74(AMENDED) REG II-2/21.
Condition: Unknown
Due 12 July 1999
Resolved 12 July 1999
Fire Fighting
Issued 17 June 1998 Resolved
RENEW AS ORIGINAL ALL TEMPORARY PATCHES ON FIREMAIN PIPING. SOLAS 74(AMENDED) REG II-2/21.
Condition: Unknown
Due 12 July 1999
Resolved 12 July 1999
Unknown
Issued 9 December 1997 Resolved
FIREMAIN PIPING WASTED/HOLED MAIN DECK STARBOARD FORWARD OF #7 HOLD. (SOLAS74 (AMEND) II-2/21)
Condition: Unknown
Due 26 June 1998
Resolved 26 June 1998
Unknown
Issued 9 December 1997 Resolved
REPLACE WEATHER TIGHT DOORS ON SUPERSTRUCTURE. (ILLC 66 ANNEX 1/18)
Condition: Unknown
Due 26 June 1998
Resolved 26 June 1998
Unknown
Issued 9 December 1997 Resolved
REPLACE AUXILARY CONDENSER COOLING LINE AT PUMP SUCTION AT CEMENT PATCH. (SOLAS 74 AMEND) I/11).
Condition: Unknown
Due 26 June 1998
Resolved 26 June 1998
Unknown
Issued 9 December 1997 Resolved
FIRE EXTINGUISHERS NOT SERVICED IAW REQUIRED TIME. (SOLAS 74 REG I/8)
Condition: Unknown
Due 26 June 1998
Resolved 26 June 1998
Accommodation/Occupational Safety
Issued 10 December 1996 Resolved
MEDICATION IN DISPENSARY EXPIRED. (ILO 147)
Condition: Unknown
Due 15 December 1996
Resolved 19 December 1996
Accommodation/Occupational Safety
Issued 10 December 1996 Resolved
HOSPITAL SPACE USED FOR NON-MEDICAL PURPOSES. (IL0 147).
Condition: Unknown
Due 15 December 1996
Resolved 19 December 1996
Navigation
Issued 6 December 1992 Resolved
A VIO OF 33 CFR 164.33(a)(1)(ii) IN THAT US CHARTS 12230, 12263, 12278, AND12281, USED BY THE VESSEL WERE NOT CORRECTED UP TO NTMS 35/92, WHICH WERE REASONABLY AVAILABLE AND CONTAINED CORRECTIONS APPLICABLE TO THE VESSELS RTE FROM SMITH PT VA TO BALTO HARBOR. NO FOREIGN EQUIVALENT O/B.
Condition: Unknown
Due 27 October 1995
Resolved 27 October 1995
Navigation
Issued 6 December 1992 Resolved
A VIO OF 33 CFR 164.33(a)(2)(ii) IN THAT THE USCG LIGHT LIST USED BY THE VESSEL WAS NOT CORRECTED UP THRU NTMS 35/92, WHICH WERE REASONABLY AVAILABLE AND CONTAINED CORRECTIONS APPLICABLE TO THE VESSELS RTE FROM SMITH PT VA TO BALTO HARBOR. NO FOREIGN EQUIVALENT O/B._x001C_
Condition: Unknown
Due 27 October 1995
Resolved 27 October 1995
Navigation
Issued 6 December 1992 Resolved
A VIO OF 33 CFR 164.33(a)(2)(i) IN THAT THE US COAST PILOT VOL 3 USED BY THE VESSEL, WAS NOT CORRECTED UP THRU NTM 35/92, WHICH WERE REASONABLY AVAILABLE AND CONTAINED CORRECTIONS APPLICABLE TO THE VESSELS RTE FROM SMITH PT VA TO BALTO HARBOR. NO FOREIGN EQUIVALENT O/B._x001C_
Condition: Unknown
Due 27 October 1995
Resolved 27 October 1995

Ownership record