Records from 2016 to 2025. Most recent: inspection, 7 May 2025.
Inspection history · 16
7 May 2025
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8108862
31 October 2024
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8026542
5 March 2024
COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7864168
11 January 2024
Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7819260
5 July 2023
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7713527
7 July 2022
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7490853
28 January 2022
Hull Examination · Administrative Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7360289
9 July 2021
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7249731
14 August 2020
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7029175
8 January 2020
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6847198
9 April 2019
COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6653844
14 February 2018
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6354850
5 December 2017
Administrative Inspection · Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6318699
8 May 2017
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6126487
11 July 2016
DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5933747
13 January 2016
Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5796103
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 July 2023
Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment, and reasonably safe from electrical shock of personnel.
Discovered dead end wire under the main operating station.
46 CFR 183.01-5(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2023
Resolved 27 July 2023
Resolution: Wires were connected properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 July 2023
Resolved
In systems and applications where flexible hoses are permitted to be clamped: (1) Double hose clamping is required where practicable.
Fuel line connections from both fuel tanks were not double clamped.
46 CFR 182.410
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2023
Resolved 27 July 2023
Resolution: Fuel lines connections were double clamped.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 July 2023
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. (2) Each ring life buoy with a floating waterlight must have a lanyard of at least 3 feet in length, but not more than 6 feet, securing the waterlight around the body of the ring lifebuoy.
Lanyard for the floating waterlight was damaged and worn from exposure to the marine environment.
46 CFR 180.70(d)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2023
Resolved 27 July 2023
Resolution: New lanyard was installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 July 2023
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced.
Ring life buoy retro-reflective tape was peeling off and deteriorated.
46 CFR 180.70(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2023
Resolved 27 July 2023
Resolution: New retro-reflective tape was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 July 2022
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh.
Inspector found missing vent screen on the starboard side fuel tank.
46 CFR 182.450(e)
Action required: 10 - Deficiency Rectified
Due 7 July 2022
Resolved 7 July 2022
Resolution: Vessel rep. installed new fuel tank vents with screens on both port and stbd fuel tanks.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 July 2022
Resolved
Each floating waterlight must be approved in accordance with §161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110.
Inspector found expired battery by four years in the lifebuoy water light.
46 CFR 180.71(d)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2022
Resolved 21 July 2022
Resolution: Inspector received confirmation that the battery was replaced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 August 2020
Resolved
The owner, managing operator, or a qualified servicing facility as applicable shall conduct the following inspections and tests for portable fire extinguishers, the inspections, maintenance procedures, and hydrostatic pressure tests required by Chapter 4 of NFPA 10…the owner or managing operator shall provide satisfactory evidence of the required servicing to the marine inspector.
01 portable extinguisher was not porperly serviced within the frequency required by NFPA 10.
46 CFR 176.810(b)(1)
Action required: 705 - Other - as specified
Due 21 August 2020
Resolved 19 August 2020
Resolution: Portable fire extinguisher serviced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 August 2020
Resolved
The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspector.
Bracket used to stow 01 portable fire extinguisher was cracked/broken rendering it inoperable.
46 CFR 181.30-10(b)
Action required: 705 - Other - as specified
Due 21 August 2020
Resolved 19 August 2020
Resolution: New mounting bracket installed.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 14 August 2020
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters high indicating purpose of the valve and direction of operation.
The direction of operation for 01 remote fuel shutoff station labeled incorrectly.
46 CFR 185.608
Action required: 10 - Deficiency Rectified
Resolved 14 August 2020
Resolution: Vessel operator corrected valve direction; therefore, marking was accurate.
Construction/Loadline › Hull › Hull Plating
Issued 13 January 2016
Resolved
Repair two damaged areas on port bow IAW 46 CFR 176.610.
Action required: 705 - Other - as specified
Due 13 February 2016
Resolved 22 January 2016
Resolution: Repairs made to the satisfaction of the attending MI.
Construction/Loadline › Hull › Hull Plating
Issued 13 January 2016
Resolved
Repair damaged area on starboard side IAW 46 CFR 176.610.
Action required: 705 - Other - as specified
Due 13 February 2016
Resolved 22 January 2016
Resolution: Repairs made to the satisfaction of the attending MI.
Construction/Loadline › Hull › Hull Plating
Issued 13 January 2016
Resolved
Repair area where deck meets the hull on the bow IAW 46 CFR 176.610.
Action required: 705 - Other - as specified
Due 13 February 2016
Resolved 22 January 2016
Resolution: Repairs made to the satisfaction of the attending MI.