Records from 1989 to 2025. Most recent: inspection, 7 May 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 57
7 May 2025
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8108862
31 October 2024
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8026542
5 March 2024
COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7864168
11 January 2024
Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7819260
5 July 2023
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7713527
7 July 2022
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7490853
28 January 2022
Hull Examination · Administrative Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7360289
9 July 2021
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7249731
14 August 2020
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7029175
8 January 2020
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6847198
9 April 2019
COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6653844
14 February 2018
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6354850
5 December 2017
Administrative Inspection · Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6318699
8 May 2017
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6126487
11 July 2016
DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5933747
13 January 2016
Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5796103
21 March 2014
Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4819567
21 June 2012
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4351125
26 January 2012
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4232400
12 July 2011
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4078601
29 March 2010
Administrative Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3706018
14 April 2009
Internal Structural Exam · Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3452186
8 July 2008
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3261199
5 March 2008
Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3158568
10 July 2007
Annual Inspection · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2989112
14 July 2006
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2710569
3 February 2006
Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2573213
24 May 2005
Deficiency Check · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2362655
27 April 2005
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2344072
8 June 2004
Deficiency Check · In-Service Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2093559
15 April 2004
COI Inspection · Plan Review "T" Boat
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2043866
29 March 2004
Simplified Stability Test
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2033206
26 January 2004
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1996108
3 October 2003
In-Service Inspection · Administrative Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1889094
28 January 2003
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1736713
9 September 2002
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1667640
30 August 2001
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1444593
16 August 2001
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1451747
29 September 2000
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 822425
30 September 1999
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1448011
2 September 1999
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1384240
1 September 1998
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1378472
22 September 1997
Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1372150
4 September 1996
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1416362
25 September 1995
COI Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1181510
6 December 1994
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1145014
19 September 1994
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 868318
21 September 1993
Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 840011
5 October 1992
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 933585
28 September 1992
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1267876
25 September 1991
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1250537
26 August 1991
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 935988
7 January 1991
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 899481
11 December 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 922640
6 November 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 908275
15 October 1990
Re-Inspection · Drydock Extension
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1230214
29 September 1989
Initial Certification · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1341894
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 July 2023
Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment, and reasonably safe from electrical shock of personnel.
Discovered dead end wire under the main operating station.
46 CFR 183.01-5(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2023
Resolved 27 July 2023
Resolution: Wires were connected properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 July 2023
Resolved
In systems and applications where flexible hoses are permitted to be clamped: (1) Double hose clamping is required where practicable.
Fuel line connections from both fuel tanks were not double clamped.
46 CFR 182.410
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2023
Resolved 27 July 2023
Resolution: Fuel lines connections were double clamped.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 July 2023
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. (2) Each ring life buoy with a floating waterlight must have a lanyard of at least 3 feet in length, but not more than 6 feet, securing the waterlight around the body of the ring lifebuoy.
Lanyard for the floating waterlight was damaged and worn from exposure to the marine environment.
46 CFR 180.70(d)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2023
Resolved 27 July 2023
Resolution: New lanyard was installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 July 2023
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced.
Ring life buoy retro-reflective tape was peeling off and deteriorated.
46 CFR 180.70(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2023
Resolved 27 July 2023
Resolution: New retro-reflective tape was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 July 2022
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh.
Inspector found missing vent screen on the starboard side fuel tank.
46 CFR 182.450(e)
Action required: 10 - Deficiency Rectified
Due 7 July 2022
Resolved 7 July 2022
Resolution: Vessel rep. installed new fuel tank vents with screens on both port and stbd fuel tanks.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 July 2022
Resolved
Each floating waterlight must be approved in accordance with §161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110.
Inspector found expired battery by four years in the lifebuoy water light.
46 CFR 180.71(d)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2022
Resolved 21 July 2022
Resolution: Inspector received confirmation that the battery was replaced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 August 2020
Resolved
The owner, managing operator, or a qualified servicing facility as applicable shall conduct the following inspections and tests for portable fire extinguishers, the inspections, maintenance procedures, and hydrostatic pressure tests required by Chapter 4 of NFPA 10…the owner or managing operator shall provide satisfactory evidence of the required servicing to the marine inspector.
01 portable extinguisher was not porperly serviced within the frequency required by NFPA 10.
46 CFR 176.810(b)(1)
Action required: 705 - Other - as specified
Due 21 August 2020
Resolved 19 August 2020
Resolution: Portable fire extinguisher serviced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 August 2020
Resolved
The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspector.
Bracket used to stow 01 portable fire extinguisher was cracked/broken rendering it inoperable.
46 CFR 181.30-10(b)
Action required: 705 - Other - as specified
Due 21 August 2020
Resolved 19 August 2020
Resolution: New mounting bracket installed.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 14 August 2020
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters high indicating purpose of the valve and direction of operation.
The direction of operation for 01 remote fuel shutoff station labeled incorrectly.
46 CFR 185.608
Action required: 10 - Deficiency Rectified
Resolved 14 August 2020
Resolution: Vessel operator corrected valve direction; therefore, marking was accurate.
Construction/Loadline › Hull › Hull Plating
Issued 13 January 2016
Resolved
Repair two damaged areas on port bow IAW 46 CFR 176.610.
Action required: 705 - Other - as specified
Due 13 February 2016
Resolved 22 January 2016
Resolution: Repairs made to the satisfaction of the attending MI.
Construction/Loadline › Hull › Hull Plating
Issued 13 January 2016
Resolved
Repair damaged area on starboard side IAW 46 CFR 176.610.
Action required: 705 - Other - as specified
Due 13 February 2016
Resolved 22 January 2016
Resolution: Repairs made to the satisfaction of the attending MI.
Construction/Loadline › Hull › Hull Plating
Issued 13 January 2016
Resolved
Repair area where deck meets the hull on the bow IAW 46 CFR 176.610.
Action required: 705 - Other - as specified
Due 13 February 2016
Resolved 22 January 2016
Resolution: Repairs made to the satisfaction of the attending MI.
Construction/Loadline › Structures › Deck Plating
Issued 10 July 2007
Resolved
DRAFT A REPAIR PROPOSAL/PLAN TO REPLACE DAMAGED INTERNAL STRUCTURAL MEMBERS AND SUBMIT TO SECTOR ST PETE OCMI FOR APPROVAL.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2007
Resolution: All repairs completed.
Construction/Loadline › Structures › Superstructure
Issued 10 July 2007
Resolved
INSTALL A NON-COMBUSTIBLE PANEL BETWEEN FUEL TANKS AND ACCOMADATION SPACE.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 August 2007
Resolution: Panel was installed.
Engineering › Fuel Oil Service System › Valve, Control
Issued 10 July 2007
Resolved
INSTALL METALLIC CABLE FOR REMOTE FUEL SHUTOFF VALVES.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 August 2007
Resolution: Metallic cable was installed.
Electrical › Electric Supply System (service) › Cable
Issued 10 July 2007
Resolved
REATTACH ELECTRICAL CABLES UNDER OPERATING STATION AS NEEDED.
Due 27 July 2007
Resolved 31 August 2007
Resolution: Electrical cables were reattached.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 14 July 2006
Resolved
Replace all retro-reflective tape on life jackets as needed. Jackets are stowed in an area that contains moisture, and the retro-tape gets moldy and delaminates. Discussed with POC ways to prevent this problem. POC has tape on board to replace worn tape.
Condition: Improper/Lack of Maintenance
Due 21 July 2006
Resolved 20 July 2006
Resolution: POC stated that all jackets have been corrected. They are replacing all retro-reflective tape on all jackets, even if they do not need it.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 14 July 2006
Resolved
Provide the proper line for ring buoy and float light IAW 46CFR180.70(c). They have 1/8" line instead of 5/16" line.
Condition: Improper Installation
Due 21 July 2006
Resolved 20 July 2006
Resolution: POC attested to the change out and faxed over a receipt for new line.
Lifesaving › Hand Flares › Quantity
Issued 24 May 2005
Resolved
Provide 09 red hand held day/knight flares in a water proof container marked "DISTRESS SIGNALS" IAW 46CFR180.68 & 185.614. They had 3 red and 3 orange, in which the 3 red will expire at the end of the month.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 May 2005
Resolved 3 June 2005
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 24 May 2005
Resolved
Provide a work vest and safety line for crew, during person OVBD drill as discussed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 June 2005
Resolved 3 June 2005
Engineering › Bilge Water Management System › Pump
Issued 24 May 2005
Resolved
Provide a 5 GPM hand portable bilge pump.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 May 2005
Resolved 3 June 2005
Navigation › Piloting/Steering › Magnetic Compass
Issued 24 May 2005
Resolved
Prior to night time operation, repair compass light.
Condition: Improper/Lack of Maintenance
Due 26 May 2005
Resolved 3 June 2005
Engineering › Gasoline Engine (propulsion)
Issued 15 April 2004
Resolved
INSTALL REMOTE MEANS OF OPERATING FUEL STOPS PRIOR TO CARRIAGE OF PASSENGERS.. LEGACY COMPONENT DESC: Fuel Sops
Due 15 May 2004
Resolved 8 June 2004
Resolution: SAT
Engineering › Fuel Oil Storage/Transfer System
Issued 15 April 2004
Resolved
RE-LOCATE FUEL STRAINERS OUTSIDE OF PASSENGER COMPARTMENT PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Filter/Strainer
Due 15 May 2004
Resolved 8 June 2004
Resolution: SAT
Engineering › Bilge Water Management System
Issued 15 April 2004
Resolved
PROPERLY INSTALL POSITIVE CLOSURE DEVICES ON BILGE DISCHARGES PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Valve
Due 15 May 2004
Resolved 8 June 2004
Resolution: SAT
Operations/Management › Drills/Instruction
Issued 15 April 2004
Resolved
POST EMERGENCY INSTRUCTION UNIQUE TO VESSEL OPERATIONS PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Emergency Instructions
Due 15 May 2004
Resolved 8 June 2004
Resolution: SAT
Construction/Loadline › Structures
Issued 15 April 2004
Resolved
PROPERLY INSTALL FLUSH DECK WATERTIGHT HATCHES PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Manhole
Due 15 May 2004
Resolved 8 June 2004
Resolution: SAT
Lifesaving › Lifejacket/PFD (General)
Issued 15 April 2004
Resolved
PROPERLY LABEL LIFEJACKET STOWAGE AREAS PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Marking
Due 15 May 2004
Resolved 15 June 2004
Resolution: SAT
Construction/Loadline › Hull
Issued 3 October 2003
Resolved
COMPLETE CREDIT DRYDOCK EXAMINATION. DEMONSTRATE TO THE SATISFACTION OF AN ATTENDING CG MARINE INSPECTOR PROPER REMOVAL OF ALL HULL BLISTERING AND RESTORATION OF CATAMARAN HULLS BACK TO ORIGINAL. LEGACY COMPONENT DESC: Hull Plating
Condition: Unknown
Due 4 October 2003
Resolved 26 January 2004
Resolution: CREDIT D/D.
Engineering › Bilge Water Management System
Issued 9 September 2002
Resolved
REPAIR PORT/STARBOARD MANUAL BILGE PUMPS PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Due 23 September 2002
Resolved 28 January 2003
Resolution: CLEARED VIA FAX (09SEP02).
Engineering › Fuel Oil Storage/Transfer System
Issued 9 September 2002
Resolved
MOVE GAS/OIL TO STERN AWAY FROM PASSENGER COMPARTMENT. LEGACY COMPONENT DESC: Portable Fuel System
Condition: Improper Installation
Due 9 October 2002
Resolved 28 January 2003
Resolution: CLEARED VIA FAX DOCUMENTATION (09SEP02).
Accommodation/Occupational Safety › Occupational Safety
Issued 9 September 2002
Resolved
POST NO SMOKING SIGNS ON STERN OF VESSEL IN WAY OF FUEL TANKS. LEGACY COMPONENT DESC: Smoking
Condition: Improper Installation
Due 9 October 2002
Resolved 28 January 2003
Resolution: CLEARED VIA FAX DOCUMENTATION (09SEP02).
Engineering › Fuel Oil Storage/Transfer System
Issued 9 September 2002
Resolved
REPLACE FUEL TANK VENT LINES. LEGACY COMPONENT DESC: Vent Pipe
Condition: Improper/Lack of Maintenance
Due 16 September 2002
Resolved 28 January 2003
Resolution: CLEARED VIA FAX DOCUMENTATION/PHONECON.
Accommodation/Occupational Safety › Occupational Safety
Issued 9 September 2002
Resolved
POST LIFEJACKET DONNING PROCEDURES PRIOR TO CARRIAGE OF PASSENGERS.. LEGACY COMPONENT DESC: Placards
Condition: Improper Installation
Due 16 September 2002
Resolved 28 January 2003
Resolution: CLEARED VIA FAX DOCUMENTATION (09SEP02).
Lifesaving
Issued 30 September 1999
Resolved
INSTALL NEW 24" LIFERING WITH MINIMUM 60' FLOATABLE BLACK LINE AND 3'-6' FLOATABLE BLACK LINE WITH CORROSION RESISTANT CLIP FOR STROBE LIGHT PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 9 October 1999
Resolved 8 October 1999
Lifesaving
Issued 30 September 1999
Resolved
PROPERLY STOW AND LABEL LIFEJACKET STOWAGE AREAS. ENSURE SEPERATION OF ADULT AND CHILDSIZE LIFEJACKETS
Condition: Unknown
Due 6 October 1999
Resolved 8 October 1999
Documentation
Issued 30 September 1999
Resolved
PROVIDE COPY OF DRUG CONSORTIUM CONTRACT.
Condition: Unknown
Due 6 October 1999
Resolved 8 October 1999
Electrical
Issued 1 September 1998
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 2 October 1998
Resolved 2 October 1998
Construction/Loadline
Issued 1 September 1998
Resolved
RENEW HAND BILGE PUMP HOSE
Condition: Unknown
Due 2 October 1998
Resolved 2 October 1998
Navigation
Issued 1 September 1998
Resolved
REPAIR MASTHEAD LIGHT.
Condition: Unknown
Due 2 October 1998
Resolved 2 October 1998
Navigation
Issued 1 September 1998
Resolved
RENEW OUTDATED DISTRESS SIGNALS (HAND HELD FLARES)
Condition: Unknown
Due 2 October 1998
Resolved 2 October 1998
Engineering
Issued 22 September 1997
Resolved
DOUBLE CLAMP ALL FUEL FITTINGS.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Navigation
Issued 22 September 1997
Resolved
REINSTALL BOLTS IN STEERING ARM (LAZY SUSAN) SO AS TO PRECLUDE LOSS IN EVENT THAT NUT BACKS OFF.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Lifesaving
Issued 22 September 1997
Resolved
INSTALL RETROREFLECTIVE MATERIAL ON LIFERING.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Construction/Loadline
Issued 22 September 1997
Resolved
REPLACE TRANSVERSE DECK STRINGER #12.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Construction/Loadline
Issued 22 September 1997
Resolved
REPLACE UNDERDECKING IN VICINITY OF FWD HATCH (PORT).
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Construction/Loadline
Issued 22 September 1997
Resolved
REPAIR GELCOAT AT BOW.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Construction/Loadline
Issued 22 September 1997
Resolved
REPAIR FRP AT SHEAR STRAKE P&S.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Engineering
Issued 22 September 1997
Resolved
FASTEN PORTABLE GAS TANKS IN PLACE.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Accommodation/Occupational Safety
Issued 22 September 1997
Resolved
REPAIR CRACKED BASE OF RAIL.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Construction/Loadline
Issued 22 September 1997
Resolved
REFASTEN GUSSET TO #1 TRANSVERSE DECK STRINGER AND RE-GLASS IN PLACE.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Construction/Loadline
Issued 22 September 1997
Resolved
REPLACE RUBRAIL OR FILL BOLT HOLES THROUGH SHEAR STRAKE.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Accommodation/Occupational Safety
Issued 22 September 1997
Resolved
REPAIR AND REFASTEN DODGER SO THAT NO GAPS >12" EXIST.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Construction/Loadline
Issued 22 September 1997
Resolved
RESTENCIL REGISTRATION NUMBERS.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Construction/Loadline
Issued 22 September 1997
Resolved
REPLACE TRANSVERSE DECK STRINGERS #5 AND #10.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Construction/Loadline
Issued 22 September 1997
Resolved
REPLACE GUSSET #13 PORTSIDE.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Construction/Loadline
Issued 22 September 1997
Resolved
REFASTEN ALL GUSSETS, HALF FRAMES, AND FULL FRAMES TO TRANSVERSE DECK STRINGERS AS NEEDED.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Construction/Loadline
Issued 22 September 1997
Resolved
REPLACE HALF FRAME #6 STBD.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Construction/Loadline
Issued 19 September 1994
Resolved
REPLACE BOTH FORWARD HULL ACCESS COVER AND REMOVE WATER FROM BILGE.
Condition: Unknown
Due 19 September 1994
Resolved 19 September 1994
Engineering
Issued 19 September 1994
Resolved
REPAIR STARBOARD OUTBOARD ENGINE AND DEMONSTRATE OPERATION.
Condition: Unknown
Due 19 September 1994
Resolved 19 September 1994
Lifesaving
Issued 28 September 1992
Resolved
Dry-out all pfd's prior to carrying passengers.
Condition: Unknown
Due 20 October 1992
Resolved 20 October 1992
Lifesaving
Issued 28 September 1992
Resolved
Renew ring buoy prior to carrying passengers
Condition: Unknown
Due 20 October 1992
Resolved 20 October 1992
Navigation
Issued 28 September 1992
Resolved
Prove operation of anchor light.
Condition: Unknown
Due 20 October 1992
Resolved 20 October 1992
Fire Fighting
Issued 28 September 1992
Resolved
Remove rust from (B-II/2 ea) fire extinguishers.
Condition: Unknown
Due 20 October 1992
Resolved 20 October 1992
Lifesaving
Issued 28 September 1992
Resolved
Remark vessel's name on 13 adult pfd's, and 15 child pfd's.
Condition: Unknown
Due 20 October 1992
Resolved 20 October 1992
Engineering
Issued 25 September 1991
Resolved
REPLACE STBD OTBD FUEL LINE.
Condition: Unknown
Due 3 October 1991
Resolved 3 October 1991
Engineering
Issued 25 September 1991
Resolved
REPLACE FUEL LINE FROM SQUEEZE BULB TO OUTBOARD ENG PORT SIDE.
Condition: Unknown
Due 3 October 1991
Resolved 3 October 1991
Construction/Loadline
Issued 25 September 1991
Resolved
SEAL INSPECTION FORT FOR BOTH GILL BRACKETS.
Condition: Unknown
Due 3 October 1991
Resolved 3 October 1991
Lifesaving
Issued 26 August 1991
Resolved
PROVIDE 6 RED & 6 ORANGE HAND HELD FLARES PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 26 August 1991
Resolved 26 August 1991
Engineering
Issued 26 August 1991
Resolved
CORRECT FUEL LINES HANGING ON LINKAGE.
Condition: Unknown
Due 26 August 1991
Resolved 26 August 1991
Engineering
Issued 26 August 1991
Resolved
INSTALL FUEL TANK STRAPS.
Condition: Unknown
Due 26 August 1991
Resolved 26 August 1991
Engineering
Issued 11 December 1990
Resolved
PROPERLY MARK EMERGENCY FUEL OIL SHUT OFF.
Condition: Unknown
Due 11 December 1990
Resolved 11 December 1990
Fire Fighting
Issued 6 November 1990
Resolved
PROVIDE TOTAL TWO B-II FIRE EXTINGUISHERS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Engineering
Issued 6 November 1990
Resolved
DOUBLE CLAMP ALL FUEL LINES PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Fire Fighting
Issued 6 November 1990
Resolved
RECHARGE OR RENEW B-I FIRE EXTINGUISHER AR HELM PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Navigation
Issued 15 October 1990
Resolved
REPAIR ANCHOR LIGHT.
Condition: Unknown
Due 15 October 1990
Resolved 15 October 1990
Documentation
Issued 15 October 1990
Resolved
POST STABILITY LETTER, GARBAGE STICKER, POLLUTION STICKER, COI AND EMERGENCY INSTRUCTIONS.
Condition: Unknown
Due 15 October 1990
Resolved 15 October 1990
Engineering
Issued 15 October 1990
Resolved
RENEW FUEL LINES WITH USCG APPROVED TYPE AND INSTALL FUEL SHUTOFF WITH REMOTE PULL.
Condition: Unknown
Due 15 October 1990
Resolved 15 October 1990
Construction/Loadline
Issued 15 October 1990
Resolved
DRYDOCK DUE 30SEP91. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS INSPECTION.
Condition: Unknown
Due 15 October 1990
Resolved 15 October 1990
Fire Fighting
Issued 15 October 1990
Resolved
PROVIDE MARINE TYPE FIRE EXTINGUISHER BRACKETS FOR 2 B-II EXTINGUISHERS.
Condition: Unknown
Due 15 October 1990
Resolved 15 October 1990