Records from 2016 to 2026. Most recent: inspection, 1 June 2026.
Inspection history · 17
1 June 2026
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8385695
17 April 2026
Drydock Exam · Internal Structural Exam · Deficiency Check · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8349563
22 April 2025
Annual Inspection · Examination of Repairs · Administrative Inspection · In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8087844
23 April 2024
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7891767
1 March 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7865975
9 May 2023
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7684185
6 April 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7644651
16 March 2022
Deficiency Check · Annual Inspection · Internal Structural Exam · Drydock Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7412894
19 April 2021
COI Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7164894
28 April 2020
DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6939508
12 February 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6898056
16 May 2019
DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6675257
7 May 2018
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6403190
12 February 2018
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6349589
8 May 2017
Annual Inspection · Administrative Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6132172
28 April 2016
DAPI Audit · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5838073
8 March 2016
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5824611
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 17 April 2026
Resolved
The fiberglass at the port side aft engine mount has delaminated. Gouge out affected area and repair with new fiberglass.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2026
Resolved 14 May 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 April 2026
Resolved
Individual bilge pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation. Vessel's bilge pump light was inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2026
Resolved 14 May 2026
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 April 2026
Resolved
A vessel not required to have a power driven fire pump must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words ‘‘FIRE BUCKET’’ must be stenciled in a contrasting color on each bucket. Vessel is missing one out of the 3 required fire buckets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2026
Resolved 14 May 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 April 2025
Resolved
At each initial and subsequent inspections the owner or managing operator shall be prepared to conduct machinery tests. Test of machinery alarms in newly installed engine to be completed in the presence of an attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2026
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 23 April 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date publications.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 3 May 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 April 2024
Resolved
The name of a vessel must be marked or painted in clearly legible letters and numbers on each life ring and each life jacket. Life ring & lifejackets did not have updated vessel name on them.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 3 May 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 April 2023
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operations. Floating waterlight does not work.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2023
Resolved 20 April 2023
Resolution: Floating waterlight is now working properly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 May 2022
Resolved
A vessel not more than 26ft in length must carry a minimum of one life buoy of not less than 20 inches in diameter. Vessel ring life buoy is no longer serviceable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2022
Resolution: Ring life buoy has been replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 May 2022
Resolved
A vessel must carry one floating waterlight unless it is limited to daylight operations only. Vessel does not have a waterlight for the ring life buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2022
Resolution: Floating waterlight is onboard and working.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 5 May 2022
Resolved
The master of the vessel shall keep a correct written count of all passengers that embark and disembark from the vessel. Prior to departing, the passenger count must be communicated verbally or in writing and available ashore at the vessel's normal berthing location or with a representative. No passenger count method established.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2022
Resolved 16 May 2022
Resolution: Passenger count method established via logbook and contacting the marina office.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 5 May 2022
Resolved
Provision must be made for closing all ducts and openings for a space protected by a fixed gas fire extinguishing system. Vessel does not have a way to close ventilation ducts for engine space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2022
Resolved 16 May 2022
Resolution: Obtained stuffing onboard to secure ventilation in case of fire.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 April 2021
Resolved
Each ring lifebuoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018. Ring life buoy does not have retroreflective tape on it.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2021
Resolved 26 April 2021
Resolution: Vessel marked their ring lifebuoy with retroreflective tape.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 7 May 2018
Resolved
Provide new FCC Safety Radio Certificate.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 10 May 2018
Resolution: Provided new FCC Safety Radio Certificate.
Communications › Radio Communications › VHF Radiotelephone
Issued 7 May 2018
Resolved
Configure radio to show MMSI # and position information.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 7 June 2018
Resolution: Configured radio to show MMSI # and position information.
Engineering › Fuel Oil Service System › Filter
Issued 8 May 2017
Resolved
Replace fuel filter with a USCG or ABS approved filter.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 14 June 2017