Records from 1989 to 2025. Most recent: inspection, 25 September 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 67
25 September 2025
COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8239757
6 February 2025
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8075761
26 March 2024
Hull Examination · In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7884491
1 November 2023
Periodic Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7819755
21 July 2022
Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7513412
7 December 2021
Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7364029
21 September 2020
DAPI Audit · Drydock Exam · COI Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7060043
5 December 2019
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6868613
8 April 2019
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6660227
28 November 2018
Administrative Inspection · Periodic Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6588873
21 June 2018
Administrative Inspection
Administrative · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6451412
1 June 2018
Administrative Inspection
Administrative · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6431476
2 April 2018
Deadweight Survey
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6384762
12 December 2017
Simplified Stability Test
Physical examination · Marine Safety Center (MSC) · Activity 6325103
6 December 2017
Simplified Stability Test · Administrative Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6319633
6 October 2017
Administrative Inspection
Administrative · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6282660
7 September 2017
DAPI Audit · Hull Examination · Annual Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6267695
11 January 2017
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6074023
13 October 2015
COI Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 5741536
17 January 2012
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 4226761
27 September 2010
DAPI Audit · COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3861053
24 July 2008
In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3277539
14 May 2008
Annual Inspection · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3206545
5 November 2007
Hull Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3093232
30 October 2006
Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2807198
27 October 2005
COI Inspection · Hull Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2522310
6 October 2005
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2509143
22 February 2005
Hull Examination · Internal Structural Exam
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2295380
11 May 2004
Annual Inspection · MARPOL Annex V Examination · Simplified Stability Test
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2061916
19 April 2004
Administrative Inspection
Administrative · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2047406
6 May 2003
Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1785060
8 April 2003
Deficiency Check
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1770097
28 January 2003
Hull Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1733835
18 June 2002
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1631079
7 January 2002
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1476196
18 May 2001
COI Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1467757
22 January 2001
Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1413864
2 May 2000
Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1369687
10 May 1999
Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1438833
9 March 1999
Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1437543
14 May 1998
MARPOL Annex V Examination · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 791349
10 July 1997
MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 776082
19 April 1997
Hull Examination · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1103141
21 June 1996
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 930563
16 June 1995
COI Inspection · MARPOL Annex V Examination · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1190256
2 June 1995
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1183967
24 August 1994
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1175061
9 August 1994
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 865189
18 October 1993
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1146267
2 August 1993
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1152337
7 July 1993
Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1160217
28 September 1992
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 959766
9 July 1992
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 949336
13 January 1992
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 955288
13 November 1991
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1006040
26 August 1991
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 936059
17 June 1991
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 958889
17 June 1991
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1352137
24 January 1991
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1223539
26 November 1990
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1221465
6 November 1990
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 907967
15 October 1990
Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 917510
13 August 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 909762
11 July 1990
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 899314
23 October 1989
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 886664
31 July 1989
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 886564
12 July 1989
Hull Examination · Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1348246
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 February 2025
Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. Vessel is overdue for its 4th annual inspection.
46 CFR 176.500(a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 February 2025
Resolution: Completed Annual Inspection.
Stability › Intact Stability (when using lifting gear) › General
Issued 6 October 2017
Resolved
reduced px count until new Pontoon Simplified Stability Test completed due to weight differnce in new/old out board engines.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 19 January 2018
Lifesaving › Hand Flares › Quantity
Issued 7 September 2017
Resolved
Missing 2 Red Flares
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2017
Resolved 20 September 2017
Resolution: Purchased new flares
Lifesaving › Lifebuoys › Serviceable
Issued 11 January 2017
Resolved
Aft ring life buoy needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 January 2017
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 January 2017
Resolved
Float light attached to aft ring life buoy needs to be replaced (3ft to 6ft) and attached around body with a corrosion resistant clip.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 January 2017
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 11 January 2017
Resolved
Fwd ring life buoy needs grab line replaced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 January 2017
Lifesaving › Buoyant Smoke Signals › General
Issued 19 October 2010
Resolved
Vessel is missing two Orange Smoke Signals, it has 4 Red Flares and 1 Orange Smoke. Vessel is permitted to carry 3 red flares and 3 orange smoke or 6 red flares. Provide proof of either 2 additional orange smoke flares or 2 additional red flares.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 October 2010
Resolution: Purchased two USCG approved red flares.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 19 October 2010
Resolved
Fire extinguishers are missing annual servicing tags. Provide proof of annual servicing for portable fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 October 2010
Resolved 20 October 2010
Resolution: Vessel operator borrowed 3 approved extinguishers for afternoon cruise on OCT 19 and provided proof of fire extinguisher servicing conducted on OCT 20.
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 19 October 2010
Resolved
No proof of CPR Certification for 50% of crew. Provide proof that at least 50% of crew has current/valid CPR certification.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 October 2010
Resolution: Vessel operator provided proof of CPR training (American Heart Association) expires 10/2012 and first aid training (American Red Cross), expires 3/2011.
Engineering › Fuel Oil Service System › Hose
Issued 19 October 2010
Resolved
Fuel lines between fuel filters and fuel tanks are not double clamped. Provide double clamps at connection points on hoses between fuel filters and fuel tanks.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2010
Resolution: Vessel operator purchased an installed hose clamps on fuel line as required.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 19 October 2010
Resolved
Drug and Alcohol Program and records were not readily available for inspection. Please provide proof of Drug and Alcohol Program and records to attending Coast Guard marine inspector.
Action required: 705 - Other - as specified
Due 18 November 2010
Resolved 17 November 2010
Resolution: Program available for review. DAPI Audit conducted with no deficiencies issued.
Electrical › Lighting (service) › Switch
Issued 5 August 2008
Resolved
Provide switch for anchor light at operations console.
Condition: Improper Installation
Due 10 August 2008
Resolved 13 August 2008
Resolution: Received fax from owner certifying item corrected.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 5 August 2008
Resolved
Mount first aid kit so available and visible to crew/passengers.
Condition: Improper Installation
Due 10 August 2008
Resolved 13 August 2008
Resolution: Fax received certifying deficiency corrected.
Lifesaving › Lifebuoys › Serviceable
Issued 5 August 2008
Resolved
Provide retro-reflective tape for bow life ring.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 August 2008
Resolved 13 August 2008
Resolution: Received fax certifying correction of deficiency.
Engineering › Fuel Oil Service System › Hose
Issued 5 August 2008
Resolved
Replace fuel hoses with those meeting requirements of 46 CFR 182.720.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 August 2008
Resolved 13 August 2008
Resolution: Received fax certifying that deficiency has been corrected.
Documentation › Markings/Placards › Official Number (US)
Issued 5 August 2008
Resolved
Provide hailing port on the stern of vessel.
Due 10 August 2008
Resolved 13 August 2008
Resolution: Received fax from vessel certifying correction of deficiency.
Documentation › Markings/Placards › Vessel Number (state)
Issued 5 August 2008
Resolved
Remove FL official numbers and replace with new TN registration.
Due 10 August 2008
Resolved 13 August 2008
Resolution: Received fax certifying deficiency corrected.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 5 August 2008
Resolved
Remove frayed line from forward life ring.
Due 10 August 2008
Resolved 13 August 2008
Resolution: Received fax certifying deficiency corrected.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 14 May 2008
Resolved
Ensure that all passenger seats are properly secured prior to the carriage of the same.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2008
Documentation › Markings/Placards › Warning Signs
Issued 14 May 2008
Resolved
Post emergency broadcast instruction next to the radio.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 June 2008
Resolved 5 August 2008
Resolution: Instructions posted.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 5 November 2007
Resolved
Conduct annual service on all portable fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 January 2008
Resolved 16 May 2008
Resolution: Extinguishers recewntly serviced.
Construction/Loadline › Hull › Bracket
Issued 5 November 2007
Resolved
All mounting bolts for pontoons are causing aluminum mounting brackets to corrode. Install spacers between mounting bolt washers and aluminum bracket to reinforce and minimize corrosion.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 January 2008
Resolved 16 May 2008
Resolution: Bolts replaced
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 November 2007
Resolved
All medicine out of date. Renew first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 January 2008
Resolved 16 May 2008
Resolution: First aid kit renewal.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 30 October 2006
Resolved
Provide proof of enrollment in an approved Drug and Alcohol Program, as required by 46 CFR Part 16.
Condition: Unknown
Due 5 November 2006
Resolved 13 November 2006
Resolution: Received FAX copy of enrollment.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Approval
Issued 30 October 2006
Resolved
Renew two hand portable fire extinguisher. One to be a minimum capacity of 10 lb dry chemical to be rated A-II; one to be a minimum capacity of 2 lb dry chemical to be rated B-I.
Condition: Improper Installation
Due 5 November 2006
Resolved 13 November 2006
Resolution: Received FAX copy of purchase order.
Electrical › Lighting (service) › Switch
Issued 27 October 2005
Resolved
Anchor light inoperative when light switch activated.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 October 2005
Resolution: Double pole double throw navigation light switch installed improperly. Corrected while on board.
Lifesaving › Lifebuoys › Quantity
Issued 27 October 2005
Resolved
Provide on board one (1) additional ring life buoy in accordance with 46 CFR 180.70. This ring buoy is to be mounted forward of the passenger area.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2006
Resolution: Additional ring buoy mounted forward.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 27 October 2005
Resolved
Provide on board twenty (20) additional Adult Type I PFDs in accordance with 46 CFR 180.71.
Until this item is complete, the vessel is permitted to carry ten (10) adult and three (3) child passengers.
Action required: 705 - Other - as specified
Resolved 30 October 2006
Resolution: All PFDs satisfactory.
Operations/Management › Passenger Operations › Safety Orientation
Issued 27 October 2005
Resolved
Post or provide on board the passenger safety orientation required by 46 CFR 185.506.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2005
Resolution: New owner provided.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 27 October 2005
Resolved
Post the emergency instruction placard required by 46 CFR 185.510.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2006
Resolution: Placard located behind Pilot Station.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 27 October 2005
Resolved
Provide on board the applicable navigation publications and charts in accordance with 46 CFR 184.420.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2005
Resolution: New owner provided on board.
Engineering › Fuel Oil Service System › Valve
Issued 11 May 2004
Resolved
Repair stbd side fuel shutoff. It is inoperable, due to faulty installation.
Condition: Improper Installation
Due 25 May 2004
Resolved 11 June 2004
Resolution: Valve changed so that handle moves in proper direction. All sat.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 11 May 2004
Resolved
Renew or service B1 and BII fire extiguishers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2004
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 6 May 2003
Resolved
Address stowage for life jackets. Ensure easy accessibility. Temp solution of placing 1 lifejacket under each passenger's seat. Permanent stowage area still being addressed. Stowage are too small for jacket style Type 1 PFDs...was built to flat horseshoe collar sized PFDs.
Action required: 705 - Other - as specified
Resolved 30 October 2006
Resolution: PFDs stowed in overhead.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 6 May 2003
Resolved
Renew line on ringbuoy
Due 22 May 2003
Resolved 14 May 2003
Resolution: Replaced complete ringbuoy.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 May 2003
Resolved
Renew detachable clip on waterlight on ringbuoy.
Due 22 May 2003
Resolved 14 May 2003
Resolution: New carribeaner clip purchased and installed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 May 2003
Resolved
Renew eyewash in first aid kit.
Due 22 May 2003
Resolved 14 May 2003
Resolution: New eyewash purchased.
Lifesaving › Hand Flares › Storage
Issued 6 May 2003
Resolved
Provide bright, watertight container for flares.
Condition: Improper Installation
Due 22 May 2003
Resolved 14 May 2003
Resolution: Purchased orange utility dry container.
Engineering › Fuel Oil Service System › Valve
Issued 6 May 2003
Resolved
Repair port and starboard emergency fuel shutoffs.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 May 2003
Resolved 14 May 2003
Resolution: Replaced cable and ball joints.
Navigation › Piloting/Steering › Marine Charts
Issued 6 May 2003
Resolved
Provide chart for operating area.
Due 22 May 2003
Resolved 14 May 2003
Resolution: Chart provided.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 6 May 2003
Resolved
Service/replace BI and BII fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 May 2003
Resolved 14 May 2003
Resolution: Serviced BII extinguisher, replaced B1 extinguisher.
Communications › Radio Communications › VHF Radiotelephone
Issued 6 May 2003
Resolved
Provide emergency broadcast placard.
Due 22 May 2003
Resolved 14 May 2003
Resolution: Provided, personalized for vessel and posted.
Construction/Loadline › Hull
Issued 28 January 2003
Resolved
REPAIR/RENEW SECTION OF CRACKED DECK SUPPORT ON THE PORT PONTOON, JUST FORWARD OF THE FUEL TANK. LEGACY COMPONENT DESC: Stiffener
Due 15 March 2003
Resolved 8 April 2003
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 18 June 2002
Resolved
Renew lifeline for ring buoy IAW 46 CFR 180.70
Condition: Improper Installation
Due 30 June 2002
Resolved 27 June 2002
Resolution: New lifeline attached.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 18 June 2002
Resolved
Provide clip for waterlight IAW 46 CFR 180.70(d)(3)
Condition: Improper Installation
Due 30 June 2002
Resolved 27 June 2002
Resolution: Clip purchased and attached to waterlight.
Lifesaving › Lifejacket/PFD (General) › Official Number (US)
Issued 18 June 2002
Resolved
Provide and post lifejacket donning placard IAW 46 CFR 185.516
Condition: Unknown
Due 30 June 2002
Resolved 27 June 2002
Resolution: Posted.
Lifesaving › Visual Distress Signals (General)
Issued 18 June 2002
Resolved
Provide three orange distress signals IAW 46 CFR 184.710. Flares on board expired.
Due 30 June 2002
Resolved 27 June 2002
Resolution: Three orange flares purchased and placed on vessel.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 June 2002
Resolved
Provide contents of first aid kit IAW 46 CFR 174.710.
Due 30 June 2002
Resolved 27 June 2002
Resolution: New kit purchased.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 18 June 2002
Resolved
Service all portable fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 June 2002
Resolution: Vessel''s fire extinguishers serviced.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 18 June 2002
Resolved
Mount BI fire extinguisher.
Condition: Improper Installation
Due 30 June 2002
Resolved 27 June 2002
Resolution: New bracket purchased and mounted.
Navigation
Issued 18 May 2001
Resolved
REPLACE BURNT OUT STERN LIGHT.
Condition: Unknown
Due 1 June 2001
Resolved 12 June 2001
Lifesaving
Issued 18 May 2001
Resolved
MARK ALL PFDS WITH VESSEL NAME.
Condition: Unknown
Due 1 June 2001
Resolved 12 June 2001
Documentation
Issued 18 May 2001
Resolved
POST VESSEL'S COI.
Condition: Unknown
Due 1 June 2001
Resolved 12 June 2001
Lifesaving
Issued 18 May 2001
Resolved
PROVIDE RETRO TAPE FOR VESSEL RING BUOY.
Condition: Unknown
Due 1 June 2001
Resolved 12 June 2001
Construction/Loadline
Issued 22 January 2001
Resolved
MAKE THE PORT AND STBD PONTOON AVAILABLE FOR INSPECTION BY REMOVING ALL PAINT FROM THE PONTOONS.
Condition: Unknown
Due 22 January 2001
Resolved 22 January 2001
Fire Fighting
Issued 2 May 2000
Resolved
PROVIDE 1 BI & 1 BII FIRE EXTINGUISHERS PRIOR TO OPERATING VESSEL.
Condition: Unknown
Due 24 May 2000
Resolved 24 May 2000
Engineering
Issued 2 May 2000
Resolved
RELABLE FUEL EMERGENCY SHUT-OFF.
Condition: Unknown
Due 24 May 2000
Resolved 24 May 2000
Lifesaving
Issued 2 May 2000
Resolved
RENEW RINGBUOY PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 24 May 2000
Resolved 24 May 2000
Lifesaving
Issued 2 May 2000
Resolved
PROVIDE AN OPERABLE WATERLIGHT FOR THE RINGBUOY. (DAYLIGHT OPS ONLY.)
Condition: Unknown
Due 24 May 2000
Resolved 24 May 2000
Accommodation/Occupational Safety
Issued 9 March 1999
Resolved
REWELD/REBOLT DAMAGED AREAS OF RAIS, MAIN DECK.
Condition: Unknown
Due 9 April 1999
Resolved 10 May 1999
Construction/Loadline
Issued 9 March 1999
Resolved
REWELD CRACKED AREAS OF SPLASH GUARD, STBD PONTOON.
Condition: Unknown
Due 9 April 1999
Resolved 10 May 1999
Lifesaving
Issued 14 May 1998
Resolved
CONDUCT DRILLS AS FOLLOWS; MAN OVERBOARD, FIRE, ABANDON SHIP.
Condition: Unknown
Due 22 May 1998
Resolved 27 June 1998
Lifesaving
Issued 14 May 1998
Resolved
PROVIDE 9 ADULT PFDs. VESSEL LTD TO 26 PASSENRGERS AND 28 TOTAL PERSONS UNTIL CLEARED.
Condition: Unknown
Due 22 May 1998
Resolved 27 June 1998
Unknown
Issued 14 May 1998
Resolved
POST OIL POLLUTION PLACARD.
Condition: Unknown
Due 22 May 1998
Resolved 27 June 1998
Unknown
Issued 14 May 1998
Resolved
PROVIDE SUPERVISOR TRAINING FOR VESSELS CREW.
Condition: Unknown
Due 22 May 1998
Resolved 27 June 1998
Deck/Cargo
Issued 14 May 1998
Resolved
PROVIDE AND INSTALL A NEW CLEAT AT THE STBD QTR.
Condition: Unknown
Due 22 May 1998
Resolved 27 June 1998
Unknown
Issued 14 May 1998
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 22 May 1998
Resolved 27 June 1998
Lifesaving
Issued 14 May 1998
Resolved
POST PFD INSTRUCTIONS.
Condition: Unknown
Due 22 May 1998
Resolved 27 June 1998
Unknown
Issued 14 May 1998
Resolved
POST MARPOL V PLACARD.
Condition: Unknown
Due 22 May 1998
Resolved 27 June 1998
Construction/Loadline
Issued 19 April 1997
Resolved
STRAIGHTEN AND FAIR SPRAY RAILS ON PORT AND STBD PONTOONS PRIOR TO SAILING VESSEL FOR 1997 SEASON.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Electrical
Issued 21 June 1996
Resolved
REPLACE EXISTING WIRING WITH 14 AWG MARINE GRADE WIRING.
Condition: Unknown
Due 21 June 1996
Resolved 21 June 1996
Engineering
Issued 21 June 1996
Resolved
DOUBLE CLAMP ALL FUEL LINES AS PER 46 CFR 182.330
Condition: Unknown
Due 21 June 1996
Resolved 21 June 1996
Lifesaving
Issued 9 August 1994
Resolved
Stencil pfds with vessels name.
Condition: Unknown
Due 9 August 1994
Resolved 9 August 1994
Lifesaving
Issued 9 August 1994
Resolved
Provide 1 adult pfd, total persons reduced to 36 until complete.
Condition: Unknown
Due 9 August 1994
Resolved 9 August 1994
Lifesaving
Issued 7 July 1993
Resolved
Provide 6 smoke distress signals.
Condition: Unknown
Due 7 July 1993
Resolved 7 July 1993
Engineering
Issued 7 July 1993
Resolved
Provide suitable protection to prevent puncture of both fuel tanks.
Condition: Unknown
Due 7 July 1993
Resolved 7 July 1993
Construction/Loadline
Issued 7 July 1993
Resolved
Reattach rub rail port side aft area.
Condition: Unknown
Due 7 July 1993
Resolved 7 July 1993
Lifesaving
Issued 7 July 1993
Resolved
Provide 2 additional child pfd's and 26 additional adult pfd's.
Condition: Unknown
Due 7 July 1993
Resolved 7 July 1993
Accommodation/Occupational Safety
Issued 9 July 1992
Resolved
Permanently secure 9 additional passenger seats. Limited to 26 passengers until complete.
Condition: Unknown
Due 9 July 1992
Resolved 9 July 1992
Documentation
Issued 26 August 1991
Resolved
PROVIDE FCC STATION LICENSE.
Condition: Unknown
Due 26 August 1991
Resolved 26 August 1991
Documentation
Issued 26 August 1991
Resolved
POST STABILITY LETTER UPON RECEIPT.
Condition: Unknown
Due 26 August 1991
Resolved 26 August 1991
Construction/Loadline
Issued 11 July 1990
Resolved
PROVIDE CAPTIVE DEVICE FOR PONTOON ACCESS PLUGS.
Condition: Unknown
Due 11 July 1990
Resolved 11 July 1990
Lifesaving
Issued 11 July 1990
Resolved
PROVIDE 60' RING BUOY LINE.
Condition: Unknown
Due 11 July 1990
Resolved 11 July 1990
Deck/Cargo
Issued 11 July 1990
Resolved
PROVIDE HAND BILGE PUMP.
Condition: Unknown
Due 11 July 1990
Resolved 11 July 1990
Documentation
Issued 11 July 1990
Resolved
PROVIDE FCC RADIOTELEPHONY CERTIFICATE IF ROUTE IS TO BE OVER 1000' FROM SHORE.
Condition: Unknown
Due 11 July 1990
Resolved 11 July 1990
Lifesaving
Issued 11 July 1990
Resolved
PROVIDE W.T. FLARE BOX.
Condition: Unknown
Due 11 July 1990
Resolved 11 July 1990
Documentation
Issued 12 July 1989
Resolved
DRYDOCK DUE 12JAN91. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS INSPECTION.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Lifesaving
Issued 12 July 1989
Resolved
PROVIDE WATERTIGHT BOX FOR FLARES PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Documentation
Issued 12 July 1989
Resolved
PROVIDE A COPY OF FCC RADIO STATION LICENSE AND RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Accommodation/Occupational Safety
Issued 12 July 1989
Resolved
INSTALL SCREENING ON ALL RAILINGS FROM TOP RAIL SOWN, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Documentation
Issued 12 July 1989
Resolved
POST THE STABILITY LETTER UPON RECEIPT FROM USCG TAMPA.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Lifesaving
Issued 12 July 1989
Resolved
STENCIL PFD'S AND RING BUOY WITHY VESSEL'S NAME PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Engineering
Issued 12 July 1989
Resolved
INSTALL PERMANENT SUPPORTS FOR FUEL LINES CHAFFING ON SEWAGE TNAKS AND ENGINE CONNECTING BAR PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989