Records from 1989 to 2002. Most recent: inspection, 10 January 2002.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Electrical › Lighting (service) › Lighting Fixture
Issued 28 December 2001
Resolved
Remove naked lights or install properly on hydraulic motors in steering compartment and forepeak hydraulic room.
Condition: Improper/Lack of Maintenance
Due 28 January 2002
Resolved 4 January 2002
Resolution: CORRECTED
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 28 December 2001
Resolved
Provide Class report for Oily Water Separator prior to departure.
Action required: 705 - Other - as specified
Due 29 December 2001
Resolved 4 January 2002
Resolution: CORRECTED
Pollution Prevention/Response › Prevention Equipment
Issued 28 December 2001
No resolution recorded
Provide containment around all fuel oil and lube oil vents as well as sludge transfer connection point located on poop deck port/ starboard. Within 30 days LEGACY COMPONENT DESC: Fixed Containment
Due 28 January 2002 — due date passed with no resolution recorded
Construction/Loadline › Hull › Bracket
Issued 28 December 2001
Resolved
Repair starboard forward bracket #6 cargo hold coaming, wasted at toe. Provide Class report prior to departure. Repair within 30 days.
Action required: 705 - Other - as specified
Due 28 January 2002
Resolved 4 January 2002
Resolution: CORRECTED
Construction/Loadline › Hull › Bracket
Issued 28 December 2001
Resolved
Repair port/ starboard forward brackets #4 cargo hold coaming. Provide Class report prior to departure. Repair within 30 days.
Action required: 705 - Other - as specified
Due 28 January 2002
Resolved 4 January 2002
Resolution: CORRECTED
Construction/Loadline › Hull
Issued 28 December 2001
Resolved
Provide Class report on doubler starboard side crane house, between # 3 and # 4 cargo holds, and doubler between # 1 hold and mast house starboard side. Prior to departure. LEGACY COMPONENT DESC: Stiffener
Action required: 705 - Other - as specified
Due 29 December 2001
Resolved 4 January 2002
Resolution: CORRECTED
Electrical › Electrical Distribution System (service) › Junction Box
Issued 28 December 2001
Resolved
Remove electrical wires from winch control panel in crane house for portable welding machine, provide proper junction box and breaker.
Condition: Improper/Lack of Maintenance
Due 28 January 2002
Resolved 4 January 2002
Resolution: CORRECTED
Construction/Loadline › Hull › Bracket
Issued 28 December 2001
Resolved
Starboard aft bracket fractured, #3 cargo hold coaming. Repair to satsfaction of class prior to departure.
Action required: 705 - Other - as specified
Due 29 December 2001
Resolved 4 January 2002
Resolution: CORRECTED
Fire Fighting › Fire Main › Condition
Issued 28 December 2001
Resolved
Repair leak in firemain, in way of # 3 cargo hold starboard side. Repair prior to departure.
Action required: 705 - Other - as specified
Due 29 December 2001
Resolved 4 January 2002
Resolution: CORRECTED
Fire Fighting › Fire Main › Condition
Issued 28 December 2001
Resolved
Repair firemain leak in way of # 2 cargo hold starboard side. Repair prior to departure.
Action required: 705 - Other - as specified
Due 29 December 2001
Resolved 4 January 2002
Resolution: CORRECTED
Engineering › Sea-water System (primary cooling) › Piping
Issued 28 December 2001
Resolved
Repair ballast piping leak at elbow, in way of # 3 cargo hold starboard aft. Repair prior to departure.
Action required: 705 - Other - as specified
Due 29 December 2001
Resolved 4 January 2002
Resolution: CORRECTED
Engineering › Sea-water System (primary cooling) › Piping
Issued 28 December 2001
Resolved
Repair leak in ballast piping, in way of # 2 cargo hold starboard side. Repair to departure.
Action required: 705 - Other - as specified
Due 29 December 2001
Resolved 4 January 2002
Resolution: CORRECTED
Construction/Loadline › Hull › Weld
Issued 28 December 2001
Resolved
Repair damaged rungs on starboard liferail, in way of # 2 and # 3 cargo holds. Repair prior to departure.
Action required: 705 - Other - as specified
Due 29 December 2001
Resolved 4 January 2002
Resolution: CORRECTED
Construction/Loadline › Markings › Load Line Mark
Issued 28 December 2001
Resolved
Permanently affix loadline port and starboard side, prior to departure.
Action required: 705 - Other - as specified
Due 29 December 2001
Resolved 4 January 2002
Resolution: CORRECTED
Operations/Management › Vessel Safety Management
Issued 28 December 2001
Resolved
The Company and Vessel has failed to fully implement the requirements of SOLAS 74 AMD CH-IX, ISM code. Conduct an external audit within 72 hours. LEGACY COMPONENT DESC: Documentation Maintenance/Control
Action required: 705 - Other - as specified
Due 31 December 2001
Resolved 4 January 2002
Accommodation/Occupational Safety
Issued 6 December 1999
Resolved
PRIOR TO 06JAN00 ADJUST STAIRTOWER DOORS TO ENSURE PROPER CLOSURE.
Condition: Unknown
Due 6 January 2000
Resolved 10 December 1999
Fire Fighting
Issued 6 December 1999
Resolved
PRIOR TO DEPARTURE REPAIR FIRE MAIN STARBOARD SIDE BY CARGO HOLD #2. PROVIDE TEMPORARY OR PERMANENT REPAIR TO FIRE MAIN TO SATISFACTION OF CLASS.
Condition: Unknown
Due 6 December 1999
Resolved 7 December 1999
Electrical
Issued 6 December 1999
Resolved
PRIOR TO 06JUN00 PROVIDE RUBBER MATTING IN FRONT OF ELECTRICAL PANEL IN ENGINE CONTROL ROOM.
Condition: Unknown
Due 6 June 2000
Resolved 7 December 1999
Fire Fighting
Issued 6 December 1999
Resolved
PRIOR TO DEPARTURE DEMONSTRATE SATISFACTORY FIRE DRILL TO USCG.
Condition: Unknown
Due 6 December 1999
Resolved 7 December 1999