MAURY USCG vessel records Sign in
← All vessels

AGAPI

AGAPI is a 1978 freight ship. The Coast Guard has recorded 6 inspections since 1989, most recently in January 2002, along with 19 deficiencies — 1 with no resolution recorded —.

Records from 1989 to 2002. Most recent: inspection, 10 January 2002.

Built
1978
Last inspected
10 January 2002
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7525700 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
334169
Flag
DENMARK
—
Maury page id
psix-334169

Inspections, by type

…with no type recorded5
…past their stated due date1
Years with a record 6 calendar years (1989–2002)
The 6 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it19820 - Regulatory (Subpart C or D), Gross Ton
12725 - Regulatory (Subpart C or D), Net Ton
34290 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 6

10 January 2002 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1477274
6 December 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 435517
31 August 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 419763
17 March 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 401302
29 February 1996 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 388346
10 July 1989 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 331324

Deficiency record · 19

Electrical › Lighting (service) › Lighting Fixture
Issued 28 December 2001 Resolved
Remove naked lights or install properly on hydraulic motors in steering compartment and forepeak hydraulic room.
Condition: Improper/Lack of Maintenance
Due 28 January 2002
Resolved 4 January 2002
Resolution: CORRECTED
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 28 December 2001 Resolved
Provide Class report for Oily Water Separator prior to departure.
Action required: 705 - Other - as specified
Due 29 December 2001
Resolved 4 January 2002
Resolution: CORRECTED
Pollution Prevention/Response › Prevention Equipment
Issued 28 December 2001 No resolution recorded
Provide containment around all fuel oil and lube oil vents as well as sludge transfer connection point located on poop deck port/ starboard. Within 30 days LEGACY COMPONENT DESC: Fixed Containment
Due 28 January 2002 — due date passed with no resolution recorded
Construction/Loadline › Hull › Bracket
Issued 28 December 2001 Resolved
Repair starboard forward bracket #6 cargo hold coaming, wasted at toe. Provide Class report prior to departure. Repair within 30 days.
Action required: 705 - Other - as specified
Due 28 January 2002
Resolved 4 January 2002
Resolution: CORRECTED
Construction/Loadline › Hull › Bracket
Issued 28 December 2001 Resolved
Repair port/ starboard forward brackets #4 cargo hold coaming. Provide Class report prior to departure. Repair within 30 days.
Action required: 705 - Other - as specified
Due 28 January 2002
Resolved 4 January 2002
Resolution: CORRECTED
Construction/Loadline › Hull
Issued 28 December 2001 Resolved
Provide Class report on doubler starboard side crane house, between # 3 and # 4 cargo holds, and doubler between # 1 hold and mast house starboard side. Prior to departure. LEGACY COMPONENT DESC: Stiffener
Action required: 705 - Other - as specified
Due 29 December 2001
Resolved 4 January 2002
Resolution: CORRECTED
Electrical › Electrical Distribution System (service) › Junction Box
Issued 28 December 2001 Resolved
Remove electrical wires from winch control panel in crane house for portable welding machine, provide proper junction box and breaker.
Condition: Improper/Lack of Maintenance
Due 28 January 2002
Resolved 4 January 2002
Resolution: CORRECTED
Construction/Loadline › Hull › Bracket
Issued 28 December 2001 Resolved
Starboard aft bracket fractured, #3 cargo hold coaming. Repair to satsfaction of class prior to departure.
Action required: 705 - Other - as specified
Due 29 December 2001
Resolved 4 January 2002
Resolution: CORRECTED
Fire Fighting › Fire Main › Condition
Issued 28 December 2001 Resolved
Repair leak in firemain, in way of # 3 cargo hold starboard side. Repair prior to departure.
Action required: 705 - Other - as specified
Due 29 December 2001
Resolved 4 January 2002
Resolution: CORRECTED
Fire Fighting › Fire Main › Condition
Issued 28 December 2001 Resolved
Repair firemain leak in way of # 2 cargo hold starboard side. Repair prior to departure.
Action required: 705 - Other - as specified
Due 29 December 2001
Resolved 4 January 2002
Resolution: CORRECTED
Engineering › Sea-water System (primary cooling) › Piping
Issued 28 December 2001 Resolved
Repair ballast piping leak at elbow, in way of # 3 cargo hold starboard aft. Repair prior to departure.
Action required: 705 - Other - as specified
Due 29 December 2001
Resolved 4 January 2002
Resolution: CORRECTED
Engineering › Sea-water System (primary cooling) › Piping
Issued 28 December 2001 Resolved
Repair leak in ballast piping, in way of # 2 cargo hold starboard side. Repair to departure.
Action required: 705 - Other - as specified
Due 29 December 2001
Resolved 4 January 2002
Resolution: CORRECTED
Construction/Loadline › Hull › Weld
Issued 28 December 2001 Resolved
Repair damaged rungs on starboard liferail, in way of # 2 and # 3 cargo holds. Repair prior to departure.
Action required: 705 - Other - as specified
Due 29 December 2001
Resolved 4 January 2002
Resolution: CORRECTED
Construction/Loadline › Markings › Load Line Mark
Issued 28 December 2001 Resolved
Permanently affix loadline port and starboard side, prior to departure.
Action required: 705 - Other - as specified
Due 29 December 2001
Resolved 4 January 2002
Resolution: CORRECTED
Operations/Management › Vessel Safety Management
Issued 28 December 2001 Resolved
The Company and Vessel has failed to fully implement the requirements of SOLAS 74 AMD CH-IX, ISM code. Conduct an external audit within 72 hours. LEGACY COMPONENT DESC: Documentation Maintenance/Control
Action required: 705 - Other - as specified
Due 31 December 2001
Resolved 4 January 2002
Accommodation/Occupational Safety
Issued 6 December 1999 Resolved
PRIOR TO 06JAN00 ADJUST STAIRTOWER DOORS TO ENSURE PROPER CLOSURE.
Condition: Unknown
Due 6 January 2000
Resolved 10 December 1999
Fire Fighting
Issued 6 December 1999 Resolved
PRIOR TO DEPARTURE REPAIR FIRE MAIN STARBOARD SIDE BY CARGO HOLD #2. PROVIDE TEMPORARY OR PERMANENT REPAIR TO FIRE MAIN TO SATISFACTION OF CLASS.
Condition: Unknown
Due 6 December 1999
Resolved 7 December 1999
Electrical
Issued 6 December 1999 Resolved
PRIOR TO 06JUN00 PROVIDE RUBBER MATTING IN FRONT OF ELECTRICAL PANEL IN ENGINE CONTROL ROOM.
Condition: Unknown
Due 6 June 2000
Resolved 7 December 1999
Fire Fighting
Issued 6 December 1999 Resolved
PRIOR TO DEPARTURE DEMONSTRATE SATISFACTORY FIRE DRILL TO USCG.
Condition: Unknown
Due 6 December 1999
Resolved 7 December 1999

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.