Records from 2016 to 2026. Most recent: inspection, 26 May 2026.
Documentation record
Registered dimensions (L × B × D)42.7 ft × 13.0 ft × 5.6 ft
Registered tonnagegross 20 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHULL'S UNLIMITED-EAST INC · DELTAVILLE, VA, UNITED STATES · built 1989
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portDELTAVILLE, VA
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 11 November 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Simplified, Gross Ton
16 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 18
26 May 2026
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8380911
8 December 2025
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8300171
23 October 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8257755
10 October 2024
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8004060
26 March 2024
Hull Examination · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7885315
11 October 2023
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7806993
20 September 2022
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7553787
7 September 2022
Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7553810
21 October 2021
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7335190
27 October 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7084108
14 April 2020
Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6938767
18 November 2019
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6829504
3 October 2018
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6550924
20 March 2018
Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6372856
15 November 2017
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6307603
18 September 2017
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6269531
1 June 2016
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5894383
1 June 2016
Initial Certification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5894417
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 October 2025
Resolved
Flexible nonmetallic hose may be used in lube oil, fuel oil and fluid power systems, subject to the following requirements: Flexible hose must be fabricated with an inner tube and a cover of synthetic rubber or other suitable material reinforced with wire braid; Flexible hose runs must be visible, easily accessible, protected from mechanical damage. Vessel has 02 hoses that are damaged, one needs to be replaced and one needs protective material to keep from rubbing against machinery.
46 CFR 182.720 (e)(3) (ii)&(iii)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2026
Resolution: During DD/ISE MI identified a new engine installed with new hoses.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 23 October 2025
Resolved
The name of a vessel must be marked or painted in clearly legible letters and numbers: On each life float and buoyant apparatus. The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. Vessel name not on life float.
46 CFR 185.604 (a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2025
Resolved 16 December 2025
Resolution: Received objective evidence and uploaded to this activity clearing deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 23 October 2025
Resolved
The name of a vessel must be marked or painted in clearly legible letters and number. The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. The vessels name is not on paddles.
46 CFR 185.604(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2025
Resolved 16 December 2025
Resolution: Received objective evidence and uploaded to this activity clearing deficiency.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 10 October 2024
Resolved
A hatch exposed to the weather must be watertight. The aft hatch gasket must be replaced due to deterioration.
46 CFR 179.360(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2024
Resolved 3 December 2024
Resolution: Received photo evidence of rectification.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 12 October 2023
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Vessels emergency instructions onboard were unsat.
46 CFR 185.510(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2023
Resolved 6 December 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 October 2023
Resolved
Extinguisher retention device designed to mount and secure a specific extinguisher model onto various surfaces by incorporating releasable straps or bands to secure the fire extinguisher. Bracket was corroded and not securely fixed.
NFPA 10-3.3.11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2023
Resolved 6 December 2023
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 12 October 2023
Resolved
A pre-engineered fixed gas fire extinguishing system must...Be installed in accordance with the manufacturer's instructions. The maintenance pin was still positioned in the maintenance pin hole. Contacted ACI and notified them of the status, directed to correct on the spot.
46 CFR 181.420 (a)(4)
Action required: 10 - Deficiency Rectified
Due 12 October 2023
Resolved 12 October 2023
Resolution: Corrected on the spot.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 18 September 2017
Resolved
Deck hand without pre employment testing
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 16 November 2017
Resolution: Deckhand was pre-employment tested under Maritime Consortium