GENE BURAS ELEVATOR

GENE BURAS ELEVATOR is a 1989 offshore supply vessel. The Coast Guard has recorded 45 inspections since 1989, most recently in January 2023, along with 100 deficiencies and 1 casualty investigation in 2018.

Records from 1989 to 2023. Most recent: inspection, 20 January 2023.

Built
1989
Last inspected
20 January 2023
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB5567
334597
Flag
UNITED STATES
366911050 (licence lapsed)
Maury page id
psix-334597

Inspections, by type

…with no type recorded7
Years with a record 29 calendar years (1989–2023)
The 45 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)63.1 ft × 40.1 ft × 5.8 ft
Registered tonnagegross 98 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderELEVATING BOATS, INC · BRAITHWAITE, LA, UNITED STATES · built 1989
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 June 2026 · expires 30 June 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDB5567MMSI 366911050 · expired · voluntarily equipped · granted 25 October 2003, cancelled 28 December 2013
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 45

20 January 2023 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7624062
18 October 2021 Annual Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7334948
1 October 2020 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7068604
19 August 2019 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6788484
1 August 2019 Administrative Inspection · Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6769876
13 September 2018 Deficiency Check · Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6554990
13 September 2018 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6563951
22 May 2018 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6420887
15 February 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6379449
8 November 2017 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6303371
7 November 2016 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6036967
7 October 2016 Hull Examination · Examination of Repairs · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6021340
16 August 2011 Deficiency Check · Internal Structural Exam · Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4113470
26 October 2010 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3877374
17 July 2009 Re-Inspection · Examination of Repairs · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3537213
18 December 2008 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3381770
16 October 2007 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3081208
13 June 2006 Examination of Repairs · Hull Examination · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2678152
19 October 2005 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2518771
9 July 2004 Examination of Repairs · Re-Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2126056
30 September 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1917175
9 October 2002 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1687151
25 June 2001 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1425155
23 February 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1046851
20 August 1998 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1418387
15 November 1997 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1439932
15 August 1996 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1367887
1 December 1995 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 872945
11 August 1995 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1367475
24 August 1994 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1174466
17 August 1994 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1356732
5 January 1994 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 850991
22 July 1993 Inclining Experiment
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1428239
5 February 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 947944
22 January 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 117646
22 January 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 666032
26 September 1991 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1254044
13 September 1991 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 666047
22 July 1991 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 666046
2 July 1991 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1353156
25 June 1991 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 910586
2 May 1991 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1234966
19 December 1990 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 904584
4 December 1990 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 905668
26 July 1989 Hull Examination · Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 886826

Deficiency record · 100

05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 20 January 2023 Resolved
Vessel must comply with applicable radio regulations in 47 CFR part 80. Both radios could not switch to 22A; to be serviced.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 March 2023
Resolution: Vessel replaced antennas/ wiring; Conducted radio check with SCC NOLA, sat
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 20 January 2023 Resolved
Vessel shall be prepared for visual inspection of all accessible parts of exterior portion of hull to include railings and bulwarks; Port and bow towers have severe corrosion and port tower has broken railing; to be repaired.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 March 2023
Resolution: Vessel replaced port and bow towers and port railing; sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 January 2023 Resolved
A portable electric firepump must be constructed in compliance with subchapter J; electrical cable on submersible firepump beginning to wear; to be repaired.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 March 2023
Resolution: Vessel repaired submersible fire pump with watertight sealant, sat.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 20 January 2023 Resolved
Each lighting fixture must be fixed; Emergency light in starboard machinery space suspended by zip ties.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 March 2023
Resolution: Light fuse box installed to replace zip ties, sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 January 2023 Resolved
There are to be guards around rotating machinery; Guard over starboard main broken; to be repaired.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 March 2023
Resolution: Vessel replaced guard over starboard main, sat.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 22 October 2021 Resolved
The lifefloat shall be stowed in such a way that it runs out freely when the lifefloat floats away from the vessel. There is no weak link attached to the 8 person lifefloat. The retro-reflective tape needs to be replaced. The grab lines need to be made in bits. (Old T 46CFR180.15)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 October 2021
Resolution: Verified repair.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 22 October 2021 Resolved
An inspection shall be made for major repairs and alterations. On the aft water tank there is a soft patch that needs to be replaced. All drydock and ISE repairs need to be NDT witnessed by a MI prior to departure. (Old T 46CFR176.20-5)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 October 2021
Resolution: Received photographs of the NDT testing.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 22 October 2021 Resolved
Portable fire extinguishers shall be installed to the satisfaction of the [name withheld] fire extinguisher was found undercharged. The two extinguishers in the crew quarters and deckhand space need brackets and correct numbering and labeling system for all fire extinguishers on board. (Old T 46CFR181.30-10)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 October 2021
Resolution: Verified repair.
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 22 October 2021 Resolved
the discharge ends of vent pipes shall be provided with flame screens. There is a hole in the port side crane vent tube. (Old T 46CFR182.20-35)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 October 2021
Resolution: Reviewed photographs of replacement.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 22 October 2021 Resolved
Lighting shall be installed and meet the UL standards. There is a fluorescent bulb that is burnt out in the entrance to the bridge and also in the port side of the engine room. (Old T 46CFR183.05-50)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 October 2021
Resolution: Verified repair.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 October 2021 Resolved
The fire pump shall be self-priming and be of such size to produce an effective stream from the pump. The gauge was replaced on the fire pump for the submersible. The gauge operation was witnessed at 60 psi. (Old T 46CFR181.10)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 22 October 2021
Resolution: Corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 October 2020 Resolved
Hydraulic Hose on STBD Main Engine is worn and needs replaced
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2020
Resolved 2 October 2020
Resolution: Hose replaced in kind prior to completed of inspection
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 October 2020 Resolved
Lagging in Engine Room needs replaced
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2020
Resolved 12 October 2020
Resolution: Lagging was replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 October 2020 Resolved
Clamps missing off Port Engine and Bilge piping
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 October 2020
Resolved 2 October 2020
Resolution: Clamps were placed on hoses and bildge prior to completion of inspection
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 October 2020 Resolved
Sead end wires exposed on Port Engine
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 October 2020
Resolved 2 October 2020
Resolution: Dead end wire was secured prior to completion of inspection
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 August 2019 Resolved
Port generator would not start. Demonstrate generator works properly.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 August 2019
Resolved 21 August 2019
Resolution: Civ Landry witnessed generator start and running. Witnessed overspeed test, sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 19 August 2019 Resolved
Identified 02 damaged lifefloats. Replace with serviceable floats for full capacity of vessel.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 August 2019
Resolved 21 August 2019
Resolution: Two (02) new lifefloats installed and a third lifefloat was added. Vsl now has more lifefloat capacity than required by COI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 September 2018 Resolved
2 pulleys on each engine port and stbd which spin when engines are running had no guards over the pulleys
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 September 2018
Resolution: Inspector visited vessel and witnessed guards over all pulleys
Construction/Loadline › Hull › Hull Plating
Issued 22 May 2018 Resolved
Complete 10yr leg pull in accordance with policy ltr 07-02 on all legs prior to 31Aug18
Action required: 705 - Other - as specified
Due 31 August 2018
Resolved 23 October 2018
Fire Fighting › Fire Pumps › Location
Issued 16 August 2011 Resolved
Renew submersible fire pump davit wheel
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2011
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 August 2011 Resolved
Place machinery guards over rotating machinery on both generators.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2011
Fire Fighting › Means of Escape › Emergency Lighting
Issued 16 August 2011 Resolved
Reconnect emergency lighting in P/S engine rooms
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2011
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 16 August 2011 Resolved
Place proper cover over engine room electrical cover.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2011
Fire Fighting › Remote Fuel Shutoff › General
Issued 16 August 2011 Resolved
Properly mark deck enmergency fuel shutoffs
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2011
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 16 August 2011 Resolved
Place blanks in spare slots in galley electrical breaker box.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2011
Stability › Watertight Integrity › General
Issued 16 August 2011 Resolved
Repalce wasted soft gasketsd on engine room hatches with hard gasket.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2011
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 17 July 2009 Resolved
Repair/renew loose and missing exhaust lagging on port MDE.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 July 2009
Construction/Loadline › Penetrations › Valve Flange
Issued 17 July 2009 Resolved
Install a check valve on stbd grey water drain line.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 July 2009
Engineering › Fuel Oil Service System › Filter
Issued 17 July 2009 Resolved
Properly mount loose fuel filter on port MDE.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 July 2009
Fire Fighting › Means of Escape › Emergency Lighting
Issued 17 July 2009 Resolved
Demonstrate proper operation of e-lights on port side of wheelhouse and stbd aft of wheelhouse.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 July 2009
Construction/Loadline › Structures › Deck Plating
Issued 17 July 2009 Resolved
Crop and renew pipe penetration on deck aft of the port crane base.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 July 2009
Electrical › Lighting (emergency) › Lighting Branch Circuit
Issued 18 December 2008 Resolved
Emergency lighting system not operating and lights not marked
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2009
Resolution: Emergency lighting system repaired and lights marked as required.
Construction/Loadline › Penetrations › Gasket
Issued 18 December 2008 Resolved
No gasket in emergency escape hatch cover in crew lounge area.
Due 19 January 2009
Resolved 19 December 2008
Resolution: New gasket installed in hatch cover
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 18 December 2008 Resolved
Smoke detectors missing from brackets.
Due 19 January 2009
Resolved 18 December 2008
Resolution: Smoke detectors replaced and proper operation demonstrated prior to end of inspection.
Communications › Audible Communications › SPD (Other)
Issued 18 December 2008 Resolved
Vessel's jacking tilt alarm not operating.
Action required: 705 - Other - as specified
Due 19 January 2009
Resolved 19 December 2008
Resolution: Proper operation of Tilt alarm demonstrated to inspector.
Construction/Loadline › Structures › Door
Issued 18 December 2008 Resolved
Watertight door in engine room not operating properly.
Action required: 705 - Other - as specified
Resolved 19 December 2008
Resolution: Proper operation of watertight door demonstrated to inspector
Construction/Loadline › Structures › Transverse Bulkhead
Issued 18 December 2008 Resolved
Penetrations through bulkheads were not watertight.
Action required: 705 - Other - as specified
Resolved 19 December 2008
Resolution: Penetrations through bulkhead were made watertight
Construction/Loadline › Structures › Transverse Bulkhead
Issued 18 December 2008 Resolved
Penetrations through bulkheads were not watertight.
Action required: 705 - Other - as specified
Resolved 19 December 2008
Resolution: Penetrations through bulkhead were made watertight
Navigation › Piloting/Steering › Magnetic Compass
Issued 18 December 2008 Resolved
Magnetic compass light not operating
Action required: 705 - Other - as specified
Resolved 18 December 2008
Resolution: Proper operation of compass light demonstrated
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 18 December 2008 Resolved
Renew lagging on port MDE
Action required: 705 - Other - as specified
Resolved 19 December 2008
Resolution: New lagging installed.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 18 December 2008 Resolved
Required portable lighting not available at control station or engine room entrance
Action required: 705 - Other - as specified
Resolved 19 December 2008
Resolution: Portable light provided at control station and engine room
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 18 December 2008 Resolved
Goose neck vents from engine room had no means of closure for fire fighting
Action required: 705 - Other - as specified
Resolved 19 December 2008
Resolution: Vent closures attached to vents.
Fire Fighting › Remote Fuel Shutoff › General
Issued 18 December 2008 Resolved
Renew or repair emergency fuel shutoff valves on stbd side
Action required: 705 - Other - as specified
Resolved 19 December 2008
Resolution: Linkage repaired on emergency fuel shutoff
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 18 December 2008 Resolved
Hull markings not painted in contrasting color
Action required: 705 - Other - as specified
Resolved 19 December 2008
Resolution: Hull markings painted in contrasting color
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 18 December 2008 Resolved
Location of stove disconnect breaker not labeled
Action required: 705 - Other - as specified
Resolved 19 December 2008
Resolution: Location of stove disconnect breaker labeled
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 16 October 2007 Resolved
Overspeed devices failed to shutdown engine when tested.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 October 2007
Resolution: Overseed devices repaired and tested satisfactorily.
Lifesaving › Lifefloat › Float-free Link
Issued 16 October 2007 Resolved
Float free links were unservicable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 October 2007
Resolution: New float free links were installed.
Fire Fighting › Means of Escape › Blocked
Issued 16 October 2007 Resolved
Secondary escape route blocked by company radio wires.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 October 2007
Resolution: Wires were rerouted to stand alone kick pipe and riser.
Deck/Cargo › Cargo Stowage › General
Issued 19 October 2005 Resolved
Relocate portable welding machine. Current location is above allowed height by vessel's operating manual.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 October 2005
Resolved 20 October 2005
Resolution: Relocated to main deck.
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 19 October 2005 Resolved
Float-free link, FWD STBD B.A. is missing tag, renew with appropriate tagged link.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 October 2005
Resolution: New float-free link installed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 19 October 2005 Resolved
Renew batteries in two (02) water lights.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 October 2005
Resolution: New batteries installed. Lights operate properly.
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 October 2005 Resolved
Remove unapproved remote starting wiring, STBD main engine.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 October 2005
Resolution: Wiring removed.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 19 October 2005 Resolved
Demonstrate properation of port generator overspeed device.
Action required: 705 - Other - as specified
Due 19 November 2005
Resolved 20 October 2005
Resolution: New overspeed device installed and tested sat.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 19 October 2005 Resolved
Properly install wiring for added television satallite dish. Present wiring wrapped around ladder and across 01 deck causing tripping hazard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 November 2005
Resolved 20 October 2005
Resolution: Wiring re-routed in a manner that removed hazard of tripping personnel.
Construction/Loadline › Hull › Weld
Issued 8 July 2004 Resolved
Gouge & reweled leg guide to hull connection where cracked.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 July 2004
Resolution: Gouged and rewelded, completed sat NDT.
Personnel › Certificates/Documents/Licenses
Issued 30 September 2003 Resolved
Provide Radio Operator's Permit for master. LEGACY COMPONENT DESC: Radio Operator''s Permit
Action required: 705 - Other - as specified
Due 30 October 2003
Resolved 9 October 2003
Documentation › Certificates/Documents
Issued 30 September 2003 Resolved
Provide current FCC Station License. LEGACY COMPONENT DESC: FCC SSL
Action required: 17 - Rectify deficiencies prior to departure
Due 30 October 2003
Resolved 9 October 2003
Documentation › Manuals/Policy Documentation
Issued 30 September 2003 Resolved
Provide an Operations Manual for jack-up operations. LEGACY COMPONENT DESC: Operations Manual
Action required: 17 - Rectify deficiencies prior to departure
Due 30 October 2003
Resolved 8 October 2003
Documentation › Certificates/Documents › Stability Letter
Issued 30 September 2003 Resolved
Provide original or certified copy of the Stability Letter.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 October 2003
Resolved 9 October 2003
Documentation › Logs/Records
Issued 30 September 2003 Resolved
Log Man Overboard, Fire, Abandon ship drills, and EPIRB checks IAW 46 CFR 185.520, 185.524, and 185.728. LEGACY COMPONENT DESC: Logbook (official)
Action required: 17 - Rectify deficiencies prior to departure
Due 31 October 2003
Resolved 8 October 2003
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 September 2003 Resolved
Provide sealing grommet for stuffing tube located in the aft rake.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 October 2003
Resolved 9 October 2003
Electrical › Lighting (service) › Lighting Fixture
Issued 30 September 2003 Resolved
Provide protective cover for light fixture under the Bridge.
Action required: 705 - Other - as specified
Due 30 October 2003
Resolved 8 October 2003
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 30 September 2003 Resolved
Provide updated copies of the Local Notice to Mariners.
Action required: 705 - Other - as specified
Due 30 October 2003
Resolved 8 October 2003
Lifesaving › Lifebuoys
Issued 30 September 2003 Resolved
Renew port 01 deck and main deck float light line on lifebuoys. LEGACY COMPONENT DESC: Self-igniting Lights
Action required: 705 - Other - as specified
Due 30 October 2003
Resolved 8 October 2003
Lifesaving › Lifebuoys
Issued 30 September 2003 Resolved
Stencil 01 deck lifebuoy with vessel name and homeport. LEGACY COMPONENT DESC: Markings (ship name/port)
Action required: 705 - Other - as specified
Due 30 October 2003
Resolved 8 October 2003
Construction/Loadline › Hull
Issued 30 September 2003 Resolved
Make repairs by welding cracked crane cradle, cracked deck plate at ladder leading to main deck, and cracked frames in the stbd side Engine Room.. LEGACY COMPONENT DESC: Bracket
Action required: 705 - Other - as specified
Due 30 October 2003
Resolved 9 October 2003
Communications › Alarms/Indicators › Bilge Alarm
Issued 30 September 2003 Resolved
Make bilge alarms operable and properly label.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 October 2003
Resolved 9 October 2003
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 30 September 2003 Resolved
Remove temporary patch and make repairs to port generator overboard exhaust pipe.
Action required: 705 - Other - as specified
Due 30 October 2003
Resolved 8 October 2003
Engineering › Shafting/Propeller Arrangements
Issued 30 September 2003 Resolved
Make repairs to both kort nozzle seams. LEGACY COMPONENT DESC: Kort Nozzle
Action required: 17 - Rectify deficiencies prior to departure
Due 30 October 2003
Resolved 8 October 2003
Lifesaving › Launching Appliances
Issued 30 September 2003 Resolved
Renew marked hoses and piping on stbd deck crane and aft jacking leg. LEGACY COMPONENT DESC: Deck Crane
Action required: 705 - Other - as specified
Due 30 October 2003
Resolved 8 October 2003
Lifesaving
Issued 9 October 2002 Resolved
Restock or replace first aid kit. LEGACY COMPONENT DESC: First Aid Kit
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 October 2002
Resolution: Kit restocked.
Lifesaving › Buoyant Apparatus
Issued 9 October 2002 Resolved
Replace inoperative water light.
Action required: 705 - Other - as specified
Resolved 9 October 2002
Resolution: Light replaced.
Lifesaving
Issued 15 November 1997 Resolved
PROVIDE NEW BATTERY FOR EPIRB. VESSEL IS RESTRICTED FROM GETTING UNDERWAY UNTIL EPIRB IS OPERATIONAL AND VERIFYING DOCUMENTATION HAS BEEN SENT TO MARINE SAFETY OFFICE NEW ORLEANS.
Condition: Unknown
Due 18 November 1997
Resolved 4 May 1998
Documentation
Issued 15 November 1997 Resolved
POST RADIO STATION LICENSE ONBOARD VESSEL.
Condition: Unknown
Due 15 December 1997
Resolved 4 May 1998
Lifesaving
Issued 15 November 1997 Resolved
PROVIDE PROPER RETROREFLECTIVE TAPE AND STENCILING ON RING BUOYS AND RESCUEBOAT AS NECESSARY.
Condition: Unknown
Due 15 December 1997
Resolved 4 May 1998
Documentation
Issued 15 November 1997 Resolved
VESSEL WAS OVERDUE FOR REQUIRED REINSPECTION ON 15 AUG 97 AND MISSED 60 DAYWINDOW (15 AUG 97 - 15 OCT 97).
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Engineering
Issued 15 November 1997 Resolved
PROVE PROPER OPERATION OF MAIN DIESEL ENGINE OVERSPEED TRIPS.
Condition: Unknown
Due 15 December 1997
Resolved 4 May 1998
Documentation
Issued 15 August 1996 Resolved
POST THE VESSEL STATION BILL IN PILOTHOUSE AND IN ACCOMODATION SPACES.
Condition: Unknown
Due 15 September 1996
Resolved 18 February 1997
Documentation
Issued 15 August 1996 Resolved
PREPARE AND POST DURABLE EMERGENCY INSTRUCTION PLACARDS THROUGHOUT VESSEL.
Condition: Unknown
Due 15 September 1996
Resolved 18 February 1997
Deck/Cargo
Issued 15 August 1996 Resolved
REPLACE BOOM FOR PORT CRANE AS ORIGINAL AND CONDUCT LOAD TEST PRIOR TO PLACING IT BACK INTO SERVICE.
Condition: Unknown
Due 15 September 1996
Resolved 18 February 1997
Deck/Cargo
Issued 15 August 1996 Resolved
REPLACE OR CONDUCT PERMANENT REPAIRS TO STARBOARD AFT LEG PAD AND PROVIDE SATISFACTORY NDT REPORT/AIR TESTING REPORT PRIOR TO PLACING VESSEL BACK INTO SERVICE.
Condition: Unknown
Due 15 September 1996
Resolved 18 February 1997
Lifesaving
Issued 11 August 1995 Resolved
PROPERLY INSTALL & PROVE OPERATION OF A TILT ALARM ACCEPTABLE TO THE_x001C_ COGNIZANT OCMI.
Condition: Unknown
Due 11 August 1995
Resolved 11 August 1995
Documentation
Issued 17 August 1994 Resolved
PROVIDE ONBOARD A STABILITY LETTER AND APPROVED OPERATIONS MANUAL.
Condition: Unknown
Due 1 September 1994
Resolved 1 September 1994
Navigation
Issued 26 September 1991 Resolved
CALIBRATE MAGNETIC COMPASS AND SUBMIT DEVIATION TABLE TO [name withheld].
Condition: Unknown
Due 26 September 1991
Resolved 26 September 1991
Construction/Loadline
Issued 25 June 1991 Resolved
CROP & RENEW IN KIND DAMAGED AREA ON CENTERLINE BULKHEAD WELD CONNECTION WITH TRANSOM PLATING.
Condition: Unknown
Due 25 June 1991
Resolved 25 June 1991
Construction/Loadline
Issued 25 June 1991 Resolved
MAKE PERMANENT REPAIRS TO CRACKED WELDS ON TRANSOM PLATING ON PORT & STBD_x001C_ SIDE OF CENTERLINE BULKHEAD.
Condition: Unknown
Due 25 June 1991
Resolved 25 June 1991
Engineering
Issued 25 June 1991 Resolved
MAKE PERMANENT REPAIRS TO OIL LINES IN PORT FUEL/WATER TANK VOID & OVER IN-BOARD MSD UNIT IN STBD ENGINE ROOM TO STOP OIL LEAKS.
Condition: Unknown
Due 25 June 1991
Resolved 25 June 1991
Construction/Loadline
Issued 25 June 1991 Resolved
PERFORM VISUAL & NDT INSPECTION OF LEG TO PAD CONNECTIONS TO SATISFACTION_x001C_ OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 25 June 1991
Resolved 25 June 1991
Construction/Loadline
Issued 25 June 1991 Resolved
MAKE UNDERWATER BODY AVAILABLE FOR VISUAL EXAMINATION BY C.G. MARINE_x001C_ INSPECTOR.
Condition: Unknown
Due 25 June 1991
Resolved 25 June 1991
Construction/Loadline
Issued 25 June 1991 Resolved
MAKE PERMANENT REPAIRS TO HAND RAIL DAMAGE ON PORT & STBD SIDES OF STERN.
Condition: Unknown
Due 25 June 1991
Resolved 25 June 1991
Electrical
Issued 25 June 1991 Resolved
PROVIDE WIRING CLAMPS TO SUPPORT BATTERY CABLES IN PORT & STBD ENGINE ROOMS
Condition: Unknown
Due 25 June 1991
Resolved 25 June 1991
Deck/Cargo
Issued 25 June 1991 Resolved
MAKE PERMANENT REPAIRS TO PORT & STBD CRANES.
Condition: Unknown
Due 25 June 1991
Resolved 25 June 1991
Construction/Loadline
Issued 25 June 1991 Resolved
CROP & RENEW BENT VERT STIFFENERS ON TRANSOM, (5 PORT, 4 STBD) ON EACH SIDEOF CENTERLINE BULKHEAD, IN KIND.
Condition: Unknown
Due 25 June 1991
Resolved 25 June 1991
Construction/Loadline
Issued 25 June 1991 Resolved
CROP & RENEW IN KIND, PUNCTURE & SET-IN ON TRANSOM STBD SIDE OF CENTER LINEBULKHEAD, APPROX 4 FT FROM BOTTOM SHELL PLT.
Condition: Unknown
Due 25 June 1991
Resolved 25 June 1991
Lifesaving
Issued 26 July 1989 Resolved
PROVIDE A U.S. COAST GUARD APPROVED RESCUE BOAT OR SUBMIT AN ALTERNATE PROPOSAL FOR APPROVAL.
Condition: Unknown
Due 26 July 1989
Resolved 26 July 1989
Documentation
Issued 26 July 1989 Resolved
SUBMIT THE FOLLOWING PLANS FOR REVIEW & APPROVAL BY THE U.S. COAST GUARD MARINE SAFETY CENTER, WASHINGTON, DC. INBOARD & OUTBOARD PROFILE, LEG STRUCTURAL SUPPORT & LEG STRENGTH CRITERIA, HYDRAULIC JACKING SYSTEM DETAILS INCLUDING THE ALARMS & CONTROLS.
Condition: Unknown
Due 26 July 1989
Resolved 26 July 1989
Documentation
Issued 26 July 1989 Resolved
PROVIDE APPROVED PLANS AS REQUIRED BY ITEM #1 TO COGNIZANT OCMI.
Condition: Unknown
Due 26 July 1989
Resolved 26 July 1989
Documentation
Issued 26 July 1989 Resolved
PROVIDE A VALID CERTIFICATE OF DOCUMENTATION. ORIGINAL IS TO BE PLACE ON THE VESSEL.
Condition: Unknown
Due 26 July 1989
Resolved 26 July 1989
Documentation
Issued 26 July 1989 Resolved
SUBMIT STABILITY CALCULATIONS FOR REVIEW AND APPROVAL BY THE U.S. COAST GUARD MARINE SAFETY CENTER, WASHINGTON, DEC.
Condition: Unknown
Due 26 July 1989
Resolved 26 July 1989
Documentation
Issued 26 July 1989 Resolved
SUBMIT AN OPERATING MANUAL FOR REVIEW & APPROVAL BY THE U.S. COAST GUARD MARINE SAFETY CENTER, WASHINGTON, DC.
Condition: Unknown
Due 26 July 1989
Resolved 26 July 1989

Casualty record · 1

15 February 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 6379449
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.