Records from 2016 to 2023. Most recent: inspection, 20 January 2023.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)63.1 ft × 40.1 ft × 5.8 ft
Registered tonnagegross 98 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderELEVATING BOATS, INC · BRAITHWAITE, LA, UNITED STATES · built 1989
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 June 2026 · expires 30 June 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
12 inspections, each with its date, unit and type; 19 deficiencies with the resolution recorded against each; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 12
20 January 2023
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7624062
18 October 2021
Annual Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7334948
1 October 2020
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7068604
19 August 2019
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6788484
1 August 2019
Administrative Inspection · Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6769876
13 September 2018
Deficiency Check · Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6554990
13 September 2018
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6563951
22 May 2018
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6420887
15 February 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6379449
8 November 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6303371
7 November 2016
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6036967
7 October 2016
Hull Examination · Examination of Repairs · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6021340
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 20 January 2023
Resolved
Vessel must comply with applicable radio regulations in 47 CFR part 80. Both radios could not switch to 22A; to be serviced.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 March 2023
Resolution: Vessel replaced antennas/ wiring; Conducted radio check with SCC NOLA, sat
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 20 January 2023
Resolved
Vessel shall be prepared for visual inspection of all accessible parts of exterior portion of hull to include railings and bulwarks; Port and bow towers have severe corrosion and port tower has broken railing; to be repaired.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 March 2023
Resolution: Vessel replaced port and bow towers and port railing; sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 January 2023
Resolved
A portable electric firepump must be constructed in compliance with subchapter J; electrical cable on submersible firepump beginning to wear; to be repaired.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 March 2023
Resolution: Vessel repaired submersible fire pump with watertight sealant, sat.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 20 January 2023
Resolved
Each lighting fixture must be fixed; Emergency light in starboard machinery space suspended by zip ties.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 March 2023
Resolution: Light fuse box installed to replace zip ties, sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 January 2023
Resolved
There are to be guards around rotating machinery; Guard over starboard main broken; to be repaired.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 March 2023
Resolution: Vessel replaced guard over starboard main, sat.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 22 October 2021
Resolved
The lifefloat shall be stowed in such a way that it runs out freely when the lifefloat floats away from the vessel. There is no weak link attached to the 8 person lifefloat. The retro-reflective tape needs to be replaced. The grab lines need to be made in bits. (Old T 46CFR180.15)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 October 2021
Resolution: Verified repair.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 22 October 2021
Resolved
An inspection shall be made for major repairs and alterations. On the aft water tank there is a soft patch that needs to be replaced. All drydock and ISE repairs need to be NDT witnessed by a MI prior to departure. (Old T 46CFR176.20-5)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 October 2021
Resolution: Received photographs of the NDT testing.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 22 October 2021
Resolved
Portable fire extinguishers shall be installed to the satisfaction of the [name withheld] fire extinguisher was found undercharged. The two extinguishers in the crew quarters and deckhand space need brackets and correct numbering and labeling system for all fire extinguishers on board.
(Old T 46CFR181.30-10)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 October 2021
Resolution: Verified repair.
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 22 October 2021
Resolved
the discharge ends of vent pipes shall be provided with flame screens. There is a hole in the port side crane vent tube.
(Old T 46CFR182.20-35)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 October 2021
Resolution: Reviewed photographs of replacement.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 22 October 2021
Resolved
Lighting shall be installed and meet the UL standards. There is a fluorescent bulb that is burnt out in the entrance to the bridge and also in the port side of the engine room. (Old T 46CFR183.05-50)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 October 2021
Resolution: Verified repair.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 October 2021
Resolved
The fire pump shall be self-priming and be of such size to produce an effective stream from the pump. The gauge was replaced on the fire pump for the submersible. The gauge operation was witnessed at 60 psi. (Old T 46CFR181.10)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 22 October 2021
Resolution: Corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 October 2020
Resolved
Hydraulic Hose on STBD Main Engine is worn and needs replaced
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2020
Resolved 2 October 2020
Resolution: Hose replaced in kind prior to completed of inspection
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 October 2020
Resolved
Lagging in Engine Room needs replaced
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2020
Resolved 12 October 2020
Resolution: Lagging was replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 October 2020
Resolved
Clamps missing off Port Engine and Bilge piping
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 October 2020
Resolved 2 October 2020
Resolution: Clamps were placed on hoses and bildge prior to completion of inspection
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 October 2020
Resolved
Sead end wires exposed on Port Engine
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 October 2020
Resolved 2 October 2020
Resolution: Dead end wire was secured prior to completion of inspection
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 August 2019
Resolved
Port generator would not start. Demonstrate generator works properly.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 August 2019
Resolved 21 August 2019
Resolution: Civ Landry witnessed generator start and running. Witnessed overspeed test, sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 19 August 2019
Resolved
Identified 02 damaged lifefloats. Replace with serviceable floats for full capacity of vessel.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 August 2019
Resolved 21 August 2019
Resolution: Two (02) new lifefloats installed and a third lifefloat was added. Vsl now has more lifefloat capacity than required by COI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 September 2018
Resolved
2 pulleys on each engine port and stbd which spin when engines are running had no guards over the pulleys
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 September 2018
Resolution: Inspector visited vessel and witnessed guards over all pulleys
Construction/Loadline › Hull › Hull Plating
Issued 22 May 2018
Resolved
Complete 10yr leg pull in accordance with policy ltr 07-02 on all legs prior to 31Aug18
Action required: 705 - Other - as specified
Due 31 August 2018
Resolved 23 October 2018