Records from 1989 to 2008. Most recent: inspection, 29 January 2008.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 35
29 January 2008
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3146189
22 February 2007
Deficiency Check · In-Service Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2891646
6 April 2006
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2618378
29 March 2006
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2597694
1 March 2005
Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2301479
19 January 2005
Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2268884
20 July 2004
Annual Inspection · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2164612
28 April 2004
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2058104
16 December 2003
Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1965204
6 May 2003
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1769558
20 June 2002
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1635651
10 June 2002
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1624084
8 May 2002
Administrative Inspection · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1611885
17 April 2002
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1605717
15 April 2002
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1604917
6 March 2002
Re-Inspection · Construction Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1485953
15 April 2001
Deficiency Check · COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1440469
11 April 2001
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1422051
25 September 2000
Plan Review "T" Boat
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1455919
12 April 2000
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1439004
24 May 1999
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 806496
13 April 1999
Hull Examination · Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1444148
21 May 1998
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 792620
10 April 1998
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1442695
20 May 1997
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 775830
16 April 1997
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1435909
10 April 1996
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1438425
15 June 1995
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 878494
10 April 1995
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1167155
4 April 1994
Re-Inspection · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1167333
21 April 1993
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 834894
14 April 1992
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1269070
4 June 1991
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1009813
19 April 1991
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1212722
30 June 1989
Hull Examination · Initial Certification
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1345678
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 22 February 2007
Resolved
Proof test vessels' heat detection system prior to carrying passengers once each day of commercial use. Conduct a visual inspection fore Fire or Smoke on vessels' bilge compartment every 10 minutes while underway with passengers onboard. Upgrade vessels' Heat Detection System to include Electrical Supervision and two sources of power (vital circuit) by dates provided by your company to the OCMI.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 22 August 2007
Resolution: Company upgraded heat detection system to include electrical supervision on two ower sources.
Engineering › Gasoline Engine (propulsion) › Carburetor (4 cycle)
Issued 29 March 2006
Resolved
Properly repair fuel leak on carburetor float adjustment screw.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 29 March 2006
Resolved 29 March 2006
Engineering › Gasoline Engine (propulsion) › Exhaust Piping (4 cycle)
Issued 29 March 2006
Resolved
Properly insulate main engine exhaust manifold and piping in the engine compartment.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2006
Resolved 25 April 2006
Construction/Loadline › Hull › Bottom Plating
Issued 28 April 2004
Resolved
Crop out and replace mid section between forward and aft wheel wells and float test in the presence of the attending marine inspector. LEGACY COMPONENT DESC: Bottom Plating
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2004
Resolved 20 July 2004
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 16 December 2003
Resolved
Properly install engine space ventilation blower as per 46 CFR 182.460.
Condition: Improper Installation
Due 17 March 2004
Resolved 20 July 2004
Construction/Loadline › Hull › Hull Plating
Issued 20 June 2002
Resolved
Condition: Unknown
Due 24 June 2002
Resolved 24 June 2002
Construction/Loadline › Hull
Issued 17 April 2002
Resolved
Make proper repairs to wasted side shell near fender wells. Water test to the satisfaction of the attending Marine Inspector. LEGACY COMPONENT DESC: Side Shell
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2002
Resolved 11 June 2002
Electrical › Electric Supply System (service)
Issued 6 March 2002
Resolved
Submit plans and Bill of Materials for electrical system IAW 46 CFR 183 and NVIC 1-01.
Condition: Placed in Improper Service
Due 10 April 2002
Resolved 10 April 2002
Resolution: Verified satisfactory installation of electrical wiring.
[name withheld]
Construction/Loadline
Issued 15 April 2001
Resolved
Properly repair damaged area around the higgins pump discharge outlet.
Condition: Unknown
Due 16 April 2001
Resolved 16 April 2001
Engineering
Issued 10 April 1998
Resolved
Install fuel shut-off valve at fuel tank.
Condition: Unknown
Due 10 April 1998
Resolved 10 April 1998
Navigation
Issued 10 April 1998
Resolved
Prove proper operation of forward running lights.
Condition: Unknown
Due 10 April 1998
Resolved 10 April 1998
Lifesaving
Issued 10 April 1998
Resolved
Replace retro tape on twelve (12) adult PFDs.
Condition: Unknown
Due 10 April 1998
Resolved 10 April 1998
Construction/Loadline
Issued 10 April 1998
Resolved
Remove and properly dispose of waste oil in bilges.
Condition: Unknown
Due 10 April 1998
Resolved 10 April 1998
Fire Fighting
Issued 16 April 1997
Resolved
Prove proper hydrostatic test of fixxed FF CO2 bottle.
Condition: Unknown
Due 16 April 1997
Resolved 16 April 1997
Documentation
Issued 10 April 1995
Resolved
PROVIDE PROOF OF CURRENT VALID STATE REGISTRATION.
Condition: Unknown
Due 10 April 1995
Resolved 10 April 1995
Lifesaving
Issued 10 April 1995
Resolved
MARK STATE NUMBER ON RING BUOY.
Condition: Unknown
Due 10 April 1995
Resolved 10 April 1995
Construction/Loadline
Issued 19 April 1991
Resolved
STENCIL VESSEL NAME ON STERN.
Condition: Unknown
Due 19 April 1991
Resolved 19 April 1991