MAURY USCG vessel records Sign in
← All vessels

EXPLORER

EXPLORER is a 2001 passenger vessel (inspected). The Coast Guard has recorded 48 inspections since 2001, most recently in June 2012, along with 18 deficiencies and 1 operational control.

Records from 2001 to 2012. Most recent: inspection, 15 June 2012.

Built
2001
Last inspected
15 June 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9183518 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
BAHAMAS, THE
—
Maury page id
psix-33509

Inspections, by type

…with no type recorded27
Years with a record 12 calendar years (2001–2012)
The 48 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it24391 - Simplified, Gross Ton
24318 - Convention (Subpart B), Gross Ton
10026 - Simplified, Net Ton
10026 - Convention (Subpart B), Net Ton
2400 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 48

15 June 2012 COC-CVE Quarterly
Type not classified · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4348269
17 January 2012 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4227522
13 December 2011 COC-CVE Annual · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4206353
20 August 2011 PII Safety Exam · ISPS II Exam · COC-CVE Quarterly
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4119718
13 January 2011 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3926087
3 December 2010 COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3884428
4 December 2009 COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3646678
14 January 2009 COC-CVE Quarterly
Type not classified · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3394098
11 January 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3128489
7 January 2008 COC-CVE Quarterly · MARPOL Annex II Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3125782
11 June 2007 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2958596
26 January 2007 COC-CVE Quarterly
Type not classified · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2862380
22 August 2006 ISPS II Exam · COC-CVE Annual · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2755961
11 June 2006 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2676346
13 January 2006 ISPS II Exam · Ballast Water Examination · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2565919
12 January 2006 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2566218
8 January 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2563001
16 August 2005 MARPOL Annex I Examination · COC-CVE Annual · ISPS II Exam · ILO-147 Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2464545
31 January 2005 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2284519
31 January 2005 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2284610
31 January 2005 Type not recorded
No type recorded · USCGC WASHINGTON (WPB 1331) · USCG Oceania District (CGD-O) · Activity 2313079
26 January 2005 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2284085
14 January 2005 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2275230
12 January 2005 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2273390
7 December 2004 COC-CVE Quarterly
Type not classified · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2255226
18 June 2004 ISPS II Exam · MTSA/ISPS Verification
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2102959
14 June 2004 Certificate of Compliance
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2085169
1 June 2004 Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2085584
8 January 2004 Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1979786
24 December 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1969239
22 December 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1968684
17 December 2003 Type not recorded
No type recorded · GROUP HONOLULU · USCG Oceania District (CGD-O) · Activity 1966004
17 December 2003 Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1966511
16 December 2003 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1965182
10 December 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1961914
10 December 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1961920
8 December 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1960303
8 December 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1960939
24 November 2003 Certificate of Compliance
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1953599
7 February 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1741480
7 February 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1741642
2 February 2003 Security Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1741591
24 January 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1735066
24 January 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1735241
9 December 2002 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1716448
9 December 2002 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1716453
25 November 2002 Certificate of Compliance · Ballast Water Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1710956
12 April 2001 Type not recorded
No type recorded · Activities Europe · Activity 1362378

Deficiency record · 18

Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 15 June 2012 Resolved
0710: All waste receptables shall be constructed of non-combustible materials. Waste receptacles of combustible materials were found in the sauna, Deck 7 midship; the pool bar pantry, port side aft; and the passenger gym, port side. 74 SOLAS (01) II-2/18.5.
Action required: 705 - Other - as specified
Due 18 July 2012
Resolved 18 August 2012
Resolution: Waste receptables replaced with steel.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 15 June 2012 Resolved
Spaces are classified according to their fire risk, as shown in categories (1) to (14) in SOLAS II-2. Combustible material was found stored in the forward switchboard room on Deck 8, which is classified as a category (10) space and shall therefore not be used for storage of combustibles. 74 SOLAS (01) II-2/26.2.2
Action required: 705 - Other - as specified
Due 2 July 2012
Resolved 18 August 2012
Resolution: Combustible material was removed from the space.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 15 June 2012 Resolved
Escape routes shall be marked with symbols in accordance with the recommendations of the organization. Routes to similar muster stations shall be indicated with the muster station symbol in accordance with the recommendations of the organization. Emergency signage was not visible on deck 7 aft pool bar. 74SOLAS (09) III/11.5
Action required: 705 - Other - as specified
Due 18 July 2012
Resolved 18 August 2012
Resolution: Area has been marked with symbols leading to the muster station.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 12 December 2011 Resolved
Where the contents and use of a space are such that there is a doubt as to its classification, it shall be treated as a space within the relevant category having the most stringent boundary requirements. Found store room on deck 6 by stage area which has been separated by a false bulkhead and converted into an office area. [2001 SOLAS II-2/26.2.2]
Action required: 705 - Other - as specified
Due 27 December 2011
Resolved 19 April 2012
Resolution: Recieved Class report, issuing an outstanding Condition of Class until Fire Plan Is reissued
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 12 December 2011 Resolved
Where the contents and use of a space are such that there is a doubt as to its classification it shall be treated as a space within the relevant category hacing the most stringent boundary requirements. Found locker with more than daily use flammable liquids in the spa area. [2001 SOLAS II-2/26.2.2]
Action required: 705 - Other - as specified
Resolved 13 December 2011
Resolution: Corrected on the spot.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 12 December 2011 Resolved
Waste receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom. Found plastic waste receptacles being used for combustible waste throughout the ship. [2001 SOLAS II-2/18.5]
Action required: 705 - Other - as specified
Due 12 January 2012
Resolved 28 March 2012
Resolution: Received class survey report attesting to satisfactory correction of deficiency.
Engineering › Freshwater System (intermediary cooling) › Piping
Issued 3 December 2010 Resolved
Several pipes are wasted on fresh water Hydrophore System causing leakage on deck plating. Deck plating below Hydrophore unit is wated causing water to leak on the wire runs below. Fitting below the freeboard deck shall prevent water from passing inboard.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 3 December 2010
Resolved 13 January 2011
Resolution: Class Report was submitted clearing deficiency. All Satisfactory.
Lifesaving › Launching Appliances › Block
Issued 22 August 2006 Resolved
Repair Lifeboat #4 Aft lifeboat pulley is dry/noisy.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 August 2006
Resolved 24 August 2006
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 16 August 2005 Resolved
Ensure all decorative glass doors do not interfere with closing of any fire screeen door. An open glass door should not block fire screen door from closing. (Jadi Spa, Explorer Club & smoking room)
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 4 September 2005
Resolved 4 September 2005
Resolution: All glass doors opening arrangements modified so that doors do not interfere or obstruct the closing of the fire screen doors.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 16 August 2005 Resolved
-Remove locks as needed to ensure escape to Jadz Spa at all times. Escape / evacuation hazard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 September 2005
Resolved 4 September 2005
Resolution: Keys provided in break glass boxes adjacent to the doors so as to be used in case of emergency.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 16 August 2005 Resolved
Ensure all fire fighting uniforms are approved "fire entry" uniforms. Existing fire uniforms are fire "proximity" uniforms.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 4 September 2005
Resolved 4 September 2005
Resolution: Unifoms have been ordered purchase order number 1465 10267.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 16 August 2005 Resolved
Technical space in proximity to theater improperly being used as storage space.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 4 September 2005
Resolved 4 September 2005
Resolution: Technical space in proximity to theater being used as storage has been cleared of all items.
Engineering › Steering Gear System › Follow-up Assembly
Issued 31 January 2005 Resolved
ENSURE STEERING SYSTEMS ARE OPERATIONAL FROM ALL LOCATIONS. STEERING ONLY WORKING WITH EMERGENCY CONTROL.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 February 2005
Resolution: BLOWN STEERING GEAR CAPACITOR REPLACED. VESSEL CONDUCTED STEERING TESTS AT THE PIER AND THEN AGAIN DURING SEA TRIALS..
Communications › Radio Communications › VHF Radiotelephone
Issued 31 January 2005 Resolved
ENSURE ALL COMMUNICATION EQUIPMENT IS OPERATIONAL. ALL COMMUNNICATION EQUIPMENT WITH THE EXCEPTION OF HANDHELD RADIOS IS INOPERABLE.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 February 2005
Resolution: ALL COMMUNICATIONS EQUIPMENT REPAIRED OR REPLACED. VESSEL CONDUCTED TEST FOR GL AND USCG PIER SIDE.
Construction/Loadline › Hull › Hull Plating
Issued 31 January 2005 Resolved
ENSURE ALL STRUCTURAL DAMAGE IS REPAIRED. BOW PLATES ARE DENTED IN AND HULL PLATES ARE DENTED FROM FRAME 138-160. THERE IS ONE CRACKED FRAME IN THE ENGINE ROOM.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 February 2005
Resolution: TEMPORARY REPAIRS MADE AND APPROVED BY THE VESSELS CLASS SOCIETY. VESSEL WILL ENTER DRY DOCK IN MAY OR JUNE 2005 TO EFFECT PERMANENT REPAIRS.
Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 31 January 2005 Resolved
ENSURE ALL BRIDGE NAVIGATION EQUIPMENT IS OPERATIONAL. ALL BRIDGE NAVIGATION EQUIPMENT WITH THE EXCEPTION OF ONE GPS IS INOPERABLE.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 February 2005
Resolution: ALL ELECTRONICS ON THE BRIDGE HAVE BEEN REPAIRED OR REPLACED WITH TWO EXCEPTIONS - SEE SOLAS EXEMPTIONS. PROPER OPERATION PROVED DURING SEA TRIALS.
Engineering › Diesel Engine (propulsion-electric) › Governor
Issued 31 January 2005 Resolved
MAIN ENGINE #2 IS NOT OPERATIONAL. ALL OTHER ENGINES ARE OPERATIONAL IN EMERGENCY MODE ONLY. ENSURE ALL AMIN ENGINES ARE OPERATIONAL;
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 February 2005
Resolution: MAIN ENGINE CONTROLS EITHER REPAIRED OR REPLACED BY ABB. VESSEL CONDUCTED SEA TRAILS AND ALL MAIN ENGINES OPERATED NORMALLY.
System not recorded
Issued 12 April 2001 Resolved
COMPLETE WORKLIST ITEMS 6, 11, 12, 13, 14, 18, 33, 34, 35, 40, 43, 44, 47, 50, 51, 53, 55, 66, 69, 70, 75, 76, and 77 PRIOR TO ENTRY TO U.S. WATERS.
Condition: Unknown
Due 7 November 2001
Resolved 25 November 2002

Ownership record