← All vessels
AYALA
Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG Southwest District (CGD-SW) · Other hulls named AYALA
AYALA is a 1989 passenger vessel (inspected). The Coast Guard has recorded 67 inspections since 1989, most recently in April 2025, along with 85 deficiencies, 2 operational controls and 1 casualty investigation in 2013.
Records from 1989 to 2025. Most recent: inspection, 22 April 2025.
- Built
- 1989
- Last inspected
- 22 April 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 85 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2013
Identity
952653
WAH6014
335195
Flag
UNITED STATES
366932310
Maury page id
psix-335195
Inspections, by type
…with no type recorded3
Years with a record
36 calendar years (1989–2025)
The 67 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)48.0 ft × 15.3 ft × 6.2 ft
Registered tonnagegross 30 / net 24
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEAARK MARINE INC · MONTICELLO, AR, UNITED STATES · built 1989
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it30 - Simplified, Gross Ton
24 - Simplified, Net Ton
24 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WAH6014MMSI 366932310 · active · compulsorily equipped · granted 22 February 2024, expires 17 May 2034
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 67
22 April 2025
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8113625
13 August 2024
Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7979850
20 June 2024
Drydock Exam · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7939433
18 April 2023
Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7670202
1 June 2022
Internal Structural Exam · Deficiency Check · Hull Examination · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7464898
17 May 2021
Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7196414
16 September 2020
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7059573
26 August 2020
Deficiency Check · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7044406
22 July 2020
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7012856
10 September 2019
Annual Inspection · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6808956
20 June 2018
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6449216
29 May 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6422895
26 July 2017
Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6219594
13 June 2016
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5906096
31 May 2016
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5892460
23 October 2015
Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5748041
19 June 2014
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4893116
1 May 2012
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4299389
7 September 2011
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4132231
20 January 2011
Simplified Stability Test · Drydock Exam · Plan Review "T" Boat
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3930071
8 December 2010
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3902984
11 December 2009
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3645760
6 October 2008
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3339808
10 September 2008
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3309428
8 January 2008
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3127421
6 November 2007
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3094288
29 August 2006
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2763160
21 September 2005
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2498233
30 August 2005
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2468320
27 October 2004
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2257788
6 October 2004
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2197394
27 October 2003
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1936754
8 October 2003
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1913774
19 August 2003
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1880722
7 October 2002
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1686118
17 October 2001
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1362489
14 August 2001
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1472779
16 April 2001
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1066463
26 October 2000
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1373205
20 October 1999
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1430754
19 August 1999
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 781657
21 October 1998
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 802407
6 January 1998
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 780582
22 October 1997
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1118637
6 August 1997
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 785220
22 November 1996
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1181701
30 October 1996
Deficiency Check · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1357770
29 November 1995
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 883336
1 November 1995
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 880545
1 November 1995
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 885822
16 November 1994
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1179356
21 October 1994
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 865204
4 October 1994
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 866643
4 November 1993
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 842563
21 October 1993
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1461544
30 December 1992
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 839379
1 November 1992
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 937328
15 April 1992
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1259317
29 October 1991
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 937792
5 December 1990
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 931262
13 November 1990
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 922441
30 October 1990
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 928525
30 May 1990
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 918442
10 January 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1229759
7 December 1989
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 917120
1 December 1989
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 905315
1 November 1989
Initial Certification · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1002367
Deficiency record · 85
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 April 2025
Resolved
The materials and construction of fuel lines, including pipe, tube, and hose, must comply with the requirements of this paragraph. One feed and one return fuel line are damaged in the Engine Room.
46 CFR 182.455(a)(1)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 April 2025
Resolved
Flexible hose runs used in lube oil, fuel oil and fluid power systems, must be visible, easily accessible, protected from mechanical damage. Flexible hose in lazarette connecting to fuel tank is damaged.
46 CFR 182.720(e)
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 22 April 2025
Resolved
Ship station license present for operation of all maritime services transmitting equipment on board a vessel. FCC station authorization is expired.
47 CFR 80.13 (b)
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 22 April 2025
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. The battery for the portable light in the machinery space is dead.
46 CFR 183.430
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 April 2025
Resolved
The fuel shutoff valve at the tank must be manually operable from outside the compartment. Fuel shut off valve connection screw was stripped and not catching.
46 CFR 182.455 (b)(4)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 August 2024
Resolved
A power-driven fire pump shall be installed on each mechanically propelled "S" vessel which is a ferry vessel... Engine driven fire pump was leaking, repair to MI satisfaction.
46 CFR 181.10-1 (Old T)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 August 2024
Resolved
The intent of this part is to insure that the main propulsion machinery installed on each vessel is suitable...for the purpose intended. It is further indented that all machinery be installed and maintained in such a manner as to afford adequate protection against...personal injury. Machinery guard was missing on STBD engine fire pump, install to MI satisfaction.
46 CFR 182.01-5 (Old T)
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 13 August 2024
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels who: (1) Occupy a position, or perform the duties and functions of a position, required by the vessel's Certificate of Inspection. Vessel is missing proof of enrollment in random drug testing procedures, personnel, and testing facilities. Provide enrollment and mandatory testing information satisfactory to Marine Inspector.
46 CFR 16.230(a)
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 13 August 2024
Resolved
Except as noted in paragraph (c) of this section, stations in the maritime service must be licensed by the FCC either individually or by fleet. Vessel radio station authorization is expired, replace to MI satisfaction.
47 CFR 80.13(a)
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 13 August 2024
Resolved
Each launching appliance and each survival craft... must be in good working order and ready for immediate use before the vessel leaves port and at all time when the vessel is underway. Vessel IBA hydrostatic release was installed upside down, MI observed operator installing it correctly during inspection.
46 CFR 185.700(a)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 April 2023
Resolved
If garden hose is used, it shall be of a good commercial grade, constructed of an inner rubber tube, plies of braided cotton reinforcement and an outer rubber cover of equivalent material, and shall be fitted with a commercial garden hose nozzle of good grade bronze or equivalent metal. Nozzle displays excessive corrosion and is stuck in open position. Replace fire hose nozzle.
46 CFR 181.15-10 (e)
(OLD-T)
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 April 2023
Resolved
Except as otherwise provided in this section, machinery and fuel tank spaces shall be separated from accomodation spaces by watertight and/or vapor tight bulkheads. Engine Room FWD bulkhead has insufficient vapor tight boundary at STBD side bulkhead penetrations. Additionally, AFT Engine Room bulkhead on STBD side has penetrations that require closing. Fill all bulkhead penetrations to achieve sufficient vapor barrier to satisfaction of Marine Inspector.
46 CFR 182.35-1
(OLD-T)
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 18 April 2023
Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material, except in an accommodation space, radio room, galley, or similar space where it is not subject to damage. Light fixture in pilothouse on Port Side overhead is missing a proper cover, exposing flourescent bulbs. Install proper protective cover to satisfaction of Marine Inspector.
46 CFR 183.410 (a)
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 18 April 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to: (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Exposed wires in overhead exit in passenger cabin area. Remove wires, properly terminate, or install missing lighting device in area to satisfaction of Marine Inspector.
46 CFR 183.200 (b)
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 April 2023
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Burn gel and Ammonia Inhalants are expired and require replacement.
46 CFR 184.710
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 18 April 2023
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels who:
(1) Occupy a position, or perform the duties and functions of a position, required by the vessel's Certificate of Inspection. Vessel is missing proof of enrollment in random drug testing procedures, personnel, and testing facilities. Provide enrollment and mandatory testing information satisfactory to Marine Inspector.
46 CFR 16.230 (a)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 April 2023
Resolved
Remote fuel shutoff stations shall be marked in at least 1-inch letters indicating purpose of the valve and direction
of operation. Fuel shutoff markings on deck are faded and worn. Renew markings to satisfaction of Marine Inspector.
46 CFR 185.30-20
OLD "T"
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 April 2023
Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. 06 life jackets stowed in aft deck have worn/missing retroreflective tape. Replace tape to satisfaction of Marine Inspector.
46 CFR 185.604 (h)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 April 2023
Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. 02 Ring Life Buoys have worn/missing retroreflective tape. Replace to satisfaction of Marine Inspector.
46 CFR 185.604 (i)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 June 2022
Resolved
The fixed power bildge pump shall be self-priming and permenantely connceted to the bilge main. The fixed power bilge pump is inoperable.
46 CFR 185.25-10(b) [old "T"]
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 1 June 2022
Resolved
Each hatch exposed to the weather must be watertight. Hatch to engine room is not watertight.
46CFR 171.124(a)
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 1 June 2022
Resolved
Vessel must have an FCC station license with MMSI number. Crew could not provide FCC station license.
47 CFR 80.13
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 17 May 2021
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with 80.59 once every five years. Vessel's radiotelephony certificate expire in 2019. Must renew radiotelephony certificate. Vessel is restricted to no more than one thousand feet from shore.
47CFR80.903
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 September 2020
Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equiupment. Fire main was non operational due to a failure of the belt driven off the main engine.
46 CFR 176.810
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 September 2020
Resolved
ALL MACHINERY AND EQUIPMENT MUST BE INSTALLED AND MAINTAINED IN SUCH A MANNER AS TO AFFORD ADEQUATE PROTECTION FROM CAUSING FIRE, EXPLOSION, MACHINERY FAILURE, AND PERSONNEL INJURY. A FOUR INCH SECTION OF THE COMMON FIRE MAIN/BILGE PIPING WAS FOUND IN THE ENGINE ROOM TO BE WASTED RESULTING IN A CONTINUOUS LEAK INTO THE ENGINE ROOM'S BILGE WHEN THE SYSTEM WAS ENERGIZED.
46 CFR 182.100
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 September 2020
Resolved
SHUTOFF VALVES, INSTALLED SO AS TO CLOSE AGAINST THE FUEL FLOW, MUST BE FITTED IN THE FUEL SUPPLY LINES, ONE AT THE TANK CONNECTION AND ONE AT THE ENGINE END OF THE FUEL LINE TO STOP FUEL FLOW WHEN SERVICING ACCESSORIES. THE SHUTOFF VALVE AT THE TANK MUST BE MANUALLY OPERABLE FROM OUTSIDE THE COMPARTMENT IN WHICH THE VALVE IS LOCATED, PREFERABLY FROM AN ACCESSIBLE POSITION ON THE WEATHER DECK. FUEL TANK SHUTOFF VALVE SEPARATED DURING ACUATION DUE BEING LOOSELY FITTED IN PLACE. DEMONSTRATE PROPER OPERATION OF SHUTOFF VAVLE WITH PERMANENT INSTALLATION.
46 CFR 182.455(b)(4)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 26 August 2020
Resolved
During drydock examination, sea chests, sea valves, and sea strainers must be opened for examination. Two starboard valves associated with sink and sewage were unable to be inspected. Remove valves for inspection.
46 CFR 176.610
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 July 2020
Resolved
A vessel exposed to salt water more than three months in any 12 month period must undergo a drydock and internal structural examination at least once every two years. Vessel has failed to schedule drydock and internal structural examination within two years of last drydock as listed on its COI. 46 CFR 176.600(c)(1)
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 10 September 2019
Resolved
46 182.20-40 - Diesel fuel shutoff valves, installed so as to close against the fuel flow, shall be fitted in the fuel supply lines. The shutoff valve at the tank shall be operable from outside of the tank compartment. Fuel shutoff valve broken off of valve stem. Vessel must repair and operate the valve to the satisfaction of the attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 10 September 2019
Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces. Bulkhead penetration from engine room not vapor tight. Vessel must seal with appropriate material.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 10 September 2019
Resolved
46CFR 177.01-5 - The scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. Vessel sustained two broken windows within the pilothouse, affecting overall visibilty. Repair or replace all broken windows to the satisfaction of the attending Marine Inspector.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 10 September 2019
Resolved
The inspection and maintenance of the onboard life saving appliances shall be logged or otherwise documented for review by the Coast Guard upon request. The owner or managing operator shall make sure that maintenance is carried out in accordance with the manufacturer's instructions of all life saving appliances. Vessel does not have a log of maintenance and/or inspection of onboard life saving appliances.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 September 2019
Resolved
46CFR 177.01-5 - The scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. Multiple holes and pitting witnessed along the aft rails. Vessel must conduct repair or replace all defects within the rails prior to next credit dry dock.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 29 May 2018
Resolved
TWO WINDOWS WERE FOUND TO BE CRACKED. 46 CFR 177.1030
Construction/Loadline › Hull › Side Shell
Issued 26 July 2017
Resolved
Noted a fracture on the starboard quarter, approximately two feet above the waterline. Fracture was due to a sharp inset, which was about the size of a quarter.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 26 July 2017
Resolved
User fees overdue.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 26 July 2017
Resolved
Vessel unable to provide contract between consortium and State Parks.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 28 October 2015
Resolved
The 3 inch diameter bulkhead penetration just above the keel in bulkhead between engine room and 2nd compartment for electrical wires is open. Make this opening fire/water tight to satisfaction of attending marine inspector.
Fire Fighting › Remote Fuel Shutoff › General
Issued 28 October 2015
Resolved
While testing the remote fuel oil shutoff it was discovered that the remote reachrod attachment to valve handle located in Lazzerette has lost the attachment bolts and only partially works. Operator shall install reach rod properly and demonstrate prior to carrying passengers.
Communications › Alarms/Indicators › High Water Alarm
Issued 27 June 2014
Resolved
Properly repair and prove proper operation of high water alarm system. Manual inspection of spaces with high water alarm will be conducted and logged when carrying passengers while high water alarm is inoperable.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 7 September 2011
Resolved
Provide Coast Pilot and Light List on Vessel.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 September 2011
Resolved
Provide eye dressing and Iodine wipes in first aid kit.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 7 September 2011
Resolved
Provide emergency broadcast sticker at operation station.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 7 September 2011
Resolved
Renew floating water light battery for life ring.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 15 December 2010
Resolved
Provide 30x30 mesh screens for both diesel fuel tank vents IAW 46 CFR 182.20-35(d).
Engineering › Fuel Oil Service System › Valve
Issued 15 December 2010
Resolved
Properly label remote fuel shut-off valve on main deck, aft IAW 46 CFR 185.30-20.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 11 December 2009
Resolved
Provide a proof of Inland Navigation Rule book onboard
Lifesaving › Lifefloat › Pendant
Issued 10 September 2008
Resolved
Repair both life floats - (Becket lines on top life float and cut from painter on bottom life float.)
Personnel › Training › First Aid/CPR
Issued 7 November 2007
Resolved
Provide proof of first aide/CPR training
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 7 November 2007
Resolved
Provide a non slip surface at embarkation station.
Electrical › Electrical Distribution System (service) › Fuse
Issued 7 November 2007
Resolved
Provide in-line fuse protection to both engine room batteries in accordance with 46CFR 183.350(g).
Lifesaving › Lifefloat › Painter
Issued 20 September 2006
Resolved
Re-stow sea painter line for ease of float free operation.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 21 September 2005
Resolved
Properly display EAP phone number.
Documentation › Safety Management System › Safety/Environmental Protection Policy
Issued 6 October 2004
Resolved
Provide proof of current CPR Certificate.
Stability › Watertight Integrity › General
Issued 6 October 2004
Resolved
Make portside engine room hatch watertight in way of gasket.
Navigation › Piloting/Steering › Marine Charts
Issued 6 October 2004
Resolved
Provide corrected/up to date charts on board.
Electrical › Electric Supply System (service) › Cable
Issued 6 October 2004
Resolved
Tighten postive cable to electric starter on stbd MDE.
Stability › Watertight Integrity › General
Issued 6 October 2004
Resolved
Install securing device to both port and STBD engine room hatches IAW 46 CFR 178.35-1D
Accommodation/Occupational Safety › Medical/First Aid
Issued 8 October 2003
Resolved
Replace expired items in first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Navigation › Piloting/Steering
Issued 8 October 2003
Resolved
Provide excerpts to all required navigation publications, Coast Pilot [name withheld] and Notice to Mariners. LEGACY COMPONENT DESC: Coast Guard Light List
Lifesaving › Buoyant Apparatus
Issued 8 October 2003
Resolved
Place slats between life floats.
Engineering › Bilge Water Management System › Valve
Issued 8 October 2003
Resolved
Prove operation of bilge system.
Electrical › Lighting (service)
Issued 8 October 2003
Resolved
Clean lenses on navigational lights and prove operation.
Lifesaving
Issued 30 October 1996
Resolved
PROPERLY REPAIR CUTS IN LIFEFLOAT USING A MANUFACTURER'S APPROVED REPAIR KIT.
Lifesaving
Issued 30 October 1996
Resolved
REPLACE LINE ON WATERLIGHT FOR RINGBUOY, STBD SIDE.
Lifesaving
Issued 30 October 1996
Resolved
PROVIDE REFLECTIVE TAPE FOR BOTH RINGBUOYS ON AFT PART OF VSL. VSL LIMITEDTO DAYTIME OPERATIONS UNTIL COMPLETE.
Documentation
Issued 30 October 1996
Resolved
PROVIDE RECENT RESULTS FROM DRUG PROGRAM TESTING.
Lifesaving
Issued 21 October 1994
Resolved
REPLACE SIX ORANGE SMOKE FLARES (EXP. 12/94).
Engineering
Issued 21 October 1994
Resolved
PROVIDE GUARD FOR PORT ENGINE (PULLEY AT FRONT).
Lifesaving
Issued 21 October 1993
Resolved
SEPARATE ADULT & CHILD PFD's. THIS ITEM IS TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING CG INSPECTOR BY 04NOV93.
Documentation
Issued 1 November 1992
Resolved
PROVIDE PROOF OF APPROVED DRUG TESTING PROGRAM.
Engineering
Issued 5 December 1990
Resolved
GOUGE OUT AND RE-WELD AREA AROUND PIN HOLE IN INBOARD PORT KEEL COOLER OUTBOARD FWD CORNER.
Construction/Loadline
Issued 5 December 1990
Resolved
RELOCATE SALT WATER SUCTION VALVE (1") IN E/R TO AS CLOSE AS PRACTICAL TO THE THROUGH HULL.
Construction/Loadline
Issued 5 December 1990
Resolved
SUBMIT PROPOSAL TO MODIFY SEA VALVE THROUGH HULLS (4) TO ALLOW FOR SEA STRAINER REMOVAL TO MSO SAN FRANCISCO FOR APPROVAL, AND COMPLETE APPROVED MODIFICATIONS PRIOR TO LEAVING DRYDOCK.
Fire Fighting
Issued 30 October 1990
Resolved
FABRICATE AND INSTALL BELT GUARD IN WAY OF FIRE/BILGE PUMP ATTACHED TO STBDMAIN DIESEL ENGINE.
Navigation
Issued 30 October 1990
Resolved
DRILL AND INSTALL COTTER PINS IN STEERING GEAR LINKAGES IN LAZERETTE.
Navigation
Issued 30 October 1990
Resolved
PROVIDE COMPASS DEVIATION CARD FOR MAGNETIC COMPASS.
Lifesaving
Issued 30 October 1990
Resolved
VSL OPERATOR NEEDS TO PERMANENTLY AFFIX ONE ADDITIONAL RING LIFE BUOY TO THE 15 MAN LIFEFLOAT TO MEET PRIMARY LIFESAVING EQUIPMENT REQUIREMENTS FOR 32 PASSENGERS ON A LIMITED COASTAL ROUTE. (THIS WOULD LEAVE A TOTAL OF TWOLIFE RINGS ATTACHED TO THE LIFEFLOAT)
Engineering
Issued 1 December 1989
Resolved
7 INSTALL DEEL COOLER VALVES OR HARD PIPE ABOVE THE WATERLINE INTAKE AND RETURN LINES PER 46CFR56.50-96.
Engineering
Issued 1 December 1989
Resolved
1 REPAIR FUEL LEAK AT ENGINE (STARBOARD) AND PERFORM OPERATIONAL ENGINE TESTS.
Lifesaving
Issued 1 December 1989
Resolved
3 PROVIDE ONE ADDITIONAL CHILD PFD FOR A TOTAL OF 4.
Lifesaving
Issued 1 December 1989
Resolved
4 INCREASE BUOYANT APPARATUS TO A CAPACITY OF 16. THIS MAY BE ACCOMPLISHED BY THE ADDITION OF A RING BUOY FASTENED TO THE B/A.
Documentation
Issued 1 December 1989
Resolved
5 PROVIDE FCC CERTIFICATES, BOTH STATION LICENSE AND SAFETY RADIOTELEPHONY CERTIFICATES.
Documentation
Issued 1 December 1989
Resolved
6 PROVIDE DOCUMENTATION CERTIFICATE.
Fire Fighting
Issued 1 December 1989
Resolved
2 MOUNT ENGINE ROOM FIRE EXTINGUISHERS OUTSIDE OF ENGINE ROOM.
Casualty record · 1
22 August 2013Routine · role: Involved in a Marine Casualty · activity 4694232
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.