AYALA

AYALA is a 1989 passenger vessel (inspected). The Coast Guard has recorded 67 inspections since 1989, most recently in April 2025, along with 85 deficiencies, 2 operational controls and 1 casualty investigation in 2013.

Records from 1989 to 2025. Most recent: inspection, 22 April 2025.

Built
1989
Last inspected
22 April 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WAH6014
335195
Flag
UNITED STATES
366932310
Maury page id
psix-335195

Inspections, by type

…with no type recorded3
Years with a record 36 calendar years (1989–2025)
The 67 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)48.0 ft × 15.3 ft × 6.2 ft
Registered tonnagegross 30 / net 24
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEAARK MARINE INC · MONTICELLO, AR, UNITED STATES · built 1989
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it30 - Simplified, Gross Ton
24 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WAH6014MMSI 366932310 · active · compulsorily equipped · granted 22 February 2024, expires 17 May 2034
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 67

22 April 2025 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8113625
13 August 2024 Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7979850
20 June 2024 Drydock Exam · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7939433
18 April 2023 Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7670202
1 June 2022 Internal Structural Exam · Deficiency Check · Hull Examination · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7464898
17 May 2021 Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7196414
16 September 2020 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7059573
26 August 2020 Deficiency Check · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7044406
22 July 2020 Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7012856
10 September 2019 Annual Inspection · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6808956
20 June 2018 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6449216
29 May 2018 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6422895
26 July 2017 Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6219594
13 June 2016 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5906096
31 May 2016 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5892460
23 October 2015 Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5748041
19 June 2014 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4893116
1 May 2012 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4299389
7 September 2011 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4132231
20 January 2011 Simplified Stability Test · Drydock Exam · Plan Review "T" Boat
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3930071
8 December 2010 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3902984
11 December 2009 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3645760
6 October 2008 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3339808
10 September 2008 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3309428
8 January 2008 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3127421
6 November 2007 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3094288
29 August 2006 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2763160
21 September 2005 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2498233
30 August 2005 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2468320
27 October 2004 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2257788
6 October 2004 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2197394
27 October 2003 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1936754
8 October 2003 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1913774
19 August 2003 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1880722
7 October 2002 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1686118
17 October 2001 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1362489
14 August 2001 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1472779
16 April 2001 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1066463
26 October 2000 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1373205
20 October 1999 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1430754
19 August 1999 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 781657
21 October 1998 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 802407
6 January 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 780582
22 October 1997 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1118637
6 August 1997 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 785220
22 November 1996 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1181701
30 October 1996 Deficiency Check · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1357770
29 November 1995 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 883336
1 November 1995 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 880545
1 November 1995 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 885822
16 November 1994 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1179356
21 October 1994 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 865204
4 October 1994 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 866643
4 November 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 842563
21 October 1993 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1461544
30 December 1992 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 839379
1 November 1992 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 937328
15 April 1992 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1259317
29 October 1991 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 937792
5 December 1990 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 931262
13 November 1990 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 922441
30 October 1990 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 928525
30 May 1990 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 918442
10 January 1990 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1229759
7 December 1989 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 917120
1 December 1989 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 905315
1 November 1989 Initial Certification · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1002367

Deficiency record · 85

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 April 2025 Resolved
The materials and construction of fuel lines, including pipe, tube, and hose, must comply with the requirements of this paragraph. One feed and one return fuel line are damaged in the Engine Room. 46 CFR 182.455(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2025
Resolved 20 May 2025
Resolution: Replaced fuel lines
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 April 2025 Resolved
Flexible hose runs used in lube oil, fuel oil and fluid power systems, must be visible, easily accessible, protected from mechanical damage. Flexible hose in lazarette connecting to fuel tank is damaged. 46 CFR 182.720(e)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2025
Resolved 20 May 2025
Resolution: Replaced fuel lines
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 22 April 2025 Resolved
Ship station license present for operation of all maritime services transmitting equipment on board a vessel. FCC station authorization is expired. 47 CFR 80.13 (b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2025
Resolved 5 May 2025
Resolution: Renewed FCC station authorization, photo in documents tab.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 22 April 2025 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. The battery for the portable light in the machinery space is dead. 46 CFR 183.430
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2025
Resolved 5 May 2025
Resolution: Provided photos of new portable light, see in documents tab.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 April 2025 Resolved
The fuel shutoff valve at the tank must be manually operable from outside the compartment. Fuel shut off valve connection screw was stripped and not catching. 46 CFR 182.455 (b)(4)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 22 April 2025
Resolved 22 April 2025
Resolution: Crew repaired the valve connection and properly actuated the valve.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 August 2024 Resolved
A power-driven fire pump shall be installed on each mechanically propelled "S" vessel which is a ferry vessel... Engine driven fire pump was leaking, repair to MI satisfaction. 46 CFR 181.10-1 (Old T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 October 2024
Resolution: Operator installed in-kind pump and conducted SAT operational test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 August 2024 Resolved
The intent of this part is to insure that the main propulsion machinery installed on each vessel is suitable...for the purpose intended. It is further indented that all machinery be installed and maintained in such a manner as to afford adequate protection against...personal injury. Machinery guard was missing on STBD engine fire pump, install to MI satisfaction. 46 CFR 182.01-5 (Old T)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 November 2024
Resolution: Operator installed new machinery guard to MI satisfaction.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 13 August 2024 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels who: (1) Occupy a position, or perform the duties and functions of a position, required by the vessel's Certificate of Inspection. Vessel is missing proof of enrollment in random drug testing procedures, personnel, and testing facilities. Provide enrollment and mandatory testing information satisfactory to Marine Inspector. 46 CFR 16.230(a)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 August 2024
Resolution: Operator submitted documentation of enrollment in State of California drug testing program for state parks employment.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 13 August 2024 Resolved
Except as noted in paragraph (c) of this section, stations in the maritime service must be licensed by the FCC either individually or by fleet. Vessel radio station authorization is expired, replace to MI satisfaction. 47 CFR 80.13(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 August 2024
Resolution: Valid radio station authorization recieved by operator with same call sign.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 13 August 2024 Resolved
Each launching appliance and each survival craft... must be in good working order and ready for immediate use before the vessel leaves port and at all time when the vessel is underway. Vessel IBA hydrostatic release was installed upside down, MI observed operator installing it correctly during inspection. 46 CFR 185.700(a)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 August 2024
Resolution: MI observed operator install hydrostatic release for IBA properly.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 April 2023 Resolved
If garden hose is used, it shall be of a good commercial grade, constructed of an inner rubber tube, plies of braided cotton reinforcement and an outer rubber cover of equivalent material, and shall be fitted with a commercial garden hose nozzle of good grade bronze or equivalent metal. Nozzle displays excessive corrosion and is stuck in open position. Replace fire hose nozzle. 46 CFR 181.15-10 (e) (OLD-T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2023
Resolved 2 May 2023
Resolution: Replaced with appropriate nozzle.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 April 2023 Resolved
Except as otherwise provided in this section, machinery and fuel tank spaces shall be separated from accomodation spaces by watertight and/or vapor tight bulkheads. Engine Room FWD bulkhead has insufficient vapor tight boundary at STBD side bulkhead penetrations. Additionally, AFT Engine Room bulkhead on STBD side has penetrations that require closing. Fill all bulkhead penetrations to achieve sufficient vapor barrier to satisfaction of Marine Inspector. 46 CFR 182.35-1 (OLD-T)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2023
Resolved 17 May 2023
Resolution: Satisfactorily made vapor tight.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 18 April 2023 Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material, except in an accommodation space, radio room, galley, or similar space where it is not subject to damage. Light fixture in pilothouse on Port Side overhead is missing a proper cover, exposing flourescent bulbs. Install proper protective cover to satisfaction of Marine Inspector. 46 CFR 183.410 (a)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2023
Resolved 17 May 2023
Resolution: Light properly covered.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 18 April 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to: (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Exposed wires in overhead exit in passenger cabin area. Remove wires, properly terminate, or install missing lighting device in area to satisfaction of Marine Inspector. 46 CFR 183.200 (b)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2023
Resolved 17 May 2023
Resolution: Wires removed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 April 2023 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Burn gel and Ammonia Inhalants are expired and require replacement. 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2023
Resolved 2 May 2023
Resolution: Replaced with valid contents.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 18 April 2023 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels who: (1) Occupy a position, or perform the duties and functions of a position, required by the vessel's Certificate of Inspection. Vessel is missing proof of enrollment in random drug testing procedures, personnel, and testing facilities. Provide enrollment and mandatory testing information satisfactory to Marine Inspector. 46 CFR 16.230 (a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2023
Resolved 4 May 2023
Resolution: Provided satisfactory evidence of enrollment in chemical testing program for all employees.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 April 2023 Resolved
Remote fuel shutoff stations shall be marked in at least 1-inch letters indicating purpose of the valve and direction of operation. Fuel shutoff markings on deck are faded and worn. Renew markings to satisfaction of Marine Inspector. 46 CFR 185.30-20 OLD "T"
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2023
Resolved 2 May 2023
Resolution: Proper markings renewed satisfactorily.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 April 2023 Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. 06 life jackets stowed in aft deck have worn/missing retroreflective tape. Replace tape to satisfaction of Marine Inspector. 46 CFR 185.604 (h)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2023
Resolved 17 May 2023
Resolution: Retroreflective tape properly replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 April 2023 Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. 02 Ring Life Buoys have worn/missing retroreflective tape. Replace to satisfaction of Marine Inspector. 46 CFR 185.604 (i)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2023
Resolved 17 May 2023
Resolution: Retroflective tape properly applied.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 June 2022 Resolved
The fixed power bildge pump shall be self-priming and permenantely connceted to the bilge main. The fixed power bilge pump is inoperable. 46 CFR 185.25-10(b) [old "T"]
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 June 2022
Resolution: Operator emailed video of proper operation.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 1 June 2022 Resolved
Each hatch exposed to the weather must be watertight. Hatch to engine room is not watertight. 46CFR 171.124(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 June 2022
Resolution: Operator replaced all gaskets.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 1 June 2022 Resolved
Vessel must have an FCC station license with MMSI number. Crew could not provide FCC station license. 47 CFR 80.13
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 June 2022
Resolution: FCC license posted.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 17 May 2021 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with 80.59 once every five years. Vessel's radiotelephony certificate expire in 2019. Must renew radiotelephony certificate. Vessel is restricted to no more than one thousand feet from shore. 47CFR80.903
Action required: 705 - Other - as specified
Resolved 29 May 2021
Resolution: Operator had a FCC-licensed technician renew the radiotelephony certificate.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 September 2020 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equiupment. Fire main was non operational due to a failure of the belt driven off the main engine. 46 CFR 176.810
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 September 2020
Resolved 2 October 2020
Resolution: Rep provided video of newly installed belt and operational test of fire pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 September 2020 Resolved
ALL MACHINERY AND EQUIPMENT MUST BE INSTALLED AND MAINTAINED IN SUCH A MANNER AS TO AFFORD ADEQUATE PROTECTION FROM CAUSING FIRE, EXPLOSION, MACHINERY FAILURE, AND PERSONNEL INJURY. A FOUR INCH SECTION OF THE COMMON FIRE MAIN/BILGE PIPING WAS FOUND IN THE ENGINE ROOM TO BE WASTED RESULTING IN A CONTINUOUS LEAK INTO THE ENGINE ROOM'S BILGE WHEN THE SYSTEM WAS ENERGIZED. 46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2020
Resolution: Wasted pipe reapired and line operationally tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 September 2020 Resolved
SHUTOFF VALVES, INSTALLED SO AS TO CLOSE AGAINST THE FUEL FLOW, MUST BE FITTED IN THE FUEL SUPPLY LINES, ONE AT THE TANK CONNECTION AND ONE AT THE ENGINE END OF THE FUEL LINE TO STOP FUEL FLOW WHEN SERVICING ACCESSORIES. THE SHUTOFF VALVE AT THE TANK MUST BE MANUALLY OPERABLE FROM OUTSIDE THE COMPARTMENT IN WHICH THE VALVE IS LOCATED, PREFERABLY FROM AN ACCESSIBLE POSITION ON THE WEATHER DECK. FUEL TANK SHUTOFF VALVE SEPARATED DURING ACUATION DUE BEING LOOSELY FITTED IN PLACE. DEMONSTRATE PROPER OPERATION OF SHUTOFF VAVLE WITH PERMANENT INSTALLATION. 46 CFR 182.455(b)(4)
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2020
Resolution: Witnessed satisfactory operation and permanent installation of fuel shutoff valve.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 26 August 2020 Resolved
During drydock examination, sea chests, sea valves, and sea strainers must be opened for examination. Two starboard valves associated with sink and sewage were unable to be inspected. Remove valves for inspection. 46 CFR 176.610
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2020
Resolved 28 September 2020
Resolution: Internal plumbing removed from both overboards and thru hulls were capped.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 July 2020 Resolved
A vessel exposed to salt water more than three months in any 12 month period must undergo a drydock and internal structural examination at least once every two years. Vessel has failed to schedule drydock and internal structural examination within two years of last drydock as listed on its COI. 46 CFR 176.600(c)(1)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 21 August 2020
Resolved 26 August 2020
Resolution: Vessel completed drydock inspection.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 10 September 2019 Resolved
46 182.20-40 - Diesel fuel shutoff valves, installed so as to close against the fuel flow, shall be fitted in the fuel supply lines. The shutoff valve at the tank shall be operable from outside of the tank compartment. Fuel shutoff valve broken off of valve stem. Vessel must repair and operate the valve to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 September 2019
Resolved 13 September 2019
Resolution: Operator submitted photo of fuel shutoff valve properly connected to valve stem and turn rod.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 10 September 2019 Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces. Bulkhead penetration from engine room not vapor tight. Vessel must seal with appropriate material.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2019
Resolved 2 October 2019
Resolution: Operator submitted photos of proper seal of bulkhead penetration using fireblock orange insulating foam sealant.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 10 September 2019 Resolved
46CFR 177.01-5 - The scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. Vessel sustained two broken windows within the pilothouse, affecting overall visibilty. Repair or replace all broken windows to the satisfaction of the attending Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2019
Resolved 18 November 2019
Resolution: Vessel operator submitted multiple photos showing new glass installation.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 10 September 2019 Resolved
The inspection and maintenance of the onboard life saving appliances shall be logged or otherwise documented for review by the Coast Guard upon request. The owner or managing operator shall make sure that maintenance is carried out in accordance with the manufacturer's instructions of all life saving appliances. Vessel does not have a log of maintenance and/or inspection of onboard life saving appliances.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2019
Resolved 18 November 2019
Resolution: Operator created a life saving and safety equipment log and sent Sector SF photos of it being used.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 September 2019 Resolved
46CFR 177.01-5 - The scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. Multiple holes and pitting witnessed along the aft rails. Vessel must conduct repair or replace all defects within the rails prior to next credit dry dock.
Action required: 705 - Other - as specified
Due 31 December 2019
Resolved 26 August 2020
Resolution: Rails inspected and found in suitable condition without repair required.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 29 May 2018 Resolved
TWO WINDOWS WERE FOUND TO BE CRACKED. 46 CFR 177.1030
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2018
Resolved 12 September 2019
Resolution: Redocumented in activity 6808956, to be corrected NLT 10OCT2019
Construction/Loadline › Hull › Side Shell
Issued 26 July 2017 Resolved
Noted a fracture on the starboard quarter, approximately two feet above the waterline. Fracture was due to a sharp inset, which was about the size of a quarter.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 August 2017
Resolved 4 August 2017
Resolution: Repairs completed to damaged area.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 26 July 2017 Resolved
User fees overdue.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 August 2017
Resolved 17 August 2017
Resolution: Verified user fees were no longer outstanding.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 26 July 2017 Resolved
Vessel unable to provide contract between consortium and State Parks.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 August 2017
Resolved 17 August 2017
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 28 October 2015 Resolved
The 3 inch diameter bulkhead penetration just above the keel in bulkhead between engine room and 2nd compartment for electrical wires is open. Make this opening fire/water tight to satisfaction of attending marine inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2015
Resolved 13 June 2016
Fire Fighting › Remote Fuel Shutoff › General
Issued 28 October 2015 Resolved
While testing the remote fuel oil shutoff it was discovered that the remote reachrod attachment to valve handle located in Lazzerette has lost the attachment bolts and only partially works. Operator shall install reach rod properly and demonstrate prior to carrying passengers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 October 2015
Resolved 28 October 2015
Resolution: corrected on the spot and demonstrated proper operation
Communications › Alarms/Indicators › High Water Alarm
Issued 27 June 2014 Resolved
Properly repair and prove proper operation of high water alarm system. Manual inspection of spaces with high water alarm will be conducted and logged when carrying passengers while high water alarm is inoperable.
Action required: 705 - Other - as specified
Due 4 July 2014
Resolved 13 June 2016
Navigation › Piloting/Steering › Coast Guard Light List
Issued 7 September 2011 Resolved
Provide Coast Pilot and Light List on Vessel.
Condition: Improper/Lack of Maintenance
Due 30 September 2011
Resolved 4 October 2011
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 September 2011 Resolved
Provide eye dressing and Iodine wipes in first aid kit.
Condition: Improper/Lack of Maintenance
Due 30 September 2011
Resolved 4 October 2011
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 7 September 2011 Resolved
Provide emergency broadcast sticker at operation station.
Condition: Improper/Lack of Maintenance
Due 30 September 2011
Resolved 4 October 2011
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 7 September 2011 Resolved
Renew floating water light battery for life ring.
Condition: Improper/Lack of Maintenance
Due 30 September 2011
Resolved 4 October 2011
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 15 December 2010 Resolved
Provide 30x30 mesh screens for both diesel fuel tank vents IAW 46 CFR 182.20-35(d).
Action required: 705 - Other - as specified
Due 3 January 2011
Resolved 21 January 2011
Resolution: Provided 30x30 mesh screens for fuel tanks.
Engineering › Fuel Oil Service System › Valve
Issued 15 December 2010 Resolved
Properly label remote fuel shut-off valve on main deck, aft IAW 46 CFR 185.30-20.
Action required: 705 - Other - as specified
Due 3 January 2011
Resolved 21 January 2011
Resolution: Properly labeled fuel shut-off valves.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 11 December 2009 Resolved
Provide a proof of Inland Navigation Rule book onboard
Condition: Unknown
Due 11 January 2010
Resolved 15 December 2009
Lifesaving › Lifefloat › Pendant
Issued 10 September 2008 Resolved
Repair both life floats - (Becket lines on top life float and cut from painter on bottom life float.)
Action required: 705 - Other - as specified
Due 10 November 2008
Resolved 11 November 2008
Resolution: Allyn Shafer sent pictures of the new life float and we were in the area and saw it in person. Looks good.
Personnel › Training › First Aid/CPR
Issued 7 November 2007 Resolved
Provide proof of first aide/CPR training
Action required: 705 - Other - as specified
Due 7 January 2008
Resolved 8 January 2008
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 7 November 2007 Resolved
Provide a non slip surface at embarkation station.
Action required: 705 - Other - as specified
Due 7 January 2008
Resolved 8 January 2008
Electrical › Electrical Distribution System (service) › Fuse
Issued 7 November 2007 Resolved
Provide in-line fuse protection to both engine room batteries in accordance with 46CFR 183.350(g).
Action required: 705 - Other - as specified
Due 7 January 2008
Resolved 8 January 2008
Lifesaving › Lifefloat › Painter
Issued 20 September 2006 Resolved
Re-stow sea painter line for ease of float free operation.
Condition: Improper Installation
Due 20 September 2006
Resolved 20 September 2006
Resolution: Corrected on the spot.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 21 September 2005 Resolved
Properly display EAP phone number.
Due 21 September 2005
Resolved 21 September 2005
Documentation › Safety Management System › Safety/Environmental Protection Policy
Issued 6 October 2004 Resolved
Provide proof of current CPR Certificate.
Action required: 705 - Other - as specified
Due 7 November 2004
Resolved 6 December 2004
Stability › Watertight Integrity › General
Issued 6 October 2004 Resolved
Make portside engine room hatch watertight in way of gasket.
Action required: 705 - Other - as specified
Due 7 November 2004
Resolved 27 October 2004
Navigation › Piloting/Steering › Marine Charts
Issued 6 October 2004 Resolved
Provide corrected/up to date charts on board.
Action required: 705 - Other - as specified
Due 7 November 2004
Resolved 27 October 2004
Electrical › Electric Supply System (service) › Cable
Issued 6 October 2004 Resolved
Tighten postive cable to electric starter on stbd MDE.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 October 2004
Resolved 6 October 2004
Resolution: Tightened connector
Stability › Watertight Integrity › General
Issued 6 October 2004 Resolved
Install securing device to both port and STBD engine room hatches IAW 46 CFR 178.35-1D
Action required: 705 - Other - as specified
Due 7 November 2004
Resolved 27 October 2004
Accommodation/Occupational Safety › Medical/First Aid
Issued 8 October 2003 Resolved
Replace expired items in first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Action required: 705 - Other - as specified
Due 8 November 2003
Resolved 27 October 2003
Navigation › Piloting/Steering
Issued 8 October 2003 Resolved
Provide excerpts to all required navigation publications, Coast Pilot [name withheld] and Notice to Mariners. LEGACY COMPONENT DESC: Coast Guard Light List
Action required: 705 - Other - as specified
Due 8 November 2003
Resolved 27 October 2003
Lifesaving › Buoyant Apparatus
Issued 8 October 2003 Resolved
Place slats between life floats.
Due 8 October 2003
Resolved 8 October 2003
Engineering › Bilge Water Management System › Valve
Issued 8 October 2003 Resolved
Prove operation of bilge system.
Due 8 October 2003
Resolved 8 October 2003
Resolution: Check valves in lazarette and engine room disassembled and repaired.
Electrical › Lighting (service)
Issued 8 October 2003 Resolved
Clean lenses on navigational lights and prove operation.
Due 8 October 2003
Resolved 8 October 2003
Lifesaving
Issued 30 October 1996 Resolved
PROPERLY REPAIR CUTS IN LIFEFLOAT USING A MANUFACTURER'S APPROVED REPAIR KIT.
Condition: Unknown
Due 30 October 1996
Resolved 30 October 1996
Lifesaving
Issued 30 October 1996 Resolved
REPLACE LINE ON WATERLIGHT FOR RINGBUOY, STBD SIDE.
Condition: Unknown
Due 30 November 1996
Resolved 1 November 1996
Lifesaving
Issued 30 October 1996 Resolved
PROVIDE REFLECTIVE TAPE FOR BOTH RINGBUOYS ON AFT PART OF VSL. VSL LIMITEDTO DAYTIME OPERATIONS UNTIL COMPLETE.
Condition: Unknown
Due 30 November 1996
Resolved 1 November 1996
Documentation
Issued 30 October 1996 Resolved
PROVIDE RECENT RESULTS FROM DRUG PROGRAM TESTING.
Condition: Unknown
Due 30 October 1996
Resolved 30 October 1996
Lifesaving
Issued 21 October 1994 Resolved
REPLACE SIX ORANGE SMOKE FLARES (EXP. 12/94).
Condition: Unknown
Due 21 October 1994
Resolved 21 October 1994
Engineering
Issued 21 October 1994 Resolved
PROVIDE GUARD FOR PORT ENGINE (PULLEY AT FRONT).
Condition: Unknown
Due 21 October 1994
Resolved 21 October 1994
Lifesaving
Issued 21 October 1993 Resolved
SEPARATE ADULT & CHILD PFD's. THIS ITEM IS TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING CG INSPECTOR BY 04NOV93.
Condition: Unknown
Due 21 October 1993
Resolved 21 October 1993
Documentation
Issued 1 November 1992 Resolved
PROVIDE PROOF OF APPROVED DRUG TESTING PROGRAM.
Condition: Unknown
Due 2 December 1992
Resolved 3 November 1992
Engineering
Issued 5 December 1990 Resolved
GOUGE OUT AND RE-WELD AREA AROUND PIN HOLE IN INBOARD PORT KEEL COOLER OUTBOARD FWD CORNER.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Construction/Loadline
Issued 5 December 1990 Resolved
RELOCATE SALT WATER SUCTION VALVE (1") IN E/R TO AS CLOSE AS PRACTICAL TO THE THROUGH HULL.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Construction/Loadline
Issued 5 December 1990 Resolved
SUBMIT PROPOSAL TO MODIFY SEA VALVE THROUGH HULLS (4) TO ALLOW FOR SEA STRAINER REMOVAL TO MSO SAN FRANCISCO FOR APPROVAL, AND COMPLETE APPROVED MODIFICATIONS PRIOR TO LEAVING DRYDOCK.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Fire Fighting
Issued 30 October 1990 Resolved
FABRICATE AND INSTALL BELT GUARD IN WAY OF FIRE/BILGE PUMP ATTACHED TO STBDMAIN DIESEL ENGINE.
Condition: Unknown
Due 30 October 1990
Resolved 30 October 1990
Navigation
Issued 30 October 1990 Resolved
DRILL AND INSTALL COTTER PINS IN STEERING GEAR LINKAGES IN LAZERETTE.
Condition: Unknown
Due 30 October 1990
Resolved 30 October 1990
Navigation
Issued 30 October 1990 Resolved
PROVIDE COMPASS DEVIATION CARD FOR MAGNETIC COMPASS.
Condition: Unknown
Due 30 October 1990
Resolved 30 October 1990
Lifesaving
Issued 30 October 1990 Resolved
VSL OPERATOR NEEDS TO PERMANENTLY AFFIX ONE ADDITIONAL RING LIFE BUOY TO THE 15 MAN LIFEFLOAT TO MEET PRIMARY LIFESAVING EQUIPMENT REQUIREMENTS FOR 32 PASSENGERS ON A LIMITED COASTAL ROUTE. (THIS WOULD LEAVE A TOTAL OF TWOLIFE RINGS ATTACHED TO THE LIFEFLOAT)
Condition: Unknown
Due 30 October 1990
Resolved 30 October 1990
Engineering
Issued 1 December 1989 Resolved
7 INSTALL DEEL COOLER VALVES OR HARD PIPE ABOVE THE WATERLINE INTAKE AND RETURN LINES PER 46CFR56.50-96.
Condition: Unknown
Due 1 December 1989
Resolved 1 December 1989
Engineering
Issued 1 December 1989 Resolved
1 REPAIR FUEL LEAK AT ENGINE (STARBOARD) AND PERFORM OPERATIONAL ENGINE TESTS.
Condition: Unknown
Due 1 December 1989
Resolved 1 December 1989
Lifesaving
Issued 1 December 1989 Resolved
3 PROVIDE ONE ADDITIONAL CHILD PFD FOR A TOTAL OF 4.
Condition: Unknown
Due 1 December 1989
Resolved 1 December 1989
Lifesaving
Issued 1 December 1989 Resolved
4 INCREASE BUOYANT APPARATUS TO A CAPACITY OF 16. THIS MAY BE ACCOMPLISHED BY THE ADDITION OF A RING BUOY FASTENED TO THE B/A.
Condition: Unknown
Due 1 December 1989
Resolved 1 December 1989
Documentation
Issued 1 December 1989 Resolved
5 PROVIDE FCC CERTIFICATES, BOTH STATION LICENSE AND SAFETY RADIOTELEPHONY CERTIFICATES.
Condition: Unknown
Due 1 December 1989
Resolved 1 December 1989
Documentation
Issued 1 December 1989 Resolved
6 PROVIDE DOCUMENTATION CERTIFICATE.
Condition: Unknown
Due 1 December 1989
Resolved 1 December 1989
Fire Fighting
Issued 1 December 1989 Resolved
2 MOUNT ENGINE ROOM FIRE EXTINGUISHERS OUTSIDE OF ENGINE ROOM.
Condition: Unknown
Due 1 December 1989
Resolved 1 December 1989

Casualty record · 1

22 August 2013Routine · role: Involved in a Marine Casualty · activity 4694232
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.