Records from 2004 to 2026. Most recent: inspection, 12 April 2026.
Inspection history · 41
12 April 2026
Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 8346482
31 March 2026
Administrative Inspection · Vessel Attendance · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8313388
13 January 2026
Internal Structural Exam · Drydock Exam · Vessel Attendance
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8306217
8 July 2025
Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8178784
4 April 2025
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8104845
20 April 2024
Administrative Inspection · In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7900365
15 April 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7896852
28 March 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7884781
18 March 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7882073
16 June 2023
Damage Survey · Administrative Inspection · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7716241
6 June 2023
Damage Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7704186
5 June 2023
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8078361
21 March 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7654573
13 December 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7608725
29 September 2022
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7568767
11 April 2022
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7415966
14 March 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7445441
27 January 2022
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7386912
14 April 2021
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7173972
13 August 2020
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7084637
27 January 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6914923
4 October 2019
In-Service Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6827382
19 September 2019
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6815745
11 September 2019
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6809125
23 July 2019
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6760110
23 May 2019
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6699653
2 April 2019
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6654581
26 November 2018
Inclining Experiment · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6585067
12 November 2018
Examination of Repairs · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6586763
12 September 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6538756
15 August 2018
Damage Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6513295
21 March 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6376323
5 February 2018
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6351176
11 September 2017
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6265083
19 April 2017
Deadweight Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6142962
22 March 2017
Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6109938
7 February 2017
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6084097
13 June 2016
Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5906582
28 May 2016
In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5892631
15 March 2016
DAPI Audit · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5831493
19 January 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5799897
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 6 April 2026
Resolved
Each abandon ship drill must include: Summoning passengers on a vessel on an overnight voyage to areas of refuge or embarkation stations and ensuring that they are made aware of hose the order to abandon ship will be given. Vessel did not have crew onboard to manage passenger evacuation and muster at time of inspection. Vessel to complete abandon ship drill with simulated passengers with marine inspectors prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 April 2026
Resolved 12 April 2026
Resolution: MSD Ketchikan witnessed satisfactory abandon ship drill.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 April 2026
Resolved
At each inspection for certification, the vessel must be fully prepared for inspection and testing of fire protection equipment, including fire-confining appliances such as doors.
Vessel’s SFP was originally built to NVIC 11-83 / Subchapter H per MSC letter H2-1-610 of 15 July 1991, with subsequent SFP modifications reviewed to Subchapter K standards by MSC letter H2-0101204 of 25 April 2001. Both H [72.05-25 (b)(9)] and K [116.435(c)(6)] require doors in stairtowers and stairways to be self-closing. The fire door to STBD mid crew and the fire door to the forward crew berthing were incapable of closing and latching under their own power.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2026
Resolved 27 April 2026
Resolution: Crew fixed both doors and are capable of latching under their own power.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 6 April 2026
Resolved
When it is determined by the Commandant that the gross register tonnage for a particular passenger vessel, which is attained by exemptions, reductions, or other devices in the basic gross tonnage formulation, will circumvent or be incompatible with the application of specific safety requirements in the passenger vessel regulations for a vessel of such physical size, the Commandant shall prescribe the regulations to be made applicable to such vessel. Vessel has an existing fire control plan that does not show the fire dampers used for fire containment and extinguishing on the vessel. Vessel is to update the fire control plan to reflect the location of all fire damper onboard.
46 CFR 175.05-15(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2026
Resolved 11 May 2026
Resolution: Crew has worked with Elliot Bay Design Group to update fire control plan.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 6 April 2026
Resolved
To enhance protection of life and property it is mandatory that each 406.0-406.1 MHz EPIRB be registered with NOAA before installation and that information be kept up-to-date. Vessel had FCC registration for an EPIRB unable to be located on the vessel.
47 CFR 80.1061(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2026
Resolved 5 May 2026
Resolution: Safety officer provided proof from NOAA that EPIRB has been designated as lost.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 April 2026
No resolution recorded
Provision shall be made by means of plugs, covers, etc., to prevent the admission of air in the space protected. Vessel has a CO2 protected locker to store flammable materials that is rusted to the point of the locker being open to the environment, therefore compromising the boundary of the protected space.
46 CFR 181.20-35 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2026 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 6 April 2026
Resolved
At each inspection for certification, the vessel must be fully prepared for inspection and testing of fire protection equipment, including fire-confining appliances such as fire dampers.
Vessel’s SFP was originally built to NVIC 11-83 / Subchapter H per MSC letter H2-1-610 of 15 July 1991, with subsequent SFP modifications reviewed to Subchapter K standards by MSC letter H2-0101204 of 25 April 2001. Both H [72.05-50 (i)] and K [116.610(d)] require a ventilation duct to have a suitable means of manual operation or other suitable means must be provided in an accessible location outside the space served. Galley damper on STBD main deck of vessel is inaccessible from within the vessel and requires crew to climb the side of the vessel to fully close. Vessel is to install a suitable means of safely closing the damper from within the vessel outside the space the damper serves.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2026
Resolved 12 May 2026
Resolution: Crew installed means to close the fire damper while onboard the vessel.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 6 April 2026
Resolved
Each space accessible to passengers or used by the crew on a regular basis must have at least two means of escape.
Starboard side door leading out from the category 9 electrical room underneath the wheelhouse is seized and cannot be opened from the inside or outside.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2026
Resolved 23 April 2026
Resolution: Crew fixed door from STBD Bridge void space is capable of opening and closing.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 6 April 2026
No resolution recorded
At each inspection for certification, the vessel must be fully prepared for inspection and testing of fire protection equipment, including fire-confining appliances such as fire dampers.
Vessel’s SFP was originally built to NVIC 11-83 / Subchapter H per MSC letter H2-1-610 of 15 July 1991, with subsequent SFP modifications reviewed to Subchapter K standards by MSC letter H2-0101204 of 25 April 2001. Both H [72.05-50 (i)] and K [116.610(d)] require a ventilation duct to have a suitable means of manual operation or other suitable means must be provided in an accessible location outside the space served. Vent duct to exterior for the battery management room on 2nd deck forward, starboard side, has no means to close off the ventilation duct from the outside. Fire Control Plan rev D dated 3/17/26 shows battery management room to be surrounded by A-class bulkheads. Provide a proposal to the OCMI within 30 days for how to bring the onboard installation into full regulatory compliance no later than 12/31/26.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2026 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 April 2024
Resolved
Vessels described by 46 CFR 114.110(e) must have an interconnected fire detection system in compliance with 46 CFR 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces.
Temporary installation includes interconnected system with additional audible alarms in each accommodation space. Extended requirement for permanent installation to 30 NOVEMBER 2024.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2024
Resolved 4 April 2025
Resolution: MIs inspected permanent installation and conducted operation tests of interconnected fire detection and alarm system.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 April 2024
Resolved
The minimum clear opening of a door or passageway used as a means of escape must not be less than 810 millimeters (32 inches) in width, however, doors or passageways used solely by crew members must have a clear opening not less than 710 millimeters (28 inches).
Passenger and crew cabin doors measure less than the minimum requirement for means of escape.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2024
Resolved 8 May 2024
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 9 April 2024
Resolved
Each survival craft must be stowed in a position that is readily accessible to crew members for launching.
MI found two 25-persons life rafts not stowed in cradle.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 April 2024
Resolved 16 April 2024
Resolution: O/O submitted photograph of 02 properly installed liferafts.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 April 2024
Resolved
Each flexible cord and cable must meet the requirements in section 24.6.1 of IEEE 45-2002, Article 400 of NFPA NEC 2002, NEMA WC-3, NEMA WC-70, or UL 62 and no flexible cord may be used except (1) or (2).
MI found temporary hot start wire for Jacket Water system.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2024
Resolved 15 April 2024
Resolution: O/O submitted photograph with removal of temporary hot start wire.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 April 2024
Resolved
Each generator arranged for parallel operation must have reverse-power or reverse-current trips.
MI observed engineer unable to demonstrate reverse-power trip.
Action required: 705 - Other - as specified
Due 9 July 2024
Resolved 12 April 2024
Resolution: O/O submitted service report for satisfactory operation of reverse power relays completed by Pacific Fishermen Shipyard and Electric, LLC.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 June 2023
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Vessel suffered a machinery space fire. Provide gas free certification of CO2 released space, conduct survey of areas affected by fire and provide report of damage to attending USCG marine inspectors, prior to departing Ketchikan, AK
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 June 2023
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 11 April 2022
Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that a man overboard drill be held under simulated emergency conditions specified by inspector. Due to weather, vessel could not get underway to conduct drills. Vessel to conduct MOB drill in presence of marine inspector.
46CFR115.808
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2022
Resolution: MSD Ketchikan attended vessel and witnessed satisfactory MOB drill.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 April 2022
Resolved
A door must have a latch with a minimum throw of 20 mm (0.75 inches). Latch and door handle on door to reefer stores was loose and unable to latch. Provide proof that handle is tightened and latches properly.
46CFR116.435(c)(3)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 12 April 2022
Resolution: Marine inspector witnessed proper operation of door.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 11 April 2022
Resolved
Tubular gauge glasses must be adequately protected from mechanical damage. Sightglasses installe in tank room did not have guards to protect from damage. Provide proof that gauge glasses on port and starboard fuel tanks are adequately protected.
46CFR119.440(a)(7)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 12 April 2022
Resolution: Marine inspector observed guards installed.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 11 April 2022
Resolved
Each lighting fixture must have a guard or be made of high strength material. Light in the laundry room did not have cover. provide proof that cover has been installed.
46CFR120.410(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 12 April 2022
Resolution: Light cover installed properly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 April 2022
Resolved
Each floating waterlight must be approved IAW 161.010 in Subchapter Q. Waterlight on stern ring life buoy was inoperable. Provide proof that waterlight is operational.
46CFR117.70(d)(1)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 12 April 2022
Resolution: New waterlight installed and operational.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 April 2021
Resolved
MOB, Fire and Abandon ship drills were not conducted during inspection. Drills need to be conducted before getting underway with passengers. 46CFR115.800
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2021
Resolved 7 May 2021
Resolution: MOB, Abandon Ship and Fire Drill conducted in presence of MIs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 April 2021
Resolved
DAPI proram was not inspected, since vessel is currently not in operation. Needs to be inspected before getting underway with passengers.46CFR16.230
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2021
Resolved 15 May 2021
Resolution: Deficiency rectified. Vessel satisfied rqrmts.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 2 April 2019
Resolved
x3 Fire door don't latch shut.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2019
Resolved 19 April 2019
Resolution: all 3 fire door are now self closing and able to latch shut.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 April 2019
Resolved
x2 Fire Door gasket are worn out. FD to main engine room, and FD to emergency generator room.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2019
Resolved 19 April 2019
Resolution: new gaskets are installed on both FD.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 2 April 2019
Resolved
Fire damper in the galley was not operational
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2019
Resolved 19 April 2019
Resolution: Galley fire damper (door) can now be shut with a pull/ release.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 April 2019
Resolved
Need automation test report for x2 SSDG & x1 EDG.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2019
Resolved 19 April 2019
Resolution: Received automation reports perfored by CATS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 September 2018
Resolved
46 CFR 182.05-1: Propulsion must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its design limitations. Port engine is inoperable due to casualty to turbo oil line.
Action required: 705 - Other - as specified
Due 26 September 2018
Resolved 14 September 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 August 2018
Resolved
Prove proper operation of Starboard main engine starting system to the CG Inspector attending.
Action required: 705 - Other - as specified
Resolved 18 August 2018
Resolution: Witnessed proper operation of the Staboard Main Engine.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder
Issued 11 September 2017
Resolved
REPAIR PORT SIDE M/E AND REDUCTION GEAR TO FULL CAPABILITY
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 September 2017
Resolved 16 September 2017
Resolution: ATTENDED VESSEL DURING REPAIRS TO FIND COMPENTENT TECHNICIANS DOING A COMPLETE ENGINE OVERHAUL. RECIEVED TECH REPORT, LIFTED CG-835 PER OCMI
Accommodation/Occupational Safety › Ventilation › General
Issued 28 May 2016
Resolved
Install missing control valves for the engineroom forward & aft ventilation fans.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 13 June 2016
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 28 May 2016
Resolved
Provide missing "Simple Diagram Instructions" for remote CO2 release located passageway in a way of the CO2 locker.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 13 June 2016
Engineering › Freshwater System (jacketwater cooling) › Valve, Control
Issued 28 May 2016
Resolved
Install missing gate valve handle for the EDG keel cooler located by the through hull fitting aft lazarette bilge.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 13 June 2016
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 28 May 2016
Resolved
Install missing sewage aft deck discharge valve handle & install missing piping end cap/plug.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 13 June 2016
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 28 May 2016
Resolved
Determine locking pin found remove on the pre-engineered CO2 system in the EDG room as per vessel SMS or as per manufacturer's instructions. Correct accordingly & results found send copy to local OCMI.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 13 June 2016
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 28 May 2016
Resolved
Resolve vessel "Call Sign" as per FCC certificates. Vessel have two call signs: WDC4580 & WDF7009.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 13 June 2016
Engineering › Bilge Water Management System › Pump
Issued 15 March 2016
Resolved
Pump in mid crew void, port side failed to run, prove operation of pump.
Action required: 705 - Other - as specified
Due 15 March 2016
Resolved 15 March 2016
Resolution: Located bad electrical connection, repaired and tested sat.
Fire Fighting › Fire Main › Condition
Issued 15 March 2016
Resolved
Hole located in piping on suction side of fire pump from wastage. Repair to original scantling.
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 28 May 2016
Resolution: Done