SEALTH ARROW is a 1965 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2016, most recently in May 2026, along with 14 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 12 May 2026.

Built
1965
Last inspected
12 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 May 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCX9294
335816
Flag
UNITED STATES
Maury page id
psix-335816

Documentation record

Registered dimensions (L × B × D)53.0 ft × 12.0 ft × 7.0 ft
Registered tonnagegross 29 / net 23
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGRAFTON BOAT CO · GRAFTON, IL, UNITED STATES · built 1965
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPORT ANGELES, WA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 12 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it29 - Simplified, Gross Ton
23 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 16

12 May 2026 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8372012
27 March 2025 Deficiency Check · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8095017
2 August 2024 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7973161
6 November 2023 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7821586
18 November 2022 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7596986
7 July 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7500136
30 November 2021 Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7359803
11 September 2020 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7014076
21 July 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7008186
21 October 2019 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6838678
15 November 2018 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6581016
10 July 2018 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6464567
23 February 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6360510
16 November 2017 Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6307972
12 July 2016 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5926010
27 May 2016 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5884853

Deficiency record · 14

01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 March 2025 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of lifesaving equipment and systems, including the following: Inspection of each inflatable liferaft, inflatable buoyant apparatus, and inflatable lifejacket to determine that it has been serviced as required by § 185.730 of this chapter; O/O to provide servicing report. 46 CFR 176.808
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2025
Resolved 2 April 2025
Resolution: O/O provided proof of current servicing report.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 August 2024 Resolved
Dead end wires found in lazarette not properly terminated. Properly terminate wires or remove unused wiring.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2024
Resolved 5 August 2024
Resolution: Received photos of corrected deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 August 2024 Resolved
Wiring to light fixture in tank room bilge not secured where entering fixture. Restore stuffing tube on fixture and properly secure cable penetrating fixture.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2024
Resolved 5 August 2024
Resolution: Received photos of corrected deficiency.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 2 August 2024 Resolved
Old bulkhead penetration at bulkhead 2 is open. Properly cap unused penetrations.
Action required: 10 - Deficiency Rectified
Due 2 August 2024
Resolved 2 August 2024
Resolution: Opening properly capped.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 August 2024 Resolved
Co2 bottles have sustained significant corrosion damage and will not be considered serviceable following the next inspection date of March 2025. Replace Co2 Bottles at the end of this service period.
Action required: 705 - Other - as specified
Due 31 March 2025
Resolved 27 March 2025
Resolution: Vessel installed pre-engineered system. Vessel profile updated with system details. See also MISLE activity: 8095017.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 November 2021 Resolved
2 children Kapok life jackets found with air escaping buoyant chamber. Replace life jackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2021
Resolved 30 November 2021
Resolution: Operator purchased three new life child sized life jackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 November 2021 Resolved
Exhaust pipe lagging found with excess wear and inadequate to cover all of exhaust piping. Replace lagging. 46 CFR 177.970
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 15 December 2021
Resolution: All exhaust pipe lagging in the engine room was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 November 2021 Resolved
Batteries found with an installed in-line breaker inside battery box not in a properly mounted enclosure. 46 CFR 183.340(g)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 15 December 2021
Resolution: In-line breakers were removed.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 29 July 2020 Resolved
Repair deteriorated transverse deck stiffener at frame No. 1 portside.
Action required: 705 - Other - as specified
Resolved 11 September 2020
Resolution: Corrected as instructed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 29 July 2020 Resolved
Replace or prove the P/S FWD/AFT (4 total) water libricated bearings are within manufacturers tolerance.
Action required: 705 - Other - as specified
Resolved 11 September 2020
Resolution: Corrected as instructed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 29 July 2020 Resolved
Repair deteriorated longitudinal stiffener and add missing gusset at 6th longitudinal outboard from keel in way of connection to the transom.
Action required: 705 - Other - as specified
Resolved 11 September 2020
Resolution: Corrected as instructed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 29 July 2020 Resolved
Alighn both (P/S) weather tight doors to ensure proper fastening to prevent water ingress in pilot house.
Action required: 705 - Other - as specified
Resolved 11 September 2020
Resolution: Corrected as instructed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 29 July 2020 Resolved
Adjust watertight hatch to the tank room to ensure proper fastening to prevent water ingress.
Action required: 705 - Other - as specified
Resolved 11 September 2020
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 October 2019 Resolved
Annual Inspection - Replace batteries in life jacket lights. 46CFR185.726(d)
Action required: 10 - Deficiency Rectified
Resolved 23 October 2019
Resolution: Vessel representatives replaced all the batteries in their life jackets.

Ownership record