Records from 2005 to 2026. Most recent: inspection, 20 April 2026.
Documentation record
Registered dimensions (L × B × D)45.0 ft × 14.0 ft × 3.0 ft
Registered tonnagegross 9 / net 7
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCORINTHIAN YACHTS INC · TARPON SPRINGS, FL, UNITED STATES · built 1989
Hull materialFRP (Fiberglass)
PropulsionGasoline Engine
Hull shapeUNSPECIFIED
Hull configurationTwin Hull
Hailing portKEY LARGO, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 23 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9 - Simplified, Gross Ton
7 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 19
20 April 2026
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8340838
9 December 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8269731
9 April 2025
COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8081547
10 March 2025
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8107961
15 May 2024
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7914081
12 December 2023
Plan Review "T" Boat · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7837910
9 August 2023
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7763460
11 August 2022
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7627848
11 May 2022
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7448698
4 January 2022
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7375307
17 May 2021
Annual Inspection · DAPI Audit · Examination of Repairs · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7199321
13 May 2020
Administrative Inspection · COI Inspection · Deficiency Check · DAPI Audit · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6953939
12 December 2019
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6872837
17 October 2019
Annual Inspection · Deficiency Check · Internal Structural Exam · Administrative Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6841795
9 August 2018
Administrative Inspection · Annual Inspection · DAPI Audit · Deficiency Check · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6661202
29 November 2017
Examination of Repairs · Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6537685
12 September 2017
Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6294333
8 August 2017
Internal Structural Exam · Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6450529
16 May 2016
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5876488
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 April 2026
Resolved
05 Adult life jackets need to be replaced. Passenger count will go down 05 adults until life jackets are placed on vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 April 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 April 2026
Resolved
02 child life jackets need to be replaced. Passenger count will go down 02 children until life jackets are replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 April 2026
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 August 2022
Resolved
Anchor light not working. Make repairs and test to the satisfaction of attending CG Marine Inspector. Vessel restricted to daylight hours only until cleared.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 September 2022
Resolved 2 September 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 May 2021
Resolved
1 fire extinguisher was found low on charge. Must recharge or replace fire extinguisher prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 May 2021
Resolved 17 May 2021
Resolution: Replaced fire extinguisher
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 May 2021
Resolved
Both life floats have damage on all 4 inside corners. Must conduct repairs, paint and replace all worn retro tape on both life floats or replace with new life floats.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2021
Resolved 12 July 2021
Resolution: Repaired both life floats and repainted,labeled properly. All SAT
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 May 2021
Resolved
One life float is missing paddles and the other life float has 2 paddles that don't meet the 4 foot lenght requirements. Must replace all 4 paddles that meet requirements.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2021
Resolved 2 June 2021
Resolution: Bought 4 new paddles and labeled correctly
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 May 2021
Resolved
First aid kit had expired items. Must replace expired items to meet the requirements.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2021
Resolved 12 July 2021
Resolution: Replaced all expired items.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 May 2021
Resolved
3 child life jackets need retro tape replaced. Must replace with SOLAS retro tape.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2021
Resolved 2 June 2021
Resolution: Replaced retro on life jackets
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 May 2020
Resolved
Life ring strobe is extinguished. Repair or renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 May 2020
Resolution: New life ring strobe was purchase and renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 May 2020
Resolved
3 Adult life jackets have holes, and are no longer servicable. Renew, prior to carrying more than 46 passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 May 2020
Resolution: All 3 adult life jackets have been purchased and verified to be properly placed in service.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 13 May 2020
Resolved
Life floats must have the vessel name and float capacity clearly marked on both sides. Vessel currently only has name on one side.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 May 2020
Resolution: Name and capacity were verified to be on both sides of the life float.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 October 2019
Resolved
5 adult life jackets are wasted. Renew prior to carrying more than 48 total persons.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 October 2019
Resolution: 5 life jackets were purchased and properly put into serviced.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 17 October 2019
Resolved
Renew broken water tank vent.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 October 2019
Resolution: Water tank vent vent was replaced and in proper working order.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 October 2019
Resolved
Renew life jacket donning placard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 October 2019
Resolution: Life jacket donning placard was purchased and replaced.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 17 October 2019
Resolved
VHF must be linked to GPS and have MMSI# inputted
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 October 2019
Resolution: VHF radio was linked to GPS and MMSI number was entered into the radio.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 October 2019
Resolved
Update first aid kit with proper contents.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 October 2019
Resolution: First aid kit was renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 August 2018
Resolved
Vessel had 6 adult and 2 child PFD's that are not servicable. Vessel is restricted to not more than 43 passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 August 2018
Resolution: Renewed
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 9 August 2018
Resolved
Renew reflective tape on life ring.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 August 2018
Resolution: Renewed
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 9 August 2018
Resolved
Renew reflective tape on PFD's.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 August 2018
Resolution: Renewed
Lifesaving › Lifefloat › Retroreflective Material
Issued 8 August 2017
Resolved
Life float need new reflective material.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2017
Resolved 22 August 2017
Resolution: New SOLAS approved reflective material was properly applied to all safety gear.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 8 August 2017
Resolved
FCC safety radio certificate is not onboard. Provide.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2017
Resolved 22 August 2017
Resolution: FCC cert was provided and has been posted.
Navigation › Piloting/Steering › Magnetic Compass
Issued 8 August 2017
Resolved
Magnetic compass light is extinguished. Repair/renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2017
Resolved 22 August 2017
Resolution: LIght bulb was renewed and tested all sat.
Documentation › Certificates/Documents › Stability Letter
Issued 8 August 2017
Resolved
Vessel is missing stability letter. Provide and post.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2017
Resolved 22 August 2017
Resolution: Stability letter was provided and posted.