Records from 1989 to 2017. Most recent: inspection, 14 November 2017.
Inspection history · 130
14 November 2017
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6306990
20 April 2016
Drydock Extension · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5858857
8 March 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5829509
8 March 2016
Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5829652
8 March 2016
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5846003
23 February 2016
Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5824240
14 October 2015
Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5743913
19 September 2015
Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5723404
19 September 2015
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5725189
13 August 2014
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4959162
18 July 2012
COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4381815
11 September 2011
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4150156
5 July 2011
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4069778
28 October 2010
DAPI Audit
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3888163
14 October 2010
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3870883
14 October 2010
Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3870905
4 March 2010
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3690540
13 July 2009
Plan Review (Other than "T") · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3533665
17 July 2008
MTSA Verification · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3270994
15 April 2008
Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3143752
11 July 2007
Deficiency Check · COI Inspection · MTSA Verification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2989439
12 June 2007
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2959987
12 March 2007
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2886721
17 August 2006
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2756309
11 August 2006
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2747960
1 May 2006
MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2637901
17 April 2006
Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2626598
3 January 2006
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2559912
2 January 2006
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2561724
6 June 2005
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2378557
15 April 2005
MTSA Verification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2334980
21 March 2005
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2315829
16 March 2005
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2314106
7 January 2005
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2270941
27 December 2004
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2298911
31 October 2004
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2249938
21 June 2004
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2106330
3 May 2004
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2058234
19 April 2004
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2003917
10 February 2004
Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2004231
20 October 2003
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1932258
26 November 2002
Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1720858
27 August 2002
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1667428
23 July 2002
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1637395
13 June 2002
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1630446
1 March 2002
Deficiency Check · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1485625
4 July 2001
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 91372
4 May 2001
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 118746
11 April 2001
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 137192
25 February 2001
Examination of Repairs
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1068353
20 February 2001
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 113075
20 February 2001
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1058314
26 January 2001
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1058466
19 January 2001
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1451648
22 September 2000
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 170724
15 August 2000
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 188640
14 July 2000
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1456869
27 January 2000
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 813972
6 January 2000
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 814450
9 December 1999
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1375991
8 December 1999
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 58988
25 September 1999
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 160808
17 May 1999
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 816024
17 May 1999
Damage Survey · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1427656
12 May 1999
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 93592
25 January 1999
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1473409
20 January 1999
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1395091
1 January 1999
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 177239
17 July 1998
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 199861
17 July 1998
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 767773
10 July 1998
Hull Examination · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1434759
30 March 1998
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 786747
23 February 1998
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1467531
11 February 1998
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 107668
12 December 1997
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 676900
10 December 1997
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 159849
25 October 1997
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 151423
24 March 1997
Examination of Repairs
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1027662
21 March 1997
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1364005
10 February 1997
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1422785
7 February 1997
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 60306
10 October 1996
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 848503
23 August 1996
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1247144
12 July 1996
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1359194
27 June 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 934525
12 June 1996
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1416316
7 June 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 199859
7 June 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 754522
22 May 1996
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1086294
15 April 1996
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1357569
18 March 1996
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1377646
12 February 1996
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1396449
30 January 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 754605
29 January 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 199860
28 December 1995
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1353844
17 December 1995
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 36872
6 November 1995
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 881865
27 February 1995
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1363192
27 September 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1358540
25 September 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 27377
10 September 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 123274
16 August 1994
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1356776
1 April 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 70003
30 March 1994
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 856081
28 February 1994
COI Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1356547
2 November 1993
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1399929
29 September 1993
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1409033
6 September 1993
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 89595
30 August 1993
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 4227
12 July 1993
Plan Review "T" Boat
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1155007
7 May 1993
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 837235
8 April 1993
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1147479
8 March 1993
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 835743
15 February 1993
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 17491
9 December 1992
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1138224
8 April 1992
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1258437
10 March 1992
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1314926
11 October 1991
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1379667
16 September 1991
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 938102
16 August 1991
Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 939011
11 August 1991
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 937523
18 March 1991
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 920398
11 March 1991
Drydock Extension · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 910035
11 March 1991
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1217726
21 August 1990
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 924733
5 August 1990
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1224581
22 June 1990
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1246281
12 April 1990
Initial Certification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1232610
20 December 1989
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 919637
29 September 1989
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1005103
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 8 March 2016
Resolved
Prove proper operation of the vessels port and starboard engines prior to carrying passengers.
Action required: 705 - Other - as specified
Due 8 March 2016
Resolved 8 March 2016
Electrical › Electric Generation Source (service) › Generator
Issued 14 October 2015
Resolved
Prove proper operation of starboard generator to the satisfaction of the attending marine inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 October 2015
Resolution: Starboard main fuel tank stripped. Approximately 1 pint of water drained from tank, replaced O rings and changed fuel filters on generator.
Stability › Intact Righting Energy › General
Issued 30 October 2009
Resolved
Repair/renew and prove proper operation of Trim, Draft, and Speed Indicating (TDSI) System IAW vessel stability letter. Re-install ballast control system as original and prove proper operation. Vessel may not operate ballast system while underway until proof is provided.
Action required: 705 - Other - as specified
Due 30 April 2010
Resolved 26 April 2010
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 July 2009
Resolved
Renew expired pain medication in first aid kit.
Action required: 705 - Other - as specified
Due 15 August 2009
Resolved 30 October 2009
Navigation › Piloting/Steering › Compass Deviation Table
Issued 15 July 2009
Resolved
Provide deviation table for magnetic compass.
Action required: 705 - Other - as specified
Due 15 August 2009
Resolved 30 October 2009
Construction/Loadline › Structures › Transverse Bulkhead
Issued 15 July 2009
Resolved
Submit plans and conduct repairs to wasted frame in port forward machinery space.
Action required: 705 - Other - as specified
Due 15 August 2009
Resolved 30 October 2009
Stability › Intact Righting Energy › General
Issued 15 July 2009
Resolved
Prove proper operation of Trim, Draft, and Speed Indicating (TDSI) System in accordance with vessel stability letter. Vessel is restricted to within 5NM from shore until proof is provided.
Action required: 705 - Other - as specified
Due 15 August 2009
Resolved 30 October 2009
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 11 July 2007
Resolved
Properly secure sewage overboard valves IAW 33 CFR 159.7(c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 August 2007
Resolved 8 August 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 11 July 2007
Resolved
Provide light covers for lights in dressing room and passageway IAW 46 CFR 183.410
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 August 2007
Resolved 8 August 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 11 July 2007
Resolved
Remove halogen lights from vessel, install UL 595 approved marine grade fixtures with guards.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 August 2007
Resolved 8 August 2007
Resolution: All non-approved lighting removed from voids.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 July 2007
Resolved
Remove dead-end wires in port engine room in the vicinity of the battery box.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 August 2007
Resolved 8 August 2007
Engineering › Sea-water System (primary cooling) › Piping
Issued 11 July 2007
Resolved
Install pipe bracket on stbd generator salt water inlet piping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 August 2007
Resolved 8 August 2007
Lifesaving › Inflatable Liferafts › Servicing
Issued 11 July 2007
Resolved
Remove liferaft from vessel at the end of July. Remove instructions.
Action required: 705 - Other - as specified
Due 11 August 2007
Resolved 8 August 2007
Resolution: Inflatable life rafts removed as per OCMI approval letter dated 14 JUN 07. Ten 22-person capacity lifefloats are onboard in replacement.
Deck/Cargo › Mooring/Anchoring › Capstan
Issued 11 July 2007
Resolved
Complete repairs to anchor windlass system.
Action required: 705 - Other - as specified
Due 11 August 2007
Resolved 8 August 2007
Construction/Loadline › Structures › Scuttle
Issued 11 July 2007
Resolved
Make scuttles servicing lower steering compartments port and stbd side operable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 August 2007
Resolved 8 August 2007
Resolution: Overhauled scuttle closure mechanism and renewed gaskets.
Construction/Loadline › Structures › Deck Plating
Issued 11 July 2007
Resolved
Make repairs to main deck dance floor and starboard side 01 deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 August 2007
Resolved 8 August 2007
Resolution: Reglued deck material. Company intends to replace decking during next available drydock.
Accommodation/Occupational Safety › Ventilation › General
Issued 11 July 2007
Resolved
Properly wire exhaust fan in port hull fwd compartment.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 August 2007
Resolved 8 August 2007
Resolution: Exhaust fan and wiring removed from port forward compartment.
Accommodation/Occupational Safety › Washroom/Toilet › Washbasin
Issued 11 July 2007
Resolved
Make sink in entertainers dressing suitable for use IAW 46 CFR 176.818 or disable sink.
Action required: 705 - Other - as specified
Due 11 August 2007
Resolved 8 August 2007
Resolution: Sink and plumbing removed.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 11 July 2007
Resolved
Properly secure all refrigerators, warmers, and display cases throughout vessel.
Action required: 705 - Other - as specified
Due 11 August 2007
Resolved 8 August 2007
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 11 July 2007
Resolved
Remove broken mirror in dressing room/locker room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 August 2007
Resolved 8 August 2007
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 11 July 2007
Resolved
Replace ladders in port and stbd aft voids due to deterioration.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 August 2007
Resolved 8 August 2007
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 1 May 2006
Resolved
Provide proper operation of marine sanitation device prior to operating w/ passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2006
Resolved 4 May 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 1 May 2006
Resolved
Provide covers for all light fixtures.
Condition: Improper/Lack of Maintenance
Due 1 June 2006
Resolved 7 June 2006
Resolution: Provided covers for all light fixtures.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 1 May 2006
Resolved
Provide properly operating emergency lights in engine room.
Condition: Improper/Lack of Maintenance
Due 1 June 2006
Resolved 7 June 2006
Resolution: Provide properly operating emergency lights in engine room.
Electrical › Lighting (service) › Lighting Fixture
Issued 1 May 2006
Resolved
Provide guards around all glass light covers.
Condition: Improper/Lack of Maintenance
Due 1 June 2006
Resolved 7 June 2006
Resolution: Provide guards around all glass light covers.
Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 1 May 2006
Resolved
Fix and repair hydraulic leaks in both CPP.
Condition: Improper/Lack of Maintenance
Due 1 June 2006
Resolved 7 June 2006
Resolution: Fix and repair hydraulic leaks in both CPP.
Engineering › Steering Gear System › Actuator
Issued 3 January 2006
Resolved
Prop pitch control system damaged by leaking Generator Jacket water system.
Condition: Damaged By Earlier Event
Due 3 February 2006
Resolved 17 February 2006
Personnel › Training › Crisis Management/Human Behaviour
Issued 3 May 2004
Resolved
Implement deckhand identification and training. Ensure familiarity with assigned duties for all emergency scenarios per 46 CFR 122.420, 122.520, and 122.514.
Due 3 June 2004
Resolved 21 June 2004
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 3 May 2004
Resolved
Replace fire protection insulation in interior below ladderwell space as per 46 CFR 177.405.
Due 3 June 2004
Resolved 7 July 2004
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 3 May 2004
Resolved
Remove bamboo wall coverings from bar, photoshop, and gift shop as per 46 CFR 177.405.
Due 3 June 2004
Resolved 21 June 2004
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 3 May 2004
Resolved
Remove excess non-essential carpeting and combustible materials as per 46 CFR 177.405.
Due 3 June 2004
Resolved 21 June 2004
Electrical › Electric Generation Source (service) › Generator Cable
Issued 3 May 2004
Resolved
Remove excess wiring over port main generator as per 46 CFR 183.340.
Due 3 June 2004
Resolved 21 June 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 3 May 2004
Resolved
Ensure ease of access to portable fire extinguisher in port main generator space as per 46 CFR 181.520 (covered with hoses at present).
Due 3 June 2004
Resolved 21 June 2004
Engineering › Diesel Engine (propulsion-direct drive) › Piping (air intake)
Issued 3 May 2004
Resolved
Repair vent supply ducting in port main engine space as per 46 CFR 182.465.
Due 3 June 2004
Resolved 7 July 2004
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 3 May 2004
Resolved
Replace bulb in emergency light in stbd main generator space as per 46 CFR 184.30-1.
Due 3 June 2004
Resolved 21 June 2004
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 3 May 2004
Resolved
Replace bulb in emergency light in stbd main engine space as per 46 CFR 184.30-1.
Due 3 June 2004
Resolved 21 June 2004
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 3 May 2004
Resolved
Repair flame impingement bowl attachment on stbd main generator.
Due 3 June 2004
Resolved 21 June 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 May 2004
Resolved
Remove plastic wire tie supports on electrical cables in engine room and generator space. Must use proper metallic supports in engine spaces as per 46 CFR 183.340. LEGACY COMPONENT DESC: Wiring
Due 3 June 2004
Resolved 20 July 2004
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 3 May 2004
Resolved
Prove fire-resistance of draperies and curtains covering closets, windows, etc. as per 46 CFR 116.423. LEGACY COMPONENT DESC: Furniture/Furnishings
Due 3 June 2004
Resolved 20 July 2004
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 3 May 2004
Resolved
Mark maximum upper deck passenger limit on stairway leading up to 02 deck as per 46 CFR 185.602(g). LEGACY COMPONENT DESC: Pax Capacity Markings
Due 3 June 2004
Resolved 21 June 2004
Fire Fighting › Firemans Outfit › Axe
Issued 3 May 2004
Resolved
Mark vessel name on stbd fire axe. LEGACY COMPONENT DESC: Axe
Due 3 June 2004
Resolved 21 June 2004
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 3 May 2004
Resolved
Replace bulb in emergency light in port engine space at entrance as per 46 CFR 184.30-1.
Due 3 June 2004
Resolved 21 June 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 3 May 2004
Resolved
Remove Christmas lights and extension cords from all areas of vessel, especially in galley, bars and bridge as per 46 CFR 183.220.
Due 3 June 2004
Resolved 7 July 2004
Construction/Loadline › Structures › Superstructure
Issued 23 April 2004
Resolved
Crop and renew both sides of aluminum yoke for mounting brackets on the following mounts: Portside: 4, 6, 7, 14; Starboardside: 4, 5, 6, 7, 9, 10, 12.
Condition: Improper/Lack of Maintenance
Due 31 July 2004
Resolved 20 July 2004
Construction/Loadline › Structures › Superstructure
Issued 16 April 2004
Resolved
Crop and renew one side of aluminum yoke for mounting bracket on the following mounts: Portside: 2, 3, 4, 9, 10; Starboardside: 3, 8, 11, 13, 15, 16.
Due 31 July 2004
Resolved 20 July 2004
Lifesaving › Lifebuoys
Issued 20 October 2003
Resolved
Repair bottom support bracket on lifebuoy located on port side forward. LEGACY COMPONENT DESC: Bracket
Due 20 November 2003
Resolved 3 May 2004
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 20 October 2003
Resolved
Repair/tighten starboard aft ladder (main deck).
Due 20 November 2003
Resolved 23 April 2004
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 20 October 2003
Resolved
Install flame screen on port sewage vent. LEGACY COMPONENT DESC: Sewage vent
Due 20 November 2003
Resolved 23 April 2004
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 20 October 2003
Resolved
Install vent head for starboard sewage vent. LEGACY COMPONENT DESC: Vent head
Due 20 November 2003
Resolved 23 April 2004
Lifesaving › Lifebuoys
Issued 20 October 2003
Resolved
Install 3 foot lanyard and corrosion resistant clip on waterlight for ring buoy (01 deck). LEGACY COMPONENT DESC: Buoyant Lifeline
Due 20 November 2003
Resolved 3 May 2004
Lifesaving › Lifebuoys
Issued 20 October 2003
Resolved
Replace lanyard on waterlight for 02 deck ring buoy. LEGACY COMPONENT DESC: Self-igniting Lights
Due 20 November 2003
Resolved 3 May 2004
Stability › Weathertight Integrity
Issued 20 October 2003
Resolved
Install rubber gaskets on all doors. LEGACY COMPONENT DESC: Doors
Due 20 November 2003
Resolved 3 May 2004
Electrical › Electric Supply System (service)
Issued 20 October 2003
Resolved
Ensure there are no "double" extension cord connections for musical/entertainment equipment. LEGACY COMPONENT DESC: Extension cord use
Due 20 November 2003
Resolved 3 May 2004
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 20 October 2003
Resolved
Replace fire sleeves on port main engine's fuel line and secure with non-combustible materials.
Due 20 November 2003
Resolved 23 April 2004
Engineering › Fuel Oil Service System › Suction Strainer
Issued 20 October 2003
Resolved
Provide plugs for fuel strainers on starboard main engine.
Due 20 November 2003
Resolved 23 April 2004
Engineering › Sea-water System (primary cooling) › Piping
Issued 20 October 2003
Resolved
Replace raw water cooling intake hose on starboard generator.
Due 20 November 2003
Resolved 23 April 2004
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 20 October 2003
Resolved
Remove paint from gasket on ventilation closure for machinery space.
Due 20 November 2003
Resolved 23 April 2004
Lifesaving › Lifejacket/PFD (General)
Issued 20 October 2003
Resolved
Remove/repair/ensure doors for lifejacket container (main deck, center box) do not interfere with emergency escape route. LEGACY COMPONENT DESC: Storage
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2003
Resolved 20 October 2003
Resolution: Hinges on doors were reversed so as to not interfere with escape route.
Engineering › Steering Gear System
Issued 20 October 2003
Resolved
Repair light on bridge for port steering gear pump. LEGACY COMPONENT DESC: Light on bridge
Due 20 November 2003
Resolved 3 May 2004
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 20 October 2003
Resolved
Prove TDSI system is accurate for recording draft marks.
Due 20 November 2003
Resolved 21 June 2004
Electrical › Lighting (service)
Issued 23 July 2002
Resolved
Replace/repair light fixtures in port working space IAW 46CFR 120.410
Condition: Unknown
Due 23 July 2002
Resolved 27 August 2002
Electrical › Electrical Distribution System (service)
Issued 23 July 2002
Resolved
Repair buss interlock system IAW 46CFR120.330
Condition: Unknown
Due 5 August 2002
Resolved 27 August 2002
Engineering › Fuel Oil Service System
Issued 23 July 2002
Resolved
Provide flame shield or replace fuel oil hose on main engines IAW 46 CFR 119.45 LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Due 30 July 2002
Resolved 27 August 2002
Electrical › Electrical Distribution System (service)
Issued 23 July 2002
Resolved
Repair 24 Volt Ground Fault Light IAW 46CFR 120.330 LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Improper/Lack of Maintenance
Due 23 July 2002
Resolved 27 August 2002
Construction/Loadline › Hull › Bottom Plating
Issued 13 June 2002
Resolved
Paint repairs conducted at last drydock in port and starboard ballast tanks.
Due 13 June 2002
Resolved 13 June 2002
Resolution: Rep. painted areas.
Construction/Loadline › Penetrations
Issued 13 June 2002
Resolved
Pull all overboard and suction valves below water lined for inspection. LEGACY COMPONENT DESC: Overboard discharge and suction valves.
Due 13 June 2002
Resolved 13 June 2002
Resolution: Rep. pulled valves for inspection.
Construction/Loadline › Structures › Manhole
Issued 13 June 2002
Resolved
Pull port and stbd water tank anf void space manhole covers and make tanks ready for inspection.
Due 13 June 2002
Resolved 13 June 2002
Resolution: Rep. removed covers and made tanks ready for inspection.
Construction/Loadline › Structures
Issued 13 June 2002
Resolved
Replace stringer in starboard stinger space on inboard side. LEGACY COMPONENT DESC: Stringes
Condition: Improper/Lack of Maintenance
Due 13 June 2002
Resolved 13 June 2002
Resolution: Rep. replaced stringer.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 13 June 2002
Resolved
Replace double hose clamps on generator cooling line on port generator. LEGACY COMPONENT DESC: Hose clamps
Condition: Improper/Lack of Maintenance
Due 13 June 2002
Resolved 13 June 2002
Resolution: Rep. replaced double hose clamps.
Deck/Cargo › Mooring/Anchoring › Capstan
Issued 13 June 2002
Resolved
Replace/repair corroded hydralic lines to capstan in port and starboard #1 hold.
Condition: Improper/Lack of Maintenance
Due 13 June 2002
Resolved 13 June 2002
Resolution: Rep. replaced lines.
Engineering › Steering Gear System › Piping
Issued 13 June 2002
Resolved
Replace/repair hydralic lines to steering in aft freeman hatch on starboard side.
Condition: Improper/Lack of Maintenance
Due 13 June 2002
Resolved 13 June 2002
Resolution: Rep. replaced hydralic lines.
Construction/Loadline › Structures
Issued 14 May 2002
Resolved
Replace stringer in port side stringer space outboard side and overhead stringer adjacent to hatch. LEGACY COMPONENT DESC: Stringer
Condition: Improper/Lack of Maintenance
Due 30 May 2002
Resolved 30 May 2002
Resolution: Rep. replaced stringers.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 14 May 2002
Resolved
Repair exhaust leak on port generator. LEGACY COMPONENT DESC: Exhaust leak
Due 30 May 2002
Resolved 30 May 2002
Resolution: Rep. repaired exhaust leak.
Construction/Loadline › Hull
Issued 1 March 2002
Resolved
Replace gaskets on all watertight doors in accordance with 46 CFR 171.124. LEGACY COMPONENT DESC: WTD Gaskets
Due 1 March 2002
Resolved 8 March 2002
Resolution: Vessel operator replaced the gaskets on all watertight doors on the vessel.
Lifesaving › Lifejacket/PFD (Type III)
Issued 1 March 2002
Resolved
Properly stow extra adult lifejacket in accordance with 46 CFR 180.78. LEGACY COMPONENT DESC: Storage
Due 1 March 2002
Resolved 8 March 2002
Resolution: Vessel operator properly stowed extra adult lifejacket.
Lifesaving › Lifebuoys
Issued 1 March 2002
Resolved
Replace deteriorated ring lifebuoys in accordance with 46 CFR 180.70. LEGACY COMPONENT DESC: Ring Lifebuoy
Due 1 March 2002
Resolved 8 March 2002
Resolution: Vessel operator reoplaced deteriorated ring lifebuoys.
Lifesaving
Issued 26 January 2001
Resolved
Passenger count is reduced to 351 persons until 30 additional adult lifejackets are provided in accordance with 46 CFR 117.71.
Condition: Unknown
Due 19 February 2001
Resolved 20 February 2001
Documentation
Issued 19 January 2001
Resolved
Provide proof of required training and employee assistance program in accordance with 46CFR16.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Lifesaving
Issued 19 January 2001
Resolved
Replace retro-reflective tape on 112 adult and 22 child lifejackets in accordance with 46CFR122.604.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Electrical
Issued 19 January 2001
Resolved
Provide suitable guards for deck light fixtures at top of spiral staircasesand on 2nd deck level after deck in accordance with 46CFR120.410.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Lifesaving
Issued 19 January 2001
Resolved
Label lifejacket lockers in accordance with 46CFR117.78.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Lifesaving
Issued 19 January 2001
Resolved
Passenger count is reduced to 338 until additional lifejackets are brought on_x001C_ board to replace lifejackets rejected during the inspection in accordance with 46CFR117.71.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Lifesaving
Issued 19 January 2001
Resolved
Provide documentation as proof for EPIRB tests in accordance with 46CFR122.728(c).
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Electrical
Issued 19 January 2001
Resolved
Make permanent repairs to cable way in starboard stinger space in_x001C_ accordance with 46CFR120.340(b).
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Engineering
Issued 9 December 1999
Resolved
Repair or replace 24 volt battery charging system for starboard main governor IAW 46 CFR 182.05.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Construction/Loadline
Issued 9 December 1999
Resolved
Repair as original potable water piping starboard side void IAW 46 CFR176.05-10.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Navigation
Issued 9 December 1999
Resolved
Provide Coast Guast Light List, Tide tables and Current tables IAW 46 CFR 184.420.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Documentation
Issued 9 December 1999
Resolved
Prove compliance with operational readiness, maintenance, and inspection oflifesaving equipment records IAW 46 CFR 185.700, 702, 720, 722, 724, and 728.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Electrical
Issued 9 December 1999
Resolved
Install safety guard on electrical fan in crew locker room IAW 46 CFR 176.25-15(a).
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Fire Fighting
Issued 9 December 1999
Resolved
Repair structural fire protection in electrical distribution space IAW 46 CFR 177.10-5.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Deck/Cargo
Issued 17 May 1999
Resolved
Repair or replace starboard air reciever pressure relief valve.
Condition: Unknown
Due 7 June 1999
Resolved 9 June 1999
Engineering
Issued 25 January 1999
Resolved
Repair inoperative port side oil pressure gauge at operating station.
Condition: Unknown
Due 26 February 1999
Resolved 26 February 1999
Unknown
Issued 25 January 1999
Resolved
Conduct port and stbd pressure vessel examinations prior to 14MAY99.
Condition: Unknown
Due 25 January 1999
Resolved 25 January 1999
Navigation
Issued 25 January 1999
Resolved
Repair inoperative draft and trim indicating system.
Condition: Unknown
Due 25 February 1999
Resolved 26 February 1999
Construction/Loadline
Issued 10 July 1998
Resolved
Make ready for inspection port and stbd #2 ballast tanks by mechanical cleaning to remove existing coating system. Apply new coating system aftersatisfactory inspection by USCG marine inspector.
Condition: Unknown
Due 8 September 1998
Resolved 3 August 1998
Construction/Loadline
Issued 10 July 1998
Resolved
Treat corroded frames in stbd forepeak approximately 5 feet above ballast tank.
Condition: Unknown
Due 9 August 1998
Resolved 3 August 1998
Navigation
Issued 10 July 1998
Resolved
Repair hydraulic leak on stbd steering rams.
Condition: Unknown
Due 9 August 1998
Resolved 3 August 1998
Navigation
Issued 10 July 1998
Resolved
Repair hangers for stbd steering wiring.
Condition: Unknown
Due 9 August 1998
Resolved 3 August 1998
Navigation
Issued 10 July 1998
Resolved
Repair/tighten leaking hydraulic lines for port steering system.
Condition: Unknown
Due 9 August 1998
Resolved 3 August 1998
Engineering
Issued 10 July 1998
Resolved
Replace all corroded portions of port and stbd fuel full, fuel vent, and potable water vent.
Condition: Unknown
Due 9 August 1998
Resolved 3 August 1998
Construction/Loadline
Issued 12 June 1996
Resolved
REPLACE RUBBER INSERT ON PORT ENGINE ROOM BILGE LINE WITH WELDED-IN METALLIC INSERT.
Condition: Unknown
Due 12 June 1996
Resolved 12 June 1996
Construction/Loadline
Issued 12 June 1996
Resolved
CROP OUT AND RENEW AS ORIGINAL, OVERHEAD STIFFENER LOCATED BEHIND BALLAST AIR BLOWER IN PORT FWD MACHINERY SPACE.
Condition: Unknown
Due 12 June 1996
Resolved 12 June 1996
Accommodation/Occupational Safety
Issued 12 June 1996
Resolved
REPAIR OR REPLACE STBD POTABLE WATER ACCUMULATOR.
Condition: Unknown
Due 12 June 1996
Resolved 12 June 1996
Engineering
Issued 12 June 1996
Resolved
DOUBLE CLAMP PORT ENGINE ROOM RAW WATER DISCHARGE LINE.
Condition: Unknown
Due 12 June 1996
Resolved 12 June 1996
Lifesaving
Issued 12 June 1996
Resolved
REPLACE FOAM COAMING IN OVERHEAD LOCATED ABOVE GALLEY LADDER.
Condition: Unknown
Due 12 June 1996
Resolved 12 June 1996
Accommodation/Occupational Safety
Issued 12 June 1996
Resolved
REPLACE TWO CRACKED WINDOWS LOCATED IN MAIN DECK LOUNGE.
Condition: Unknown
Due 12 June 1996
Resolved 12 June 1996
Accommodation/Occupational Safety
Issued 12 June 1996
Resolved
REPLACE TWO CRACKED WINDOWS LOCATED IN O-1 DECK LOUNGE.
Condition: Unknown
Due 12 June 1996
Resolved 12 June 1996
Unknown
Issued 12 June 1996
Resolved
CLEAN OUT STARBOARD AIR RECEIVER SO THAT IT CAN BE PROPERLY INSPECTED BY A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 12 June 1996
Resolved 12 June 1996
Lifesaving
Issued 18 March 1996
Resolved
Conduct and log monthly inspection of the survival craft in accordance with46 CFR 122.722.
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Electrical
Issued 18 March 1996
Resolved
Provide portable lights in accordance with 46 CFR 120.430.
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Lifesaving
Issued 18 March 1996
Resolved
Provide manufacturer maintenance and inspection instructions for the survival craft in accordance with 46 CFR 122.702.
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Lifesaving
Issued 18 March 1996
Resolved
Conduct and log weekly maintenance and inspection of the survival craft in accordance with 46 CFR 122.720.
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Fire Fighting
Issued 12 February 1996
Resolved
Provide and properly install insulation for overhead in the electrical shop.
Condition: Unknown
Due 25 March 1996
Resolved 25 March 1996
Accommodation/Occupational Safety
Issued 12 February 1996
Resolved
Provide and properly install protective guard for electrical shop supply vent.
Condition: Unknown
Due 25 March 1996
Resolved 25 March 1996
Engineering
Issued 12 February 1996
Resolved
Properly secure disabled port potable water tank fill.
Condition: Unknown
Due 25 March 1996
Resolved 25 March 1996
Construction/Loadline
Issued 12 February 1996
Resolved
Renew as original, in lieu of soft patch, port bilge/fire main connection piping. Vessel is restricted from carrying passengers for hire beginning on 13FEB96 until requirement is completed.
Condition: Unknown
Due 21 February 1996
Resolved 21 February 1996
Fire Fighting
Issued 12 February 1996
Resolved
Provide and properly install as per original, the fire screen doors (2) to the aft food preparation area, main deck.
Condition: Unknown
Due 12 February 1996
Resolved 12 February 1996
Construction/Loadline
Issued 12 February 1996
Resolved
Provide and prove proper operation of hand portable fire pump with suitablelength hoses.
Condition: Unknown
Due 12 February 1996
Resolved 12 February 1996
Lifesaving
Issued 12 February 1996
Resolved
Properly service by an approved facility inflatable bouyant apparatus'_x001C_ #3569-50BB by 10APR96, #2916-50BB by 15APR96, and #3570-50BB by 09MAY96.
Condition: Unknown
Due 12 February 1996
Resolved 12 February 1996
Construction/Loadline
Issued 12 February 1996
Resolved
Provide as per original watertight hatches for the port and starboard steering spaces access hatches, in lieu of the installed aluminum panels.
Condition: Unknown
Due 25 March 1996
Resolved 25 March 1996
Accommodation/Occupational Safety
Issued 12 February 1996
Resolved
Provide adequate securing device (padlock, non-releaseable wire-tie, or removal of the valve handle) for MSD overboard discharge valve.
Condition: Unknown
Due 25 March 1996
Resolved 25 March 1996
Construction/Loadline
Issued 12 February 1996
Resolved
Conduct operational test of the port bilge/fire main connection "T" in the presence of a USCG marine inspector.
Condition: Unknown
Due 25 March 1996
Resolved 25 March 1996
Engineering
Issued 12 February 1996
Resolved
Renew fuel fill pipe hose, starboard side potable water tank void.
Condition: Unknown
Due 25 March 1996
Resolved 25 March 1996
Accommodation/Occupational Safety
Issued 12 February 1996
Resolved
Renew access doors gaskets as needed for the upper and lower accommodation spaces.
Condition: Unknown
Due 12 February 1996
Resolved 12 February 1996
Engineering
Issued 12 February 1996
Resolved
Conduct safety tests for both MDE's and SSG's to include overspeed, low oilpressure, and high water temperature.
Condition: Unknown
Due 25 March 1996
Resolved 25 March 1996
Fire Fighting
Issued 12 February 1996
Resolved
Provide and install as per original, the fire screen door to the aft food_x001C_ preparation area, 01 deck.
Condition: Unknown
Due 12 February 1996
Resolved 12 February 1996
Navigation
Issued 12 February 1996
Resolved
Renew as original, 1" hydraulic piping for the vessel's stabilizer system, forepeak spaces, port and starboard.
Condition: Unknown
Due 12 February 1996
Resolved 12 February 1996
Unknown
Issued 6 November 1995
Resolved
REPOSITION NAVIGATION SIDE LIGHTS/MASTHEAD LIGHT IAW COLREGS, ANNEX I 84.05(c). (Navigation side lights are forward of the forward masthead light.)
Condition: Unknown
Due 6 November 1995
Resolved 6 November 1995
Electrical
Issued 27 February 1995
Resolved
SECURE PANEL FRONT OF ELECTRIC BOX 24P IN MAIN ELECTRICAL ROOM.
Condition: Unknown
Due 27 February 1995
Resolved 27 February 1995
Electrical
Issued 27 February 1995
Resolved
PROVIDE HARDWIRED ELECTRICAL OUTLETS FOR GALLEY EQUIPMENT AT STARBOARD AFT BUSSING STATION.
Condition: Unknown
Due 27 February 1995
Resolved 27 February 1995
Accommodation/Occupational Safety
Issued 27 February 1995
Resolved
PROVIDE SECURE MOUNTINGS FOR GALLEY EQUIPMENT AT STARBOARD AFT BUSSING STATION.
Condition: Unknown
Due 27 February 1995
Resolved 27 February 1995
Accommodation/Occupational Safety
Issued 27 February 1995
Resolved
SECURE ALL TREAD RISERS FOR STARBOARD AFT GALLEY STAIRS.
Condition: Unknown
Due 27 February 1995
Resolved 27 February 1995
Fire Fighting
Issued 27 February 1995
Resolved
PROVIDE CABLE PASS STUFFING FOR CABLE PASS ON DECK BELOW BOX 24P IN MAIN ELECTRICAL ROOM.
Condition: Unknown
Due 27 February 1995
Resolved 27 February 1995
Electrical
Issued 27 February 1995
Resolved
REPAIR SUPPORT STANCHION FOR CABLES ABOVE STARBOARD GEARBOX.
Condition: Unknown
Due 27 February 1995
Resolved 27 February 1995
Engineering
Issued 27 September 1994
Resolved
VESSEL TO PROVIDE ASSIST TUG FOR DOCKING AND UNDOCKING UNITL REPAIRS TO PORT GEAR BOX SEAL IS COMPLETED.
Condition: Unknown
Due 29 September 1994
Resolved 29 September 1994
Electrical
Issued 28 February 1994
Resolved
REPAIR LEAK IN COOLING WATER LINE ON STBD SHIP SERVICE GENERATOR, (LEAK LOCATED NEAR CHECK VALVE).
Condition: Unknown
Due 7 March 1994
Resolved 11 March 1994
Construction/Loadline
Issued 28 February 1994
Resolved
REWORK VALVES/VENT ASSEMBLIES LOCATED BETWEEN LIFE FLOATS AND FOR #2 STBD COMPARTMENTS.
Condition: Unknown
Due 7 March 1994
Resolved 11 March 1994
Navigation
Issued 28 February 1994
Resolved
REPLACE WASTED SECTION OF HYDRAULIC STEERING PIPE LOCATED AT THE BOTTOM OF LADDER LEADING TO STEERING SYSTEM ON PORT SIDE.
Condition: Unknown
Due 28 February 1994
Resolved 28 February 1994
Lifesaving
Issued 28 February 1994
Resolved
CONDUCT UNDERWAY DRILLS IN THE PRESENCE OF A MARINE INSPECTOR
Condition: Unknown
Due 7 March 1994
Resolved 11 March 1994
Navigation
Issued 28 February 1994
Resolved
PROVIDE AND MAINTAIN A CHART OF THE VESSELS OPERATING AREA ON BOARD THE VESSEL.
Condition: Unknown
Due 7 March 1994
Resolved 11 March 1994
Engineering
Issued 28 February 1994
Resolved
PROVE OVERSPEED TRIPS OPERATIVE ON BOTH MDE'S.
Condition: Unknown
Due 7 March 1994
Resolved 11 March 1994
Engineering
Issued 8 March 1993
Resolved
MAKE PRESSURE VESSELS READY FOR INTERNAL INSPECTION OR HYDROSTATIC TESTING.
Condition: Unknown
Due 8 March 1993
Resolved 8 March 1993
Electrical
Issued 8 March 1993
Resolved
DEMONSTRATE OPERATIONAL TEST OF OVERSPEED, LOW LUBE OIL PRESSURE AND HIGH WATER TEMPERATURE SHUTDOWNS ON EACH SHIP SERVICE GENERATOR.
Condition: Unknown
Due 8 March 1993
Resolved 8 March 1993
Construction/Loadline
Issued 8 March 1993
Resolved
RENEW RUPTURED SECTION OF THE DISCHARGE PIPING, LOCATED AT THE STBD BILGE PUMP.
Condition: Unknown
Due 8 March 1993
Resolved 8 March 1993
Navigation
Issued 8 March 1993
Resolved
RENEW STBD RUDDER STOCK PACKING.
Condition: Unknown
Due 8 March 1993
Resolved 8 March 1993
Lifesaving
Issued 8 March 1993
Resolved
REPAIR MAIN ENGINE EMERGENCY ALARM RED LIGHT IN EACH ENGINE ROOM.
Condition: Unknown
Due 8 March 1993
Resolved 8 March 1993
Engineering
Issued 8 March 1993
Resolved
DEMONSTRATE OPERATIONAL TEST OF OVERSPEED, LOW LUBE OIL PRESSURE AND HIGH WATER TEMPERATURE SHUTDOWNS/ALARMS ON EACH MAIN DIESEL ENGINE.
Condition: Unknown
Due 8 March 1993
Resolved 8 March 1993
Construction/Loadline
Issued 8 March 1993
Resolved
RENEW CAPTIVE CHAIN FOR LAZERETTE HATCH.
Condition: Unknown
Due 8 March 1993
Resolved 8 March 1993
Electrical
Issued 10 March 1992
Resolved
TEST OVERSPEED TRIP FOR THE STARBOARD GENERATOR.
Condition: Unknown
Due 10 March 1992
Resolved 10 March 1992
Lifesaving
Issued 10 March 1992
Resolved
SERVICE INFLATABLE RAFTS/BUOYANT APPARATUS AS REQUIRED. TOTAL PERSONS ONBOARD IS REDUCED BY 75 ON OCEANS ROUTE UNTIL COMPLIANCE.
Condition: Unknown
Due 10 March 1992
Resolved 10 March 1992
Accommodation/Occupational Safety
Issued 16 September 1991
Resolved
REPLACE FLEXIBLE PIPING TO NEW FRESH WATER TANKS WITH PROPER RIGID PIPING.
Condition: Unknown
Due 16 September 1991
Resolved 16 September 1991
Construction/Loadline
Issued 16 September 1991
Resolved
PROVIDE PLANS FOR ELECTRICAL WIRING CHANGES AND NEW THROUGH HULL PIPING.
Condition: Unknown
Due 16 September 1991
Resolved 16 September 1991
Engineering
Issued 16 August 1991
Resolved
MAKE REPAIRS TO STARBOARD CLUTCH DRIVE ASSEMBLY TO THE SATISFACTION OF THE OCMI'S REP.
Condition: Unknown
Due 16 August 1991
Resolved 16 August 1991
Engineering
Issued 11 March 1991
Resolved
PROVE OPERATION OF THE HIGH JACKET WATER TEMPERATURE ALARM ON BOTH MAIN DIESEL ENGINES._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 March 1991
Resolved 11 March 1991
Engineering
Issued 11 March 1991
Resolved
PROVE OPERATION OF THE PRESSURE RELIEF VALVE ON THE PORT AIR RECEIVER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 March 1991
Resolved 11 March 1991
Electrical
Issued 11 March 1991
Resolved
PROVE OPERATION OF THE DIESEL GENERATOR (STBD) OVERSPEED TRIP._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 March 1991
Resolved 11 March 1991
Fire Fighting
Issued 12 April 1990
Resolved
FIT STEEL SHUTTERS IN AFT PILOTHOUSE BULKHEAD. DEMONSTRATE OPERATION TO A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 12 April 1990
Resolved 12 April 1990