MAURY USCG vessel records Sign in
← All vessels

VITAGLORY

VITAGLORY is a 1989 freight ship. The Coast Guard has recorded 22 inspections since 1989, most recently in February 2011, along with 12 deficiencies and 1 operational control.

Records from 1989 to 2011. Most recent: inspection, 8 February 2011.

Built
1989
Last inspected
8 February 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8818881 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
336453
Flag
MALTA
—
Maury page id
psix-336453

Inspections, by type

…with no type recorded10
Years with a record 13 calendar years (1989–2011)
The 22 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it23033 - Convention (Subpart B), Net Ton
36284 - Convention (Subpart B), Gross Ton
69703 - Dead Weight, Ton
79722 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 22

8 February 2011 Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3941481
26 January 2011 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3929769
25 January 2011 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3929830
28 February 2009 ISPS II Exam · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3425569
21 June 2008 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3243332
29 January 2008 Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 3138283
23 October 2006 PII Safety Exam · MARPOL Annex I Examination · Ballast Water Examination · ISPS III Exam · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2805776
10 July 2006 Ballast Water Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2706852
3 June 2005 Ballast Water Examination · PII Safety Exam · ISPS III Exam · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2375922
10 November 2004 Ballast Water Examination · PII Safety Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2238390
23 August 2004 ISPS II Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2173721
18 March 2004 Passenger/Freight Vessel Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2026617
7 October 2002 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1682873
4 October 2002 Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 1692089
17 April 2002 Annual Inspection · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1605761
27 July 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 280376
23 February 2000 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 274954
5 May 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 428311
5 October 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 383540
3 June 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 367481
6 February 1991 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 341742
17 August 1989 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 332232

Deficiency record · 12

Deck/Cargo › Holds/Tanks › Coaming
Issued 26 January 2011 Resolved
Vessel has a hydraulic ram used to lock down cargo bay hatch #2 leaking hydraulic oil on the deck.
Action required: 705 - Other - as specified
Due 9 February 2011
Resolved 9 February 2011
Resolution: Vessel has replaced hydraulic ram used to lock down cargo bay hatch #2 and is no longer leaking oil on deck.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 26 January 2011 Resolved
Multiple self closing class "A" fire doors along the main stairway of accommodation spaces do not operate properly.
Due 26 January 2011
Resolved 26 January 2011
Resolution: Doors latching arrangement and self closing devises were repaired as needed.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 26 January 2011 Resolved
Multiple high voltage panels throughout the vessel are missing electrical safe matting as required
Due 26 January 2011
Resolved 26 January 2011
Resolution: Vessels crew placed electrical safe matting at all required locations.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 10 November 2004 Resolved
VESSELS STEERING GEAR ROOM DID NOT HAVE HANDRAILS OR NON-SLIP SURFACE. DEFICIENCY WAS CORRECTED ON THE SPOT. CITE SOLAS CH. II-I 13.2
Condition: Improper/Lack of Maintenance
Due 10 November 2004
Resolved 10 November 2004
Resolution: NON SLIP MATTING WAS PROVIDED.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 10 November 2004 Resolved
VESSELS HOSPITAL TOILET DID NOT FLUSH. DEFICIENCY WAS CORRECTED ON THE SPOT. CITE ILO 147
Due 10 November 2004
Resolved 10 November 2004
Resolution: TOILET WAS FIXED
Deck/Cargo › Holds/Tanks
Issued 17 April 2002 Resolved
FOUND BROKEN HATCH COMBINGS ON #3 HOLD, 1 CENTER FWD, 2 PORT AFT. ON #4 HOLD, 1 STBD SIDE AND ON PORT AFT SIDE. ON #5 HOLD, ONE PORT AND STBD FWD. SEVERAL CRACKS HAD DOUBLERS ON ONE SIDE AND CRACK WAS NOT WELDED. REPAIR BRACKETS TO SATISFACTION OF CLASS SOCIETY LEGACY COMPONENT DESC: Coaming
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 May 2002
Resolved 7 October 2002
Resolution: Received a class report via fax attesting to the repairs of hatch combings.
Construction/Loadline › Hull
Issued 17 April 2002 Resolved
FOUND SEVERAL HOLES AND WASTED PIPES IN BOSUN STORES IN TE CHAIN WASH SYSTEM ON BOTH PORT AND STBD SIDES. LEGACY COMPONENT DESC: ANCHOR WASH
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 May 2002
Resolved 7 October 2002
Resolution: Received a class report attesting to the repairs of holes and pipes in bosun stores.
Electrical › Lighting (service)
Issued 17 April 2002 Resolved
EXPOSED AND INCORRECTLY WIRED WALL SWITCH AND LIGHT, A POTENTIAL SHOCK HAZARD FOUND IN HOSPITAL SPACE. LEGACY COMPONENT DESC: INCORRECTLY WIRED LIGHT
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 23 May 2002
Resolved 7 October 2002
Resolution: Received a class report via fax attesting to the repair of the exposed and incorrectly wired wall switch and light.
Documentation
Issued 6 February 1991 Resolved
VESSELS OIL RECORD BOOK ENTRIES WERE NOT MADE IAW THE INSTRUCTIONS AS REQUIRED BY 33CFR151.25(d)
Condition: Unknown
Due 5 October 1995
Resolved 5 October 1995
Documentation
Issued 6 February 1991 Resolved
VESSELS IOPP CERTIFICATE WAS MISSING THE SUPPLEMENT REQUIRED BY 33CFR151.19(d).
Condition: Unknown
Due 5 October 1995
Resolved 5 October 1995
Engineering
Issued 6 February 1991 Resolved
VESSELS OILY WATER SEPERATOR 15ppm ALARM WAS FOUND TO BE INOPERATIVE, THIS IN VIOLATION OF 33CFR155.380(b).
Condition: Unknown
Due 6 February 1991
Resolved 6 February 1991
Fire Fighting
Issued 6 February 1991 Resolved
VESSELS CREW WAS UNABLE TO DEMONSTRATE THE OPERATION OF THE EMERGANCY FIRE PUMP REQUIRED SOLAS 74'CH. II-2 PART A REG 4.3.3.2.
Condition: Unknown
Due 6 February 1991
Resolved 6 February 1991

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.