MAURY USCG vessel records Sign in
← All vessels

LUCY PG

LUCY PG is a 1974 tank ship. The Coast Guard has recorded 11 inspections since 1989, most recently in March 1993, along with 5 deficiencies.

Records from 1989 to 1993. Most recent: inspection, 11 March 1993.

Built
1974
Last inspected
11 March 1993
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7336642 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
336568
Flag
UNITED KINGDOM
—
Maury page id
psix-336568

Inspections, by type

…with no type recorded7
Years with a record 5 calendar years (1989–1993)
The 11 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 33 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it1338 - Regulatory (Subpart C or D), Net Ton
2527 - Regulatory (Subpart C or D), Gross Ton
3980 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 11

11 March 1993 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 33037
22 January 1992 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 946097
13 November 1991 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 670348
12 November 1991 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 670347
28 October 1991 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 670346
25 October 1991 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 512799
25 October 1991 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 937107
3 October 1990 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 339657
3 October 1990 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 911022
1 September 1989 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 332242
1 September 1989 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1194748

Deficiency record · 5

Accommodation/Occupational Safety
Issued 25 October 1991 Resolved
PROVIDE AND INSTALL PROTECTIVE COVERS OR PERMANENTLY CLOSE THE OPENINGS ON "B" DECK, PORT AND STBD, AFT, NO LATER THAN NEXT U.S. PORT.
Condition: Unknown
Due 25 October 1991
Resolved 22 January 1992
Accommodation/Occupational Safety
Issued 25 October 1991 Resolved
MAKE PERMANENT REPAIRS TO ALL MAIN DECK (CARGO DECK AREA) LADDERS NO LATER THAN 31DEC91.
Condition: Unknown
Due 31 December 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 25 October 1991 Resolved
MAKE AVAILABLE A BALLAST TANK,DOUBLE BOTTOM,PORT AND STBD,FWD AND AFT, CERTIFIED SAFE FOR MEN BY CERTIFIED MARINE CHEMIST FOR COAST GUARD INTERNALEXAM AT NEXT U.S. PORT.
Condition: Unknown
Due 25 October 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 25 October 1991 Resolved
INSTALL METAL BLANK FLANGES AND MINIMUM FOUR (4) BOLTS EACH FOR ALL PORTABLE CARGO HOSES PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 25 October 1991
Resolved 22 January 1992
Deck/Cargo
Issued 3 October 1990 Resolved
HYDRO TEST ALL CARGO PIPING TO 1 1/2 TIMES MAWP AS REQUIRED UNDER 33 CFR 156.170.
Condition: Unknown
Due 3 October 1990
Resolved 3 October 1990

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.