Records from 2007 to 2026. Most recent: inspection, 12 August 2026.
Inspection history · 27
12 August 2026
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8463143
29 July 2026
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8449759
1 June 2026
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8385374
1 July 2025
Examination of Repairs · Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8233220
31 July 2024
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7971672
24 August 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7795779
29 August 2022
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7546470
27 July 2022
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7528259
7 January 2022
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7377964
13 October 2021
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7331805
11 October 2021
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7330553
3 September 2021
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7303269
8 June 2021
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7218593
5 January 2021
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7123092
27 October 2020
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7085648
6 October 2020
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7073383
24 August 2020
In-Service Inspection · COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7041811
11 May 2020
In-Service Inspection · Construction Oversight · Examination of Repairs · Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6957257
15 August 2019
Annual Inspection · DAPI Audit
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6789004
26 September 2018
Deficiency Check · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6548879
27 September 2017
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6276587
30 August 2017
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6255891
29 June 2017
Administrative Inspection · Drydock Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6212204
6 June 2017
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6176966
15 September 2016
Deficiency Check · In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6002586
31 August 2016
Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5989907
31 August 2016
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6000787
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 24 August 2023
Resolved
Found all three of the vessel's fire hoses to be leaking.
Action required: 10 - Deficiency Rectified
Due 24 September 2023
Resolved 25 September 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 July 2022
Resolved
child PFD count incorrect with marked container. correct marking or provide properly marked type I child size PFD.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2022
Resolved 27 July 2022
Resolution: corrected.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 27 July 2022
Resolved
WTD indicator in pilothouse inop.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2022
Resolved 8 August 2022
Resolution: corrected.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 January 2022
Resolved
Vessel's sound producing device as required by 33 CFR 83.33 is inoperable. Provide proof of proper operation for all anticipated weather conditions to the satisfaction of the OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2022
Resolved 27 July 2022
Resolution: witnessed proper operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 October 2021
Resolved
A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds. The ram in-fitting to the knuckle of the port rudder disconnected.
Action required: 10 - Deficiency Rectified
Resolved 11 October 2021
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 3 September 2021
Resolved
A vessel must operate in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Vessel experienced an issue with the hydraulic pump associated with the loading ramp on the vessel. Mechanics identified the issue was a faulty diverter valve. Affect permanent repairs to the satisfaction of Coast Guard marine inspector. (46 CFR 185.100 and 46 CFR 185.335)
Action required: 705 - Other - as specified
Resolved 3 September 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 October 2020
Resolved
Determine cause, complete repairs and demonstrate proper operation of main propulsion actuators/controls.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 October 2020
Resolved 27 October 2020
Resolution: Tech rep attended vessel, determined cause, removed & replaced shorted actuator.
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 5 October 2020
Resolved
Provide proof of recent crew training and underway drills.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2020
Resolved 5 January 2021
Resolution: Received photo documentation of proper drills having been conducted within recent months.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 September 2018
Resolved
Tighten tiller arm on port rudder stock and demonstrate proper operation of same before 26OCT2018 to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2018
Resolved 25 October 2018
Resolution: corrected
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 September 2018
Resolved
Replace wasted bilge suction strainers in various spaces before 26OCT2018 to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2018
Resolved 25 October 2018
Resolution: corrected
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 26 September 2018
Resolved
Port and starboard fuel oil tank vents have no flame screens. Provide vent fittings with removable flame screens before 26OCT2018 to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2018
Resolved 25 October 2018
Resolution: corrected
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 26 September 2018
Resolved
Bilge alarms at operating station do not indicate which space is flooded. Provide durable and legible labels for bilge alarms lights indicating which space is flooded before 26OCT2018 to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2018
Resolved 25 October 2018
Resolution: corrected
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 September 2018
Resolved
Missing fuse caps on navigation lights power panel must be replaced or covered before 26OCT2018 to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2018
Resolved 25 October 2018
Resolution: corrected
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 26 September 2018
Resolved
Repair inoperable gages at operating station for RPM and lubricating oil pressure for port propulsion engine before 26OCT2018 to the satisfaction of the attending
marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2018
Resolved 25 October 2018
Resolution: corrected
Documentation › Markings/Placards › Warning Signs
Issued 30 August 2017
Resolved
Install signage required by 49 CFR 176.325.
Condition: Improper/Lack of Maintenance
Due 30 September 2017
Resolved 27 September 2017
Resolution: installed
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 30 August 2017
Resolved
Mount portable fire extinguisher properly (wrong bracket) at port aft corner of main deck.
Condition: Improper Installation
Due 30 September 2017
Resolved 27 September 2017
Resolution: mounted
Electrical › Electric Supply System (service) › Cable
Issued 30 August 2017
Resolved
Make proper repair to portside shore power cable prior to use.
Condition: Improper/Lack of Maintenance
Due 30 September 2017
Resolved 27 September 2017
Resolution: replaced
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 30 August 2017
Resolved
Make anchor light operational.
Condition: Improper/Lack of Maintenance
Due 30 September 2017
Resolved 27 September 2017
Resolution: corrected
Engineering › Fuel Oil Service System › Valve, Control
Issued 30 August 2017
Resolved
Label remote fuel oil shut off valve.
Condition: Improper/Lack of Maintenance
Due 30 September 2017
Resolved 27 September 2017
Resolution: labeled
Engineering › Bilge Water Management System › Manifold
Issued 30 August 2017
Resolved
Label bilge manifold suction valves.
Condition: Improper/Lack of Maintenance
Due 30 September 2017
Resolved 27 September 2017
Resolution: labeled
Documentation › Markings/Placards › Warning Signs
Issued 30 August 2017
Resolved
Label emergency escape from engineroom.
Condition: Improper/Lack of Maintenance
Due 30 September 2017
Resolved 27 September 2017
Resolution: labeled
Electrical › Electric Generation Source (service) › Generator
Issued 30 August 2017
Resolved
Provide labels for derating both ship service generators for 50degF service.
Condition: Improper Installation
Due 30 September 2017
Resolved 27 September 2017
Resolution: labeled
Engineering › Fuel Oil Service System › Filter
Issued 30 August 2017
Resolved
Install metallic plugs o the sediment drain cocks in fuel filters at portside of engineroom.
Condition: Improper Installation
Due 30 September 2017
Resolved 27 September 2017
Resolution: installed
Fire Fighting › Fire Pumps › Arrangement
Issued 30 August 2017
Resolved
Replace chafed flexible connections in fire pump suction and discharge piping.
Condition: Improper/Lack of Maintenance
Due 30 September 2017
Resolved 27 September 2017
Resolution: replaced
Construction/Loadline › Hull › Hull Plating
Issued 29 June 2017
Resolved
Hull and bulkhead plating wasted/holed between engineroom and shaft alley, starboard side from chine to stbd shaft doubler. Corrected during inspection.
Condition: Improper/Lack of Maintenance
Due 6 July 2017
Resolved 6 July 2017
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 16 September 2016
Resolved
Discovered fuel leak on aft generator flexible piping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 September 2016
Resolved 23 September 2016
Resolution: installed satisfactory hoses.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 16 September 2016
Resolved
discovered multiple cracked and excessively dry-rotted flexible fuel lines.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 September 2016
Resolved 23 September 2016
Resolution: installed new hoses.
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 16 September 2016
Resolved
inspect and replace all engine room flexible oil lines as needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 September 2016
Resolved 23 September 2016
Resolution: installed new hoses.
Operations/Management › Drills/Instruction › Not Conducted
Issued 1 September 2016
Resolved
Provide records of man overboard, fire, and abandon ship drills.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2016
Resolved 16 September 2016
Resolution: Satisfactory records of drills were provided
Operations/Management › Drills/Instruction › Not Conducted
Issued 1 September 2016
Resolved
Provide records of conducting training as to the duties crew members are expected to perform in an emergency.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 September 2016
Resolved 2 September 2016
Resolution: Satisfactory records of drills were provided
Fire Fighting › Fire Main › Condition
Issued 31 August 2016
Resolved
Repair firemain and have reinspection by OCMI.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 September 2016
Resolved 2 September 2016
Resolution: Witnessed satisfactory repairs.
Fire Fighting › Fire Main › Condition
Issued 31 August 2016
Resolved
Fire main split in two locations. Repair fire main and have reinspection by marine inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 September 2016
Resolved 2 September 2016
Resolution: witnessed satisfactory repairs.
Engineering › Fuel Oil Service System › Filter
Issued 31 August 2016
Resolved
Install flame bowl on stbd Raycor filter
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 September 2016
Resolved 23 September 2016
Resolution: flame screen installed.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 31 August 2016
Resolved
Install heat shields on exhaust elbows of both mains
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 September 2016
Resolved 16 September 2016
Resolution: witnessed proper installation.
Navigation › Piloting/Steering › US Coast Pilot
Issued 31 August 2016
Resolved
Obtain corrected light list, Coast Pilot and charts for the area transited
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 September 2016
Resolved 23 September 2016
Resolution: corrected publications on board.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 31 August 2016
Resolved
Replace plastic trash can in pax cabin with metal one
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 September 2016
Resolved 16 September 2016
Resolution: Trash can replaced with metal.
Construction/Loadline › Penetrations › Gasket
Issued 31 August 2016
Resolved
Replace seal on collision bulkhead hatch cover
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2016
Resolved 16 September 2016
Resolution: inspected satisfactorily.
Construction/Loadline › Hull › Bottom Plating
Issued 31 August 2016
Resolved
Remove heavy scale and paint portside shaft log box as a temporary measure until next dry dock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2016
Resolved 23 September 2016
Resolution: Scale removed and preservative coatings applied.
Construction/Loadline › Hull › Bottom Plating
Issued 31 August 2016
Resolved
Same as number 7. Permanent fix at drydock gauge material and submit to ocmi repair plan for port side shaft log
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 June 2017
Resolved 17 July 2017