Records from 1984 to 1994. Most recent: inspection, 28 February 1994.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 21
28 February 1994
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 364881
27 February 1994
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 160607
24 February 1994
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 364731
24 February 1994
Tank Vessel Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1391964
29 September 1993
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1134016
10 January 1993
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 830269
21 April 1992
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 350197
14 December 1991
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1258867
31 March 1991
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 473805
18 November 1990
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 340389
18 November 1990
Certificate of Compliance
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1296094
23 September 1989
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1024655
2 March 1987
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 314648
2 March 1987
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1312337
9 January 1987
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1312423
8 January 1987
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 313622
8 January 1987
Certificate of Compliance
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1008297
8 March 1986
Damage Survey
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 997743
14 November 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 514670
15 May 1985
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 302136
27 September 1984
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 528329
Navigation
Issued 10 January 1993
Resolved
INSTALL AND PROVE PROPER OPERATION OF STEERING GEAR HYDRAULIC FLUID RESERVOIR LOW LEVEL ALARM ON VESSEL'S NAVIGATION BRIDGE PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 10 January 1993
Resolved 10 January 1993
Fire Fighting
Issued 10 January 1993
Resolved
INSTALL FIXED FIREFIGHTING SYSTEM IN VESSEL'S PAINT LOCKER PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 10 January 1993
Resolved 10 January 1993
Accommodation/Occupational Safety
Issued 10 January 1993
Resolved
PROVIDE APPROVAL AND TYPE CERTIFICATION FOR VESSEL'S MARINE SANITATION DEVICE AT NEXT U.S. PORT.
Condition: Unknown
Due 10 January 1993
Resolved 10 January 1993
Lifesaving
Issued 18 November 1990
Resolved
VESSELS SELF IGNITING LIGHTS FOR LIFEBUOYS WERE FOUND TO BE INOPERABLE THISIS A VIOLATION OF SOLAS 74' CH III PARTB REG 7.1.3
Condition: Unknown
Due 18 November 1990
Resolved 18 November 1990
Documentation
Issued 18 November 1990
Resolved
VESSELS OIL TRANSFER PROCEDURES DID NOT CONTAIN ALL THE INFORMATION REQUIRED BY 33 CFR155.750.
Condition: Unknown
Due 18 November 1990
Resolved 18 November 1990
Documentation
Issued 18 November 1990
Resolved
VESSELS OIL RECORD BOOK DID NOT CONTAIN AMMOUNT DISCHARGED OVERBOARD AS REQUIRED BY 33CFR151/25(d).
Condition: Unknown
Due 18 November 1990
Resolved 18 November 1990
Navigation
Issued 18 November 1990
Resolved
VESSELS N.O.S. CHART 18751 WAS NOT CORRECTED TO DATE AS REQUIED BY 33CFR164.33(a)(1)(ii).
Condition: Unknown
Due 18 November 1990
Resolved 18 November 1990
Navigation
Issued 18 November 1990
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 18 November 1990
Resolved 18 November 1990
Navigation
Issued 18 November 1990
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 18 November 1990
Resolved 18 November 1990
Navigation
Issued 8 January 1987
Resolved
33 CFR 164.33(A)(3)(II) THE VESSEL DID NOT HAVE ON BOARD A CURRENT EDITIONOF, OR APPLICABLE CURRENTLY CORRECTED EXTRACT FROM, HE TIDAL CURRENT TABLESFOR THE AREA TRANSITED(BOSTON HARBOR AND APPROACHES).
Condition: Unknown
Due 8 January 1987
Resolved 8 January 1987
Unknown
Issued 8 January 1987
Resolved
OILY WATER SEPARATOR DISCHARGE MONITOR OOC
Condition: Unknown
Due 8 January 1987
Resolved 8 January 1987
Deck/Cargo
Issued 8 January 1987
Resolved
DECK WATER SEAL LOW LEVEL ALARM OOC
Condition: Unknown
Due 8 January 1987
Resolved 8 January 1987
Deck/Cargo
Issued 8 January 1987
Resolved
NO INK AVAILABLE FOR IGS DECK PRESSURE RECORDER AND % O2 LEVEL RECORDER.
Condition: Unknown
Due 8 January 1987
Resolved 8 January 1987
Deck/Cargo
Issued 8 January 1987
Resolved
IG DECK LOW PRESSURE ALARM OOC
Condition: Unknown
Due 8 January 1987
Resolved 8 January 1987
Deck/Cargo
Issued 8 January 1987
Resolved
NO SPAN GAS ONBOARD TO SPAN O2 CONTENT METER IGS
Condition: Unknown
Due 8 January 1987
Resolved 8 January 1987