MAURY USCG vessel records
← All vessels

DIVE BARGE

DIVE BARGE is a 2000 passenger vessel (inspected). The Coast Guard has recorded 5 inspections since 2016, most recently in October 2020, along with 37 deficiencies and 3 casualty investigations between 2011 and 2015.

Records from 2011 to 2020. Most recent: inspection, 26 October 2020.

Built
2000
Last inspected
26 October 2020
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 26 October 2020
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2016–2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDG2984
337061
Flag
UNITED STATES
Maury page id
psix-337061

Documentation record

Tonnage as PSIX records it3 - Regulatory (Subpart C or D), Gross Ton
2 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

26 October 2020 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7084715
16 November 2017 Drydock Exam · Examination of Repairs · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6308386
6 February 2017 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6083487
1 November 2016 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6033301
16 February 2016 Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5804737

Deficiency record · 37

Construction/Loadline › Hull › Transverse Frame
Issued 16 November 2017 Resolved
Crop and renew wood rot at port and starboard forward crossbeam support.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2017
Resolved 24 November 2017
Resolution: Crossbeam supports cropped and renewed.
Construction/Loadline › Hull › Hull Plating
Issued 16 November 2017 Resolved
Crop and renew wood rot in starboard #4-6 hull compartment in way of overhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2017
Resolved 20 November 2017
Resolution: Wasted area cropped and renewed.
Construction/Loadline › Hull › Bracket
Issued 16 November 2017 Resolved
Replace wasted bracket in way of center pontoon portside.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2017
Resolved 20 November 2017
Resolution: Wasted brackets replaced.
Construction/Loadline › Hull › Transverse Frame
Issued 16 November 2017 Resolved
Replace wasted support beam and sister between port and center pontoon.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2017
Resolved 20 November 2017
Resolution: Wasted wood frame replaced and sistered to good wood.
Construction/Loadline › Hull › Hull Plating
Issued 16 November 2017 Resolved
Renew wasted deck plywood under center pontoon port side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2017
Resolved 20 November 2017
Resolution: Decking renewed.
Construction/Loadline › Hull › Hull Plating
Issued 16 November 2017 Resolved
Properly repair holes found in port and center pontoons ID'd my attending MI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2017
Resolved 20 November 2017
Resolution: All ID'd holed areas repaired following an approved fiberglass repair method.
Construction/Loadline › Hull › Transverse Frame
Issued 16 November 2017 Resolved
Sister wood frames ID'd as #8 and #9 deficiencies located between port and center pontoons.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2017
Resolved 20 November 2017
Resolution: Frames renewed and sistered to good wood.
Construction/Loadline › Hull › Hull Plating
Issued 16 November 2017 Resolved
Crop and renew wood rot ID'd as #11 located inboard forward starboard pontoon.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2017
Resolved 20 November 2017
Resolution: Wood rot replaced with marine grade plywood and properly installed.
Construction/Loadline › Hull › Hull Plating
Issued 16 November 2017 Resolved
Renew wasted fiberglass ID'd as #12 located on port center pontoon.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2017
Resolved 20 November 2017
Resolution: Wasted fiberglass cropped out and renewed following an approved repair method.
Engineering › Bilge Water Management System › Pump
Issued 16 November 2017 Resolved
Properly mount/secure all bilge pumps.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 December 2017
Resolved 20 November 2017
Resolution: All bilge pumps properly mounted in the bilge spaces.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 18 April 2017 Resolved
Vessel is over 5 NT; document vessel appropriately with NVDC.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 6 June 2017
Resolution: Vessel owner emailed with items he needed to complete before COD was valid. Verified he had received COD through MISLE.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 11 April 2017 Resolved
Portable fire extinguisher bottle next to operating station is corroded. Replace fire extinguisher in kind IAW 46 CFR 147.65.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 23 June 2017
Resolution: Vessel rep emailed picture of new fire extinguisher at operating station.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 11 April 2017 Resolved
Provide a lock for seawge holding tank overboard valve IAW 33 CFR 159.7
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 25 May 2017
Resolution: Received picture of sewage holding tank overboard lock.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 11 April 2017 Resolved
Adult lifejacket stowage is unmarked. Provide stowage markings for adult lifejackets IAW 46 CFR 185.604.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 12 April 2017
Resolution: Stowage markings for adult lifejackets provided.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 11 April 2017 Resolved
Renew identified 03 adult and 02 child lifejackets. Persons allowed reduced to 41 adults and 3 children until lifejackets are replaced. 46 CFR 180.71.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 12 April 2017
Resolution: Lifejackets replaced.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 April 2017 Resolved
Lanyard for waterlight was approx 2 feet. Provide a 3 foot minimum lanyard for ring life buoy waterlight. 46 CFR 180.70
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 25 May 2017
Resolution: Received picture of waterlight lanyard attached to life ring.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 April 2017 Resolved
Masthead light currently inoperable. Renew masthead light IAW 46 CFR 183.420
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 12 April 2017
Resolution: Tested masthead light satsifactory.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 11 April 2017 Resolved
CG Light List and Coast Pilot not onboard. Provide current Coast Pilot and Light List for Hawaiian Islands.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 22 June 2017
Resolution: Picture provided of updated Coast Pilot. Light list was downloaded on vessel operator's phone (HQPolLtr 10_05: Electronic Nav Publications)
Navigation › Piloting/Steering › Marine Charts
Issued 11 April 2017 Resolved
Provide up to date navigational chart for operating area. 46 CFR 184.420
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 22 June 2017
Resolution: Picture of updated chart provided.
Engineering › Bilge Water Management System › Interface Detector
Issued 11 April 2017 Resolved
Stbd aft compartment high level bilge alarm inoperable. Renew float switch. 46 CFR 182.530. Vessel master is to perform a visual inspection of stbd aft space every 30 minutes while bilge high level alarm is inoperable.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 25 May 2017
Resolution: Received picture of remounted bilge pump
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 6 February 2017 Resolved
Vessel's state registration is expired. Vessel required to provide valid state registration or COD.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2017
Resolved 14 February 2017
Resolution: Vessel explained Catch-22 with State of Hawaii. State issued a valid registration.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 6 February 2017 Resolved
Remeasure vessel to determine compliance with documentation requirements. Cite: MSC ltr 16717/P004710 dated 02 Mar 2017
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 May 2017
Resolved 12 April 2017
Resolution: Assisted vessel rep in remeasuring vessel.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 16 February 2016 Resolved
Replace retroreflective tape on 10 adult lifejackets to ensure minimum of 300 cm^2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 16 February 2016
Resolution: Life jackets taken off vessel. Adequate number of life jackets were located onboard to keep passenger count
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 16 February 2016 Resolved
Dispose of (5) non-compliant child-sized life jackets. Vessel is restricted to (4) persons under 90 pounds.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 16 March 2016
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 16 February 2016 Resolved
Replace lifering grab line and retroreflective tape
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 16 March 2016
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 16 February 2016 Resolved
Replace corrosion-resistant clip on floating waterlight.
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 16 March 2016
Documentation › Certificates/Documents › Stability Letter
Issued 16 February 2016 Resolved
Post stability letter under transparent glass so that letter is readable
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 16 March 2016
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 16 February 2016 Resolved
Label stowage of life jackets
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 16 March 2016
Operations/Management › Equipment Service/Testing › EPIRB
Issued 16 February 2016 Resolved
Vessel is restricted to a Lakes, Bays, Sounds route until appropriate lifesaving or an EPIRB is provided
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 2 May 2016
Resolution: vessel elected not to install EPIRB and keep within 1NM of shore
Engineering › Fuel Oil Storage/Transfer System › Portable Fuel System
Issued 16 February 2016 Resolved
Provide portable fuel tank to meet requirements of ABYC H-25 7 gallon limit on fuel tank
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 16 March 2016
Engineering › Fuel Oil Service System › Suction Strainer
Issued 16 February 2016 Resolved
Provide a suitable type fuel strainer with a drip pan.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 2 May 2016
Engineering › Fuel Oil Service System › Valve
Issued 16 February 2016 Resolved
Label fuel shut off valves
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 16 March 2016
Documentation › Markings/Placards › Lifejacket Placard
Issued 16 February 2016 Resolved
Provide donning instructions for all life jacket types on board.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 16 March 2016
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 16 February 2016 Resolved
Vessel will not meet Work Instruction 31 requirements for minimum manning until AED is provided onboard.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 2 May 2016
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 16 February 2016 Resolved
Clear corrosion from electrical system; ensure all connections are cleaned and tightened
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 16 March 2016
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 16 February 2016 Resolved
During electrical inspection, noted dead end wires that indicated installation of second batter. Provide a copy of an approved electrical plan, or submit a one-line diagram for review and approval. Any new installations will be required to meet new subchapter T, including the labeling of circuits.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 16 March 2016
Engineering › Fuel Oil Storage/Transfer System › Portable Fuel System
Issued 16 February 2016 Resolved
During review of vessel plans, noted fuel tank installation has been moved from platform on aft of vessel to forward of engine. Install fuel tank as per original approved drawings.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 16 March 2016

Casualty record · 3

11 March 2011Routine · role: Involved in a Marine Casualty · activity 3962507
18 March 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4819084
14 March 2015Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 5095486
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.