DIVE BARGE

DIVE BARGE is a 2000 passenger vessel (inspected). The Coast Guard has recorded 59 inspections since 1989, most recently in October 2020, along with 131 deficiencies and 3 casualty investigations between 2011 and 2015.

Records from 1989 to 2020. Most recent: inspection, 26 October 2020.

Built
2000
Last inspected
26 October 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG2984
337061
Flag
UNITED STATES
—
Maury page id
psix-337061

Inspections, by type

…with no type recorded11
Years with a record 29 calendar years (1989–2020)
The 59 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it3 - Regulatory (Subpart C or D), Gross Ton
2 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 59

26 October 2020 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7084715
16 November 2017 Drydock Exam · Examination of Repairs · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6308386
6 February 2017 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6083487
1 November 2016 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6033301
16 February 2016 Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5804737
21 October 2015 In-Service Inspection · Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5741959
3 August 2015 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5205908
18 March 2014 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4819084
3 May 2012 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4301557
24 January 2012 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4230759
22 February 2011 DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3949948
13 January 2011 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3926036
1 September 2010 Hull Examination · In-Service Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3847269
18 February 2010 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3682104
12 March 2009 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3432407
29 November 2008 Type not recorded
No type recorded · USCGC GALVESTON ISLAND (WPB 1349) · USCG Oceania District (CGD-O) · Activity 3384324
15 February 2008 Hull Examination · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3146420
22 February 2007 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2875946
11 August 2006 Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2744343
23 February 2006 COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2588648
21 March 2005 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2315874
11 March 2005 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2307393
4 March 2005 Examination of Repairs · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2299342
13 July 2004 Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2125111
8 March 2004 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2020439
27 February 2004 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2014442
15 April 2003 Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1774445
27 February 2003 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1749424
21 February 2003 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1747682
22 February 2002 Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1487474
6 March 2001 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1060416
27 February 2001 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1366210
23 February 2001 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1391501
28 February 2000 Hull Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1415318
22 February 1999 Hull Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1390945
23 February 1998 MARPOL Annex V Examination · Hull Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1414939
13 February 1997 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 208292
13 February 1997 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 754609
22 October 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1160113
12 September 1996 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1265742
31 July 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1451089
22 July 1996 Hull Examination · MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1422719
26 February 1996 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1367670
23 February 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1359049
16 February 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1454299
24 July 1995 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1421003
7 June 1995 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 379222
31 January 1995 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1353690
22 July 1994 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1354827
23 June 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 216238
23 June 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1389845
30 July 1993 Re-Inspection · Hull Examination · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1448447
21 August 1992 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 961841
24 July 1992 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 955750
28 January 1992 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 963019
17 May 1991 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1225737
22 August 1990 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1237539
26 July 1990 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1237223
26 July 1989 Plan Review "T" Boat · COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1043772

Deficiency record · 131

Construction/Loadline › Hull › Transverse Frame
Issued 16 November 2017 Resolved
Crop and renew wood rot at port and starboard forward crossbeam support.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2017
Resolved 24 November 2017
Resolution: Crossbeam supports cropped and renewed.
Construction/Loadline › Hull › Hull Plating
Issued 16 November 2017 Resolved
Crop and renew wood rot in starboard #4-6 hull compartment in way of overhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2017
Resolved 20 November 2017
Resolution: Wasted area cropped and renewed.
Construction/Loadline › Hull › Bracket
Issued 16 November 2017 Resolved
Replace wasted bracket in way of center pontoon portside.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2017
Resolved 20 November 2017
Resolution: Wasted brackets replaced.
Construction/Loadline › Hull › Transverse Frame
Issued 16 November 2017 Resolved
Replace wasted support beam and sister between port and center pontoon.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2017
Resolved 20 November 2017
Resolution: Wasted wood frame replaced and sistered to good wood.
Construction/Loadline › Hull › Hull Plating
Issued 16 November 2017 Resolved
Renew wasted deck plywood under center pontoon port side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2017
Resolved 20 November 2017
Resolution: Decking renewed.
Construction/Loadline › Hull › Hull Plating
Issued 16 November 2017 Resolved
Properly repair holes found in port and center pontoons ID'd my attending MI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2017
Resolved 20 November 2017
Resolution: All ID'd holed areas repaired following an approved fiberglass repair method.
Construction/Loadline › Hull › Transverse Frame
Issued 16 November 2017 Resolved
Sister wood frames ID'd as #8 and #9 deficiencies located between port and center pontoons.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2017
Resolved 20 November 2017
Resolution: Frames renewed and sistered to good wood.
Construction/Loadline › Hull › Hull Plating
Issued 16 November 2017 Resolved
Crop and renew wood rot ID'd as #11 located inboard forward starboard pontoon.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2017
Resolved 20 November 2017
Resolution: Wood rot replaced with marine grade plywood and properly installed.
Construction/Loadline › Hull › Hull Plating
Issued 16 November 2017 Resolved
Renew wasted fiberglass ID'd as #12 located on port center pontoon.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2017
Resolved 20 November 2017
Resolution: Wasted fiberglass cropped out and renewed following an approved repair method.
Engineering › Bilge Water Management System › Pump
Issued 16 November 2017 Resolved
Properly mount/secure all bilge pumps.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 December 2017
Resolved 20 November 2017
Resolution: All bilge pumps properly mounted in the bilge spaces.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 18 April 2017 Resolved
Vessel is over 5 NT; document vessel appropriately with NVDC.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 6 June 2017
Resolution: Vessel owner emailed with items he needed to complete before COD was valid. Verified he had received COD through MISLE.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 11 April 2017 Resolved
Portable fire extinguisher bottle next to operating station is corroded. Replace fire extinguisher in kind IAW 46 CFR 147.65.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 23 June 2017
Resolution: Vessel rep emailed picture of new fire extinguisher at operating station.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 11 April 2017 Resolved
Provide a lock for seawge holding tank overboard valve IAW 33 CFR 159.7
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 25 May 2017
Resolution: Received picture of sewage holding tank overboard lock.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 11 April 2017 Resolved
Adult lifejacket stowage is unmarked. Provide stowage markings for adult lifejackets IAW 46 CFR 185.604.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 12 April 2017
Resolution: Stowage markings for adult lifejackets provided.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 11 April 2017 Resolved
Renew identified 03 adult and 02 child lifejackets. Persons allowed reduced to 41 adults and 3 children until lifejackets are replaced. 46 CFR 180.71.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 12 April 2017
Resolution: Lifejackets replaced.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 April 2017 Resolved
Lanyard for waterlight was approx 2 feet. Provide a 3 foot minimum lanyard for ring life buoy waterlight. 46 CFR 180.70
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 25 May 2017
Resolution: Received picture of waterlight lanyard attached to life ring.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 April 2017 Resolved
Masthead light currently inoperable. Renew masthead light IAW 46 CFR 183.420
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 12 April 2017
Resolution: Tested masthead light satsifactory.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 11 April 2017 Resolved
CG Light List and Coast Pilot not onboard. Provide current Coast Pilot and Light List for Hawaiian Islands.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 22 June 2017
Resolution: Picture provided of updated Coast Pilot. Light list was downloaded on vessel operator's phone (HQPolLtr 10_05: Electronic Nav Publications)
Navigation › Piloting/Steering › Marine Charts
Issued 11 April 2017 Resolved
Provide up to date navigational chart for operating area. 46 CFR 184.420
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 22 June 2017
Resolution: Picture of updated chart provided.
Engineering › Bilge Water Management System › Interface Detector
Issued 11 April 2017 Resolved
Stbd aft compartment high level bilge alarm inoperable. Renew float switch. 46 CFR 182.530. Vessel master is to perform a visual inspection of stbd aft space every 30 minutes while bilge high level alarm is inoperable.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 25 May 2017
Resolution: Received picture of remounted bilge pump
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 6 February 2017 Resolved
Vessel's state registration is expired. Vessel required to provide valid state registration or COD.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2017
Resolved 14 February 2017
Resolution: Vessel explained Catch-22 with State of Hawaii. State issued a valid registration.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 6 February 2017 Resolved
Remeasure vessel to determine compliance with documentation requirements. Cite: MSC ltr 16717/P004710 dated 02 Mar 2017
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 May 2017
Resolved 12 April 2017
Resolution: Assisted vessel rep in remeasuring vessel.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 16 February 2016 Resolved
Replace retroreflective tape on 10 adult lifejackets to ensure minimum of 300 cm^2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 16 February 2016
Resolution: Life jackets taken off vessel. Adequate number of life jackets were located onboard to keep passenger count
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 16 February 2016 Resolved
Dispose of (5) non-compliant child-sized life jackets. Vessel is restricted to (4) persons under 90 pounds.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 16 March 2016
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 16 February 2016 Resolved
Replace lifering grab line and retroreflective tape
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 16 March 2016
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 16 February 2016 Resolved
Replace corrosion-resistant clip on floating waterlight.
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 16 March 2016
Documentation › Certificates/Documents › Stability Letter
Issued 16 February 2016 Resolved
Post stability letter under transparent glass so that letter is readable
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 16 March 2016
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 16 February 2016 Resolved
Label stowage of life jackets
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 16 March 2016
Operations/Management › Equipment Service/Testing › EPIRB
Issued 16 February 2016 Resolved
Vessel is restricted to a Lakes, Bays, Sounds route until appropriate lifesaving or an EPIRB is provided
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 2 May 2016
Resolution: vessel elected not to install EPIRB and keep within 1NM of shore
Engineering › Fuel Oil Storage/Transfer System › Portable Fuel System
Issued 16 February 2016 Resolved
Provide portable fuel tank to meet requirements of ABYC H-25 7 gallon limit on fuel tank
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 16 March 2016
Engineering › Fuel Oil Service System › Suction Strainer
Issued 16 February 2016 Resolved
Provide a suitable type fuel strainer with a drip pan.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 2 May 2016
Engineering › Fuel Oil Service System › Valve
Issued 16 February 2016 Resolved
Label fuel shut off valves
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 16 March 2016
Documentation › Markings/Placards › Lifejacket Placard
Issued 16 February 2016 Resolved
Provide donning instructions for all life jacket types on board.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 16 March 2016
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 16 February 2016 Resolved
Vessel will not meet Work Instruction 31 requirements for minimum manning until AED is provided onboard.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 2 May 2016
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 16 February 2016 Resolved
Clear corrosion from electrical system; ensure all connections are cleaned and tightened
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 16 March 2016
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 16 February 2016 Resolved
During electrical inspection, noted dead end wires that indicated installation of second batter. Provide a copy of an approved electrical plan, or submit a one-line diagram for review and approval. Any new installations will be required to meet new subchapter T, including the labeling of circuits.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 16 March 2016
Engineering › Fuel Oil Storage/Transfer System › Portable Fuel System
Issued 16 February 2016 Resolved
During review of vessel plans, noted fuel tank installation has been moved from platform on aft of vessel to forward of engine. Install fuel tank as per original approved drawings.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 16 March 2016
Deck/Cargo › Holds/Tanks › Hatch
Issued 21 October 2015 Resolved
Repair or replace port fwd hatch to prevent water intrustion into port voids. Repair or replace forward center hatch.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 November 2015
Resolution: Forward port hatch gaskets replaced and new lid. Center pontoon hatch replaced as new.
Engineering › Bilge Water Management System › Valve
Issued 22 February 2011 Resolved
Vessel must install postive action valves at through hulls for bilge pump system.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 23 March 2011
Resolved 18 March 2011
Resolution: Installed positive action valves at all through hulls.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 February 2011 Resolved
Vessel must provide current electrical plans with load calculations for CG approval
Due 30 March 2011
Resolved 1 April 2011
Lifesaving › Lifebuoys › Serviceable
Issued 30 September 2010 Resolved
Renew retro tape on ring buoy.
Action required: 705 - Other - as specified
Due 15 October 2010
Resolved 3 November 2010
Engineering › Bilge Water Management System › Not Operational
Issued 30 September 2010 Resolved
Add/increase size of limberholes in ring frames to improve drainage. Submit plans prior to repairs.
Action required: 705 - Other - as specified
Due 15 October 2010
Resolved 3 November 2010
Resolution: Plans were not submitted prior to repairs. Required plans for documentation purposes only.
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 30 September 2010 Resolved
Tighten/raise lifelines.
Action required: 705 - Other - as specified
Due 15 October 2010
Resolved 3 November 2010
Construction/Loadline › Structures › Manhole
Issued 30 September 2010 Resolved
Submit plans and make repairs to make center hull forward hatch watertight.
Action required: 705 - Other - as specified
Due 15 October 2010
Resolved 3 November 2010
Resolution: Plans were not submitted, 5200 was used to prevent water ingress into hatch. Plans will still be required for documentation purposes.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 30 September 2010 Resolved
Provide ring buoy light. Vessel is restricted to daylight ops until light is provided.
Action required: 705 - Other - as specified
Due 15 October 2010
Resolved 3 November 2010
Construction/Loadline › Hull › Hull Plating
Issued 15 September 2010 Resolved
Crop and renew port hull outboard aft quarter IVO previous small repair above the waterline. Submit plan for USCG approval prior to conducting repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2010
Resolution: Repairs were made IAW previous approved repair proposal for other crop/renew. Plywood was cropped (4 ft by 32") in 3rd space forward from stern (port hull outboard).
Construction/Loadline › Hull › Hull Plating
Issued 9 September 2010 Resolved
Renew center hull bow repair. Ensure proper fitup and no stainless steel fasteners are used within 6 inches of waterline or lower. Make available for inspection by USCG after repair is made.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 September 2010
Construction/Loadline › Structures › End Bulkhead
Issued 4 September 2010 Resolved
Provide means of filling voids in collision bulkheads to make them watertight.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 September 2010
Construction/Loadline › Structures › Transverse Bulkhead
Issued 4 September 2010 Resolved
In #2 void port hull, renew upper ring frame and grind glassed area for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 September 2010
Construction/Loadline › Hull › Stiffener
Issued 4 September 2010 Resolved
In #3 void port hull renew middle inboard rotted stringer.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 September 2010
Construction/Loadline › Hull › Bottom Plating
Issued 4 September 2010 Resolved
Renew hull plate starboard hull lazarette stern and outboard. Investigate void inboard further.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 September 2010
Resolution: Lazarette plating was replaced stern/outboard. Inboard was a void which was filled with epoxy resin.
Construction/Loadline › Hull › Hull Plating
Issued 4 September 2010 Resolved
Submit specifications list for all hull plate and internal keel replacement for vessel file.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 September 2010
Construction/Loadline › Structures › Deck Plating
Issued 4 September 2010 Resolved
Submit plans for deck replacement.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 September 2010
Construction/Loadline › Hull › Hull Plating
Issued 1 September 2010 Resolved
Grind all identified areas for further USCG inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 September 2010
Electrical › Electric Supply System (service) › Cable
Issued 1 September 2010 Resolved
Port hull lazarette, connect bilge pump wiring via crimped connection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 November 2010
Construction/Loadline › Hull › Hull Plating
Issued 1 September 2010 Resolved
Submit plans for USCG approval of the following repairs: a) hull/side shell replacement port hull laz outboard, center hull stbd side, center hull bow, stbd hull laz bottom;. b) center hull #2 ring frame replacement,; c) external keel removal and reglassing; d) internal keel replacement; e) deck rot; f) overhead/seating replacement.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 September 2010
Communications › Radio Communications › EPIRB
Issued 12 March 2009 Resolved
Prove non-expiration of or replace EPIRB battery.
Due 18 March 2009
Resolved 27 March 2009
Resolution: Vessel granted permission to remove EPRIB from COI.
Communications › Radio Communications › EPIRB
Issued 12 March 2009 Resolved
Replace EPIRB top cover.
Due 18 March 2009
Resolved 27 March 2009
Resolution: Vessel granted permission to remove EPRIB from COI.
Communications › Radio Communications › EPIRB
Issued 12 March 2009 Resolved
Replace expired hydrostatic release unit for EPIRB.
Due 18 March 2009
Resolved 27 March 2009
Resolution: Vessel granted permission to remove EPRIB from COI.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 12 March 2009 Resolved
Replace starboard running light bulb. Current bulb too dim.
Due 18 March 2009
Resolved 18 March 2009
Resolution: Correct lightbulb replaced.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 12 March 2009 Resolved
Provide (1) additional child life jacket as per your COI.
Due 18 March 2009
Resolved 18 March 2009
Resolution: (1) additional child life jacket placed onboard and labeled properly.
Engineering › Bilge Water Management System › Pump
Issued 12 March 2009 Resolved
Secure down all three bilge pumps.
Due 18 March 2009
Resolved 18 March 2009
Resolution: O/O installed plastic bracket that kept bilge pump on void deck.
Accommodation/Occupational Safety › Occupational Safety › Smoking
Issued 12 March 2009 Resolved
Obtain and post "No Smoking" signs in the vicinity of fuel tank.
Due 18 March 2009
Resolved 18 March 2009
Resolution: Warning permanently marked using marker.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 12 March 2009 Resolved
Replace plastic junction box with marine-grade type located above B-1 fire extinguisher.
Due 18 March 2009
Resolved 18 March 2009
Resolution: Metal junction box installed.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 12 March 2009 Resolved
Provide fuel shut-off valves for portable fuel tank.
Due 18 March 2009
Resolved 18 March 2009
Resolution: Replaced hose and connection from fuel tank to include quick-release as method for fuel shut-off.
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 March 2009 Resolved
Properly secure loose wires around vessel, especially near the console area.
Due 18 March 2009
Resolved 18 March 2009
Resolution: Wires cleaned up. Needed wires bound and secured using a combination of plastic and metal wire ties. Unneeded wires removed.
Communications › Alarms/Indicators › High Water Alarm
Issued 12 March 2009 Resolved
Prove proper operation of starboard and center high water alarm. Crew to make 30-min rounds of pontoons prior to repair. Log all rounds into daily logs.
Due 18 March 2009
Resolved 18 March 2009
Resolution: High water alarms repaired and proven operational.
Operations/Management › Drills/Instruction › Fire
Issued 12 March 2009 Resolved
Conduct fire and man overboard drills witnessed by CG marine inspector.
Due 18 March 2009
Resolved 18 March 2009
Resolution: Drills completed. All sat but not great.
Construction/Loadline › Hull › Keel
Issued 15 February 2008 Resolved
Make repairs to fiberglass matting in indicated sections of the vessel's hull.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 February 2008
Resolved 19 February 2008
Resolution: Satisfactory repairs made to the vessel
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 15 February 2008 Resolved
Make repairs to passenger seating areas throughout the vessel
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 February 2008
Resolved 19 February 2008
Construction/Loadline › Hull › Keel
Issued 15 February 2008 Resolved
Make repairs to lap joints aft
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 February 2008
Resolved 19 February 2008
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 15 February 2008 Resolved
Make repairs to all areas of the deck accessible to passengers
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 February 2008
Resolved 19 February 2008
Construction/Loadline › Hull › Longitudinal Frame
Issued 15 February 2008 Resolved
Renew dryrot in the athwartships longitudnals
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 February 2008
Resolved 19 February 2008
Construction/Loadline › Hull › Hull Plating
Issued 15 February 2008 Resolved
Make indicated areas of the vessel's hull available for inspection.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 February 2008
Resolved 19 February 2008
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 15 February 2008 Resolved
Provide MIS submission IAW 46CFR16.400
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 February 2008
Resolved 20 February 2008
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 15 February 2008 Resolved
Provide 4 new lifejackets with retroreflective material prior to the carriage of passengers
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 February 2008
Resolved 20 February 2008
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 15 February 2008 Resolved
Provide proof of FCC Radio Operators permit
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 February 2008
Resolved 20 February 2008
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 8 March 2007 Resolved
Provide evidence of 1 hour EAP Supervisor Training IAW 46CFR16.401
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 April 2007
Resolved 11 April 2007
Resolution: Prooof of training provided IAW 46CFR16.401
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 8 March 2007 Resolved
Submit copy of 2006 MIS Report IAW 46CFR16.500
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 April 2007
Resolved 10 April 2007
Resolution: MIS submitted IAW 46CFR16.500
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 8 March 2007 Resolved
Provide EAP Policy Statement and copy of hotline numbers IAW 46CFR16.401
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 April 2007
Resolved 10 April 2007
Resolution: EAP as per 46CFR16.401
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 23 February 2006 Resolved
Provide 6 Child PFD's in accordance with 46 CFR 180.
Due 9 March 2006
Resolved 2 March 2006
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 23 February 2006 Resolved
Provide a buoyant lifelline for the ring lifebuoy in accordance with 46 CFR 181.
Due 9 March 2006
Resolved 2 March 2006
Navigation › Piloting/Steering › Coast Guard Light List
Issued 23 February 2006 Resolved
Provide current U. S. Coast Pilot and Coast Guard Light List in accordance with 46 CFR 184.
Due 9 March 2006
Resolved 2 March 2006
Personnel › Training › Fire Fighting Basic
Issued 11 March 2005 Resolved
Conduct and log fire fighting, man overboard and abandon ship drills IAW 46 CFR 185.
Due 18 March 2005
Resolved 21 March 2005
Communications › Radio Communications › EPIRB
Issued 11 March 2005 Resolved
Test EPIRB monthly and log results IAW 46 CFR 180.
Due 18 March 2005
Resolved 21 March 2005
Navigation › Piloting/Steering › Magnetic Compass
Issued 11 March 2005 Resolved
Provide a light for the magnetic compass IAW 46 CFR 184.
Due 18 March 2005
Resolved 21 March 2005
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 11 March 2005 Resolved
Provide (2) additional Child PFD's IAW COI.
Due 18 March 2005
Resolved 21 March 2005
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 11 March 2005 Resolved
Fuse the VHF radio at the main panel IAW 46 CFR 183.
Due 18 March 2005
Resolved 21 March 2005
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 11 March 2005 Resolved
Renew retro-reflective tape on all PFD's IAW 46 CFR 180.
Due 18 March 2005
Resolved 21 March 2005
Operations/Management › Drills/Instruction
Issued 27 February 2003 Resolved
Conduct and log abandon ship, man overboard, and fire drills quarterly in accordance with 46 CFR 185.520 & 185.524. LEGACY COMPONENT DESC: Fire
Due 27 March 2003
Resolved 7 March 2003
Operations/Management › Equipment Service/Testing
Issued 27 February 2003 Resolved
Replace expired hydrostatic release for the EPIRB in accordance with 46 CFR 180.64. LEGACY COMPONENT DESC: EPIRB
Due 27 March 2003
Resolved 7 March 2003
Operations/Management › Equipment Service/Testing
Issued 27 February 2003 Resolved
Test EPIRB monthly & log results in accordance with 46 CFR 185.728. LEGACY COMPONENT DESC: EPIRB
Due 27 March 2003
Resolved 7 March 2003
Lifesaving
Issued 27 February 2001 Resolved
Replace ring lifebuoy in accordance with 46 CFR 180.70.
Condition: Unknown
Due 6 March 2001
Resolved 6 March 2001
Navigation
Issued 27 February 2001 Resolved
Provide NAV RULES, Coast Pilot, and Coast Guard Light List in accordance_x001C_ with 46 CFR 184.420.
Condition: Unknown
Due 6 March 2001
Resolved 6 March 2001
Navigation
Issued 27 February 2001 Resolved
Provide a magnetic compass in accordance with 46 CFR 184.402.
Condition: Unknown
Due 6 March 2001
Resolved 6 March 2001
Lifesaving
Issued 27 February 2001 Resolved
Replace retro-reflective material on all adult (52) life jackets in accordance with 46 CFR 185.604(h).
Condition: Unknown
Due 6 March 2001
Resolved 6 March 2001
Fire Fighting
Issued 27 February 2001 Resolved
Provide three 2.5 gallon bucKets in lieu of fire pump in accordance with 46CFR 181.601.
Condition: Unknown
Due 6 March 2001
Resolved 6 March 2001
Documentation
Issued 27 February 2001 Resolved
Provide current FCC Safety Certificate in accordance with 46 CFR 184.502.
Condition: Unknown
Due 6 March 2001
Resolved 6 March 2001
Electrical
Issued 31 July 1996 Resolved
Replace wire for power and lighting circuits with UL Boat or Marine cable in accordance with IFR 46 CFR 183.340(d).
Condition: Unknown
Due 31 July 1996
Resolved 31 July 1996
Documentation
Issued 22 July 1996 Resolved
Provide employee acknowledgments of chemical testing program for all employees and documentation of supervisor trainining in accordance with _x001C_ 46 CFR 16._x001C_
Condition: Unknown
Due 22 July 1996
Resolved 22 July 1996
Navigation
Issued 22 July 1996 Resolved
Provide navigation lights for diving operations in accordance with 72 COLREGS.
Condition: Unknown
Due 22 July 1996
Resolved 22 July 1996
Electrical
Issued 22 July 1996 Resolved
Provide emergency switch at or near the battery in accordance with 46 CFR 183.05-10(f).
Condition: Unknown
Due 22 July 1996
Resolved 22 July 1996
Lifesaving
Issued 22 July 1996 Resolved
Properly splice 60 ft line around body of ring buoy.
Condition: Unknown
Due 22 July 1996
Resolved 22 July 1996
Fire Fighting
Issued 22 July 1996 Resolved
Provide pin and wire seal for B-I portable fire extinguisher.
Condition: Unknown
Due 22 July 1996
Resolved 22 July 1996
Electrical
Issued 22 July 1996 Resolved
Remove all direct taps from battery and install distribution panel for bilge pump and float switch wiring, properly fused in accordance with IFR 46 CFR 183.
Condition: Unknown
Due 22 July 1996
Resolved 22 July 1996
Fire Fighting
Issued 22 July 1996 Resolved
Provide approved bracket for B-II portable fire extinguisher.
Condition: Unknown
Due 22 July 1996
Resolved 22 July 1996
Documentation
Issued 22 July 1996 Resolved
Provide proof of enrollment with Maritime Consortium, Inc. for Joanne Moncrief prior to operating in a covered position.
Condition: Unknown
Due 22 July 1996
Resolved 22 July 1996
Lifesaving
Issued 22 July 1996 Resolved
Provide water light with 3-6 ft lanyard for ring buoy in accordance with IFR 46 CFR 180.70(d).
Condition: Unknown
Due 22 July 1996
Resolved 22 July 1996
Documentation
Issued 22 July 1996 Resolved
Provide documentation of crew training in accordance with IFR 46 CFR 185.420.
Condition: Unknown
Due 22 July 1996
Resolved 22 July 1996
Lifesaving
Issued 22 July 1996 Resolved
Provide life jacket placards in accordance with IFR 46 CFR 185.516.
Condition: Unknown
Due 22 July 1996
Resolved 22 July 1996
Lifesaving
Issued 22 July 1996 Resolved
Provide documentation of abandon ship and man overboard drills and trainingin accordance with IFR 46 CFR 185.520.
Condition: Unknown
Due 22 July 1996
Resolved 22 July 1996
Lifesaving
Issued 22 July 1996 Resolved
Provide brightly colored, portable watertight container marked "DISTRESS SIGNALS" in accordance with IFR 46 CFR 185.614.
Condition: Unknown
Due 22 July 1996
Resolved 22 July 1996
Lifesaving
Issued 22 July 1996 Resolved
Install retroreflective tape on ring buoy in accordance with IFR 46 CFR 185.604(i).
Condition: Unknown
Due 22 July 1996
Resolved 22 July 1996
Fire Fighting
Issued 22 July 1996 Resolved
Provide documentation of fire fighting drills and training in accordance with IFR 46 CFR 185.524.
Condition: Unknown
Due 22 July 1996
Resolved 22 July 1996
Documentation
Issued 23 February 1996 Resolved
Provide pre employment negative test results for Joanne Moncrief, [name withheld] [name withheld].
Condition: Unknown
Due 23 February 1996
Resolved 23 February 1996
Lifesaving
Issued 16 February 1996 Resolved
Prior to carrying passengers for hire, renew ring buoy.
Condition: Unknown
Due 16 February 1996
Resolved 16 February 1996
Engineering
Issued 16 February 1996 Resolved
Prior to carrying passengers for hire, renew cap for the fuel tank.
Condition: Unknown
Due 16 February 1996
Resolved 16 February 1996
Engineering
Issued 16 February 1996 Resolved
Prior to carrying passengers for hire, remove plastic gas tanks.
Condition: Unknown
Due 16 February 1996
Resolved 16 February 1996
Documentation
Issued 16 February 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 16 February 1996
Resolved 16 February 1996
Navigation
Issued 24 July 1995 Resolved
REPAIR OR REPLACE VHF-FM RADIO. VESSEL RESTRICTED TO 1000 FT FROM SHORE UNTIL CORRECTED.
Condition: Unknown
Due 31 July 1995
Resolved 31 July 1995
Construction/Loadline
Issued 24 July 1995 Resolved
REPAIR GLASSWORK ON FORWARD PORT PONTOON TOP IN WAY OF ANCHOR CHAIN / MOORING LINE CHAFE AREA.
Condition: Unknown
Due 31 July 1995
Resolved 31 July 1995
Electrical
Issued 22 July 1994 Resolved
RENEW TERMINAL LUGS FOR VARIOUS CABLES ON WIRES FOR ELECTRIC BILGE PUMPS. (46 CFR 183.05-50)
Condition: Unknown
Due 7 August 1994
Resolved 9 August 1994
Electrical
Issued 22 July 1994 Resolved
REPLACE MISSING SWITCH FOR STBD ELECTRIC BILGE PUMP, NEAR OPERATORS CONSOLE. (46 CFR 183.05-50)
Condition: Unknown
Due 7 August 1994
Resolved 9 August 1994
Fire Fighting
Issued 22 July 1994 Resolved
REPLACE MISSING DISCHARGE HOSE FOR PORTABLE HAND BILGE/FIRE PUMP. (46 CFR 180.25-10)
Condition: Unknown
Due 7 August 1994
Resolved 9 August 1994
Lifesaving
Issued 22 July 1994 Resolved
REPLACE RING BUOY LINE WITH 60 FT OF POLYPROPYLENE - ORANGE IN COLOR OR OTHERWISE IMPERVIOUS TO UV LIGHT. (46 CFR 180.30)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 August 1994
Resolved 9 August 1994
Lifesaving
Issued 22 July 1994 Resolved
REPLACE (1) ORANGE SMOKE SIGNALING DEVICE. (46 CFR 180.35)
Condition: Unknown
Due 7 August 1994
Resolved 9 August 1994
Documentation
Issued 23 June 1994 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVIDE EVIDENCE OF COMPLIANCE WITH DRUG TESTING PROGRAM.
Condition: Unknown
Due 23 July 1994
Resolved 8 July 1994
Construction/Loadline
Issued 30 July 1993 Resolved
IN COMPARTMENT IN WAY OF SECOND ACCESS COVER, PORT HULL, RENEW MIDDLE INBOARD STRINGER INTO COMPARTMENTS FORE AND AFT(TO GOOD WOOD), WITH PROPER SCARFS
Condition: Unknown
Due 25 August 1993
Resolved 26 August 1993
Construction/Loadline
Issued 24 July 1992 Resolved
AT NEXT DRYDOCK INSPECTION, MAKE THE STARBOARD AFT COMPARTMENT ACCESSIBLE FOR ENTRY.
Condition: Unknown
Due 24 July 1992
Resolved 24 July 1992
Electrical
Issued 24 July 1992 Resolved
REPLACE COVER ON WIRE OUTLET LOCATED ON AIR COMPRESSOR.
Condition: Unknown
Due 24 July 1992
Resolved 24 July 1992
Construction/Loadline
Issued 17 May 1991 Resolved
PROVIDE OIL POLLUTION PLACARD. THIS OUTSTANDING REQUIREMENT IS TO BE MADE INTO A SPECIAL NOTE TO EXPIRE 26 JUL 92.
Condition: Unknown
Due 12 August 1991
Resolved 12 August 1991

Casualty record · 3

11 March 2011Routine · role: Involved in a Marine Casualty · activity 3962507
18 March 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4819084
14 March 2015Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 5095486
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.