NEW DEL MAR is a passenger vessel (inspected). The Coast Guard has recorded 51 inspections since 2002, most recently in September 2025, along with 67 deficiencies, 2 operational controls and 2 casualty investigations between 2014 and 2019.

Records from 2002 to 2025. Most recent: inspection, 12 September 2025.

Built
Not recorded
Last inspected
12 September 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDN5497
Flag
UNITED STATES
366855060
Maury page id
psix-33721

Inspections, by type

…with no type recorded4
Years with a record 22 calendar years (2002–2025)
The 51 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)74.8 ft × 24.5 ft × 6.4 ft
Registered tonnagegross 78 / net 62
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNORTHWIND MARINE INC · SEATTLE, WA, UNITED STATES
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portLOS ANGELES, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 10 February 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it78 - Simplified, Gross Ton
55 - Displacement, Ton
62 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDN5497MMSI 366855060 · active · compulsorily equipped · granted 29 December 2022, expires 29 December 2032
WDA8503MMSI 366855060 · expired · compulsorily equipped · granted 3 April 2012, cancelled 30 July 2022
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 51

12 September 2025 Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8086150
4 September 2025 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8086154
2 December 2024 Appeal · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8017366
16 October 2024 Examination of Repairs · Deficiency Check · Plan Review "T" Boat
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8020062
17 October 2023 Annual Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7788038
7 September 2023 Hull Examination · Examination of Repairs · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7762669
17 October 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7553770
25 October 2021 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7339443
12 October 2021 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7329280
14 September 2021 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7311700
22 March 2021 Damage Survey · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7161091
10 September 2020 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7047093
11 September 2019 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6809366
5 September 2019 Examination of Repairs · Administrative Inspection · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6805040
21 July 2019 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6763115
20 September 2018 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6539094
29 November 2017 Administrative Inspection
Administrative · Navigation Center · Activity 6314651
5 October 2017 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6274781
26 September 2017 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6175700
27 October 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6026342
6 October 2015 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5742035
9 September 2015 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5721405
1 September 2015 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5232657
5 August 2014 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4947078
5 May 2014 Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4851390
4 May 2014 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4851130
29 September 2011 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4157528
13 September 2011 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4143477
24 January 2011 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3931920
13 October 2010 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3869398
1 October 2010 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3861293
9 September 2010 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3845518
22 December 2009 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3655967
11 February 2009 DAPI Audit
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3416358
18 September 2008 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3322839
9 September 2008 Drydock Exam · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3320949
15 January 2008 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3141575
8 January 2008 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3127021
11 December 2007 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3111792
11 September 2007 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3022633
16 October 2006 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2786629
22 September 2005 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2493174
13 September 2005 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2487596
17 September 2004 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2198906
14 September 2004 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2181574
14 September 2004 Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2195778
23 December 2003 Type not recorded
No type recorded · USCGC STEADFAST (WMEC 623) · Activity 1990761
7 October 2003 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1897073
30 April 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1783844
3 May 2002 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1612373
27 April 2002 Construction Oversight
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1602997

Deficiency record · 67

07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 2 December 2024 Resolved
A device must be provided to automatically shut down power ventilation serving the protected space and engines that draw intake air from the protected space prior to release of the extinguishing agent into the space. Power ventilation, generator, and engine did not shutdown. Vessel must submit a letter indicating how they will mitigate a fire in the engine room until fixed. 46 CFR 181.410 (b) (10)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2024
Resolved 31 January 2025
Resolution: Witnessed the proper shutdown of the engine, generator, and ventilation via installed fire fighiting system.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 2 December 2024 Resolved
System design and installation must be in accordance with the Marine Design, Installation, Operation, and Maintenance Manual approved for the system by the Commandant. CO2 cylinder was found to be missing a cap at the discharge head. 46 CFR 181.410 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2024
Resolved 19 December 2024
Resolution: CO2 cylinder's cap has been replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 December 2024 Resolved
Machinery space boundaries. Boundaries that separate machinery spaces from accommodation spaces, service spaces, and control spaces must be lined with noncombustible panels or insulation approved in accordance with § 164.009 in subchapter Q of this chapter, or other standard specified by the Commandant. Port side engine room fwd bulkhead wire run is missing noncombustible insulation. 46 CFR 177.410 (c) (4)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2024
Resolved 19 December 2024
Resolution: Missing noncombustible insulation has been replaced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 December 2024 Resolved
On a vessel of not more than 19.8 meters (65 feet) in length carrying more than 49 passengers, and on a vessel of more than 19.8 meters (65 feet) in length, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. The pump outlet must be fitted with a working pressure gauge. 46 CFR 181.300 (b)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2024
Resolved 19 December 2024
Resolution: Pressure gauge has been replaced and pressure is above 60 psi.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 December 2024 Resolved
A bilge pipe piercing the collision bulkhead must be fitted with a screw-down valve located on the forward side of the collision bulkhead and operable from the weather deck, or, if it is readily accessible under service conditions, a screw-down valve without a reach rod may be fitted to the bilge line on the after side of the collision bulkhead. Vessel does not have a screw down valve and is not operable from the weather deck. 46 CFR 182.510 (d)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2025
Resolved 12 September 2025
Resolution: MI verified screw-down value located on the forward side of the collision bulkhead was installed and is operational.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 2 December 2024 Resolved
Cooking and heating equipment must be suitable for marine use. Equipment designed and installed in accordance with American Boat and Yacht Council (ABYC) A-3, “Galley Stoves,” and A-7, “Boat Heating Systems,” or with National Fire Protection Association (NFPA) 302, “Pleasure and Commercial Motor Craft,” complies with this requirement, except as restricted by § 184.202 of this part. Starboard side light bulb is missing the glass cover. 46 CFR 184.200
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2024
Resolved 19 December 2024
Resolution: Galley hood's starboard side light bulb glass cover has been replaced.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 2 December 2024 Resolved
(a) As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (2) U.S. Coast Pilot or similar publication; (3) Coast Guard Light List. U.S. Coast Pilot and Coast Guard Light List were out of date. 46 CFR 184.420 (a)(2&3)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2024
Resolved 19 December 2024
Resolution: Vessel procured 2024 U.S. Coast Pilot and Coast Guard Light List.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 2 December 2024 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. Maximum passengers allowed was not clearly marked. 46 CFR 185.602 (g)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2024
Resolved 19 December 2024
Resolution: Maximum passengers allowed at the upper deck is now clearly marked.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 17 October 2022 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. Max Persons allowed on upper deck not marked. 46CFR185.602(g)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2022
Resolved 13 November 2022
Resolution: Max Persons allowed on upper deck has been marked.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Equipment (including exemption)
Issued 17 October 2022 Resolved
Except as noted in paragraph (c) of this section, stations in the maritime service must be licensed by the FCC either individually or by fleet. Vessel station license is expired. 47 CFR 80.13
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2022
Resolved 29 December 2022
Resolution: FCC station license has been re-issued.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 17 October 2022 Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. Certificate of documentation not on board vessel.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 November 2022
Resolved 13 November 2022
Resolution: Certificate of documentation is now onboard vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 12 October 2021 Resolved
Vessel had (03) floating water light that were inoperable for life floats. Vessel reduce to 75 max persons allowed onboard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 November 2021
Resolved 25 October 2021
Resolution: Vessel renewed (03) floating water light for life floats; all satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 March 2021 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel suffered loss of propulsion. Vessel must prove proper operation of propulsion machinery prior to departure or carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 March 2021
Resolved 23 March 2021
Resolution: Vessel proved proper operation of propulsion machinery to the satisfaction of the attending marine inspector.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 16 September 2019 Resolved
EPIRB Battery found to be expired.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 16 September 2019
Resolution: Vessel rep renewed battery.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 16 September 2019 Resolved
Vessel 6 orange smoke flares were found to be expired.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 16 September 2019
Resolution: Vessel procured new flares.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 20 September 2018 Resolved
AIS on vessel is displaying incorrect length and beam. Correct AIS vessel dimensions to properly reflect actual vessel characteristics.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 October 2018
Resolution: AIS system accurately displays vessel's ship characteristics.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 20 September 2018 Resolved
Forward most lifefloat is missing waterlight. Attach floating waterlight to lifefloat as indicated by the marine inspector. Passenger count reduced to 125 until rectified.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 October 2018
Resolution: Vessel installed waterlight to forward most lifefloat; all sat.
Engineering › Bilge Water Management System › Pump
Issued 27 October 2016 Resolved
Remove wire nuts and make proper electrical connections to the forepeak bilge pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2016
Resolved 27 October 2016
Resolution: Vessel removed wire nuts and made proper connections.
Engineering › Fuel Oil Service System › Valve, Control
Issued 6 October 2015 Resolved
Relocate fuel isolation valve outside engine compartment or shield valve within 12" with material
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 October 2015
Resolved 6 October 2015
Resolution: MI received satisfactory evidence of proper installation of fire shield protecting fuel isolation valve within the engine room.
Engineering › Fuel Oil Service System › Valve, Control
Issued 17 September 2015 Resolved
Relocate fuel isolation valve outside the engine compartment or shielded within 12" of the door opening.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 October 2015
Resolved 6 October 2015
Resolution: MI received satisfactory evidence of proper instillation of flame shield.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 17 September 2015 Resolved
Provide service report showing evidence of CO2 bottles being weighed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 October 2015
Resolved 18 September 2015
Resolution: Vessel rep provided fire servicing report shich captured the weights of the fixed CO2 system. The report stated that there was no loss of agent, and found to be 100% full.
Construction/Loadline › Structures › Manhole
Issued 17 September 2015 Resolved
Submit repair proposal for pitts identified along the lazerette hatch combing. Pitts penetrated through the entire thickness of alumininum plating.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 October 2015
Resolved 17 September 2015
Resolution: Vessel rep submitted repair proposal and stated that temp repairs to the pitting were made.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 October 2010 Resolved
Vessel is restricted from carrying passengers until completion of COI 5-year renewal inspection.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 1 October 2010
Resolution: Inspected vessel for 5 year COI, removed op control for same.
Communications › Radio Communications › EPIRB
Issued 1 October 2010 Resolved
Replace as new, hydrostatic release in way of EPIRB, vessel prohibited from operating beyond 3 miles from the coastline. IAW 46 CFR 180.64
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 October 2010
Resolved 6 October 2010
Resolution: Received invoice for new hydrostatic release.
Navigation › Piloting/Steering › Marine Charts
Issued 1 October 2010 Resolved
Provide updated navigational charts and publications, IAW 46 CFR 184.420.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 October 2010
Resolved 13 October 2010
Resolution: Charts and pubs updated.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 1 October 2010 Resolved
Stow fire extinguisher in way of the pilot house in the correct bracket IAW manufactures instructions.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2010
Resolved 13 October 2010
Resolution: New approved fire extinguisher installed in proper bracket was located in pilot house.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 1 October 2010 Resolved
Renew as original, both hydraulic winch lines in way of forepeak and add chafing gear as needed. IAW 46 CFR 182.720 (e)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2010
Resolved 13 October 2010
Resolution: Hydraulic lines replaced with RYCO DIEHARD T212D "3/4 max.
Engineering › Bilge Water Management System › Piping
Issued 1 October 2010 Resolved
Replace pedro connections with hard pipe, in way of bilge and fire pump discharge located in the engine room. IAW 46 CFR 182.720 (e) (3) (v)
Action required: 705 - Other - as specified
Due 1 January 2011
Resolved 24 January 2011
Resolution: Pedro connections have been replace with metal couplers.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 1 October 2010 Resolved
Located fire axe in or adjacent to the pilot house. IAW 46 CFR 181.600
Action required: 705 - Other - as specified
Due 31 October 2010
Resolved 13 October 2010
Resolution: Fire axe refurbished and placed in pilot house.
Electrical › Electric Supply System (service) › Cable
Issued 1 October 2010 Resolved
Remove wing nuts and refasten DC electrical connections in way of batteries located in the engine room with hexagonal nuts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2010
Resolved 13 October 2010
Resolution: Hex nuts installed on battery connections.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 October 2010 Resolved
Install machinery guards over exposed rotating machinery on the main engine and generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2010
Resolved 13 October 2010
Resolution: Witnessed guards intalled.
Operations/Management › Drills/Instruction › Not Conducted
Issued 1 October 2010 Resolved
Conduct man overboard and fire drills with crew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 October 2010
Resolved 13 October 2010
Resolution: Witnessed drills, crew trained well.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 11 February 2009 Resolved
Require copy of contract or proof of enrollment in consortium.
Due 13 March 2009
Resolved 13 February 2009
Resolution: Copy of contract/proof of enrollment received.
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 11 February 2009 Resolved
Require proof of random testing spread equally throughout the year based on statistical methodology.
Due 13 March 2009
Resolved 13 February 2009
Resolution: Proof of compliance received by way of consortium documentation.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 11 February 2009 Resolved
Require proper EAP display on vessel, specifically hotline number and substance abuse professional (SAP) contact information.
Due 13 March 2009
Resolved 13 February 2009
Resolution: Received photograph of subject vsl demonstrating compliance.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 18 September 2008 Resolved
Replace/renew exhaust heat shielding on main engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 November 2008
Resolved 28 October 2008
Resolution: New lagging confirmed installed on engine exhaust.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 18 September 2008 Resolved
Provide guards for exposed rotating machinery on main engine and generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 November 2008
Resolved 28 October 2008
Resolution: Machinery guards re-installed on main engine & generator.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 18 September 2008 Resolved
Replace/renew 50 amp shore breaker cover.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 November 2008
Resolved 22 December 2009
Fire Fighting › Grease Extraction Hood › General
Issued 18 September 2008 Resolved
Clean galley exhaust duct of all grease.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 November 2008
Resolved 22 December 2009
Fire Fighting › Fire Hoses › Condition
Issued 18 September 2008 Resolved
Replace worn fire hose.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 September 2008
Resolution: Purchased new fire hose.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 18 September 2008 Resolved
Repair leak in main fire pump.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 November 2008
Resolved 22 December 2009
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 18 September 2008 Resolved
Move fixed firefighting system manual control to location outside space being protected.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 November 2008
Resolved 28 October 2008
Resolution: Fixed system manual control moved cabin entrance (outside space protected--engine space).
Lifesaving › Lifebuoys › Serviceable
Issued 18 September 2008 Resolved
Replace 02 ring buoys.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 September 2008
Resolved 18 September 2008
Resolution: Purchased 02 new ring buoys
Fire Fighting › Fire Hydrants › Condition
Issued 18 September 2008 Resolved
Provide means to remove fire hose at fire station.
Due 18 October 2008
Resolved 28 October 2008
Resolution: New wrench installed at fire station.
Documentation › Logs/Records › MIS Form
Issued 18 September 2008 Resolved
Provide evidence of 2007 MIS report.
Action required: 705 - Other - as specified
Due 1 November 2008
Resolved 28 October 2008
Resolution: Copy of MIS report provided.
Personnel › Training › First Aid/CPR
Issued 11 December 2007 Resolved
Provide proof of first aid/CPR certification for at least 50% of crew members.
Action required: 705 - Other - as specified
Due 11 February 2008
Resolved 17 January 2008
Resolution: Vessel rep faxed a roster of the crew members who attended and got their CPR cards.
Accommodation/Occupational Safety › Cooking Systems › CNG System Requirements
Issued 11 December 2007 Resolved
Clean excess grease from galley vent fans and vent ducting and trap.
Action required: 705 - Other - as specified
Due 11 January 2008
Resolved 8 January 2008
Resolution: Cleaned satisfactorily.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 11 December 2007 Resolved
Update crew list for Drug and Alcohol Program to include all crew members.
Action required: 705 - Other - as specified
Due 11 January 2008
Resolved 8 January 2008
Resolution: Provided up to date list accounting for all employees.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 11 December 2007 Resolved
Provide proof of pre-employment and random drug testing.
Action required: 705 - Other - as specified
Due 11 January 2008
Resolved 11 December 2007
Resolution: Consortium faxed Sector LA-LB copies of pre-employment and random test results.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 11 December 2007 Resolved
Provide proof of one hour EAP training for supervisor.
Action required: 705 - Other - as specified
Due 11 April 2008
Resolved 20 March 2008
Resolution: Received from vessel owner/operator that 5 members of the crew had attended a formal EAP training course sponsored by the Sportfishing Association of California.
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 11 December 2007 Resolved
It has been determined that your vessel arrangement is such that an unconscious person cannot be recovered from the water without additional equipment. Provide rescue boat or platform or other suitable arrangement IAW 46CFR 180.210 to the satisfaction of the attending CG Marine Inspector.
Action required: 705 - Other - as specified
Due 11 January 2008
Resolved 8 January 2008
Resolution: Vessel purchased a life sling and will utilize a jacobs ladder with the crew member on the ladder tethered and tended to assist the person in the water. Vessel has adequate crew to assist.
Communications › Radio Communications › EPIRB
Issued 16 October 2006 Resolved
Renew EPIRB battery prior to carrying passengers beyond three miles from shore IAW 46CFR 180.64.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 October 2006
Resolution: EPIRB renewed.
Electrical › Electric Supply System (service) › Cable
Issued 22 September 2005 Resolved
Replace plastic wire ties with metal supports.
Action required: 705 - Other - as specified
Due 22 September 2005
Resolved 22 September 2005
Resolution: Vessel replaced wire ties with metal supports.
Engineering › Sea-water System (primary cooling) › Piping
Issued 22 September 2005 Resolved
Provide supports for piping in pump room.
Action required: 705 - Other - as specified
Due 22 September 2005
Resolved 22 September 2005
Resolution: Vessel installed supports for piping.
Documentation › Logs/Records › Drug Test Records
Issued 22 September 2005 Resolved
Provide drug testing program documentation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2005
Resolved 22 September 2005
Resolution: Vessel provided drug testing paperwork.
Documentation › Certificates/Documents › Stability Letter
Issued 22 September 2005 Resolved
Provide and post stability letter.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2005
Resolved 22 September 2005
Resolution: Vessel provided stability letter.
Accommodation/Occupational Safety › Ventilation › General
Issued 22 September 2005 Resolved
Repair/replace broken window on starboard side galley window.
Action required: 705 - Other - as specified
Due 13 October 2005
Resolved 11 November 2005
Documentation › Certificates/Documents › Certificate of Inspection
Issued 13 September 2005 Resolved
Vessel must under go annual exam prior to taking passengers. COI annual expires 18 SEP 05. Scheduled COI annual exam is 22 SEP 05. Vessel may not take passengers from 13 SEP 05 until successful annual exam is complete.
Action required: 705 - Other - as specified
Due 13 October 2005
Resolved 22 September 2005
Resolution: Conducted Sat COI exam.
Construction/Loadline › Penetrations › Gasket
Issued 13 September 2005 Resolved
Service hatch gaskets (all hatch gaskets)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 October 2005
Resolved 22 September 2005
Resolution: Vessel serviced hatch gaskets.
Construction/Loadline › Penetrations › Valve Flange
Issued 13 September 2005 Resolved
Thoroughly clean all thru hull's and valves.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 October 2005
Resolved 22 September 2005
Construction/Loadline › Structures › Machinery Space Opening
Issued 13 September 2005 Resolved
Emergency tiller access hatch needs a securing cable.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 October 2005
Resolved 22 September 2005
Resolution: Vessel installed securing cable.
Accommodation/Occupational Safety › Ventilation › General
Issued 13 September 2005 Resolved
Repair/replace broken window on starboard side galley window.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 October 2005
Resolved 11 November 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 13 September 2005 Resolved
Provide fixed fire fighting system report.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 October 2005
Resolved 22 September 2005
Resolution: Vessel provide fixed fire fighting report.
Operations/Management › Vessel Safety Management › External Certification/Verification/Control
Issued 14 September 2004 Resolved
Schedule and complete annual exam.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 September 2004
Resolution: Annual exam conducted.
Construction/Loadline › Hull › Weld
Issued 7 October 2003 Resolved
Required vessel to install grid coolers on hull constructed from material of the same strength as the hull. The guards are to be chain welded onto the hull. LEGACY COMPONENT DESC: Bottom Plating
Action required: 705 - Other - as specified
Due 31 October 2004
Resolved 14 September 2004
Resolution: Aluminum guards installed for grid coolers. Allowed O/O to install guards with stainless steel bolt as opposed to chain welding to allow for easier main.
Deck/Cargo › Mooring/Anchoring
Issued 9 April 2003 Resolved
Make repairs to anchor windlass. Maintain anchor, line, chain, and tackle onboard at all times while carrying passengers. LEGACY COMPONENT DESC: Capstan
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 23 May 2003
Resolved 10 April 2003
Resolution: Anchor windlass repaired to the satisfaction of the attending marine inspector.
Engineering › Sea-water System (primary cooling)
Issued 3 May 2002 Resolved
Install shut off valves where the keel cooler penetrates hull. 46 CFR 182.422(b). LEGACY COMPONENT DESC: Valve
Action required: 705 - Other - as specified
Due 29 April 2004
Resolved 7 October 2003
Resolution: Determined that shut off valves were not required. Vessel has grid coolers.

Casualty record · 2

4 May 2014Routine · role: Involved in a Marine Casualty · activity 4851130
21 July 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6763115
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.